{"title":"K-LOK 400A Double Set Screw Panel Receptacles","description":"\u003c!-- KUPO Power - K-LOK 400A Double Set Screw Panel Receptacles (TIER 2 - Mid-Tier Slice, Panel Termination Subtype)\n     Shopify Collection Body HTML\n     Handle: k-lok-400a-double-set-screw-panel-receptacles\n     URL: https:\/\/kupopower.com\/collections\/k-lok-400a-double-set-screw-panel-receptacles --\u003e\n\n\u003cp\u003eK-LOK 400A panel receptacles with double set-screw termination use a clamp-style mechanism with two opposing set screws to secure stripped cable directly inside the connector body. No crimp lug required: strip the cable, insert it into the termination chamber, torque both set screws to specification. The double-set-screw method is the preferred choice for portable distribution, touring road cases, mobile generator panels, and any environment where cables may need to be reconfigured between gigs or between installations.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDouble Set Screw vs Threaded Stud\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"border-collapse:collapse !important; width:100%; max-width:600px; border:1px solid #999 !important;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background:#0072B8 !important; color:#fff !important;\"\u003e\n\u003cth style=\"padding:8px !important; border:1px solid #c0d8ee !important; color:#fff !important; background:#0072B8 !important; text-align:left;\"\u003e\u003c\/th\u003e\n\u003cth style=\"padding:8px !important; border:1px solid #c0d8ee !important; color:#fff !important; background:#0072B8 !important; text-align:left;\"\u003eThreaded Stud\u003c\/th\u003e\n\u003cth style=\"padding:8px !important; border:1px solid #c0d8ee !important; color:#fff !important; background:#0072B8 !important; text-align:left;\"\u003eDouble Set Screw\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important; font-weight:bold;\"\u003eTermination method\u003c\/td\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important;\"\u003eBolt-on crimp lug, torqued to spec\u003c\/td\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important;\"\u003eClamp-style with two opposing set screws\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important; font-weight:bold;\"\u003eCable preparation\u003c\/td\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important;\"\u003eCrimp lug onto stripped cable\u003c\/td\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important;\"\u003eStrip cable, insert, torque set screws\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important; font-weight:bold;\"\u003eBest for\u003c\/td\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important;\"\u003ePermanent and semi-permanent installations\u003c\/td\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important;\"\u003ePortable distribution and frequent reconfiguration\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important; font-weight:bold;\"\u003eField changes\u003c\/td\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important;\"\u003eSlower (requires re-crimping)\u003c\/td\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important;\"\u003eFaster (loosen, re-strip, re-clamp)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"margin-top:1.25rem;\"\u003eNeed bolt-on lug termination instead? \u003ca href=\"https:\/\/kupopower.com\/collections\/k-lok-400a-threaded-stud-panel-receptacles\"\u003e\u003cstrong\u003eBrowse K-LOK 400A Threaded Stud Panel Receptacles →\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","products":[{"product_id":"kl-400lfb","title":"KL-400LFB - K-LOK 400A Female CAM-Type Line Connector, Blue","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400LFB --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400LFB\" data-color=\"Blue\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Female Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eNon-conductive POM (Polyoxymethylene) retaining screw locks the brass contact firmly in position, eliminating accidental current paths for safer operation\u003c\/li\u003e\n      \u003cli\u003ePOM insulation sleeve adds heat resistance and structural strength to the contact assembly\u003c\/li\u003e\n      \u003cli\u003eRibbed Santoprene TPV housing provides a secure, slip-free grip even when wearing work gloves\u003c\/li\u003e\n      \u003cli\u003eAlignment arrow ensures correct orientation for fast, error-free mating every time\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding site conditions and extreme temperatures\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors with redundant cable retention\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing power infrastructure from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Female In-Line Connector intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400LFB | K-LOK 400A Single-Pole Line Connector, Female, Blue, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Female Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400LFB\",\n  \"mpn\": \"KL-400LFB\",\n  \"color\": \"Blue\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Female\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Blue\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Phase C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Retaining Screw Material\",\n      \"value\": \"POM (Polyoxymethylene), Non-conductive\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screws\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400LFB\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWho should use KL-400LFB and why?\u003c\/h3\u003e\n    \u003cp\u003eLighting technicians, electricians, and power distribution professionals working with 400A temporary power systems will benefit from KL-400LFB. Its blue housing provides instant visual phase identification, while the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius ensures durability in demanding field conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat voltage and amperage is KL-400LFB rated for?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFB carries a maximum rating of 400A and 600V AC\/DC. It accepts wire gauges from #6 to 4\/0 AWG, making it suitable for the conductor sizes typically used in 400-amp power distribution circuits.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhy choose the blue version of the K-LOK 400A female line connector?\u003c\/h3\u003e\n    \u003cp\u003eIn North America, blue designates Phase C (L3), completing the three-phase color set. Under IEC 60446, blue is reserved for the Neutral conductor - making this color essential for international projects and cross-border equipment pools. Choosing KL-400LFB in blue ensures your power distribution system follows established color conventions, speeding up setup and reducing wiring errors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs KL-400LFB UL listed and what does that mean?\u003c\/h3\u003e\n    \u003cp\u003eYes. KL-400LFB is cUL Listed under File Number E332947, meaning it has been independently tested and certified to UL 1691 safety standards by a Nationally Recognized Testing Laboratory. This certification is required for professional power distribution in most North American jurisdictions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat industries commonly use KL-400LFB?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFB is widely used in industrial temporary power connections for manufacturing and processing facilities. Its 400A \/ 600V AC\/DC rating, combined with CAM-type universal compatibility and blue phase coding, makes it a versatile choice across the entertainment, construction, and industrial sectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Who should use KL-400LFB and why?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Lighting technicians, electricians, and power distribution professionals working with 400A temporary power systems will benefit from KL-400LFB. Its blue housing provides instant visual phase identification, while the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius ensures durability in demanding field conditions.\"}}, {\"@type\": \"Question\", \"name\": \"What voltage and amperage is KL-400LFB rated for?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFB carries a maximum rating of 400A and 600V AC\/DC. It accepts wire gauges from #6 to 4\/0 AWG, making it suitable for the conductor sizes typically used in 400-amp power distribution circuits.\"}}, {\"@type\": \"Question\", \"name\": \"Why choose the blue version of the K-LOK 400A female line connector?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"In North America, blue designates Phase C (L3), completing the three-phase color set. Under IEC 60446, blue is reserved for the Neutral conductor - making this color essential for international projects and cross-border equipment pools. Choosing KL-400LFB in blue ensures your power distribution system follows established color conventions, speeding up setup and reducing wiring errors.\"}}, {\"@type\": \"Question\", \"name\": \"Is KL-400LFB UL listed and what does that mean?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. KL-400LFB is cUL Listed under File Number E332947, meaning it has been independently tested and certified to UL 1691 safety standards by a Nationally Recognized Testing Laboratory. This certification is required for professional power distribution in most North American jurisdictions.\"}}, {\"@type\": \"Question\", \"name\": \"What industries commonly use KL-400LFB?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFB is widely used in industrial temporary power connections for manufacturing and processing facilities. Its 400A \/ 600V AC\/DC rating, combined with CAM-type universal compatibility and blue phase coding, makes it a versatile choice across the entertainment, construction, and industrial sectors.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400LFB\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/KL-400LFB%20Data%20Sheet.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download KL-400LFB Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Inline Connector","offer_id":50208818659548,"sku":"KL-400LFB","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400LFB.jpg?v=1777362803"},{"product_id":"kl-400lfbk","title":"KL-400LFBK - K-LOK 400A Female CAM-Type Line Connector, Black","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400LFBK --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400LFBK\" data-color=\"Black\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Female Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eNon-conductive POM (Polyoxymethylene) retaining screw locks the brass contact firmly in position, eliminating accidental current paths for safer operation\u003c\/li\u003e\n      \u003cli\u003ePOM insulation sleeve adds heat resistance and structural strength to the contact assembly\u003c\/li\u003e\n      \u003cli\u003eRibbed Santoprene TPV housing provides a secure, slip-free grip even when wearing work gloves\u003c\/li\u003e\n      \u003cli\u003eAlignment arrow ensures correct orientation for fast, error-free mating every time\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding site conditions and extreme temperatures\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors with redundant cable retention\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing power infrastructure from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Female In-Line Connector intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400LFBK | K-LOK 400A Single-Pole Line Connector, Female, Black, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Female Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400LFBK\",\n  \"mpn\": \"KL-400LFBK\",\n  \"color\": \"Black\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Female\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Black\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Phase A \/ General\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Retaining Screw Material\",\n      \"value\": \"POM (Polyoxymethylene), Non-conductive\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screws\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400LFBK\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is KL-400LFBK and what is it designed for?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFBK is a KUPO K-LOK 400A single-pole female inline cable connector with a black housing, rated for 600V AC\/DC maximum. It is engineered for heavy-duty temporary power distribution in entertainment, industrial, and event production settings. The black color coding aids rapid phase identification on the job site.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat wire sizes does KL-400LFBK accept?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFBK accommodates conductors ranging from #6 to 4\/0 AWG. The brass contact assembly ensures reliable electrical performance across this full conductor range, supporting up to 400A at 600V AC\/DC.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhich electrical phase does the black color represent on KL-400LFBK?\u003c\/h3\u003e\n    \u003cp\u003eUnder North American NEMA\/NEC conventions, black identifies Phase A (L1), making it the go-to choice for single-phase circuits and the default lead in three-phase systems. In IEC regions, black denotes Phase B (L2). Having a dedicated black connector in your inventory means phase assignments are physically enforced, minimizing the chance of cross-phase connection errors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does KL-400LFBK protect against electrical hazards?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFBK incorporates multiple safety features: the non-conductive POM retaining screw prevents accidental current paths through the housing, the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius resists heat and impact, brass contacts minimize resistive heating, and the design meets UL 1691 safety requirements under cUL Listed E332947. The UL Enclosure Types 3R rating also provides protection in wet or outdoor conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs KL-400LFBK compatible with other CAM-type connectors?\u003c\/h3\u003e\n    \u003cp\u003eYes. KL-400LFBK follows the universal CAM-type single-pole connector standard and intermates with CAM-type connectors from all major manufacturers. This cross-brand compatibility means you can integrate K-LOK connectors into existing power distribution systems without replacing your entire inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat makes KL-400LFBK easy to use during fast-paced setups?\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK tool-free design means KL-400LFBK can be assembled and disassembled without specialized equipment. The ribbed Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius provides a secure grip even with work gloves, and the alignment arrow guides correct mating orientation - cutting connection time on busy sets and stages.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is KL-400LFBK and what is it designed for?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFBK is a KUPO K-LOK 400A single-pole female inline cable connector with a black housing, rated for 600V AC\/DC maximum. It is engineered for heavy-duty temporary power distribution in entertainment, industrial, and event production settings. The black color coding aids rapid phase identification on the job site.\"}}, {\"@type\": \"Question\", \"name\": \"What wire sizes does KL-400LFBK accept?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFBK accommodates conductors ranging from #6 to 4\/0 AWG. The brass contact assembly ensures reliable electrical performance across this full conductor range, supporting up to 400A at 600V AC\/DC.\"}}, {\"@type\": \"Question\", \"name\": \"Which electrical phase does the black color represent on KL-400LFBK?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Under North American NEMA\/NEC conventions, black identifies Phase A (L1), making it the go-to choice for single-phase circuits and the default lead in three-phase systems. In IEC regions, black denotes Phase B (L2). Having a dedicated black connector in your inventory means phase assignments are physically enforced, minimizing the chance of cross-phase connection errors.\"}}, {\"@type\": \"Question\", \"name\": \"How does KL-400LFBK protect against electrical hazards?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFBK incorporates multiple safety features: the non-conductive POM retaining screw prevents accidental current paths through the housing, the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius resists heat and impact, brass contacts minimize resistive heating, and the design meets UL 1691 safety requirements under cUL Listed E332947. The UL Enclosure Types 3R rating also provides protection in wet or outdoor conditions.\"}}, {\"@type\": \"Question\", \"name\": \"Is KL-400LFBK compatible with other CAM-type connectors?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. KL-400LFBK follows the universal CAM-type single-pole connector standard and intermates with CAM-type connectors from all major manufacturers. This cross-brand compatibility means you can integrate K-LOK connectors into existing power distribution systems without replacing your entire inventory.\"}}, {\"@type\": \"Question\", \"name\": \"What makes KL-400LFBK easy to use during fast-paced setups?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The K-LOK tool-free design means KL-400LFBK can be assembled and disassembled without specialized equipment. The ribbed Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius provides a secure grip even with work gloves, and the alignment arrow guides correct mating orientation - cutting connection time on busy sets and stages.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400LFBK\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/KL-400LFBK%20Data%20Sheet.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download KL-400LFBK Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Inline Connector","offer_id":50208818692316,"sku":"KL-400LFBK","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400LFBK.jpg?v=1777362804"},{"product_id":"kl-400lfbn","title":"KL-400LFBN - K-LOK 400A Female CAM-Type Line Connector, Brown","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400LFBN --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400LFBN\" data-color=\"Brown\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Female Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eNon-conductive POM (Polyoxymethylene) retaining screw locks the brass contact firmly in position, eliminating accidental current paths for safer operation\u003c\/li\u003e\n      \u003cli\u003ePOM insulation sleeve adds heat resistance and structural strength to the contact assembly\u003c\/li\u003e\n      \u003cli\u003eRibbed Santoprene TPV housing provides a secure, slip-free grip even when wearing work gloves\u003c\/li\u003e\n      \u003cli\u003eAlignment arrow ensures correct orientation for fast, error-free mating every time\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding site conditions and extreme temperatures\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors with redundant cable retention\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing power infrastructure from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Female In-Line Connector intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400LFBN | K-LOK 400A Single-Pole Line Connector, Female, Brown, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Female Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400LFBN\",\n  \"mpn\": \"KL-400LFBN\",\n  \"color\": \"Brown\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Female\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Brown\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Phase A (IEC)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Retaining Screw Material\",\n      \"value\": \"POM (Polyoxymethylene), Non-conductive\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screws\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400LFBN\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat kind of connector is KL-400LFBN?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFBN is a 400-ampere, 600V AC\/DC single-pole female inline cable connector from the KUPO K-LOK series. Finished in brown, it belongs to the CAM-type connector family widely used across live events, film production, and temporary industrial power systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current can KL-400LFBN safely carry?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFBN is designed for a maximum continuous load of 400 amperes at up to 600V AC\/DC. The brass contacts and Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius work together to maintain safe operating temperatures even under sustained full-load conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does the brown color coding on KL-400LFBN help on a busy job site?\u003c\/h3\u003e\n    \u003cp\u003eOn a crowded set or event site, identifying conductors quickly is a safety essential. Brown designates Phase A (L1) under IEC 60446 conventions used across Europe, the UK, Asia, and Australia. For productions touring internationally or venues hosting global acts, brown connectors ensure IEC-standard phase identification is always available. The brown KL-400LFBN connector lets technicians trace circuits visually without needing to check labels or test equipment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety certifications does KL-400LFBN hold?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFBN is cUL Listed under File Number E332947, certified to UL 1691 - the Standard for Safety for Cam-Type, Locking-Type Separable Connectors. It carries a UL Enclosure Types 3R environment rating, HB \/ UL94 flame classification, and full RoHS (Restriction of Hazardous Substances) compliance.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eCan KL-400LFBN work with connectors from other brands?\u003c\/h3\u003e\n    \u003cp\u003eAbsolutely. The K-LOK 400A series uses the industry-standard CAM-type interface, so KL-400LFBN mates directly with compatible single-pole connectors regardless of manufacturer. This makes it easy to expand or upgrade your connector stock incrementally.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow do you assemble KL-400LFBN in the field?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFBN features a tool-free modular design that enables rapid assembly and disassembly on site. Strip the cable, insert it through the housing, secure it with the double set screw termination, and lock the brass contact in place with the non-conductive POM retaining screw. The alignment arrow ensures correct orientation every time.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What kind of connector is KL-400LFBN?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFBN is a 400-ampere, 600V AC\/DC single-pole female inline cable connector from the KUPO K-LOK series. Finished in brown, it belongs to the CAM-type connector family widely used across live events, film production, and temporary industrial power systems.\"}}, {\"@type\": \"Question\", \"name\": \"How much current can KL-400LFBN safely carry?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFBN is designed for a maximum continuous load of 400 amperes at up to 600V AC\/DC. The brass contacts and Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius work together to maintain safe operating temperatures even under sustained full-load conditions.\"}}, {\"@type\": \"Question\", \"name\": \"How does the brown color coding on KL-400LFBN help on a busy job site?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"On a crowded set or event site, identifying conductors quickly is a safety essential. Brown designates Phase A (L1) under IEC 60446 conventions used across Europe, the UK, Asia, and Australia. For productions touring internationally or venues hosting global acts, brown connectors ensure IEC-standard phase identification is always available. The brown KL-400LFBN connector lets technicians trace circuits visually without needing to check labels or test equipment.\"}}, {\"@type\": \"Question\", \"name\": \"What safety certifications does KL-400LFBN hold?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFBN is cUL Listed under File Number E332947, certified to UL 1691 - the Standard for Safety for Cam-Type, Locking-Type Separable Connectors. It carries a UL Enclosure Types 3R environment rating, HB \/ UL94 flame classification, and full RoHS (Restriction of Hazardous Substances) compliance.\"}}, {\"@type\": \"Question\", \"name\": \"Can KL-400LFBN work with connectors from other brands?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Absolutely. The K-LOK 400A series uses the industry-standard CAM-type interface, so KL-400LFBN mates directly with compatible single-pole connectors regardless of manufacturer. This makes it easy to expand or upgrade your connector stock incrementally.\"}}, {\"@type\": \"Question\", \"name\": \"How do you assemble KL-400LFBN in the field?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFBN features a tool-free modular design that enables rapid assembly and disassembly on site. Strip the cable, insert it through the housing, secure it with the double set screw termination, and lock the brass contact in place with the non-conductive POM retaining screw. The alignment arrow ensures correct orientation every time.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400LFBN\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/KL-400LFBN%20Data%20Sheet.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download KL-400LFBN Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Inline Connector","offer_id":50208818725084,"sku":"KL-400LFBN","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400LFBN.jpg?v=1777362805"},{"product_id":"kl-400lfg","title":"KL-400LFG - K-LOK 400A Female CAM-Type Line Connector, Green","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400LFG --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400LFG\" data-color=\"Green\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Female Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eNon-conductive POM (Polyoxymethylene) retaining screw locks the brass contact firmly in position, eliminating accidental current paths for safer operation\u003c\/li\u003e\n      \u003cli\u003ePOM insulation sleeve adds heat resistance and structural strength to the contact assembly\u003c\/li\u003e\n      \u003cli\u003eRibbed Santoprene TPV housing provides a secure, slip-free grip even when wearing work gloves\u003c\/li\u003e\n      \u003cli\u003eAlignment arrow ensures correct orientation for fast, error-free mating every time\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding site conditions and extreme temperatures\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors with redundant cable retention\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing power infrastructure from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Female In-Line Connector intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400LFG | K-LOK 400A Single-Pole Line Connector, Female, Green, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Female Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400LFG\",\n  \"mpn\": \"KL-400LFG\",\n  \"color\": \"Green\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Female\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Green\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Ground \/ Earth\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Retaining Screw Material\",\n      \"value\": \"POM (Polyoxymethylene), Non-conductive\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screws\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400LFG\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is KL-400LFG and what is it designed for?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFG is a KUPO K-LOK 400A single-pole female inline cable connector with a green housing, rated for 600V AC\/DC maximum. It is engineered for heavy-duty temporary power distribution in entertainment, industrial, and event production settings. The green color coding aids rapid phase identification on the job site.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat wire sizes does KL-400LFG accept?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFG accommodates conductors ranging from #6 to 4\/0 AWG. The brass contact assembly ensures reliable electrical performance across this full conductor range, supporting up to 400A at 600V AC\/DC.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhich electrical phase does the green color represent on KL-400LFG?\u003c\/h3\u003e\n    \u003cp\u003eGreen identifies the Ground (Earth \/ PE) conductor across North American and many international standards. Ground integrity is critical for personnel safety, and a distinct green connector ensures the safety earth is never confused with a current-carrying phase. Having a dedicated green connector in your inventory means phase assignments are physically enforced, minimizing the chance of cross-phase connection errors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does KL-400LFG protect against electrical hazards?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFG incorporates multiple safety features: the non-conductive POM retaining screw prevents accidental current paths through the housing, the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius resists heat and impact, brass contacts minimize resistive heating, and the design meets UL 1691 safety requirements under cUL Listed E332947. The UL Enclosure Types 3R rating also provides protection in wet or outdoor conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs KL-400LFG compatible with other CAM-type connectors?\u003c\/h3\u003e\n    \u003cp\u003eYes. KL-400LFG follows the universal CAM-type single-pole connector standard and intermates with CAM-type connectors from all major manufacturers. This cross-brand compatibility means you can integrate K-LOK connectors into existing power distribution systems without replacing your entire inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat housing material is used in KL-400LFG and why does it matter?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFG uses a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius. Santoprene TPV combines the flexibility of rubber with the processing advantages of thermoplastic, delivering excellent chemical resistance, UV stability, and durability under repeated mechanical stress - exactly what professional power connectors face on tour and on set.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is KL-400LFG and what is it designed for?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFG is a KUPO K-LOK 400A single-pole female inline cable connector with a green housing, rated for 600V AC\/DC maximum. It is engineered for heavy-duty temporary power distribution in entertainment, industrial, and event production settings. The green color coding aids rapid phase identification on the job site.\"}}, {\"@type\": \"Question\", \"name\": \"What wire sizes does KL-400LFG accept?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFG accommodates conductors ranging from #6 to 4\/0 AWG. The brass contact assembly ensures reliable electrical performance across this full conductor range, supporting up to 400A at 600V AC\/DC.\"}}, {\"@type\": \"Question\", \"name\": \"Which electrical phase does the green color represent on KL-400LFG?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Green identifies the Ground (Earth \/ PE) conductor across North American and many international standards. Ground integrity is critical for personnel safety, and a distinct green connector ensures the safety earth is never confused with a current-carrying phase. Having a dedicated green connector in your inventory means phase assignments are physically enforced, minimizing the chance of cross-phase connection errors.\"}}, {\"@type\": \"Question\", \"name\": \"How does KL-400LFG protect against electrical hazards?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFG incorporates multiple safety features: the non-conductive POM retaining screw prevents accidental current paths through the housing, the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius resists heat and impact, brass contacts minimize resistive heating, and the design meets UL 1691 safety requirements under cUL Listed E332947. The UL Enclosure Types 3R rating also provides protection in wet or outdoor conditions.\"}}, {\"@type\": \"Question\", \"name\": \"Is KL-400LFG compatible with other CAM-type connectors?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. KL-400LFG follows the universal CAM-type single-pole connector standard and intermates with CAM-type connectors from all major manufacturers. This cross-brand compatibility means you can integrate K-LOK connectors into existing power distribution systems without replacing your entire inventory.\"}}, {\"@type\": \"Question\", \"name\": \"What housing material is used in KL-400LFG and why does it matter?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFG uses a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius. Santoprene TPV combines the flexibility of rubber with the processing advantages of thermoplastic, delivering excellent chemical resistance, UV stability, and durability under repeated mechanical stress - exactly what professional power connectors face on tour and on set.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400LFG\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/KL-400LFG%20Data%20Sheet.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download KL-400LFG Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Inline Connector","offer_id":50208818757852,"sku":"KL-400LFG","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400LFG.jpg?v=1777362806"},{"product_id":"kl-400lfgy","title":"KL-400LFGY - K-LOK 400A Female CAM-Type Line Connector, Grey","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400LFGY --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400LFGY\" data-color=\"Grey\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Female Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eNon-conductive POM (Polyoxymethylene) retaining screw locks the brass contact firmly in position, eliminating accidental current paths for safer operation\u003c\/li\u003e\n      \u003cli\u003ePOM insulation sleeve adds heat resistance and structural strength to the contact assembly\u003c\/li\u003e\n      \u003cli\u003eRibbed Santoprene TPV housing provides a secure, slip-free grip even when wearing work gloves\u003c\/li\u003e\n      \u003cli\u003eAlignment arrow ensures correct orientation for fast, error-free mating every time\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding site conditions and extreme temperatures\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors with redundant cable retention\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing power infrastructure from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Female In-Line Connector intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400LFGY | K-LOK 400A Single-Pole Line Connector, Female, Grey, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Female Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400LFGY\",\n  \"mpn\": \"KL-400LFGY\",\n  \"color\": \"Grey\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Female\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Grey\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Neutral (IEC)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Retaining Screw Material\",\n      \"value\": \"POM (Polyoxymethylene), Non-conductive\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screws\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400LFGY\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWho should use KL-400LFGY and why?\u003c\/h3\u003e\n    \u003cp\u003eLighting technicians, electricians, and power distribution professionals working with 400A temporary power systems will benefit from KL-400LFGY. Its grey housing provides instant visual phase identification, while the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius ensures durability in demanding field conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat voltage and amperage is KL-400LFGY rated for?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFGY carries a maximum rating of 400A and 600V AC\/DC. It accepts wire gauges from #6 to 4\/0 AWG, making it suitable for the conductor sizes typically used in 400-amp power distribution circuits.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhy choose the grey version of the K-LOK 400A female line connector?\u003c\/h3\u003e\n    \u003cp\u003eGrey represents Phase C (L3) - and in some IEC applications, Neutral - under the international color code. Adding grey to the connector inventory ensures full IEC three-phase coverage alongside brown and black. Choosing KL-400LFGY in grey ensures your power distribution system follows established color conventions, speeding up setup and reducing wiring errors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs KL-400LFGY UL listed and what does that mean?\u003c\/h3\u003e\n    \u003cp\u003eYes. KL-400LFGY is cUL Listed under File Number E332947, meaning it has been independently tested and certified to UL 1691 safety standards by a Nationally Recognized Testing Laboratory. This certification is required for professional power distribution in most North American jurisdictions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat industries commonly use KL-400LFGY?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFGY is widely used in rental house and staging company inventories serving diverse entertainment clients. Its 400A \/ 600V AC\/DC rating, combined with CAM-type universal compatibility and grey phase coding, makes it a versatile choice across the entertainment, construction, and industrial sectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat makes KL-400LFGY easy to use during fast-paced setups?\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK tool-free design means KL-400LFGY can be assembled and disassembled without specialized equipment. The ribbed Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius provides a secure grip even with work gloves, and the alignment arrow guides correct mating orientation - cutting connection time on busy sets and stages.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Who should use KL-400LFGY and why?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Lighting technicians, electricians, and power distribution professionals working with 400A temporary power systems will benefit from KL-400LFGY. Its grey housing provides instant visual phase identification, while the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius ensures durability in demanding field conditions.\"}}, {\"@type\": \"Question\", \"name\": \"What voltage and amperage is KL-400LFGY rated for?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFGY carries a maximum rating of 400A and 600V AC\/DC. It accepts wire gauges from #6 to 4\/0 AWG, making it suitable for the conductor sizes typically used in 400-amp power distribution circuits.\"}}, {\"@type\": \"Question\", \"name\": \"Why choose the grey version of the K-LOK 400A female line connector?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Grey represents Phase C (L3) - and in some IEC applications, Neutral - under the international color code. Adding grey to the connector inventory ensures full IEC three-phase coverage alongside brown and black. Choosing KL-400LFGY in grey ensures your power distribution system follows established color conventions, speeding up setup and reducing wiring errors.\"}}, {\"@type\": \"Question\", \"name\": \"Is KL-400LFGY UL listed and what does that mean?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. KL-400LFGY is cUL Listed under File Number E332947, meaning it has been independently tested and certified to UL 1691 safety standards by a Nationally Recognized Testing Laboratory. This certification is required for professional power distribution in most North American jurisdictions.\"}}, {\"@type\": \"Question\", \"name\": \"What industries commonly use KL-400LFGY?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFGY is widely used in rental house and staging company inventories serving diverse entertainment clients. Its 400A \/ 600V AC\/DC rating, combined with CAM-type universal compatibility and grey phase coding, makes it a versatile choice across the entertainment, construction, and industrial sectors.\"}}, {\"@type\": \"Question\", \"name\": \"What makes KL-400LFGY easy to use during fast-paced setups?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The K-LOK tool-free design means KL-400LFGY can be assembled and disassembled without specialized equipment. The ribbed Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius provides a secure grip even with work gloves, and the alignment arrow guides correct mating orientation - cutting connection time on busy sets and stages.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400LFGY\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/KL-400LFGY%20Data%20Sheet.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download KL-400LFGY Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Inline Connector","offer_id":50208818790620,"sku":"KL-400LFGY","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400LFGY.jpg?v=1777362807"},{"product_id":"kl-400lfo","title":"KL-400LFO - K-LOK 400A Female CAM-Type Line Connector, Orange","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400LFO --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400LFO\" data-color=\"Orange\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Female Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eNon-conductive POM (Polyoxymethylene) retaining screw locks the brass contact firmly in position, eliminating accidental current paths for safer operation\u003c\/li\u003e\n      \u003cli\u003ePOM insulation sleeve adds heat resistance and structural strength to the contact assembly\u003c\/li\u003e\n      \u003cli\u003eRibbed Santoprene TPV housing provides a secure, slip-free grip even when wearing work gloves\u003c\/li\u003e\n      \u003cli\u003eAlignment arrow ensures correct orientation for fast, error-free mating every time\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding site conditions and extreme temperatures\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors with redundant cable retention\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing power infrastructure from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Female In-Line Connector intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400LFO | K-LOK 400A Single-Pole Line Connector, Female, Orange, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Female Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400LFO\",\n  \"mpn\": \"KL-400LFO\",\n  \"color\": \"Orange\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Female\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Orange\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"High-Leg Delta \/ Special Identification\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Retaining Screw Material\",\n      \"value\": \"POM (Polyoxymethylene), Non-conductive\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screws\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400LFO\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does KL-400LFO do and where is it typically used?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFO provides a safe, reliable single-pole female connection point for 400A circuits at up to 600V AC\/DC. As a line connector with orange color coding, it is commonly used in professional entertainment power distribution, temporary construction feeds, and industrial installations.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat are the electrical ratings of KL-400LFO?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFO is rated for 400 amperes maximum continuous current at 600V AC\/DC maximum. It accepts conductors from #6 to 4\/0 AWG (American Wire Gauge), with brass contacts delivering low-resistance connections for sustained high-current loads.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the orange housing on KL-400LFO signify?\u003c\/h3\u003e\n    \u003cp\u003eOrange is traditionally reserved for high-leg delta circuits and other specialty applications in North America. It provides an unmistakable visual warning that a conductor carries a voltage different from the standard phases - critical information for electricians working with delta transformer configurations. Color-coded connectors like KL-400LFO allow crews to visually verify correct phase wiring at a glance, which is especially valuable during fast-paced load-ins and load-outs.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety standards apply to KL-400LFO?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFO meets UL 1691 (Cam-Type, Locking-Type Separable Connectors), is cUL Listed under E332947, rated UL Enclosure Types 3R for weather resistance, carries a HB \/ UL94 flame class, and complies with RoHS hazardous substance restrictions. These certifications collectively ensure the connector is safe for professional use in entertainment and industrial environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhere is KL-400LFO commonly deployed?\u003c\/h3\u003e\n    \u003cp\u003eYou will find KL-400LFO at work in portable power distribution for emergency and disaster-response operations. The orange color coding and 400-amp capacity make it particularly well suited for multi-phase power distribution in professional settings.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What does KL-400LFO do and where is it typically used?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFO provides a safe, reliable single-pole female connection point for 400A circuits at up to 600V AC\/DC. As a line connector with orange color coding, it is commonly used in professional entertainment power distribution, temporary construction feeds, and industrial installations.\"}}, {\"@type\": \"Question\", \"name\": \"What are the electrical ratings of KL-400LFO?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFO is rated for 400 amperes maximum continuous current at 600V AC\/DC maximum. It accepts conductors from #6 to 4\/0 AWG (American Wire Gauge), with brass contacts delivering low-resistance connections for sustained high-current loads.\"}}, {\"@type\": \"Question\", \"name\": \"What does the orange housing on KL-400LFO signify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Orange is traditionally reserved for high-leg delta circuits and other specialty applications in North America. It provides an unmistakable visual warning that a conductor carries a voltage different from the standard phases - critical information for electricians working with delta transformer configurations. Color-coded connectors like KL-400LFO allow crews to visually verify correct phase wiring at a glance, which is especially valuable during fast-paced load-ins and load-outs.\"}}, {\"@type\": \"Question\", \"name\": \"What safety standards apply to KL-400LFO?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFO meets UL 1691 (Cam-Type, Locking-Type Separable Connectors), is cUL Listed under E332947, rated UL Enclosure Types 3R for weather resistance, carries a HB \/ UL94 flame class, and complies with RoHS hazardous substance restrictions. These certifications collectively ensure the connector is safe for professional use in entertainment and industrial environments.\"}}, {\"@type\": \"Question\", \"name\": \"Where is KL-400LFO commonly deployed?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"You will find KL-400LFO at work in portable power distribution for emergency and disaster-response operations. The orange color coding and 400-amp capacity make it particularly well suited for multi-phase power distribution in professional settings.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400LFO\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/KL-400LFO%20Data%20Sheet.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download KL-400LFO Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Inline Connector","offer_id":50208818823388,"sku":"KL-400LFO","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400LFO.jpg?v=1777362807"},{"product_id":"kl-400lfr","title":"KL-400LFR - K-LOK 400A Female CAM-Type Line Connector, Red","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400LFR --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400LFR\" data-color=\"Red\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Female Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eNon-conductive POM (Polyoxymethylene) retaining screw locks the brass contact firmly in position, eliminating accidental current paths for safer operation\u003c\/li\u003e\n      \u003cli\u003ePOM insulation sleeve adds heat resistance and structural strength to the contact assembly\u003c\/li\u003e\n      \u003cli\u003eRibbed Santoprene TPV housing provides a secure, slip-free grip even when wearing work gloves\u003c\/li\u003e\n      \u003cli\u003eAlignment arrow ensures correct orientation for fast, error-free mating every time\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding site conditions and extreme temperatures\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors with redundant cable retention\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing power infrastructure from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Female In-Line Connector intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400LFR | K-LOK 400A Single-Pole Line Connector, Female, Red, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Female Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400LFR\",\n  \"mpn\": \"KL-400LFR\",\n  \"color\": \"Red\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Female\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Red\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Phase B\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Retaining Screw Material\",\n      \"value\": \"POM (Polyoxymethylene), Non-conductive\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screws\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400LFR\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat kind of connector is KL-400LFR?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFR is a 400-ampere, 600V AC\/DC single-pole female inline cable connector from the KUPO K-LOK series. Finished in red, it belongs to the CAM-type connector family widely used across live events, film production, and temporary industrial power systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current can KL-400LFR safely carry?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFR is designed for a maximum continuous load of 400 amperes at up to 600V AC\/DC. The brass contacts and Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius work together to maintain safe operating temperatures even under sustained full-load conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does the red color coding on KL-400LFR help on a busy job site?\u003c\/h3\u003e\n    \u003cp\u003eOn a crowded set or event site, identifying conductors quickly is a safety essential. Red marks Phase B (L2) in North American wiring and Phase C (L3) under Chinese GB 50303 standards. It is one of the most visually distinctive colors on a busy job site, helping crews quickly trace the second phase conductor. The red KL-400LFR connector lets technicians trace circuits visually without needing to check labels or test equipment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety certifications does KL-400LFR hold?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFR is cUL Listed under File Number E332947, certified to UL 1691 - the Standard for Safety for Cam-Type, Locking-Type Separable Connectors. It carries a UL Enclosure Types 3R environment rating, HB \/ UL94 flame classification, and full RoHS (Restriction of Hazardous Substances) compliance.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eCan KL-400LFR work with connectors from other brands?\u003c\/h3\u003e\n    \u003cp\u003eAbsolutely. The K-LOK 400A series uses the industry-standard CAM-type interface, so KL-400LFR mates directly with compatible single-pole connectors regardless of manufacturer. This makes it easy to expand or upgrade your connector stock incrementally.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat housing material is used in KL-400LFR and why does it matter?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFR uses a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius. Santoprene TPV combines the flexibility of rubber with the processing advantages of thermoplastic, delivering excellent chemical resistance, UV stability, and durability under repeated mechanical stress - exactly what professional power connectors face on tour and on set.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What kind of connector is KL-400LFR?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFR is a 400-ampere, 600V AC\/DC single-pole female inline cable connector from the KUPO K-LOK series. Finished in red, it belongs to the CAM-type connector family widely used across live events, film production, and temporary industrial power systems.\"}}, {\"@type\": \"Question\", \"name\": \"How much current can KL-400LFR safely carry?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFR is designed for a maximum continuous load of 400 amperes at up to 600V AC\/DC. The brass contacts and Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius work together to maintain safe operating temperatures even under sustained full-load conditions.\"}}, {\"@type\": \"Question\", \"name\": \"How does the red color coding on KL-400LFR help on a busy job site?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"On a crowded set or event site, identifying conductors quickly is a safety essential. Red marks Phase B (L2) in North American wiring and Phase C (L3) under Chinese GB 50303 standards. It is one of the most visually distinctive colors on a busy job site, helping crews quickly trace the second phase conductor. The red KL-400LFR connector lets technicians trace circuits visually without needing to check labels or test equipment.\"}}, {\"@type\": \"Question\", \"name\": \"What safety certifications does KL-400LFR hold?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFR is cUL Listed under File Number E332947, certified to UL 1691 - the Standard for Safety for Cam-Type, Locking-Type Separable Connectors. It carries a UL Enclosure Types 3R environment rating, HB \/ UL94 flame classification, and full RoHS (Restriction of Hazardous Substances) compliance.\"}}, {\"@type\": \"Question\", \"name\": \"Can KL-400LFR work with connectors from other brands?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Absolutely. The K-LOK 400A series uses the industry-standard CAM-type interface, so KL-400LFR mates directly with compatible single-pole connectors regardless of manufacturer. This makes it easy to expand or upgrade your connector stock incrementally.\"}}, {\"@type\": \"Question\", \"name\": \"What housing material is used in KL-400LFR and why does it matter?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFR uses a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius. Santoprene TPV combines the flexibility of rubber with the processing advantages of thermoplastic, delivering excellent chemical resistance, UV stability, and durability under repeated mechanical stress - exactly what professional power connectors face on tour and on set.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400LFR\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/KL-400LFR%20Data%20Sheet.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download KL-400LFR Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Inline Connector","offer_id":50208818856156,"sku":"KL-400LFR","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400LFR.jpg?v=1777362808"},{"product_id":"kl-400lfw","title":"KL-400LFW - K-LOK 400A Female CAM-Type Line Connector, White","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400LFW --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400LFW\" data-color=\"White\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Female Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eNon-conductive POM (Polyoxymethylene) retaining screw locks the brass contact firmly in position, eliminating accidental current paths for safer operation\u003c\/li\u003e\n      \u003cli\u003ePOM insulation sleeve adds heat resistance and structural strength to the contact assembly\u003c\/li\u003e\n      \u003cli\u003eRibbed Santoprene TPV housing provides a secure, slip-free grip even when wearing work gloves\u003c\/li\u003e\n      \u003cli\u003eAlignment arrow ensures correct orientation for fast, error-free mating every time\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding site conditions and extreme temperatures\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors with redundant cable retention\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing power infrastructure from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Female In-Line Connector intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400LFW | K-LOK 400A Single-Pole Line Connector, Female, White, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Female Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400LFW\",\n  \"mpn\": \"KL-400LFW\",\n  \"color\": \"White\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Female\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"White\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Neutral\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Retaining Screw Material\",\n      \"value\": \"POM (Polyoxymethylene), Non-conductive\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screws\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400LFW\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does KL-400LFW do and where is it typically used?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFW provides a safe, reliable single-pole female connection point for 400A circuits at up to 600V AC\/DC. As a line connector with white color coding, it is commonly used in professional entertainment power distribution, temporary construction feeds, and industrial installations.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat are the electrical ratings of KL-400LFW?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFW is rated for 400 amperes maximum continuous current at 600V AC\/DC maximum. It accepts conductors from #6 to 4\/0 AWG (American Wire Gauge), with brass contacts delivering low-resistance connections for sustained high-current loads.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the white housing on KL-400LFW signify?\u003c\/h3\u003e\n    \u003cp\u003eWhite is universally recognized in North America as the Neutral conductor per NEC conventions. Using a dedicated white connector for neutral runs eliminates guesswork during setup and teardown, reducing the risk of miswired circuits. Color-coded connectors like KL-400LFW allow crews to visually verify correct phase wiring at a glance, which is especially valuable during fast-paced load-ins and load-outs.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety standards apply to KL-400LFW?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFW meets UL 1691 (Cam-Type, Locking-Type Separable Connectors), is cUL Listed under E332947, rated UL Enclosure Types 3R for weather resistance, carries a HB \/ UL94 flame class, and complies with RoHS hazardous substance restrictions. These certifications collectively ensure the connector is safe for professional use in entertainment and industrial environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhere is KL-400LFW commonly deployed?\u003c\/h3\u003e\n    \u003cp\u003eYou will find KL-400LFW at work in studio power distribution in recording, post-production, and live broadcast environments. The white color coding and 400-amp capacity make it particularly well suited for multi-phase power distribution in professional settings.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat makes KL-400LFW easy to use during fast-paced setups?\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK tool-free design means KL-400LFW can be assembled and disassembled without specialized equipment. The ribbed Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius provides a secure grip even with work gloves, and the alignment arrow guides correct mating orientation - cutting connection time on busy sets and stages.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What does KL-400LFW do and where is it typically used?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFW provides a safe, reliable single-pole female connection point for 400A circuits at up to 600V AC\/DC. As a line connector with white color coding, it is commonly used in professional entertainment power distribution, temporary construction feeds, and industrial installations.\"}}, {\"@type\": \"Question\", \"name\": \"What are the electrical ratings of KL-400LFW?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFW is rated for 400 amperes maximum continuous current at 600V AC\/DC maximum. It accepts conductors from #6 to 4\/0 AWG (American Wire Gauge), with brass contacts delivering low-resistance connections for sustained high-current loads.\"}}, {\"@type\": \"Question\", \"name\": \"What does the white housing on KL-400LFW signify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"White is universally recognized in North America as the Neutral conductor per NEC conventions. Using a dedicated white connector for neutral runs eliminates guesswork during setup and teardown, reducing the risk of miswired circuits. Color-coded connectors like KL-400LFW allow crews to visually verify correct phase wiring at a glance, which is especially valuable during fast-paced load-ins and load-outs.\"}}, {\"@type\": \"Question\", \"name\": \"What safety standards apply to KL-400LFW?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFW meets UL 1691 (Cam-Type, Locking-Type Separable Connectors), is cUL Listed under E332947, rated UL Enclosure Types 3R for weather resistance, carries a HB \/ UL94 flame class, and complies with RoHS hazardous substance restrictions. These certifications collectively ensure the connector is safe for professional use in entertainment and industrial environments.\"}}, {\"@type\": \"Question\", \"name\": \"Where is KL-400LFW commonly deployed?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"You will find KL-400LFW at work in studio power distribution in recording, post-production, and live broadcast environments. The white color coding and 400-amp capacity make it particularly well suited for multi-phase power distribution in professional settings.\"}}, {\"@type\": \"Question\", \"name\": \"What makes KL-400LFW easy to use during fast-paced setups?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The K-LOK tool-free design means KL-400LFW can be assembled and disassembled without specialized equipment. The ribbed Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius provides a secure grip even with work gloves, and the alignment arrow guides correct mating orientation - cutting connection time on busy sets and stages.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400LFW\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/KL-400LFW%20Data%20Sheet.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download KL-400LFW Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Inline Connector","offer_id":50208818888924,"sku":"KL-400LFW","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400LFW.jpg?v=1777362809"},{"product_id":"kl-400lfy","title":"KL-400LFY - K-LOK 400A Female CAM-Type Line Connector, Yellow","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400LFY --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400LFY\" data-color=\"Yellow\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Female Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eNon-conductive POM (Polyoxymethylene) retaining screw locks the brass contact firmly in position, eliminating accidental current paths for safer operation\u003c\/li\u003e\n      \u003cli\u003ePOM insulation sleeve adds heat resistance and structural strength to the contact assembly\u003c\/li\u003e\n      \u003cli\u003eRibbed Santoprene TPV housing provides a secure, slip-free grip even when wearing work gloves\u003c\/li\u003e\n      \u003cli\u003eAlignment arrow ensures correct orientation for fast, error-free mating every time\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding site conditions and extreme temperatures\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors with redundant cable retention\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing power infrastructure from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Female In-Line Connector intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400LFY | K-LOK 400A Single-Pole Line Connector, Female, Yellow, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Female Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400LFY\",\n  \"mpn\": \"KL-400LFY\",\n  \"color\": \"Yellow\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Female\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Yellow\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Phase A (China GB 50303)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Retaining Screw Material\",\n      \"value\": \"POM (Polyoxymethylene), Non-conductive\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screws\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400LFY\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is KL-400LFY and what is it designed for?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFY is a KUPO K-LOK 400A single-pole female inline cable connector with a yellow housing, rated for 600V AC\/DC maximum. It is engineered for heavy-duty temporary power distribution in entertainment, industrial, and event production settings. The yellow color coding aids rapid phase identification on the job site.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat wire sizes does KL-400LFY accept?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFY accommodates conductors ranging from #6 to 4\/0 AWG. The brass contact assembly ensures reliable electrical performance across this full conductor range, supporting up to 400A at 600V AC\/DC.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhich electrical phase does the yellow color represent on KL-400LFY?\u003c\/h3\u003e\n    \u003cp\u003eYellow identifies Phase A (L1) under China's GB 50303 standard and is also used for specialty marking in some North American installations. Its high-visibility color makes it an excellent choice for circuits that need to stand out for safety or identification purposes. Having a dedicated yellow connector in your inventory means phase assignments are physically enforced, minimizing the chance of cross-phase connection errors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does KL-400LFY protect against electrical hazards?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFY incorporates multiple safety features: the non-conductive POM retaining screw prevents accidental current paths through the housing, the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius resists heat and impact, brass contacts minimize resistive heating, and the design meets UL 1691 safety requirements under cUL Listed E332947. The UL Enclosure Types 3R rating also provides protection in wet or outdoor conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs KL-400LFY compatible with other CAM-type connectors?\u003c\/h3\u003e\n    \u003cp\u003eYes. KL-400LFY follows the universal CAM-type single-pole connector standard and intermates with CAM-type connectors from all major manufacturers. This cross-brand compatibility means you can integrate K-LOK connectors into existing power distribution systems without replacing your entire inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow do you assemble KL-400LFY in the field?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFY features a tool-free modular design that enables rapid assembly and disassembly on site. Strip the cable, insert it through the housing, secure it with the double set screw termination, and lock the brass contact in place with the non-conductive POM retaining screw. The alignment arrow ensures correct orientation every time.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is KL-400LFY and what is it designed for?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFY is a KUPO K-LOK 400A single-pole female inline cable connector with a yellow housing, rated for 600V AC\/DC maximum. It is engineered for heavy-duty temporary power distribution in entertainment, industrial, and event production settings. The yellow color coding aids rapid phase identification on the job site.\"}}, {\"@type\": \"Question\", \"name\": \"What wire sizes does KL-400LFY accept?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFY accommodates conductors ranging from #6 to 4\/0 AWG. The brass contact assembly ensures reliable electrical performance across this full conductor range, supporting up to 400A at 600V AC\/DC.\"}}, {\"@type\": \"Question\", \"name\": \"Which electrical phase does the yellow color represent on KL-400LFY?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yellow identifies Phase A (L1) under China's GB 50303 standard and is also used for specialty marking in some North American installations. Its high-visibility color makes it an excellent choice for circuits that need to stand out for safety or identification purposes. Having a dedicated yellow connector in your inventory means phase assignments are physically enforced, minimizing the chance of cross-phase connection errors.\"}}, {\"@type\": \"Question\", \"name\": \"How does KL-400LFY protect against electrical hazards?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFY incorporates multiple safety features: the non-conductive POM retaining screw prevents accidental current paths through the housing, the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius resists heat and impact, brass contacts minimize resistive heating, and the design meets UL 1691 safety requirements under cUL Listed E332947. The UL Enclosure Types 3R rating also provides protection in wet or outdoor conditions.\"}}, {\"@type\": \"Question\", \"name\": \"Is KL-400LFY compatible with other CAM-type connectors?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. KL-400LFY follows the universal CAM-type single-pole connector standard and intermates with CAM-type connectors from all major manufacturers. This cross-brand compatibility means you can integrate K-LOK connectors into existing power distribution systems without replacing your entire inventory.\"}}, {\"@type\": \"Question\", \"name\": \"How do you assemble KL-400LFY in the field?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFY features a tool-free modular design that enables rapid assembly and disassembly on site. Strip the cable, insert it through the housing, secure it with the double set screw termination, and lock the brass contact in place with the non-conductive POM retaining screw. The alignment arrow ensures correct orientation every time.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400LFY\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/KL-400LFY%20Data%20Sheet.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download KL-400LFY Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Inline Connector","offer_id":50208818921692,"sku":"KL-400LFY","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400LFY.jpg?v=1777362810"},{"product_id":"kl-400lmb","title":"KL-400LMB - K-LOK 400A Male CAM-Type Line Connector, Blue","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400LMB --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400LMB\" data-color=\"Blue\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Male Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eNon-conductive POM (Polyoxymethylene) retaining screw locks the brass contact firmly in position, eliminating accidental current paths for safer operation\u003c\/li\u003e\n      \u003cli\u003ePOM insulation sleeve adds heat resistance and structural strength to the contact assembly\u003c\/li\u003e\n      \u003cli\u003eRibbed Santoprene TPV housing provides a secure, slip-free grip even when wearing work gloves\u003c\/li\u003e\n      \u003cli\u003eAlignment arrow ensures correct orientation for fast, error-free mating every time\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding site conditions and extreme temperatures\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors with redundant cable retention\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing power infrastructure from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Male In-Line Connector intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400LMB | K-LOK 400A Single-Pole Line Connector, Male, Blue, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Male Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400LMB\",\n  \"mpn\": \"KL-400LMB\",\n  \"color\": \"Blue\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Male\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Blue\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Phase C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Retaining Screw Material\",\n      \"value\": \"POM (Polyoxymethylene), Non-conductive\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screws\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400LMB\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does KL-400LMB do and where is it typically used?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMB provides a safe, reliable single-pole male connection point for 400A circuits at up to 600V AC\/DC. As a line connector with blue color coding, it is commonly used in professional entertainment power distribution, temporary construction feeds, and industrial installations.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat are the electrical ratings of KL-400LMB?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMB is rated for 400 amperes maximum continuous current at 600V AC\/DC maximum. It accepts conductors from #6 to 4\/0 AWG (American Wire Gauge), with brass contacts delivering low-resistance connections for sustained high-current loads.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the blue housing on KL-400LMB signify?\u003c\/h3\u003e\n    \u003cp\u003eIn North America, blue designates Phase C (L3), completing the three-phase color set. Under IEC 60446, blue is reserved for the Neutral conductor - making this color essential for international projects and cross-border equipment pools. Color-coded connectors like KL-400LMB allow crews to visually verify correct phase wiring at a glance, which is especially valuable during fast-paced load-ins and load-outs.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety standards apply to KL-400LMB?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMB meets UL 1691 (Cam-Type, Locking-Type Separable Connectors), is cUL Listed under E332947, rated UL Enclosure Types 3R for weather resistance, carries a HB \/ UL94 flame class, and complies with RoHS hazardous substance restrictions. These certifications collectively ensure the connector is safe for professional use in entertainment and industrial environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhere is KL-400LMB commonly deployed?\u003c\/h3\u003e\n    \u003cp\u003eYou will find KL-400LMB at work in trade shows and exhibition installations that demand professional-grade temporary power. The blue color coding and 400-amp capacity make it particularly well suited for multi-phase power distribution in professional settings.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow do you assemble KL-400LMB in the field?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMB features a tool-free modular design that enables rapid assembly and disassembly on site. Strip the cable, insert it through the housing, secure it with the double set screw termination, and lock the brass contact in place with the non-conductive POM retaining screw. The alignment arrow ensures correct orientation every time.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What does KL-400LMB do and where is it typically used?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMB provides a safe, reliable single-pole male connection point for 400A circuits at up to 600V AC\/DC. As a line connector with blue color coding, it is commonly used in professional entertainment power distribution, temporary construction feeds, and industrial installations.\"}}, {\"@type\": \"Question\", \"name\": \"What are the electrical ratings of KL-400LMB?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMB is rated for 400 amperes maximum continuous current at 600V AC\/DC maximum. It accepts conductors from #6 to 4\/0 AWG (American Wire Gauge), with brass contacts delivering low-resistance connections for sustained high-current loads.\"}}, {\"@type\": \"Question\", \"name\": \"What does the blue housing on KL-400LMB signify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"In North America, blue designates Phase C (L3), completing the three-phase color set. Under IEC 60446, blue is reserved for the Neutral conductor - making this color essential for international projects and cross-border equipment pools. Color-coded connectors like KL-400LMB allow crews to visually verify correct phase wiring at a glance, which is especially valuable during fast-paced load-ins and load-outs.\"}}, {\"@type\": \"Question\", \"name\": \"What safety standards apply to KL-400LMB?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMB meets UL 1691 (Cam-Type, Locking-Type Separable Connectors), is cUL Listed under E332947, rated UL Enclosure Types 3R for weather resistance, carries a HB \/ UL94 flame class, and complies with RoHS hazardous substance restrictions. These certifications collectively ensure the connector is safe for professional use in entertainment and industrial environments.\"}}, {\"@type\": \"Question\", \"name\": \"Where is KL-400LMB commonly deployed?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"You will find KL-400LMB at work in trade shows and exhibition installations that demand professional-grade temporary power. The blue color coding and 400-amp capacity make it particularly well suited for multi-phase power distribution in professional settings.\"}}, {\"@type\": \"Question\", \"name\": \"How do you assemble KL-400LMB in the field?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMB features a tool-free modular design that enables rapid assembly and disassembly on site. Strip the cable, insert it through the housing, secure it with the double set screw termination, and lock the brass contact in place with the non-conductive POM retaining screw. The alignment arrow ensures correct orientation every time.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400LMB\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/KL-400LMB%20Data%20Sheet.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download KL-400LMB Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Inline Connector","offer_id":50208819642588,"sku":"KL-400LMB","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400LMB.jpg?v=1777362811"},{"product_id":"kl-400lmbk","title":"KL-400LMBK - K-LOK 400A Male CAM-Type Line Connector, Black","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400LMBK --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400LMBK\" data-color=\"Black\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Male Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eNon-conductive POM (Polyoxymethylene) retaining screw locks the brass contact firmly in position, eliminating accidental current paths for safer operation\u003c\/li\u003e\n      \u003cli\u003ePOM insulation sleeve adds heat resistance and structural strength to the contact assembly\u003c\/li\u003e\n      \u003cli\u003eRibbed Santoprene TPV housing provides a secure, slip-free grip even when wearing work gloves\u003c\/li\u003e\n      \u003cli\u003eAlignment arrow ensures correct orientation for fast, error-free mating every time\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding site conditions and extreme temperatures\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors with redundant cable retention\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing power infrastructure from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Male In-Line Connector intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400LMBK | K-LOK 400A Single-Pole Line Connector, Male, Black, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Male Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400LMBK\",\n  \"mpn\": \"KL-400LMBK\",\n  \"color\": \"Black\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Male\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Black\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Phase A \/ General\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Retaining Screw Material\",\n      \"value\": \"POM (Polyoxymethylene), Non-conductive\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screws\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400LMBK\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat kind of connector is KL-400LMBK?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMBK is a 400-ampere, 600V AC\/DC single-pole male inline cable connector from the KUPO K-LOK series. Finished in black, it belongs to the CAM-type connector family widely used across live events, film production, and temporary industrial power systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current can KL-400LMBK safely carry?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMBK is designed for a maximum continuous load of 400 amperes at up to 600V AC\/DC. The brass contacts and Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius work together to maintain safe operating temperatures even under sustained full-load conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does the black color coding on KL-400LMBK help on a busy job site?\u003c\/h3\u003e\n    \u003cp\u003eOn a crowded set or event site, identifying conductors quickly is a safety essential. Under North American NEMA\/NEC conventions, black identifies Phase A (L1), making it the go-to choice for single-phase circuits and the default lead in three-phase systems. In IEC regions, black denotes Phase B (L2). The black KL-400LMBK connector lets technicians trace circuits visually without needing to check labels or test equipment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety certifications does KL-400LMBK hold?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMBK is cUL Listed under File Number E332947, certified to UL 1691 - the Standard for Safety for Cam-Type, Locking-Type Separable Connectors. It carries a UL Enclosure Types 3R environment rating, HB \/ UL94 flame classification, and full RoHS (Restriction of Hazardous Substances) compliance.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eCan KL-400LMBK work with connectors from other brands?\u003c\/h3\u003e\n    \u003cp\u003eAbsolutely. The K-LOK 400A series uses the industry-standard CAM-type interface, so KL-400LMBK mates directly with compatible single-pole connectors regardless of manufacturer. This makes it easy to expand or upgrade your connector stock incrementally.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat makes KL-400LMBK easy to use during fast-paced setups?\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK tool-free design means KL-400LMBK can be assembled and disassembled without specialized equipment. The ribbed Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius provides a secure grip even with work gloves, and the alignment arrow guides correct mating orientation - cutting connection time on busy sets and stages.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What kind of connector is KL-400LMBK?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMBK is a 400-ampere, 600V AC\/DC single-pole male inline cable connector from the KUPO K-LOK series. Finished in black, it belongs to the CAM-type connector family widely used across live events, film production, and temporary industrial power systems.\"}}, {\"@type\": \"Question\", \"name\": \"How much current can KL-400LMBK safely carry?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMBK is designed for a maximum continuous load of 400 amperes at up to 600V AC\/DC. The brass contacts and Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius work together to maintain safe operating temperatures even under sustained full-load conditions.\"}}, {\"@type\": \"Question\", \"name\": \"How does the black color coding on KL-400LMBK help on a busy job site?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"On a crowded set or event site, identifying conductors quickly is a safety essential. Under North American NEMA\/NEC conventions, black identifies Phase A (L1), making it the go-to choice for single-phase circuits and the default lead in three-phase systems. In IEC regions, black denotes Phase B (L2). The black KL-400LMBK connector lets technicians trace circuits visually without needing to check labels or test equipment.\"}}, {\"@type\": \"Question\", \"name\": \"What safety certifications does KL-400LMBK hold?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMBK is cUL Listed under File Number E332947, certified to UL 1691 - the Standard for Safety for Cam-Type, Locking-Type Separable Connectors. It carries a UL Enclosure Types 3R environment rating, HB \/ UL94 flame classification, and full RoHS (Restriction of Hazardous Substances) compliance.\"}}, {\"@type\": \"Question\", \"name\": \"Can KL-400LMBK work with connectors from other brands?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Absolutely. The K-LOK 400A series uses the industry-standard CAM-type interface, so KL-400LMBK mates directly with compatible single-pole connectors regardless of manufacturer. This makes it easy to expand or upgrade your connector stock incrementally.\"}}, {\"@type\": \"Question\", \"name\": \"What makes KL-400LMBK easy to use during fast-paced setups?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The K-LOK tool-free design means KL-400LMBK can be assembled and disassembled without specialized equipment. The ribbed Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius provides a secure grip even with work gloves, and the alignment arrow guides correct mating orientation - cutting connection time on busy sets and stages.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400LMBK\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/KL-400LMBK%20Data%20Sheet.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download KL-400LMBK Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Inline Connector","offer_id":50208819675356,"sku":"KL-400LMBK","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400LMBK.jpg?v=1777362811"},{"product_id":"kl-400lmbn","title":"KL-400LMBN - K-LOK 400A Male CAM-Type Line Connector, Brown","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400LMBN --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400LMBN\" data-color=\"Brown\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Male Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eNon-conductive POM (Polyoxymethylene) retaining screw locks the brass contact firmly in position, eliminating accidental current paths for safer operation\u003c\/li\u003e\n      \u003cli\u003ePOM insulation sleeve adds heat resistance and structural strength to the contact assembly\u003c\/li\u003e\n      \u003cli\u003eRibbed Santoprene TPV housing provides a secure, slip-free grip even when wearing work gloves\u003c\/li\u003e\n      \u003cli\u003eAlignment arrow ensures correct orientation for fast, error-free mating every time\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding site conditions and extreme temperatures\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors with redundant cable retention\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing power infrastructure from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Male In-Line Connector intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400LMBN | K-LOK 400A Single-Pole Line Connector, Male, Brown, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Male Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400LMBN\",\n  \"mpn\": \"KL-400LMBN\",\n  \"color\": \"Brown\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Male\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Brown\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Phase A (IEC)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Retaining Screw Material\",\n      \"value\": \"POM (Polyoxymethylene), Non-conductive\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screws\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400LMBN\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWho should use KL-400LMBN and why?\u003c\/h3\u003e\n    \u003cp\u003eLighting technicians, electricians, and power distribution professionals working with 400A temporary power systems will benefit from KL-400LMBN. Its brown housing provides instant visual phase identification, while the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius ensures durability in demanding field conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat voltage and amperage is KL-400LMBN rated for?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMBN carries a maximum rating of 400A and 600V AC\/DC. It accepts wire gauges from #6 to 4\/0 AWG, making it suitable for the conductor sizes typically used in 400-amp power distribution circuits.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhy choose the brown version of the K-LOK 400A male line connector?\u003c\/h3\u003e\n    \u003cp\u003eBrown designates Phase A (L1) under IEC 60446 conventions used across Europe, the UK, Asia, and Australia. For productions touring internationally or venues hosting global acts, brown connectors ensure IEC-standard phase identification is always available. Choosing KL-400LMBN in brown ensures your power distribution system follows established color conventions, speeding up setup and reducing wiring errors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs KL-400LMBN UL listed and what does that mean?\u003c\/h3\u003e\n    \u003cp\u003eYes. KL-400LMBN is cUL Listed under File Number E332947, meaning it has been independently tested and certified to UL 1691 safety standards by a Nationally Recognized Testing Laboratory. This certification is required for professional power distribution in most North American jurisdictions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat industries commonly use KL-400LMBN?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMBN is widely used in industrial temporary power connections for manufacturing and processing facilities. Its 400A \/ 600V AC\/DC rating, combined with CAM-type universal compatibility and brown phase coding, makes it a versatile choice across the entertainment, construction, and industrial sectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow do you assemble KL-400LMBN in the field?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMBN features a tool-free modular design that enables rapid assembly and disassembly on site. Strip the cable, insert it through the housing, secure it with the double set screw termination, and lock the brass contact in place with the non-conductive POM retaining screw. The alignment arrow ensures correct orientation every time.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Who should use KL-400LMBN and why?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Lighting technicians, electricians, and power distribution professionals working with 400A temporary power systems will benefit from KL-400LMBN. Its brown housing provides instant visual phase identification, while the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius ensures durability in demanding field conditions.\"}}, {\"@type\": \"Question\", \"name\": \"What voltage and amperage is KL-400LMBN rated for?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMBN carries a maximum rating of 400A and 600V AC\/DC. It accepts wire gauges from #6 to 4\/0 AWG, making it suitable for the conductor sizes typically used in 400-amp power distribution circuits.\"}}, {\"@type\": \"Question\", \"name\": \"Why choose the brown version of the K-LOK 400A male line connector?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Brown designates Phase A (L1) under IEC 60446 conventions used across Europe, the UK, Asia, and Australia. For productions touring internationally or venues hosting global acts, brown connectors ensure IEC-standard phase identification is always available. Choosing KL-400LMBN in brown ensures your power distribution system follows established color conventions, speeding up setup and reducing wiring errors.\"}}, {\"@type\": \"Question\", \"name\": \"Is KL-400LMBN UL listed and what does that mean?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. KL-400LMBN is cUL Listed under File Number E332947, meaning it has been independently tested and certified to UL 1691 safety standards by a Nationally Recognized Testing Laboratory. This certification is required for professional power distribution in most North American jurisdictions.\"}}, {\"@type\": \"Question\", \"name\": \"What industries commonly use KL-400LMBN?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMBN is widely used in industrial temporary power connections for manufacturing and processing facilities. Its 400A \/ 600V AC\/DC rating, combined with CAM-type universal compatibility and brown phase coding, makes it a versatile choice across the entertainment, construction, and industrial sectors.\"}}, {\"@type\": \"Question\", \"name\": \"How do you assemble KL-400LMBN in the field?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMBN features a tool-free modular design that enables rapid assembly and disassembly on site. Strip the cable, insert it through the housing, secure it with the double set screw termination, and lock the brass contact in place with the non-conductive POM retaining screw. The alignment arrow ensures correct orientation every time.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400LMBN\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/KL-400LMBN%20Data%20Sheet.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download KL-400LMBN Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Inline Connector","offer_id":50208819708124,"sku":"KL-400LMBN","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400LMBN.jpg?v=1777362812"},{"product_id":"kl-400lmg","title":"KL-400LMG - K-LOK 400A Male CAM-Type Line Connector, Green","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400LMG --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400LMG\" data-color=\"Green\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Male Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eNon-conductive POM (Polyoxymethylene) retaining screw locks the brass contact firmly in position, eliminating accidental current paths for safer operation\u003c\/li\u003e\n      \u003cli\u003ePOM insulation sleeve adds heat resistance and structural strength to the contact assembly\u003c\/li\u003e\n      \u003cli\u003eRibbed Santoprene TPV housing provides a secure, slip-free grip even when wearing work gloves\u003c\/li\u003e\n      \u003cli\u003eAlignment arrow ensures correct orientation for fast, error-free mating every time\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding site conditions and extreme temperatures\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors with redundant cable retention\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing power infrastructure from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Male In-Line Connector intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400LMG | K-LOK 400A Single-Pole Line Connector, Male, Green, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Male Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400LMG\",\n  \"mpn\": \"KL-400LMG\",\n  \"color\": \"Green\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Male\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Green\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Ground \/ Earth\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Retaining Screw Material\",\n      \"value\": \"POM (Polyoxymethylene), Non-conductive\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screws\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400LMG\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat kind of connector is KL-400LMG?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMG is a 400-ampere, 600V AC\/DC single-pole male inline cable connector from the KUPO K-LOK series. Finished in green, it belongs to the CAM-type connector family widely used across live events, film production, and temporary industrial power systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current can KL-400LMG safely carry?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMG is designed for a maximum continuous load of 400 amperes at up to 600V AC\/DC. The brass contacts and Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius work together to maintain safe operating temperatures even under sustained full-load conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does the green color coding on KL-400LMG help on a busy job site?\u003c\/h3\u003e\n    \u003cp\u003eOn a crowded set or event site, identifying conductors quickly is a safety essential. Green identifies the Ground (Earth \/ PE) conductor across North American and many international standards. Ground integrity is critical for personnel safety, and a distinct green connector ensures the safety earth is never confused with a current-carrying phase. The green KL-400LMG connector lets technicians trace circuits visually without needing to check labels or test equipment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety certifications does KL-400LMG hold?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMG is cUL Listed under File Number E332947, certified to UL 1691 - the Standard for Safety for Cam-Type, Locking-Type Separable Connectors. It carries a UL Enclosure Types 3R environment rating, HB \/ UL94 flame classification, and full RoHS (Restriction of Hazardous Substances) compliance.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eCan KL-400LMG work with connectors from other brands?\u003c\/h3\u003e\n    \u003cp\u003eAbsolutely. The K-LOK 400A series uses the industry-standard CAM-type interface, so KL-400LMG mates directly with compatible single-pole connectors regardless of manufacturer. This makes it easy to expand or upgrade your connector stock incrementally.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat housing material is used in KL-400LMG and why does it matter?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMG uses a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius. Santoprene TPV combines the flexibility of rubber with the processing advantages of thermoplastic, delivering excellent chemical resistance, UV stability, and durability under repeated mechanical stress - exactly what professional power connectors face on tour and on set.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What kind of connector is KL-400LMG?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMG is a 400-ampere, 600V AC\/DC single-pole male inline cable connector from the KUPO K-LOK series. Finished in green, it belongs to the CAM-type connector family widely used across live events, film production, and temporary industrial power systems.\"}}, {\"@type\": \"Question\", \"name\": \"How much current can KL-400LMG safely carry?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMG is designed for a maximum continuous load of 400 amperes at up to 600V AC\/DC. The brass contacts and Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius work together to maintain safe operating temperatures even under sustained full-load conditions.\"}}, {\"@type\": \"Question\", \"name\": \"How does the green color coding on KL-400LMG help on a busy job site?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"On a crowded set or event site, identifying conductors quickly is a safety essential. Green identifies the Ground (Earth \/ PE) conductor across North American and many international standards. Ground integrity is critical for personnel safety, and a distinct green connector ensures the safety earth is never confused with a current-carrying phase. The green KL-400LMG connector lets technicians trace circuits visually without needing to check labels or test equipment.\"}}, {\"@type\": \"Question\", \"name\": \"What safety certifications does KL-400LMG hold?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMG is cUL Listed under File Number E332947, certified to UL 1691 - the Standard for Safety for Cam-Type, Locking-Type Separable Connectors. It carries a UL Enclosure Types 3R environment rating, HB \/ UL94 flame classification, and full RoHS (Restriction of Hazardous Substances) compliance.\"}}, {\"@type\": \"Question\", \"name\": \"Can KL-400LMG work with connectors from other brands?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Absolutely. The K-LOK 400A series uses the industry-standard CAM-type interface, so KL-400LMG mates directly with compatible single-pole connectors regardless of manufacturer. This makes it easy to expand or upgrade your connector stock incrementally.\"}}, {\"@type\": \"Question\", \"name\": \"What housing material is used in KL-400LMG and why does it matter?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMG uses a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius. Santoprene TPV combines the flexibility of rubber with the processing advantages of thermoplastic, delivering excellent chemical resistance, UV stability, and durability under repeated mechanical stress - exactly what professional power connectors face on tour and on set.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400LMG\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/KL-400LMG%20Data%20Sheet.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download KL-400LMG Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Inline Connector","offer_id":50208819740892,"sku":"KL-400LMG","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400LMG.jpg?v=1777362813"},{"product_id":"kl-400lmgy","title":"KL-400LMGY - K-LOK 400A Male CAM-Type Line Connector, Grey","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400LMGY --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400LMGY\" data-color=\"Grey\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Male Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eNon-conductive POM (Polyoxymethylene) retaining screw locks the brass contact firmly in position, eliminating accidental current paths for safer operation\u003c\/li\u003e\n      \u003cli\u003ePOM insulation sleeve adds heat resistance and structural strength to the contact assembly\u003c\/li\u003e\n      \u003cli\u003eRibbed Santoprene TPV housing provides a secure, slip-free grip even when wearing work gloves\u003c\/li\u003e\n      \u003cli\u003eAlignment arrow ensures correct orientation for fast, error-free mating every time\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding site conditions and extreme temperatures\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors with redundant cable retention\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing power infrastructure from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Male In-Line Connector intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400LMGY | K-LOK 400A Single-Pole Line Connector, Male, Grey, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Male Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400LMGY\",\n  \"mpn\": \"KL-400LMGY\",\n  \"color\": \"Grey\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Male\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Grey\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Neutral (IEC)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Retaining Screw Material\",\n      \"value\": \"POM (Polyoxymethylene), Non-conductive\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screws\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400LMGY\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does KL-400LMGY do and where is it typically used?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMGY provides a safe, reliable single-pole male connection point for 400A circuits at up to 600V AC\/DC. As a line connector with grey color coding, it is commonly used in professional entertainment power distribution, temporary construction feeds, and industrial installations.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat are the electrical ratings of KL-400LMGY?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMGY is rated for 400 amperes maximum continuous current at 600V AC\/DC maximum. It accepts conductors from #6 to 4\/0 AWG (American Wire Gauge), with brass contacts delivering low-resistance connections for sustained high-current loads.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the grey housing on KL-400LMGY signify?\u003c\/h3\u003e\n    \u003cp\u003eGrey represents Phase C (L3) - and in some IEC applications, Neutral - under the international color code. Adding grey to the connector inventory ensures full IEC three-phase coverage alongside brown and black. Color-coded connectors like KL-400LMGY allow crews to visually verify correct phase wiring at a glance, which is especially valuable during fast-paced load-ins and load-outs.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety standards apply to KL-400LMGY?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMGY meets UL 1691 (Cam-Type, Locking-Type Separable Connectors), is cUL Listed under E332947, rated UL Enclosure Types 3R for weather resistance, carries a HB \/ UL94 flame class, and complies with RoHS hazardous substance restrictions. These certifications collectively ensure the connector is safe for professional use in entertainment and industrial environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhere is KL-400LMGY commonly deployed?\u003c\/h3\u003e\n    \u003cp\u003eYou will find KL-400LMGY at work in studio power distribution in recording, post-production, and live broadcast environments. The grey color coding and 400-amp capacity make it particularly well suited for multi-phase power distribution in professional settings.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat makes KL-400LMGY easy to use during fast-paced setups?\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK tool-free design means KL-400LMGY can be assembled and disassembled without specialized equipment. The ribbed Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius provides a secure grip even with work gloves, and the alignment arrow guides correct mating orientation - cutting connection time on busy sets and stages.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What does KL-400LMGY do and where is it typically used?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMGY provides a safe, reliable single-pole male connection point for 400A circuits at up to 600V AC\/DC. As a line connector with grey color coding, it is commonly used in professional entertainment power distribution, temporary construction feeds, and industrial installations.\"}}, {\"@type\": \"Question\", \"name\": \"What are the electrical ratings of KL-400LMGY?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMGY is rated for 400 amperes maximum continuous current at 600V AC\/DC maximum. It accepts conductors from #6 to 4\/0 AWG (American Wire Gauge), with brass contacts delivering low-resistance connections for sustained high-current loads.\"}}, {\"@type\": \"Question\", \"name\": \"What does the grey housing on KL-400LMGY signify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Grey represents Phase C (L3) - and in some IEC applications, Neutral - under the international color code. Adding grey to the connector inventory ensures full IEC three-phase coverage alongside brown and black. Color-coded connectors like KL-400LMGY allow crews to visually verify correct phase wiring at a glance, which is especially valuable during fast-paced load-ins and load-outs.\"}}, {\"@type\": \"Question\", \"name\": \"What safety standards apply to KL-400LMGY?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMGY meets UL 1691 (Cam-Type, Locking-Type Separable Connectors), is cUL Listed under E332947, rated UL Enclosure Types 3R for weather resistance, carries a HB \/ UL94 flame class, and complies with RoHS hazardous substance restrictions. These certifications collectively ensure the connector is safe for professional use in entertainment and industrial environments.\"}}, {\"@type\": \"Question\", \"name\": \"Where is KL-400LMGY commonly deployed?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"You will find KL-400LMGY at work in studio power distribution in recording, post-production, and live broadcast environments. The grey color coding and 400-amp capacity make it particularly well suited for multi-phase power distribution in professional settings.\"}}, {\"@type\": \"Question\", \"name\": \"What makes KL-400LMGY easy to use during fast-paced setups?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The K-LOK tool-free design means KL-400LMGY can be assembled and disassembled without specialized equipment. The ribbed Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius provides a secure grip even with work gloves, and the alignment arrow guides correct mating orientation - cutting connection time on busy sets and stages.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400LMGY\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/KL-400LMGY%20Data%20Sheet.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download KL-400LMGY Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Inline Connector","offer_id":50208819773660,"sku":"KL-400LMGY","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400LMGY.jpg?v=1777362814"},{"product_id":"kl-400lmo","title":"KL-400LMO - K-LOK 400A Male CAM-Type Line Connector, Orange","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400LMO --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400LMO\" data-color=\"Orange\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Male Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eNon-conductive POM (Polyoxymethylene) retaining screw locks the brass contact firmly in position, eliminating accidental current paths for safer operation\u003c\/li\u003e\n      \u003cli\u003ePOM insulation sleeve adds heat resistance and structural strength to the contact assembly\u003c\/li\u003e\n      \u003cli\u003eRibbed Santoprene TPV housing provides a secure, slip-free grip even when wearing work gloves\u003c\/li\u003e\n      \u003cli\u003eAlignment arrow ensures correct orientation for fast, error-free mating every time\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding site conditions and extreme temperatures\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors with redundant cable retention\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing power infrastructure from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Male In-Line Connector intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400LMO | K-LOK 400A Single-Pole Line Connector, Male, Orange, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Male Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400LMO\",\n  \"mpn\": \"KL-400LMO\",\n  \"color\": \"Orange\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Male\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Orange\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"High-Leg Delta \/ Special Identification\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Retaining Screw Material\",\n      \"value\": \"POM (Polyoxymethylene), Non-conductive\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screws\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400LMO\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is KL-400LMO and what is it designed for?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMO is a KUPO K-LOK 400A single-pole male inline cable connector with a orange housing, rated for 600V AC\/DC maximum. It is engineered for heavy-duty temporary power distribution in entertainment, industrial, and event production settings. The orange color coding aids rapid phase identification on the job site.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat wire sizes does KL-400LMO accept?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMO accommodates conductors ranging from #6 to 4\/0 AWG. The brass contact assembly ensures reliable electrical performance across this full conductor range, supporting up to 400A at 600V AC\/DC.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhich electrical phase does the orange color represent on KL-400LMO?\u003c\/h3\u003e\n    \u003cp\u003eOrange is traditionally reserved for high-leg delta circuits and other specialty applications in North America. It provides an unmistakable visual warning that a conductor carries a voltage different from the standard phases - critical information for electricians working with delta transformer configurations. Having a dedicated orange connector in your inventory means phase assignments are physically enforced, minimizing the chance of cross-phase connection errors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does KL-400LMO protect against electrical hazards?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMO incorporates multiple safety features: the non-conductive POM retaining screw prevents accidental current paths through the housing, the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius resists heat and impact, brass contacts minimize resistive heating, and the design meets UL 1691 safety requirements under cUL Listed E332947. The UL Enclosure Types 3R rating also provides protection in wet or outdoor conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs KL-400LMO compatible with other CAM-type connectors?\u003c\/h3\u003e\n    \u003cp\u003eYes. KL-400LMO follows the universal CAM-type single-pole connector standard and intermates with CAM-type connectors from all major manufacturers. This cross-brand compatibility means you can integrate K-LOK connectors into existing power distribution systems without replacing your entire inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat housing material is used in KL-400LMO and why does it matter?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMO uses a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius. Santoprene TPV combines the flexibility of rubber with the processing advantages of thermoplastic, delivering excellent chemical resistance, UV stability, and durability under repeated mechanical stress - exactly what professional power connectors face on tour and on set.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is KL-400LMO and what is it designed for?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMO is a KUPO K-LOK 400A single-pole male inline cable connector with a orange housing, rated for 600V AC\/DC maximum. It is engineered for heavy-duty temporary power distribution in entertainment, industrial, and event production settings. The orange color coding aids rapid phase identification on the job site.\"}}, {\"@type\": \"Question\", \"name\": \"What wire sizes does KL-400LMO accept?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMO accommodates conductors ranging from #6 to 4\/0 AWG. The brass contact assembly ensures reliable electrical performance across this full conductor range, supporting up to 400A at 600V AC\/DC.\"}}, {\"@type\": \"Question\", \"name\": \"Which electrical phase does the orange color represent on KL-400LMO?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Orange is traditionally reserved for high-leg delta circuits and other specialty applications in North America. It provides an unmistakable visual warning that a conductor carries a voltage different from the standard phases - critical information for electricians working with delta transformer configurations. Having a dedicated orange connector in your inventory means phase assignments are physically enforced, minimizing the chance of cross-phase connection errors.\"}}, {\"@type\": \"Question\", \"name\": \"How does KL-400LMO protect against electrical hazards?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMO incorporates multiple safety features: the non-conductive POM retaining screw prevents accidental current paths through the housing, the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius resists heat and impact, brass contacts minimize resistive heating, and the design meets UL 1691 safety requirements under cUL Listed E332947. The UL Enclosure Types 3R rating also provides protection in wet or outdoor conditions.\"}}, {\"@type\": \"Question\", \"name\": \"Is KL-400LMO compatible with other CAM-type connectors?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. KL-400LMO follows the universal CAM-type single-pole connector standard and intermates with CAM-type connectors from all major manufacturers. This cross-brand compatibility means you can integrate K-LOK connectors into existing power distribution systems without replacing your entire inventory.\"}}, {\"@type\": \"Question\", \"name\": \"What housing material is used in KL-400LMO and why does it matter?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMO uses a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius. Santoprene TPV combines the flexibility of rubber with the processing advantages of thermoplastic, delivering excellent chemical resistance, UV stability, and durability under repeated mechanical stress - exactly what professional power connectors face on tour and on set.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400LMO\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/KL-400LMO%20Data%20Sheet.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download KL-400LMO Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Inline Connector","offer_id":50208819806428,"sku":"KL-400LMO","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400LMO.jpg?v=1777362815"},{"product_id":"kl-400lmr","title":"KL-400LMR - K-LOK 400A Male CAM-Type Line Connector, Red","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400LMR --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400LMR\" data-color=\"Red\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Male Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eNon-conductive POM (Polyoxymethylene) retaining screw locks the brass contact firmly in position, eliminating accidental current paths for safer operation\u003c\/li\u003e\n      \u003cli\u003ePOM insulation sleeve adds heat resistance and structural strength to the contact assembly\u003c\/li\u003e\n      \u003cli\u003eRibbed Santoprene TPV housing provides a secure, slip-free grip even when wearing work gloves\u003c\/li\u003e\n      \u003cli\u003eAlignment arrow ensures correct orientation for fast, error-free mating every time\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding site conditions and extreme temperatures\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors with redundant cable retention\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing power infrastructure from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Male In-Line Connector intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400LMR | K-LOK 400A Single-Pole Line Connector, Male, Red, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Male Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400LMR\",\n  \"mpn\": \"KL-400LMR\",\n  \"color\": \"Red\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Male\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Red\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Phase B\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Retaining Screw Material\",\n      \"value\": \"POM (Polyoxymethylene), Non-conductive\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screws\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400LMR\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWho should use KL-400LMR and why?\u003c\/h3\u003e\n    \u003cp\u003eLighting technicians, electricians, and power distribution professionals working with 400A temporary power systems will benefit from KL-400LMR. Its red housing provides instant visual phase identification, while the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius ensures durability in demanding field conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat voltage and amperage is KL-400LMR rated for?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMR carries a maximum rating of 400A and 600V AC\/DC. It accepts wire gauges from #6 to 4\/0 AWG, making it suitable for the conductor sizes typically used in 400-amp power distribution circuits.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhy choose the red version of the K-LOK 400A male line connector?\u003c\/h3\u003e\n    \u003cp\u003eRed marks Phase B (L2) in North American wiring and Phase C (L3) under Chinese GB 50303 standards. It is one of the most visually distinctive colors on a busy job site, helping crews quickly trace the second phase conductor. Choosing KL-400LMR in red ensures your power distribution system follows established color conventions, speeding up setup and reducing wiring errors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs KL-400LMR UL listed and what does that mean?\u003c\/h3\u003e\n    \u003cp\u003eYes. KL-400LMR is cUL Listed under File Number E332947, meaning it has been independently tested and certified to UL 1691 safety standards by a Nationally Recognized Testing Laboratory. This certification is required for professional power distribution in most North American jurisdictions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat industries commonly use KL-400LMR?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMR is widely used in broadcast operations and outside broadcast (OB) van power distribution. Its 400A \/ 600V AC\/DC rating, combined with CAM-type universal compatibility and red phase coding, makes it a versatile choice across the entertainment, construction, and industrial sectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat housing material is used in KL-400LMR and why does it matter?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMR uses a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius. Santoprene TPV combines the flexibility of rubber with the processing advantages of thermoplastic, delivering excellent chemical resistance, UV stability, and durability under repeated mechanical stress - exactly what professional power connectors face on tour and on set.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Who should use KL-400LMR and why?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Lighting technicians, electricians, and power distribution professionals working with 400A temporary power systems will benefit from KL-400LMR. Its red housing provides instant visual phase identification, while the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius ensures durability in demanding field conditions.\"}}, {\"@type\": \"Question\", \"name\": \"What voltage and amperage is KL-400LMR rated for?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMR carries a maximum rating of 400A and 600V AC\/DC. It accepts wire gauges from #6 to 4\/0 AWG, making it suitable for the conductor sizes typically used in 400-amp power distribution circuits.\"}}, {\"@type\": \"Question\", \"name\": \"Why choose the red version of the K-LOK 400A male line connector?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Red marks Phase B (L2) in North American wiring and Phase C (L3) under Chinese GB 50303 standards. It is one of the most visually distinctive colors on a busy job site, helping crews quickly trace the second phase conductor. Choosing KL-400LMR in red ensures your power distribution system follows established color conventions, speeding up setup and reducing wiring errors.\"}}, {\"@type\": \"Question\", \"name\": \"Is KL-400LMR UL listed and what does that mean?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. KL-400LMR is cUL Listed under File Number E332947, meaning it has been independently tested and certified to UL 1691 safety standards by a Nationally Recognized Testing Laboratory. This certification is required for professional power distribution in most North American jurisdictions.\"}}, {\"@type\": \"Question\", \"name\": \"What industries commonly use KL-400LMR?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMR is widely used in broadcast operations and outside broadcast (OB) van power distribution. Its 400A \/ 600V AC\/DC rating, combined with CAM-type universal compatibility and red phase coding, makes it a versatile choice across the entertainment, construction, and industrial sectors.\"}}, {\"@type\": \"Question\", \"name\": \"What housing material is used in KL-400LMR and why does it matter?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMR uses a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius. Santoprene TPV combines the flexibility of rubber with the processing advantages of thermoplastic, delivering excellent chemical resistance, UV stability, and durability under repeated mechanical stress - exactly what professional power connectors face on tour and on set.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400LMR\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/KL-400LMR%20Data%20Sheet.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download KL-400LMR Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Inline Connector","offer_id":50208819839196,"sku":"KL-400LMR","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400LMR.jpg?v=1777362815"},{"product_id":"kl-400lmw","title":"KL-400LMW - K-LOK 400A Male CAM-Type Line Connector, White","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400LMW --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400LMW\" data-color=\"White\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Male Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eNon-conductive POM (Polyoxymethylene) retaining screw locks the brass contact firmly in position, eliminating accidental current paths for safer operation\u003c\/li\u003e\n      \u003cli\u003ePOM insulation sleeve adds heat resistance and structural strength to the contact assembly\u003c\/li\u003e\n      \u003cli\u003eRibbed Santoprene TPV housing provides a secure, slip-free grip even when wearing work gloves\u003c\/li\u003e\n      \u003cli\u003eAlignment arrow ensures correct orientation for fast, error-free mating every time\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding site conditions and extreme temperatures\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors with redundant cable retention\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing power infrastructure from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Male In-Line Connector intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400LMW | K-LOK 400A Single-Pole Line Connector, Male, White, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Male Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400LMW\",\n  \"mpn\": \"KL-400LMW\",\n  \"color\": \"White\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Male\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"White\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Neutral\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Retaining Screw Material\",\n      \"value\": \"POM (Polyoxymethylene), Non-conductive\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screws\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400LMW\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is KL-400LMW and what is it designed for?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMW is a KUPO K-LOK 400A single-pole male inline cable connector with a white housing, rated for 600V AC\/DC maximum. It is engineered for heavy-duty temporary power distribution in entertainment, industrial, and event production settings. The white color coding aids rapid phase identification on the job site.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat wire sizes does KL-400LMW accept?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMW accommodates conductors ranging from #6 to 4\/0 AWG. The brass contact assembly ensures reliable electrical performance across this full conductor range, supporting up to 400A at 600V AC\/DC.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhich electrical phase does the white color represent on KL-400LMW?\u003c\/h3\u003e\n    \u003cp\u003eWhite is universally recognized in North America as the Neutral conductor per NEC conventions. Using a dedicated white connector for neutral runs eliminates guesswork during setup and teardown, reducing the risk of miswired circuits. Having a dedicated white connector in your inventory means phase assignments are physically enforced, minimizing the chance of cross-phase connection errors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does KL-400LMW protect against electrical hazards?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMW incorporates multiple safety features: the non-conductive POM retaining screw prevents accidental current paths through the housing, the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius resists heat and impact, brass contacts minimize resistive heating, and the design meets UL 1691 safety requirements under cUL Listed E332947. The UL Enclosure Types 3R rating also provides protection in wet or outdoor conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs KL-400LMW compatible with other CAM-type connectors?\u003c\/h3\u003e\n    \u003cp\u003eYes. KL-400LMW follows the universal CAM-type single-pole connector standard and intermates with CAM-type connectors from all major manufacturers. This cross-brand compatibility means you can integrate K-LOK connectors into existing power distribution systems without replacing your entire inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is KL-400LMW and what is it designed for?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMW is a KUPO K-LOK 400A single-pole male inline cable connector with a white housing, rated for 600V AC\/DC maximum. It is engineered for heavy-duty temporary power distribution in entertainment, industrial, and event production settings. The white color coding aids rapid phase identification on the job site.\"}}, {\"@type\": \"Question\", \"name\": \"What wire sizes does KL-400LMW accept?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMW accommodates conductors ranging from #6 to 4\/0 AWG. The brass contact assembly ensures reliable electrical performance across this full conductor range, supporting up to 400A at 600V AC\/DC.\"}}, {\"@type\": \"Question\", \"name\": \"Which electrical phase does the white color represent on KL-400LMW?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"White is universally recognized in North America as the Neutral conductor per NEC conventions. Using a dedicated white connector for neutral runs eliminates guesswork during setup and teardown, reducing the risk of miswired circuits. Having a dedicated white connector in your inventory means phase assignments are physically enforced, minimizing the chance of cross-phase connection errors.\"}}, {\"@type\": \"Question\", \"name\": \"How does KL-400LMW protect against electrical hazards?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMW incorporates multiple safety features: the non-conductive POM retaining screw prevents accidental current paths through the housing, the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius resists heat and impact, brass contacts minimize resistive heating, and the design meets UL 1691 safety requirements under cUL Listed E332947. The UL Enclosure Types 3R rating also provides protection in wet or outdoor conditions.\"}}, {\"@type\": \"Question\", \"name\": \"Is KL-400LMW compatible with other CAM-type connectors?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. KL-400LMW follows the universal CAM-type single-pole connector standard and intermates with CAM-type connectors from all major manufacturers. This cross-brand compatibility means you can integrate K-LOK connectors into existing power distribution systems without replacing your entire inventory.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400LMW\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/KL-400LMW%20Data%20Sheet.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download KL-400LMW Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Inline Connector","offer_id":50208819871964,"sku":"KL-400LMW","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400LMW.jpg?v=1777362816"},{"product_id":"kl-400lmy","title":"KL-400LMY - K-LOK 400A Male CAM-Type Line Connector, Yellow","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400LMY --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400LMY\" data-color=\"Yellow\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Male Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eNon-conductive POM (Polyoxymethylene) retaining screw locks the brass contact firmly in position, eliminating accidental current paths for safer operation\u003c\/li\u003e\n      \u003cli\u003ePOM insulation sleeve adds heat resistance and structural strength to the contact assembly\u003c\/li\u003e\n      \u003cli\u003eRibbed Santoprene TPV housing provides a secure, slip-free grip even when wearing work gloves\u003c\/li\u003e\n      \u003cli\u003eAlignment arrow ensures correct orientation for fast, error-free mating every time\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding site conditions and extreme temperatures\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors with redundant cable retention\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing power infrastructure from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Male In-Line Connector intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400LMY | K-LOK 400A Single-Pole Line Connector, Male, Yellow, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Male Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400LMY\",\n  \"mpn\": \"KL-400LMY\",\n  \"color\": \"Yellow\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Male\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Yellow\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Phase A (China GB 50303)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Retaining Screw Material\",\n      \"value\": \"POM (Polyoxymethylene), Non-conductive\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screws\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400LMY\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat kind of connector is KL-400LMY?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMY is a 400-ampere, 600V AC\/DC single-pole male inline cable connector from the KUPO K-LOK series. Finished in yellow, it belongs to the CAM-type connector family widely used across live events, film production, and temporary industrial power systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current can KL-400LMY safely carry?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMY is designed for a maximum continuous load of 400 amperes at up to 600V AC\/DC. The brass contacts and Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius work together to maintain safe operating temperatures even under sustained full-load conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does the yellow color coding on KL-400LMY help on a busy job site?\u003c\/h3\u003e\n    \u003cp\u003eOn a crowded set or event site, identifying conductors quickly is a safety essential. Yellow identifies Phase A (L1) under China's GB 50303 standard and is also used for specialty marking in some North American installations. Its high-visibility color makes it an excellent choice for circuits that need to stand out for safety or identification purposes. The yellow KL-400LMY connector lets technicians trace circuits visually without needing to check labels or test equipment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety certifications does KL-400LMY hold?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LMY is cUL Listed under File Number E332947, certified to UL 1691 - the Standard for Safety for Cam-Type, Locking-Type Separable Connectors. It carries a UL Enclosure Types 3R environment rating, HB \/ UL94 flame classification, and full RoHS (Restriction of Hazardous Substances) compliance.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eCan KL-400LMY work with connectors from other brands?\u003c\/h3\u003e\n    \u003cp\u003eAbsolutely. The K-LOK 400A series uses the industry-standard CAM-type interface, so KL-400LMY mates directly with compatible single-pole connectors regardless of manufacturer. This makes it easy to expand or upgrade your connector stock incrementally.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What kind of connector is KL-400LMY?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMY is a 400-ampere, 600V AC\/DC single-pole male inline cable connector from the KUPO K-LOK series. Finished in yellow, it belongs to the CAM-type connector family widely used across live events, film production, and temporary industrial power systems.\"}}, {\"@type\": \"Question\", \"name\": \"How much current can KL-400LMY safely carry?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMY is designed for a maximum continuous load of 400 amperes at up to 600V AC\/DC. The brass contacts and Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius work together to maintain safe operating temperatures even under sustained full-load conditions.\"}}, {\"@type\": \"Question\", \"name\": \"How does the yellow color coding on KL-400LMY help on a busy job site?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"On a crowded set or event site, identifying conductors quickly is a safety essential. Yellow identifies Phase A (L1) under China's GB 50303 standard and is also used for specialty marking in some North American installations. Its high-visibility color makes it an excellent choice for circuits that need to stand out for safety or identification purposes. The yellow KL-400LMY connector lets technicians trace circuits visually without needing to check labels or test equipment.\"}}, {\"@type\": \"Question\", \"name\": \"What safety certifications does KL-400LMY hold?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LMY is cUL Listed under File Number E332947, certified to UL 1691 - the Standard for Safety for Cam-Type, Locking-Type Separable Connectors. It carries a UL Enclosure Types 3R environment rating, HB \/ UL94 flame classification, and full RoHS (Restriction of Hazardous Substances) compliance.\"}}, {\"@type\": \"Question\", \"name\": \"Can KL-400LMY work with connectors from other brands?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Absolutely. The K-LOK 400A series uses the industry-standard CAM-type interface, so KL-400LMY mates directly with compatible single-pole connectors regardless of manufacturer. This makes it easy to expand or upgrade your connector stock incrementally.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400LMY\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/KL-400LMY%20Data%20Sheet.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download KL-400LMY Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Inline Connector","offer_id":50208819904732,"sku":"KL-400LMY","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400LMY.jpg?v=1777362817"},{"product_id":"kl-400ssfb","title":"KL-400SSFB - K-LOK 400A Female CAM-Type Panel Mount Receptacle, Double Set Screw, Blue","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400SSFB --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400SSFB\" data-color=\"Blue\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Female Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eDouble set screw panel-mount design provides redundant cable retention for maximum security in permanent installations\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding conditions in fixed enclosure installations\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors\u003c\/li\u003e\n      \u003cli\u003eMounting holes enable secure attachment to enclosures, distro boxes, and panel assemblies\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing inline connectors from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Female Panel Mount Receptacle intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400SSFB | K-LOK 400A Single-Pole Panel Mount Receptacle, Female (Double Set Screw Type), Blue, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Female Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400SSFB\",\n  \"mpn\": \"KL-400SSFB\",\n  \"color\": \"Blue\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Mount Receptacle (Double Set Screw)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Female\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Blue\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Phase C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screw (2 x 7\/32\\\" socket head)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400SSFB\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWho should use KL-400SSFB and why?\u003c\/h3\u003e\n    \u003cp\u003eLighting technicians, electricians, and power distribution professionals working with 400A temporary power systems will benefit from KL-400SSFB. Its blue housing provides instant visual phase identification, while the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius ensures durability in demanding field conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat voltage and amperage is KL-400SSFB rated for?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFB carries a maximum rating of 400A and 600V AC\/DC. It accepts wire gauges from #6 to 4\/0 AWG, making it suitable for the conductor sizes typically used in 400-amp power distribution circuits.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhy choose the blue version of the K-LOK 400A female panel mount receptacle?\u003c\/h3\u003e\n    \u003cp\u003eIn North America, blue designates Phase C (L3), completing the three-phase color set. Under IEC 60446, blue is reserved for the Neutral conductor - making this color essential for international projects and cross-border equipment pools. Choosing KL-400SSFB in blue ensures your power distribution system follows established color conventions, speeding up setup and reducing wiring errors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs KL-400SSFB UL listed and what does that mean?\u003c\/h3\u003e\n    \u003cp\u003eYes. KL-400SSFB is cUL Listed under File Number E332947, meaning it has been independently tested and certified to UL 1691 safety standards by a Nationally Recognized Testing Laboratory. This certification is required for professional power distribution in most North American jurisdictions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat industries commonly use KL-400SSFB?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFB is widely used in industrial temporary power connections for manufacturing and processing facilities. Its 400A \/ 600V AC\/DC rating, combined with CAM-type universal compatibility and blue phase coding, makes it a versatile choice across the entertainment, construction, and industrial sectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is KL-400SSFB installed in a power distribution enclosure?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFB uses a double set screw panel-mount design with dedicated mounting holes for secure attachment to enclosures and distro boxes. The double set screw termination provides redundant cable retention - two independent screws clamp the conductor, so even if one loosens under vibration, the connection remains intact.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Who should use KL-400SSFB and why?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Lighting technicians, electricians, and power distribution professionals working with 400A temporary power systems will benefit from KL-400SSFB. Its blue housing provides instant visual phase identification, while the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius ensures durability in demanding field conditions.\"}}, {\"@type\": \"Question\", \"name\": \"What voltage and amperage is KL-400SSFB rated for?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFB carries a maximum rating of 400A and 600V AC\/DC. It accepts wire gauges from #6 to 4\/0 AWG, making it suitable for the conductor sizes typically used in 400-amp power distribution circuits.\"}}, {\"@type\": \"Question\", \"name\": \"Why choose the blue version of the K-LOK 400A female panel mount receptacle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"In North America, blue designates Phase C (L3), completing the three-phase color set. Under IEC 60446, blue is reserved for the Neutral conductor - making this color essential for international projects and cross-border equipment pools. Choosing KL-400SSFB in blue ensures your power distribution system follows established color conventions, speeding up setup and reducing wiring errors.\"}}, {\"@type\": \"Question\", \"name\": \"Is KL-400SSFB UL listed and what does that mean?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. KL-400SSFB is cUL Listed under File Number E332947, meaning it has been independently tested and certified to UL 1691 safety standards by a Nationally Recognized Testing Laboratory. This certification is required for professional power distribution in most North American jurisdictions.\"}}, {\"@type\": \"Question\", \"name\": \"What industries commonly use KL-400SSFB?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFB is widely used in industrial temporary power connections for manufacturing and processing facilities. Its 400A \/ 600V AC\/DC rating, combined with CAM-type universal compatibility and blue phase coding, makes it a versatile choice across the entertainment, construction, and industrial sectors.\"}}, {\"@type\": \"Question\", \"name\": \"How is KL-400SSFB installed in a power distribution enclosure?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFB uses a double set screw panel-mount design with dedicated mounting holes for secure attachment to enclosures and distro boxes. The double set screw termination provides redundant cable retention - two independent screws clamp the conductor, so even if one loosens under vibration, the connection remains intact.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400SSFB\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003c!-- No spec-sheet download link provided in source CSV. --\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Panel Mount Receptacle","offer_id":50208820527324,"sku":"KL-400SSFB","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400SSFB.jpg?v=1777362832"},{"product_id":"kl-400ssfbk","title":"KL-400SSFBK - K-LOK 400A Female CAM-Type Panel Mount Receptacle, Double Set Screw, Black","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400SSFBK --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400SSFBK\" data-color=\"Black\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Female Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eDouble set screw panel-mount design provides redundant cable retention for maximum security in permanent installations\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding conditions in fixed enclosure installations\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors\u003c\/li\u003e\n      \u003cli\u003eMounting holes enable secure attachment to enclosures, distro boxes, and panel assemblies\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing inline connectors from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Female Panel Mount Receptacle intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400SSFBK | K-LOK 400A Single-Pole Panel Mount Receptacle, Female (Double Set Screw Type), Black, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Female Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400SSFBK\",\n  \"mpn\": \"KL-400SSFBK\",\n  \"color\": \"Black\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Mount Receptacle (Double Set Screw)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Female\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Black\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Phase A \/ General\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screw (2 x 7\/32\\\" socket head)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400SSFBK\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is KL-400SSFBK and what is it designed for?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFBK is a KUPO K-LOK 400A single-pole female panel mount receptacle (Double Set Screw Type) with a black housing, rated for 600V AC\/DC maximum. It is engineered for heavy-duty temporary power distribution in entertainment, industrial, and event production settings. The black color coding aids rapid phase identification on the job site.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat wire sizes does KL-400SSFBK accept?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFBK accommodates conductors ranging from #6 to 4\/0 AWG. The brass contact assembly ensures reliable electrical performance across this full conductor range, supporting up to 400A at 600V AC\/DC.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhich electrical phase does the black color represent on KL-400SSFBK?\u003c\/h3\u003e\n    \u003cp\u003eUnder North American NEMA\/NEC conventions, black identifies Phase A (L1), making it the go-to choice for single-phase circuits and the default lead in three-phase systems. In IEC regions, black denotes Phase B (L2). Having a dedicated black connector in your inventory means phase assignments are physically enforced, minimizing the chance of cross-phase connection errors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does KL-400SSFBK protect against electrical hazards?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFBK incorporates multiple safety features: the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius resists heat and impact, brass contacts minimize resistive heating, and the design meets UL 1691 safety requirements under cUL Listed E332947. The UL Enclosure Types 3R rating also provides protection in wet or outdoor conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs KL-400SSFBK compatible with other CAM-type connectors?\u003c\/h3\u003e\n    \u003cp\u003eYes. KL-400SSFBK follows the universal CAM-type single-pole connector standard and intermates with CAM-type connectors from all major manufacturers. This cross-brand compatibility means you can integrate K-LOK connectors into existing power distribution systems without replacing your entire inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the advantage of the double set screw design on KL-400SSFBK?\u003c\/h3\u003e\n    \u003cp\u003eThe double set screw termination on KL-400SSFBK provides redundant cable clamping - each screw independently secures the conductor, adding a layer of safety against vibration-induced loosening. This is particularly valuable in touring rigs and mobile power systems where connectors experience constant mechanical stress.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is KL-400SSFBK and what is it designed for?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFBK is a KUPO K-LOK 400A single-pole female panel mount receptacle (Double Set Screw Type) with a black housing, rated for 600V AC\/DC maximum. It is engineered for heavy-duty temporary power distribution in entertainment, industrial, and event production settings. The black color coding aids rapid phase identification on the job site.\"}}, {\"@type\": \"Question\", \"name\": \"What wire sizes does KL-400SSFBK accept?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFBK accommodates conductors ranging from #6 to 4\/0 AWG. The brass contact assembly ensures reliable electrical performance across this full conductor range, supporting up to 400A at 600V AC\/DC.\"}}, {\"@type\": \"Question\", \"name\": \"Which electrical phase does the black color represent on KL-400SSFBK?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Under North American NEMA\/NEC conventions, black identifies Phase A (L1), making it the go-to choice for single-phase circuits and the default lead in three-phase systems. In IEC regions, black denotes Phase B (L2). Having a dedicated black connector in your inventory means phase assignments are physically enforced, minimizing the chance of cross-phase connection errors.\"}}, {\"@type\": \"Question\", \"name\": \"How does KL-400SSFBK protect against electrical hazards?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFBK incorporates multiple safety features: the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius resists heat and impact, brass contacts minimize resistive heating, and the design meets UL 1691 safety requirements under cUL Listed E332947. The UL Enclosure Types 3R rating also provides protection in wet or outdoor conditions.\"}}, {\"@type\": \"Question\", \"name\": \"Is KL-400SSFBK compatible with other CAM-type connectors?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. KL-400SSFBK follows the universal CAM-type single-pole connector standard and intermates with CAM-type connectors from all major manufacturers. This cross-brand compatibility means you can integrate K-LOK connectors into existing power distribution systems without replacing your entire inventory.\"}}, {\"@type\": \"Question\", \"name\": \"What is the advantage of the double set screw design on KL-400SSFBK?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The double set screw termination on KL-400SSFBK provides redundant cable clamping - each screw independently secures the conductor, adding a layer of safety against vibration-induced loosening. This is particularly valuable in touring rigs and mobile power systems where connectors experience constant mechanical stress.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400SSFBK\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003c!-- No spec-sheet download link provided in source CSV. --\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Panel Mount Receptacle","offer_id":50208820560092,"sku":"KL-400SSFBK","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400SSFBK.jpg?v=1777362833"},{"product_id":"kl-400ssfbn","title":"KL-400SSFBN - K-LOK 400A Female CAM-Type Panel Mount Receptacle, Double Set Screw, Brown","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400SSFBN --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400SSFBN\" data-color=\"Brown\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Female Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eDouble set screw panel-mount design provides redundant cable retention for maximum security in permanent installations\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding conditions in fixed enclosure installations\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors\u003c\/li\u003e\n      \u003cli\u003eMounting holes enable secure attachment to enclosures, distro boxes, and panel assemblies\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing inline connectors from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Female Panel Mount Receptacle intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400SSFBN | K-LOK 400A Single-Pole Panel Mount Receptacle, Female (Double Set Screw Type), Brown, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Female Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400SSFBN\",\n  \"mpn\": \"KL-400SSFBN\",\n  \"color\": \"Brown\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Mount Receptacle (Double Set Screw)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Female\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Brown\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Phase A (IEC)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screw (2 x 7\/32\\\" socket head)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400SSFBN\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat kind of connector is KL-400SSFBN?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFBN is a 400-ampere, 600V AC\/DC single-pole female panel mount receptacle (Double Set Screw Type) from the KUPO K-LOK series. Finished in brown, it belongs to the CAM-type connector family widely used across live events, film production, and temporary industrial power systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current can KL-400SSFBN safely carry?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFBN is designed for a maximum continuous load of 400 amperes at up to 600V AC\/DC. The brass contacts and Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius work together to maintain safe operating temperatures even under sustained full-load conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does the brown color coding on KL-400SSFBN help on a busy job site?\u003c\/h3\u003e\n    \u003cp\u003eOn a crowded set or event site, identifying conductors quickly is a safety essential. Brown designates Phase A (L1) under IEC 60446 conventions used across Europe, the UK, Asia, and Australia. For productions touring internationally or venues hosting global acts, brown connectors ensure IEC-standard phase identification is always available. The brown KL-400SSFBN connector lets technicians trace circuits visually without needing to check labels or test equipment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety certifications does KL-400SSFBN hold?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFBN is cUL Listed under File Number E332947, certified to UL 1691 - the Standard for Safety for Cam-Type, Locking-Type Separable Connectors. It carries a UL Enclosure Types 3R environment rating, HB \/ UL94 flame classification, and full RoHS (Restriction of Hazardous Substances) compliance.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eCan KL-400SSFBN work with connectors from other brands?\u003c\/h3\u003e\n    \u003cp\u003eAbsolutely. The K-LOK 400A series uses the industry-standard CAM-type interface, so KL-400SSFBN mates directly with compatible single-pole connectors regardless of manufacturer. This makes it easy to expand or upgrade your connector stock incrementally.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is KL-400SSFBN installed in a power distribution enclosure?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFBN uses a double set screw panel-mount design with dedicated mounting holes for secure attachment to enclosures and distro boxes. The double set screw termination provides redundant cable retention - two independent screws clamp the conductor, so even if one loosens under vibration, the connection remains intact.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What kind of connector is KL-400SSFBN?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFBN is a 400-ampere, 600V AC\/DC single-pole female panel mount receptacle (Double Set Screw Type) from the KUPO K-LOK series. Finished in brown, it belongs to the CAM-type connector family widely used across live events, film production, and temporary industrial power systems.\"}}, {\"@type\": \"Question\", \"name\": \"How much current can KL-400SSFBN safely carry?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFBN is designed for a maximum continuous load of 400 amperes at up to 600V AC\/DC. The brass contacts and Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius work together to maintain safe operating temperatures even under sustained full-load conditions.\"}}, {\"@type\": \"Question\", \"name\": \"How does the brown color coding on KL-400SSFBN help on a busy job site?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"On a crowded set or event site, identifying conductors quickly is a safety essential. Brown designates Phase A (L1) under IEC 60446 conventions used across Europe, the UK, Asia, and Australia. For productions touring internationally or venues hosting global acts, brown connectors ensure IEC-standard phase identification is always available. The brown KL-400SSFBN connector lets technicians trace circuits visually without needing to check labels or test equipment.\"}}, {\"@type\": \"Question\", \"name\": \"What safety certifications does KL-400SSFBN hold?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFBN is cUL Listed under File Number E332947, certified to UL 1691 - the Standard for Safety for Cam-Type, Locking-Type Separable Connectors. It carries a UL Enclosure Types 3R environment rating, HB \/ UL94 flame classification, and full RoHS (Restriction of Hazardous Substances) compliance.\"}}, {\"@type\": \"Question\", \"name\": \"Can KL-400SSFBN work with connectors from other brands?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Absolutely. The K-LOK 400A series uses the industry-standard CAM-type interface, so KL-400SSFBN mates directly with compatible single-pole connectors regardless of manufacturer. This makes it easy to expand or upgrade your connector stock incrementally.\"}}, {\"@type\": \"Question\", \"name\": \"How is KL-400SSFBN installed in a power distribution enclosure?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFBN uses a double set screw panel-mount design with dedicated mounting holes for secure attachment to enclosures and distro boxes. The double set screw termination provides redundant cable retention - two independent screws clamp the conductor, so even if one loosens under vibration, the connection remains intact.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400SSFBN\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003c!-- No spec-sheet download link provided in source CSV. --\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Panel Mount Receptacle","offer_id":50208820592860,"sku":"KL-400SSFBN","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400SSFBN_b.jpg?v=1777362834"},{"product_id":"kl-400ssfg","title":"KL-400SSFG - K-LOK 400A Female CAM-Type Panel Mount Receptacle, Double Set Screw, Green","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400SSFG --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400SSFG\" data-color=\"Green\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Female Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eDouble set screw panel-mount design provides redundant cable retention for maximum security in permanent installations\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding conditions in fixed enclosure installations\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors\u003c\/li\u003e\n      \u003cli\u003eMounting holes enable secure attachment to enclosures, distro boxes, and panel assemblies\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing inline connectors from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Female Panel Mount Receptacle intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400SSFG | K-LOK 400A Single-Pole Panel Mount Receptacle, Female (Double Set Screw Type), Green, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Female Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400SSFG\",\n  \"mpn\": \"KL-400SSFG\",\n  \"color\": \"Green\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Mount Receptacle (Double Set Screw)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Female\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Green\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Ground \/ Earth\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screw (2 x 7\/32\\\" socket head)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400SSFG\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is KL-400SSFG and what is it designed for?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFG is a KUPO K-LOK 400A single-pole female panel mount receptacle (Double Set Screw Type) with a green housing, rated for 600V AC\/DC maximum. It is engineered for heavy-duty temporary power distribution in entertainment, industrial, and event production settings. The green color coding aids rapid phase identification on the job site.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat wire sizes does KL-400SSFG accept?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFG accommodates conductors ranging from #6 to 4\/0 AWG. The brass contact assembly ensures reliable electrical performance across this full conductor range, supporting up to 400A at 600V AC\/DC.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhich electrical phase does the green color represent on KL-400SSFG?\u003c\/h3\u003e\n    \u003cp\u003eGreen identifies the Ground (Earth \/ PE) conductor across North American and many international standards. Ground integrity is critical for personnel safety, and a distinct green connector ensures the safety earth is never confused with a current-carrying phase. Having a dedicated green connector in your inventory means phase assignments are physically enforced, minimizing the chance of cross-phase connection errors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does KL-400SSFG protect against electrical hazards?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFG incorporates multiple safety features: the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius resists heat and impact, brass contacts minimize resistive heating, and the design meets UL 1691 safety requirements under cUL Listed E332947. The UL Enclosure Types 3R rating also provides protection in wet or outdoor conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs KL-400SSFG compatible with other CAM-type connectors?\u003c\/h3\u003e\n    \u003cp\u003eYes. KL-400SSFG follows the universal CAM-type single-pole connector standard and intermates with CAM-type connectors from all major manufacturers. This cross-brand compatibility means you can integrate K-LOK connectors into existing power distribution systems without replacing your entire inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat housing material is used in KL-400SSFG and why does it matter?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFG uses a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius. Santoprene TPV is chosen for its combination of rubber-like flexibility, heat resistance up to 105 degrees Celsius, and resistance to oils, chemicals, and weathering - ideal for panel mount receptacles that remain permanently installed in demanding environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is KL-400SSFG and what is it designed for?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFG is a KUPO K-LOK 400A single-pole female panel mount receptacle (Double Set Screw Type) with a green housing, rated for 600V AC\/DC maximum. It is engineered for heavy-duty temporary power distribution in entertainment, industrial, and event production settings. The green color coding aids rapid phase identification on the job site.\"}}, {\"@type\": \"Question\", \"name\": \"What wire sizes does KL-400SSFG accept?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFG accommodates conductors ranging from #6 to 4\/0 AWG. The brass contact assembly ensures reliable electrical performance across this full conductor range, supporting up to 400A at 600V AC\/DC.\"}}, {\"@type\": \"Question\", \"name\": \"Which electrical phase does the green color represent on KL-400SSFG?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Green identifies the Ground (Earth \/ PE) conductor across North American and many international standards. Ground integrity is critical for personnel safety, and a distinct green connector ensures the safety earth is never confused with a current-carrying phase. Having a dedicated green connector in your inventory means phase assignments are physically enforced, minimizing the chance of cross-phase connection errors.\"}}, {\"@type\": \"Question\", \"name\": \"How does KL-400SSFG protect against electrical hazards?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFG incorporates multiple safety features: the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius resists heat and impact, brass contacts minimize resistive heating, and the design meets UL 1691 safety requirements under cUL Listed E332947. The UL Enclosure Types 3R rating also provides protection in wet or outdoor conditions.\"}}, {\"@type\": \"Question\", \"name\": \"Is KL-400SSFG compatible with other CAM-type connectors?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. KL-400SSFG follows the universal CAM-type single-pole connector standard and intermates with CAM-type connectors from all major manufacturers. This cross-brand compatibility means you can integrate K-LOK connectors into existing power distribution systems without replacing your entire inventory.\"}}, {\"@type\": \"Question\", \"name\": \"What housing material is used in KL-400SSFG and why does it matter?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFG uses a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius. Santoprene TPV is chosen for its combination of rubber-like flexibility, heat resistance up to 105 degrees Celsius, and resistance to oils, chemicals, and weathering - ideal for panel mount receptacles that remain permanently installed in demanding environments.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400SSFG\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003c!-- No spec-sheet download link provided in source CSV. --\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Panel Mount Receptacle","offer_id":50208820658396,"sku":"KL-400SSFG","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400SSFG_b.jpg?v=1777362835"},{"product_id":"kl-400ssfgy","title":"KL-400SSFGY - K-LOK 400A Female CAM-Type Panel Mount Receptacle, Double Set Screw, Grey","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400SSFGY --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400SSFGY\" data-color=\"Grey\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Female Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eDouble set screw panel-mount design provides redundant cable retention for maximum security in permanent installations\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding conditions in fixed enclosure installations\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors\u003c\/li\u003e\n      \u003cli\u003eMounting holes enable secure attachment to enclosures, distro boxes, and panel assemblies\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing inline connectors from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Female Panel Mount Receptacle intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400SSFGY | K-LOK 400A Single-Pole Panel Mount Receptacle, Female (Double Set Screw Type), Grey, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Female Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400SSFGY\",\n  \"mpn\": \"KL-400SSFGY\",\n  \"color\": \"Grey\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Mount Receptacle (Double Set Screw)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Female\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Grey\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Neutral (IEC)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screw (2 x 7\/32\\\" socket head)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400SSFGY\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWho should use KL-400SSFGY and why?\u003c\/h3\u003e\n    \u003cp\u003eLighting technicians, electricians, and power distribution professionals working with 400A temporary power systems will benefit from KL-400SSFGY. Its grey housing provides instant visual phase identification, while the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius ensures durability in demanding field conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat voltage and amperage is KL-400SSFGY rated for?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFGY carries a maximum rating of 400A and 600V AC\/DC. It accepts wire gauges from #6 to 4\/0 AWG, making it suitable for the conductor sizes typically used in 400-amp power distribution circuits.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhy choose the grey version of the K-LOK 400A female panel mount receptacle?\u003c\/h3\u003e\n    \u003cp\u003eGrey represents Phase C (L3) - and in some IEC applications, Neutral - under the international color code. Adding grey to the connector inventory ensures full IEC three-phase coverage alongside brown and black. Choosing KL-400SSFGY in grey ensures your power distribution system follows established color conventions, speeding up setup and reducing wiring errors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs KL-400SSFGY UL listed and what does that mean?\u003c\/h3\u003e\n    \u003cp\u003eYes. KL-400SSFGY is cUL Listed under File Number E332947, meaning it has been independently tested and certified to UL 1691 safety standards by a Nationally Recognized Testing Laboratory. This certification is required for professional power distribution in most North American jurisdictions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat industries commonly use KL-400SSFGY?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFGY is widely used in rental house and staging company inventories serving diverse entertainment clients. Its 400A \/ 600V AC\/DC rating, combined with CAM-type universal compatibility and grey phase coding, makes it a versatile choice across the entertainment, construction, and industrial sectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Who should use KL-400SSFGY and why?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Lighting technicians, electricians, and power distribution professionals working with 400A temporary power systems will benefit from KL-400SSFGY. Its grey housing provides instant visual phase identification, while the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius ensures durability in demanding field conditions.\"}}, {\"@type\": \"Question\", \"name\": \"What voltage and amperage is KL-400SSFGY rated for?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFGY carries a maximum rating of 400A and 600V AC\/DC. It accepts wire gauges from #6 to 4\/0 AWG, making it suitable for the conductor sizes typically used in 400-amp power distribution circuits.\"}}, {\"@type\": \"Question\", \"name\": \"Why choose the grey version of the K-LOK 400A female panel mount receptacle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Grey represents Phase C (L3) - and in some IEC applications, Neutral - under the international color code. Adding grey to the connector inventory ensures full IEC three-phase coverage alongside brown and black. Choosing KL-400SSFGY in grey ensures your power distribution system follows established color conventions, speeding up setup and reducing wiring errors.\"}}, {\"@type\": \"Question\", \"name\": \"Is KL-400SSFGY UL listed and what does that mean?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. KL-400SSFGY is cUL Listed under File Number E332947, meaning it has been independently tested and certified to UL 1691 safety standards by a Nationally Recognized Testing Laboratory. This certification is required for professional power distribution in most North American jurisdictions.\"}}, {\"@type\": \"Question\", \"name\": \"What industries commonly use KL-400SSFGY?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFGY is widely used in rental house and staging company inventories serving diverse entertainment clients. Its 400A \/ 600V AC\/DC rating, combined with CAM-type universal compatibility and grey phase coding, makes it a versatile choice across the entertainment, construction, and industrial sectors.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400SSFGY\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003c!-- No spec-sheet download link provided in source CSV. --\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Panel Mount Receptacle","offer_id":50208820691164,"sku":"KL-400SSFGY","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400SSFGY_b.jpg?v=1777362835"},{"product_id":"kl-400ssfo","title":"KL-400SSFO - K-LOK 400A Female CAM-Type Panel Mount Receptacle, Double Set Screw, Orange","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400SSFO --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400SSFO\" data-color=\"Orange\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Female Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eDouble set screw panel-mount design provides redundant cable retention for maximum security in permanent installations\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding conditions in fixed enclosure installations\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors\u003c\/li\u003e\n      \u003cli\u003eMounting holes enable secure attachment to enclosures, distro boxes, and panel assemblies\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing inline connectors from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Female Panel Mount Receptacle intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400SSFO | K-LOK 400A Single-Pole Panel Mount Receptacle, Female (Double Set Screw Type), Orange, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Female Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400SSFO\",\n  \"mpn\": \"KL-400SSFO\",\n  \"color\": \"Orange\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Mount Receptacle (Double Set Screw)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Female\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Orange\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"High-Leg Delta \/ Special Identification\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screw (2 x 7\/32\\\" socket head)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400SSFO\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does KL-400SSFO do and where is it typically used?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFO provides a safe, reliable single-pole female connection point for 400A circuits at up to 600V AC\/DC. As a panel mount receptacle with orange color coding, it is commonly used in professional entertainment power distribution, temporary construction feeds, and industrial installations.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat are the electrical ratings of KL-400SSFO?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFO is rated for 400 amperes maximum continuous current at 600V AC\/DC maximum. It accepts conductors from #6 to 4\/0 AWG (American Wire Gauge), with brass contacts delivering low-resistance connections for sustained high-current loads.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the orange housing on KL-400SSFO signify?\u003c\/h3\u003e\n    \u003cp\u003eOrange is traditionally reserved for high-leg delta circuits and other specialty applications in North America. It provides an unmistakable visual warning that a conductor carries a voltage different from the standard phases - critical information for electricians working with delta transformer configurations. Color-coded connectors like KL-400SSFO allow crews to visually verify correct phase wiring at a glance, which is especially valuable during fast-paced load-ins and load-outs.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety standards apply to KL-400SSFO?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFO meets UL 1691 (Cam-Type, Locking-Type Separable Connectors), is cUL Listed under E332947, rated UL Enclosure Types 3R for weather resistance, carries a HB \/ UL94 flame class, and complies with RoHS hazardous substance restrictions. These certifications collectively ensure the connector is safe for professional use in entertainment and industrial environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhere is KL-400SSFO commonly deployed?\u003c\/h3\u003e\n    \u003cp\u003eYou will find KL-400SSFO at work in portable power distribution for emergency and disaster-response operations. The orange color coding and 400-amp capacity make it particularly well suited for multi-phase power distribution in professional settings.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat housing material is used in KL-400SSFO and why does it matter?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFO uses a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius. Santoprene TPV is chosen for its combination of rubber-like flexibility, heat resistance up to 105 degrees Celsius, and resistance to oils, chemicals, and weathering - ideal for panel mount receptacles that remain permanently installed in demanding environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What does KL-400SSFO do and where is it typically used?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFO provides a safe, reliable single-pole female connection point for 400A circuits at up to 600V AC\/DC. As a panel mount receptacle with orange color coding, it is commonly used in professional entertainment power distribution, temporary construction feeds, and industrial installations.\"}}, {\"@type\": \"Question\", \"name\": \"What are the electrical ratings of KL-400SSFO?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFO is rated for 400 amperes maximum continuous current at 600V AC\/DC maximum. It accepts conductors from #6 to 4\/0 AWG (American Wire Gauge), with brass contacts delivering low-resistance connections for sustained high-current loads.\"}}, {\"@type\": \"Question\", \"name\": \"What does the orange housing on KL-400SSFO signify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Orange is traditionally reserved for high-leg delta circuits and other specialty applications in North America. It provides an unmistakable visual warning that a conductor carries a voltage different from the standard phases - critical information for electricians working with delta transformer configurations. Color-coded connectors like KL-400SSFO allow crews to visually verify correct phase wiring at a glance, which is especially valuable during fast-paced load-ins and load-outs.\"}}, {\"@type\": \"Question\", \"name\": \"What safety standards apply to KL-400SSFO?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFO meets UL 1691 (Cam-Type, Locking-Type Separable Connectors), is cUL Listed under E332947, rated UL Enclosure Types 3R for weather resistance, carries a HB \/ UL94 flame class, and complies with RoHS hazardous substance restrictions. These certifications collectively ensure the connector is safe for professional use in entertainment and industrial environments.\"}}, {\"@type\": \"Question\", \"name\": \"Where is KL-400SSFO commonly deployed?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"You will find KL-400SSFO at work in portable power distribution for emergency and disaster-response operations. The orange color coding and 400-amp capacity make it particularly well suited for multi-phase power distribution in professional settings.\"}}, {\"@type\": \"Question\", \"name\": \"What housing material is used in KL-400SSFO and why does it matter?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFO uses a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius. Santoprene TPV is chosen for its combination of rubber-like flexibility, heat resistance up to 105 degrees Celsius, and resistance to oils, chemicals, and weathering - ideal for panel mount receptacles that remain permanently installed in demanding environments.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400SSFO\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003c!-- No spec-sheet download link provided in source CSV. --\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Panel Mount Receptacle","offer_id":50208820723932,"sku":"KL-400SSFO","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400SSFO_b.jpg?v=1777362836"},{"product_id":"kl-400ssfr","title":"KL-400SSFR - K-LOK 400A Female CAM-Type Panel Mount Receptacle, Double Set Screw, Red","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400SSFR --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400SSFR\" data-color=\"Red\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Female Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eDouble set screw panel-mount design provides redundant cable retention for maximum security in permanent installations\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding conditions in fixed enclosure installations\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors\u003c\/li\u003e\n      \u003cli\u003eMounting holes enable secure attachment to enclosures, distro boxes, and panel assemblies\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing inline connectors from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Female Panel Mount Receptacle intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400SSFR | K-LOK 400A Single-Pole Panel Mount Receptacle, Female (Double Set Screw Type), Red, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Female Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400SSFR\",\n  \"mpn\": \"KL-400SSFR\",\n  \"color\": \"Red\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Mount Receptacle (Double Set Screw)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Female\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Red\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Phase B\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screw (2 x 7\/32\\\" socket head)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400SSFR\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat kind of connector is KL-400SSFR?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFR is a 400-ampere, 600V AC\/DC single-pole female panel mount receptacle (Double Set Screw Type) from the KUPO K-LOK series. Finished in red, it belongs to the CAM-type connector family widely used across live events, film production, and temporary industrial power systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current can KL-400SSFR safely carry?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFR is designed for a maximum continuous load of 400 amperes at up to 600V AC\/DC. The brass contacts and Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius work together to maintain safe operating temperatures even under sustained full-load conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does the red color coding on KL-400SSFR help on a busy job site?\u003c\/h3\u003e\n    \u003cp\u003eOn a crowded set or event site, identifying conductors quickly is a safety essential. Red marks Phase B (L2) in North American wiring and Phase C (L3) under Chinese GB 50303 standards. It is one of the most visually distinctive colors on a busy job site, helping crews quickly trace the second phase conductor. The red KL-400SSFR connector lets technicians trace circuits visually without needing to check labels or test equipment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety certifications does KL-400SSFR hold?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFR is cUL Listed under File Number E332947, certified to UL 1691 - the Standard for Safety for Cam-Type, Locking-Type Separable Connectors. It carries a UL Enclosure Types 3R environment rating, HB \/ UL94 flame classification, and full RoHS (Restriction of Hazardous Substances) compliance.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eCan KL-400SSFR work with connectors from other brands?\u003c\/h3\u003e\n    \u003cp\u003eAbsolutely. The K-LOK 400A series uses the industry-standard CAM-type interface, so KL-400SSFR mates directly with compatible single-pole connectors regardless of manufacturer. This makes it easy to expand or upgrade your connector stock incrementally.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What kind of connector is KL-400SSFR?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFR is a 400-ampere, 600V AC\/DC single-pole female panel mount receptacle (Double Set Screw Type) from the KUPO K-LOK series. Finished in red, it belongs to the CAM-type connector family widely used across live events, film production, and temporary industrial power systems.\"}}, {\"@type\": \"Question\", \"name\": \"How much current can KL-400SSFR safely carry?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFR is designed for a maximum continuous load of 400 amperes at up to 600V AC\/DC. The brass contacts and Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius work together to maintain safe operating temperatures even under sustained full-load conditions.\"}}, {\"@type\": \"Question\", \"name\": \"How does the red color coding on KL-400SSFR help on a busy job site?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"On a crowded set or event site, identifying conductors quickly is a safety essential. Red marks Phase B (L2) in North American wiring and Phase C (L3) under Chinese GB 50303 standards. It is one of the most visually distinctive colors on a busy job site, helping crews quickly trace the second phase conductor. The red KL-400SSFR connector lets technicians trace circuits visually without needing to check labels or test equipment.\"}}, {\"@type\": \"Question\", \"name\": \"What safety certifications does KL-400SSFR hold?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFR is cUL Listed under File Number E332947, certified to UL 1691 - the Standard for Safety for Cam-Type, Locking-Type Separable Connectors. It carries a UL Enclosure Types 3R environment rating, HB \/ UL94 flame classification, and full RoHS (Restriction of Hazardous Substances) compliance.\"}}, {\"@type\": \"Question\", \"name\": \"Can KL-400SSFR work with connectors from other brands?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Absolutely. The K-LOK 400A series uses the industry-standard CAM-type interface, so KL-400SSFR mates directly with compatible single-pole connectors regardless of manufacturer. This makes it easy to expand or upgrade your connector stock incrementally.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400SSFR\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003c!-- No spec-sheet download link provided in source CSV. --\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Panel Mount Receptacle","offer_id":50208820756700,"sku":"KL-400SSFR","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400SSFR_b.jpg?v=1777362837"},{"product_id":"kl-400ssfw","title":"KL-400SSFW - K-LOK 400A Female CAM-Type Panel Mount Receptacle, Double Set Screw, White","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400SSFW --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400SSFW\" data-color=\"White\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Female Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eDouble set screw panel-mount design provides redundant cable retention for maximum security in permanent installations\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding conditions in fixed enclosure installations\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors\u003c\/li\u003e\n      \u003cli\u003eMounting holes enable secure attachment to enclosures, distro boxes, and panel assemblies\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing inline connectors from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Female Panel Mount Receptacle intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400SSFW | K-LOK 400A Single-Pole Panel Mount Receptacle, Female (Double Set Screw Type), White, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Female Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400SSFW\",\n  \"mpn\": \"KL-400SSFW\",\n  \"color\": \"White\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Mount Receptacle (Double Set Screw)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Female\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"White\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Neutral\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screw (2 x 7\/32\\\" socket head)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400SSFW\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does KL-400SSFW do and where is it typically used?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFW provides a safe, reliable single-pole female connection point for 400A circuits at up to 600V AC\/DC. As a panel mount receptacle with white color coding, it is commonly used in professional entertainment power distribution, temporary construction feeds, and industrial installations.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat are the electrical ratings of KL-400SSFW?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFW is rated for 400 amperes maximum continuous current at 600V AC\/DC maximum. It accepts conductors from #6 to 4\/0 AWG (American Wire Gauge), with brass contacts delivering low-resistance connections for sustained high-current loads.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the white housing on KL-400SSFW signify?\u003c\/h3\u003e\n    \u003cp\u003eWhite is universally recognized in North America as the Neutral conductor per NEC conventions. Using a dedicated white connector for neutral runs eliminates guesswork during setup and teardown, reducing the risk of miswired circuits. Color-coded connectors like KL-400SSFW allow crews to visually verify correct phase wiring at a glance, which is especially valuable during fast-paced load-ins and load-outs.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety standards apply to KL-400SSFW?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFW meets UL 1691 (Cam-Type, Locking-Type Separable Connectors), is cUL Listed under E332947, rated UL Enclosure Types 3R for weather resistance, carries a HB \/ UL94 flame class, and complies with RoHS hazardous substance restrictions. These certifications collectively ensure the connector is safe for professional use in entertainment and industrial environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhere is KL-400SSFW commonly deployed?\u003c\/h3\u003e\n    \u003cp\u003eYou will find KL-400SSFW at work in studio power distribution in recording, post-production, and live broadcast environments. The white color coding and 400-amp capacity make it particularly well suited for multi-phase power distribution in professional settings.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the advantage of the double set screw design on KL-400SSFW?\u003c\/h3\u003e\n    \u003cp\u003eThe double set screw termination on KL-400SSFW provides redundant cable clamping - each screw independently secures the conductor, adding a layer of safety against vibration-induced loosening. This is particularly valuable in touring rigs and mobile power systems where connectors experience constant mechanical stress.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What does KL-400SSFW do and where is it typically used?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFW provides a safe, reliable single-pole female connection point for 400A circuits at up to 600V AC\/DC. As a panel mount receptacle with white color coding, it is commonly used in professional entertainment power distribution, temporary construction feeds, and industrial installations.\"}}, {\"@type\": \"Question\", \"name\": \"What are the electrical ratings of KL-400SSFW?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFW is rated for 400 amperes maximum continuous current at 600V AC\/DC maximum. It accepts conductors from #6 to 4\/0 AWG (American Wire Gauge), with brass contacts delivering low-resistance connections for sustained high-current loads.\"}}, {\"@type\": \"Question\", \"name\": \"What does the white housing on KL-400SSFW signify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"White is universally recognized in North America as the Neutral conductor per NEC conventions. Using a dedicated white connector for neutral runs eliminates guesswork during setup and teardown, reducing the risk of miswired circuits. Color-coded connectors like KL-400SSFW allow crews to visually verify correct phase wiring at a glance, which is especially valuable during fast-paced load-ins and load-outs.\"}}, {\"@type\": \"Question\", \"name\": \"What safety standards apply to KL-400SSFW?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFW meets UL 1691 (Cam-Type, Locking-Type Separable Connectors), is cUL Listed under E332947, rated UL Enclosure Types 3R for weather resistance, carries a HB \/ UL94 flame class, and complies with RoHS hazardous substance restrictions. These certifications collectively ensure the connector is safe for professional use in entertainment and industrial environments.\"}}, {\"@type\": \"Question\", \"name\": \"Where is KL-400SSFW commonly deployed?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"You will find KL-400SSFW at work in studio power distribution in recording, post-production, and live broadcast environments. The white color coding and 400-amp capacity make it particularly well suited for multi-phase power distribution in professional settings.\"}}, {\"@type\": \"Question\", \"name\": \"What is the advantage of the double set screw design on KL-400SSFW?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The double set screw termination on KL-400SSFW provides redundant cable clamping - each screw independently secures the conductor, adding a layer of safety against vibration-induced loosening. This is particularly valuable in touring rigs and mobile power systems where connectors experience constant mechanical stress.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400SSFW\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003c!-- No spec-sheet download link provided in source CSV. --\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Panel Mount Receptacle","offer_id":50208820789468,"sku":"KL-400SSFW","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400SSFW.jpg?v=1777362838"},{"product_id":"kl-400ssfy","title":"KL-400SSFY - K-LOK 400A Female CAM-Type Panel Mount Receptacle, Double Set Screw, Yellow","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400SSFY --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400SSFY\" data-color=\"Yellow\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Female Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eDouble set screw panel-mount design provides redundant cable retention for maximum security in permanent installations\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding conditions in fixed enclosure installations\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors\u003c\/li\u003e\n      \u003cli\u003eMounting holes enable secure attachment to enclosures, distro boxes, and panel assemblies\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing inline connectors from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Female Panel Mount Receptacle intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400SSFY | K-LOK 400A Single-Pole Panel Mount Receptacle, Female (Double Set Screw Type), Yellow, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Female Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400SSFY\",\n  \"mpn\": \"KL-400SSFY\",\n  \"color\": \"Yellow\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Mount Receptacle (Double Set Screw)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Female\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Yellow\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Phase A (China GB 50303)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screw (2 x 7\/32\\\" socket head)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400SSFY\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is KL-400SSFY and what is it designed for?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFY is a KUPO K-LOK 400A single-pole female panel mount receptacle (Double Set Screw Type) with a yellow housing, rated for 600V AC\/DC maximum. It is engineered for heavy-duty temporary power distribution in entertainment, industrial, and event production settings. The yellow color coding aids rapid phase identification on the job site.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat wire sizes does KL-400SSFY accept?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFY accommodates conductors ranging from #6 to 4\/0 AWG. The brass contact assembly ensures reliable electrical performance across this full conductor range, supporting up to 400A at 600V AC\/DC.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhich electrical phase does the yellow color represent on KL-400SSFY?\u003c\/h3\u003e\n    \u003cp\u003eYellow identifies Phase A (L1) under China's GB 50303 standard and is also used for specialty marking in some North American installations. Its high-visibility color makes it an excellent choice for circuits that need to stand out for safety or identification purposes. Having a dedicated yellow connector in your inventory means phase assignments are physically enforced, minimizing the chance of cross-phase connection errors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does KL-400SSFY protect against electrical hazards?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFY incorporates multiple safety features: the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius resists heat and impact, brass contacts minimize resistive heating, and the design meets UL 1691 safety requirements under cUL Listed E332947. The UL Enclosure Types 3R rating also provides protection in wet or outdoor conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs KL-400SSFY compatible with other CAM-type connectors?\u003c\/h3\u003e\n    \u003cp\u003eYes. KL-400SSFY follows the universal CAM-type single-pole connector standard and intermates with CAM-type connectors from all major manufacturers. This cross-brand compatibility means you can integrate K-LOK connectors into existing power distribution systems without replacing your entire inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is KL-400SSFY installed in a power distribution enclosure?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFY uses a double set screw panel-mount design with dedicated mounting holes for secure attachment to enclosures and distro boxes. The double set screw termination provides redundant cable retention - two independent screws clamp the conductor, so even if one loosens under vibration, the connection remains intact.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is KL-400SSFY and what is it designed for?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFY is a KUPO K-LOK 400A single-pole female panel mount receptacle (Double Set Screw Type) with a yellow housing, rated for 600V AC\/DC maximum. It is engineered for heavy-duty temporary power distribution in entertainment, industrial, and event production settings. The yellow color coding aids rapid phase identification on the job site.\"}}, {\"@type\": \"Question\", \"name\": \"What wire sizes does KL-400SSFY accept?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFY accommodates conductors ranging from #6 to 4\/0 AWG. The brass contact assembly ensures reliable electrical performance across this full conductor range, supporting up to 400A at 600V AC\/DC.\"}}, {\"@type\": \"Question\", \"name\": \"Which electrical phase does the yellow color represent on KL-400SSFY?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yellow identifies Phase A (L1) under China's GB 50303 standard and is also used for specialty marking in some North American installations. Its high-visibility color makes it an excellent choice for circuits that need to stand out for safety or identification purposes. Having a dedicated yellow connector in your inventory means phase assignments are physically enforced, minimizing the chance of cross-phase connection errors.\"}}, {\"@type\": \"Question\", \"name\": \"How does KL-400SSFY protect against electrical hazards?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFY incorporates multiple safety features: the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius resists heat and impact, brass contacts minimize resistive heating, and the design meets UL 1691 safety requirements under cUL Listed E332947. The UL Enclosure Types 3R rating also provides protection in wet or outdoor conditions.\"}}, {\"@type\": \"Question\", \"name\": \"Is KL-400SSFY compatible with other CAM-type connectors?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. KL-400SSFY follows the universal CAM-type single-pole connector standard and intermates with CAM-type connectors from all major manufacturers. This cross-brand compatibility means you can integrate K-LOK connectors into existing power distribution systems without replacing your entire inventory.\"}}, {\"@type\": \"Question\", \"name\": \"How is KL-400SSFY installed in a power distribution enclosure?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFY uses a double set screw panel-mount design with dedicated mounting holes for secure attachment to enclosures and distro boxes. The double set screw termination provides redundant cable retention - two independent screws clamp the conductor, so even if one loosens under vibration, the connection remains intact.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400SSFY\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003c!-- No spec-sheet download link provided in source CSV. --\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Panel Mount Receptacle","offer_id":50208820822236,"sku":"KL-400SSFY","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400SSFY_b.jpg?v=1777362839"},{"product_id":"kl-400ssmb","title":"KL-400SSMB - K-LOK 400A Male CAM-Type Panel Mount Receptacle, Double Set Screw, Blue","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400SSMB --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400SSMB\" data-color=\"Blue\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Male Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eDouble set screw panel-mount design provides redundant cable retention for maximum security in permanent installations\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding conditions in fixed enclosure installations\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors\u003c\/li\u003e\n      \u003cli\u003eMounting holes enable secure attachment to enclosures, distro boxes, and panel assemblies\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing inline connectors from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Male Panel Mount Receptacle intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400SSMB | K-LOK 400A Single-Pole Panel Mount Receptacle, Male (Double Set Screw Type), Blue, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Male Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400SSMB\",\n  \"mpn\": \"KL-400SSMB\",\n  \"color\": \"Blue\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Mount Receptacle (Double Set Screw)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Male\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Blue\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Phase C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screw (2 x 7\/32\\\" socket head)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400SSMB\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does KL-400SSMB do and where is it typically used?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMB provides a safe, reliable single-pole male connection point for 400A circuits at up to 600V AC\/DC. As a panel mount receptacle with blue color coding, it is commonly used in professional entertainment power distribution, temporary construction feeds, and industrial installations.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat are the electrical ratings of KL-400SSMB?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMB is rated for 400 amperes maximum continuous current at 600V AC\/DC maximum. It accepts conductors from #6 to 4\/0 AWG (American Wire Gauge), with brass contacts delivering low-resistance connections for sustained high-current loads.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the blue housing on KL-400SSMB signify?\u003c\/h3\u003e\n    \u003cp\u003eIn North America, blue designates Phase C (L3), completing the three-phase color set. Under IEC 60446, blue is reserved for the Neutral conductor - making this color essential for international projects and cross-border equipment pools. Color-coded connectors like KL-400SSMB allow crews to visually verify correct phase wiring at a glance, which is especially valuable during fast-paced load-ins and load-outs.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety standards apply to KL-400SSMB?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMB meets UL 1691 (Cam-Type, Locking-Type Separable Connectors), is cUL Listed under E332947, rated UL Enclosure Types 3R for weather resistance, carries a HB \/ UL94 flame class, and complies with RoHS hazardous substance restrictions. These certifications collectively ensure the connector is safe for professional use in entertainment and industrial environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhere is KL-400SSMB commonly deployed?\u003c\/h3\u003e\n    \u003cp\u003eYou will find KL-400SSMB at work in trade shows and exhibition installations that demand professional-grade temporary power. The blue color coding and 400-amp capacity make it particularly well suited for multi-phase power distribution in professional settings.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What does KL-400SSMB do and where is it typically used?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMB provides a safe, reliable single-pole male connection point for 400A circuits at up to 600V AC\/DC. As a panel mount receptacle with blue color coding, it is commonly used in professional entertainment power distribution, temporary construction feeds, and industrial installations.\"}}, {\"@type\": \"Question\", \"name\": \"What are the electrical ratings of KL-400SSMB?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMB is rated for 400 amperes maximum continuous current at 600V AC\/DC maximum. It accepts conductors from #6 to 4\/0 AWG (American Wire Gauge), with brass contacts delivering low-resistance connections for sustained high-current loads.\"}}, {\"@type\": \"Question\", \"name\": \"What does the blue housing on KL-400SSMB signify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"In North America, blue designates Phase C (L3), completing the three-phase color set. Under IEC 60446, blue is reserved for the Neutral conductor - making this color essential for international projects and cross-border equipment pools. Color-coded connectors like KL-400SSMB allow crews to visually verify correct phase wiring at a glance, which is especially valuable during fast-paced load-ins and load-outs.\"}}, {\"@type\": \"Question\", \"name\": \"What safety standards apply to KL-400SSMB?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMB meets UL 1691 (Cam-Type, Locking-Type Separable Connectors), is cUL Listed under E332947, rated UL Enclosure Types 3R for weather resistance, carries a HB \/ UL94 flame class, and complies with RoHS hazardous substance restrictions. These certifications collectively ensure the connector is safe for professional use in entertainment and industrial environments.\"}}, {\"@type\": \"Question\", \"name\": \"Where is KL-400SSMB commonly deployed?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"You will find KL-400SSMB at work in trade shows and exhibition installations that demand professional-grade temporary power. The blue color coding and 400-amp capacity make it particularly well suited for multi-phase power distribution in professional settings.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400SSMB\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003c!-- No spec-sheet download link provided in source CSV. --\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Panel Mount Receptacle","offer_id":50208820855004,"sku":"KL-400SSMB","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400SSMB.jpg?v=1777362840"},{"product_id":"kl-400ssmbk","title":"KL-400SSMBK - K-LOK 400A Male CAM-Type Panel Mount Receptacle, Double Set Screw, Black","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400SSMBK --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400SSMBK\" data-color=\"Black\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Male Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eDouble set screw panel-mount design provides redundant cable retention for maximum security in permanent installations\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding conditions in fixed enclosure installations\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors\u003c\/li\u003e\n      \u003cli\u003eMounting holes enable secure attachment to enclosures, distro boxes, and panel assemblies\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing inline connectors from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Male Panel Mount Receptacle intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400SSMBK | K-LOK 400A Single-Pole Panel Mount Receptacle, Male (Double Set Screw Type), Black, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Male Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400SSMBK\",\n  \"mpn\": \"KL-400SSMBK\",\n  \"color\": \"Black\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Mount Receptacle (Double Set Screw)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Male\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Black\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Phase A \/ General\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screw (2 x 7\/32\\\" socket head)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400SSMBK\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat kind of connector is KL-400SSMBK?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMBK is a 400-ampere, 600V AC\/DC single-pole male panel mount receptacle (Double Set Screw Type) from the KUPO K-LOK series. Finished in black, it belongs to the CAM-type connector family widely used across live events, film production, and temporary industrial power systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current can KL-400SSMBK safely carry?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMBK is designed for a maximum continuous load of 400 amperes at up to 600V AC\/DC. The brass contacts and Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius work together to maintain safe operating temperatures even under sustained full-load conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does the black color coding on KL-400SSMBK help on a busy job site?\u003c\/h3\u003e\n    \u003cp\u003eOn a crowded set or event site, identifying conductors quickly is a safety essential. Under North American NEMA\/NEC conventions, black identifies Phase A (L1), making it the go-to choice for single-phase circuits and the default lead in three-phase systems. In IEC regions, black denotes Phase B (L2). The black KL-400SSMBK connector lets technicians trace circuits visually without needing to check labels or test equipment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety certifications does KL-400SSMBK hold?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMBK is cUL Listed under File Number E332947, certified to UL 1691 - the Standard for Safety for Cam-Type, Locking-Type Separable Connectors. It carries a UL Enclosure Types 3R environment rating, HB \/ UL94 flame classification, and full RoHS (Restriction of Hazardous Substances) compliance.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eCan KL-400SSMBK work with connectors from other brands?\u003c\/h3\u003e\n    \u003cp\u003eAbsolutely. The K-LOK 400A series uses the industry-standard CAM-type interface, so KL-400SSMBK mates directly with compatible single-pole connectors regardless of manufacturer. This makes it easy to expand or upgrade your connector stock incrementally.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the advantage of the double set screw design on KL-400SSMBK?\u003c\/h3\u003e\n    \u003cp\u003eThe double set screw termination on KL-400SSMBK provides redundant cable clamping - each screw independently secures the conductor, adding a layer of safety against vibration-induced loosening. This is particularly valuable in touring rigs and mobile power systems where connectors experience constant mechanical stress.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What kind of connector is KL-400SSMBK?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMBK is a 400-ampere, 600V AC\/DC single-pole male panel mount receptacle (Double Set Screw Type) from the KUPO K-LOK series. Finished in black, it belongs to the CAM-type connector family widely used across live events, film production, and temporary industrial power systems.\"}}, {\"@type\": \"Question\", \"name\": \"How much current can KL-400SSMBK safely carry?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMBK is designed for a maximum continuous load of 400 amperes at up to 600V AC\/DC. The brass contacts and Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius work together to maintain safe operating temperatures even under sustained full-load conditions.\"}}, {\"@type\": \"Question\", \"name\": \"How does the black color coding on KL-400SSMBK help on a busy job site?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"On a crowded set or event site, identifying conductors quickly is a safety essential. Under North American NEMA\/NEC conventions, black identifies Phase A (L1), making it the go-to choice for single-phase circuits and the default lead in three-phase systems. In IEC regions, black denotes Phase B (L2). The black KL-400SSMBK connector lets technicians trace circuits visually without needing to check labels or test equipment.\"}}, {\"@type\": \"Question\", \"name\": \"What safety certifications does KL-400SSMBK hold?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMBK is cUL Listed under File Number E332947, certified to UL 1691 - the Standard for Safety for Cam-Type, Locking-Type Separable Connectors. It carries a UL Enclosure Types 3R environment rating, HB \/ UL94 flame classification, and full RoHS (Restriction of Hazardous Substances) compliance.\"}}, {\"@type\": \"Question\", \"name\": \"Can KL-400SSMBK work with connectors from other brands?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Absolutely. The K-LOK 400A series uses the industry-standard CAM-type interface, so KL-400SSMBK mates directly with compatible single-pole connectors regardless of manufacturer. This makes it easy to expand or upgrade your connector stock incrementally.\"}}, {\"@type\": \"Question\", \"name\": \"What is the advantage of the double set screw design on KL-400SSMBK?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The double set screw termination on KL-400SSMBK provides redundant cable clamping - each screw independently secures the conductor, adding a layer of safety against vibration-induced loosening. This is particularly valuable in touring rigs and mobile power systems where connectors experience constant mechanical stress.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400SSMBK\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003c!-- No spec-sheet download link provided in source CSV. --\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Panel Mount Receptacle","offer_id":50208820887772,"sku":"KL-400SSMBK","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400SSMBK.jpg?v=1777362842"},{"product_id":"kl-400ssmbn","title":"KL-400SSMBN - K-LOK 400A Male CAM-Type Panel Mount Receptacle, Double Set Screw, Brown","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400SSMBN --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400SSMBN\" data-color=\"Brown\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Male Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eDouble set screw panel-mount design provides redundant cable retention for maximum security in permanent installations\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding conditions in fixed enclosure installations\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors\u003c\/li\u003e\n      \u003cli\u003eMounting holes enable secure attachment to enclosures, distro boxes, and panel assemblies\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing inline connectors from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Male Panel Mount Receptacle intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400SSMBN | K-LOK 400A Single-Pole Panel Mount Receptacle, Male (Double Set Screw Type), Brown, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Male Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400SSMBN\",\n  \"mpn\": \"KL-400SSMBN\",\n  \"color\": \"Brown\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Mount Receptacle (Double Set Screw)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Male\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Brown\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Phase A (IEC)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screw (2 x 7\/32\\\" socket head)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400SSMBN\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWho should use KL-400SSMBN and why?\u003c\/h3\u003e\n    \u003cp\u003eLighting technicians, electricians, and power distribution professionals working with 400A temporary power systems will benefit from KL-400SSMBN. Its brown housing provides instant visual phase identification, while the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius ensures durability in demanding field conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat voltage and amperage is KL-400SSMBN rated for?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMBN carries a maximum rating of 400A and 600V AC\/DC. It accepts wire gauges from #6 to 4\/0 AWG, making it suitable for the conductor sizes typically used in 400-amp power distribution circuits.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhy choose the brown version of the K-LOK 400A male panel mount receptacle?\u003c\/h3\u003e\n    \u003cp\u003eBrown designates Phase A (L1) under IEC 60446 conventions used across Europe, the UK, Asia, and Australia. For productions touring internationally or venues hosting global acts, brown connectors ensure IEC-standard phase identification is always available. Choosing KL-400SSMBN in brown ensures your power distribution system follows established color conventions, speeding up setup and reducing wiring errors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs KL-400SSMBN UL listed and what does that mean?\u003c\/h3\u003e\n    \u003cp\u003eYes. KL-400SSMBN is cUL Listed under File Number E332947, meaning it has been independently tested and certified to UL 1691 safety standards by a Nationally Recognized Testing Laboratory. This certification is required for professional power distribution in most North American jurisdictions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat industries commonly use KL-400SSMBN?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMBN is widely used in industrial temporary power connections for manufacturing and processing facilities. Its 400A \/ 600V AC\/DC rating, combined with CAM-type universal compatibility and brown phase coding, makes it a versatile choice across the entertainment, construction, and industrial sectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is KL-400SSMBN installed in a power distribution enclosure?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMBN uses a double set screw panel-mount design with dedicated mounting holes for secure attachment to enclosures and distro boxes. The double set screw termination provides redundant cable retention - two independent screws clamp the conductor, so even if one loosens under vibration, the connection remains intact.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Who should use KL-400SSMBN and why?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Lighting technicians, electricians, and power distribution professionals working with 400A temporary power systems will benefit from KL-400SSMBN. Its brown housing provides instant visual phase identification, while the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius ensures durability in demanding field conditions.\"}}, {\"@type\": \"Question\", \"name\": \"What voltage and amperage is KL-400SSMBN rated for?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMBN carries a maximum rating of 400A and 600V AC\/DC. It accepts wire gauges from #6 to 4\/0 AWG, making it suitable for the conductor sizes typically used in 400-amp power distribution circuits.\"}}, {\"@type\": \"Question\", \"name\": \"Why choose the brown version of the K-LOK 400A male panel mount receptacle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Brown designates Phase A (L1) under IEC 60446 conventions used across Europe, the UK, Asia, and Australia. For productions touring internationally or venues hosting global acts, brown connectors ensure IEC-standard phase identification is always available. Choosing KL-400SSMBN in brown ensures your power distribution system follows established color conventions, speeding up setup and reducing wiring errors.\"}}, {\"@type\": \"Question\", \"name\": \"Is KL-400SSMBN UL listed and what does that mean?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. KL-400SSMBN is cUL Listed under File Number E332947, meaning it has been independently tested and certified to UL 1691 safety standards by a Nationally Recognized Testing Laboratory. This certification is required for professional power distribution in most North American jurisdictions.\"}}, {\"@type\": \"Question\", \"name\": \"What industries commonly use KL-400SSMBN?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMBN is widely used in industrial temporary power connections for manufacturing and processing facilities. Its 400A \/ 600V AC\/DC rating, combined with CAM-type universal compatibility and brown phase coding, makes it a versatile choice across the entertainment, construction, and industrial sectors.\"}}, {\"@type\": \"Question\", \"name\": \"How is KL-400SSMBN installed in a power distribution enclosure?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMBN uses a double set screw panel-mount design with dedicated mounting holes for secure attachment to enclosures and distro boxes. The double set screw termination provides redundant cable retention - two independent screws clamp the conductor, so even if one loosens under vibration, the connection remains intact.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400SSMBN\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003c!-- No spec-sheet download link provided in source CSV. --\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Panel Mount Receptacle","offer_id":50208820920540,"sku":"KL-400SSMBN","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400SSMBN_b.jpg?v=1777362843"},{"product_id":"kl-400ssmg","title":"KL-400SSMG - K-LOK 400A Male CAM-Type Panel Mount Receptacle, Double Set Screw, Green","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400SSMG --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400SSMG\" data-color=\"Green\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Male Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eDouble set screw panel-mount design provides redundant cable retention for maximum security in permanent installations\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding conditions in fixed enclosure installations\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors\u003c\/li\u003e\n      \u003cli\u003eMounting holes enable secure attachment to enclosures, distro boxes, and panel assemblies\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing inline connectors from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Male Panel Mount Receptacle intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400SSMG | K-LOK 400A Single-Pole Panel Mount Receptacle, Male (Double Set Screw Type), Green, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Male Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400SSMG\",\n  \"mpn\": \"KL-400SSMG\",\n  \"color\": \"Green\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Mount Receptacle (Double Set Screw)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Male\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Green\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Ground \/ Earth\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screw (2 x 7\/32\\\" socket head)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400SSMG\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat kind of connector is KL-400SSMG?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMG is a 400-ampere, 600V AC\/DC single-pole male panel mount receptacle (Double Set Screw Type) from the KUPO K-LOK series. Finished in green, it belongs to the CAM-type connector family widely used across live events, film production, and temporary industrial power systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current can KL-400SSMG safely carry?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMG is designed for a maximum continuous load of 400 amperes at up to 600V AC\/DC. The brass contacts and Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius work together to maintain safe operating temperatures even under sustained full-load conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does the green color coding on KL-400SSMG help on a busy job site?\u003c\/h3\u003e\n    \u003cp\u003eOn a crowded set or event site, identifying conductors quickly is a safety essential. Green identifies the Ground (Earth \/ PE) conductor across North American and many international standards. Ground integrity is critical for personnel safety, and a distinct green connector ensures the safety earth is never confused with a current-carrying phase. The green KL-400SSMG connector lets technicians trace circuits visually without needing to check labels or test equipment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety certifications does KL-400SSMG hold?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMG is cUL Listed under File Number E332947, certified to UL 1691 - the Standard for Safety for Cam-Type, Locking-Type Separable Connectors. It carries a UL Enclosure Types 3R environment rating, HB \/ UL94 flame classification, and full RoHS (Restriction of Hazardous Substances) compliance.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eCan KL-400SSMG work with connectors from other brands?\u003c\/h3\u003e\n    \u003cp\u003eAbsolutely. The K-LOK 400A series uses the industry-standard CAM-type interface, so KL-400SSMG mates directly with compatible single-pole connectors regardless of manufacturer. This makes it easy to expand or upgrade your connector stock incrementally.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat housing material is used in KL-400SSMG and why does it matter?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMG uses a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius. Santoprene TPV is chosen for its combination of rubber-like flexibility, heat resistance up to 105 degrees Celsius, and resistance to oils, chemicals, and weathering - ideal for panel mount receptacles that remain permanently installed in demanding environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What kind of connector is KL-400SSMG?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMG is a 400-ampere, 600V AC\/DC single-pole male panel mount receptacle (Double Set Screw Type) from the KUPO K-LOK series. Finished in green, it belongs to the CAM-type connector family widely used across live events, film production, and temporary industrial power systems.\"}}, {\"@type\": \"Question\", \"name\": \"How much current can KL-400SSMG safely carry?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMG is designed for a maximum continuous load of 400 amperes at up to 600V AC\/DC. The brass contacts and Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius work together to maintain safe operating temperatures even under sustained full-load conditions.\"}}, {\"@type\": \"Question\", \"name\": \"How does the green color coding on KL-400SSMG help on a busy job site?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"On a crowded set or event site, identifying conductors quickly is a safety essential. Green identifies the Ground (Earth \/ PE) conductor across North American and many international standards. Ground integrity is critical for personnel safety, and a distinct green connector ensures the safety earth is never confused with a current-carrying phase. The green KL-400SSMG connector lets technicians trace circuits visually without needing to check labels or test equipment.\"}}, {\"@type\": \"Question\", \"name\": \"What safety certifications does KL-400SSMG hold?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMG is cUL Listed under File Number E332947, certified to UL 1691 - the Standard for Safety for Cam-Type, Locking-Type Separable Connectors. It carries a UL Enclosure Types 3R environment rating, HB \/ UL94 flame classification, and full RoHS (Restriction of Hazardous Substances) compliance.\"}}, {\"@type\": \"Question\", \"name\": \"Can KL-400SSMG work with connectors from other brands?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Absolutely. The K-LOK 400A series uses the industry-standard CAM-type interface, so KL-400SSMG mates directly with compatible single-pole connectors regardless of manufacturer. This makes it easy to expand or upgrade your connector stock incrementally.\"}}, {\"@type\": \"Question\", \"name\": \"What housing material is used in KL-400SSMG and why does it matter?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMG uses a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius. Santoprene TPV is chosen for its combination of rubber-like flexibility, heat resistance up to 105 degrees Celsius, and resistance to oils, chemicals, and weathering - ideal for panel mount receptacles that remain permanently installed in demanding environments.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400SSMG\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003c!-- No spec-sheet download link provided in source CSV. --\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Panel Mount Receptacle","offer_id":50208820953308,"sku":"KL-400SSMG","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400SSMG.jpg?v=1777362844"},{"product_id":"kl-400ssmgy","title":"KL-400SSMGY - K-LOK 400A Male CAM-Type Panel Mount Receptacle, Double Set Screw, Grey","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400SSMGY --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400SSMGY\" data-color=\"Grey\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Male Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eDouble set screw panel-mount design provides redundant cable retention for maximum security in permanent installations\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding conditions in fixed enclosure installations\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors\u003c\/li\u003e\n      \u003cli\u003eMounting holes enable secure attachment to enclosures, distro boxes, and panel assemblies\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing inline connectors from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Male Panel Mount Receptacle intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400SSMGY | K-LOK 400A Single-Pole Panel Mount Receptacle, Male (Double Set Screw Type), Grey, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Male Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400SSMGY\",\n  \"mpn\": \"KL-400SSMGY\",\n  \"color\": \"Grey\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Mount Receptacle (Double Set Screw)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Male\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Grey\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Neutral (IEC)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screw (2 x 7\/32\\\" socket head)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400SSMGY\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does KL-400SSMGY do and where is it typically used?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMGY provides a safe, reliable single-pole male connection point for 400A circuits at up to 600V AC\/DC. As a panel mount receptacle with grey color coding, it is commonly used in professional entertainment power distribution, temporary construction feeds, and industrial installations.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat are the electrical ratings of KL-400SSMGY?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMGY is rated for 400 amperes maximum continuous current at 600V AC\/DC maximum. It accepts conductors from #6 to 4\/0 AWG (American Wire Gauge), with brass contacts delivering low-resistance connections for sustained high-current loads.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the grey housing on KL-400SSMGY signify?\u003c\/h3\u003e\n    \u003cp\u003eGrey represents Phase C (L3) - and in some IEC applications, Neutral - under the international color code. Adding grey to the connector inventory ensures full IEC three-phase coverage alongside brown and black. Color-coded connectors like KL-400SSMGY allow crews to visually verify correct phase wiring at a glance, which is especially valuable during fast-paced load-ins and load-outs.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety standards apply to KL-400SSMGY?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMGY meets UL 1691 (Cam-Type, Locking-Type Separable Connectors), is cUL Listed under E332947, rated UL Enclosure Types 3R for weather resistance, carries a HB \/ UL94 flame class, and complies with RoHS hazardous substance restrictions. These certifications collectively ensure the connector is safe for professional use in entertainment and industrial environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhere is KL-400SSMGY commonly deployed?\u003c\/h3\u003e\n    \u003cp\u003eYou will find KL-400SSMGY at work in studio power distribution in recording, post-production, and live broadcast environments. The grey color coding and 400-amp capacity make it particularly well suited for multi-phase power distribution in professional settings.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the advantage of the double set screw design on KL-400SSMGY?\u003c\/h3\u003e\n    \u003cp\u003eThe double set screw termination on KL-400SSMGY provides redundant cable clamping - each screw independently secures the conductor, adding a layer of safety against vibration-induced loosening. This is particularly valuable in touring rigs and mobile power systems where connectors experience constant mechanical stress.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What does KL-400SSMGY do and where is it typically used?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMGY provides a safe, reliable single-pole male connection point for 400A circuits at up to 600V AC\/DC. As a panel mount receptacle with grey color coding, it is commonly used in professional entertainment power distribution, temporary construction feeds, and industrial installations.\"}}, {\"@type\": \"Question\", \"name\": \"What are the electrical ratings of KL-400SSMGY?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMGY is rated for 400 amperes maximum continuous current at 600V AC\/DC maximum. It accepts conductors from #6 to 4\/0 AWG (American Wire Gauge), with brass contacts delivering low-resistance connections for sustained high-current loads.\"}}, {\"@type\": \"Question\", \"name\": \"What does the grey housing on KL-400SSMGY signify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Grey represents Phase C (L3) - and in some IEC applications, Neutral - under the international color code. Adding grey to the connector inventory ensures full IEC three-phase coverage alongside brown and black. Color-coded connectors like KL-400SSMGY allow crews to visually verify correct phase wiring at a glance, which is especially valuable during fast-paced load-ins and load-outs.\"}}, {\"@type\": \"Question\", \"name\": \"What safety standards apply to KL-400SSMGY?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMGY meets UL 1691 (Cam-Type, Locking-Type Separable Connectors), is cUL Listed under E332947, rated UL Enclosure Types 3R for weather resistance, carries a HB \/ UL94 flame class, and complies with RoHS hazardous substance restrictions. These certifications collectively ensure the connector is safe for professional use in entertainment and industrial environments.\"}}, {\"@type\": \"Question\", \"name\": \"Where is KL-400SSMGY commonly deployed?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"You will find KL-400SSMGY at work in studio power distribution in recording, post-production, and live broadcast environments. The grey color coding and 400-amp capacity make it particularly well suited for multi-phase power distribution in professional settings.\"}}, {\"@type\": \"Question\", \"name\": \"What is the advantage of the double set screw design on KL-400SSMGY?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The double set screw termination on KL-400SSMGY provides redundant cable clamping - each screw independently secures the conductor, adding a layer of safety against vibration-induced loosening. This is particularly valuable in touring rigs and mobile power systems where connectors experience constant mechanical stress.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400SSMGY\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003c!-- No spec-sheet download link provided in source CSV. --\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Panel Mount Receptacle","offer_id":50208820986076,"sku":"KL-400SSMGY","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400SSMGY_b.jpg?v=1777362846"},{"product_id":"kl-400ssmo","title":"KL-400SSMO - K-LOK 400A Male CAM-Type Panel Mount Receptacle, Double Set Screw, Orange","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400SSMO --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400SSMO\" data-color=\"Orange\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Male Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eDouble set screw panel-mount design provides redundant cable retention for maximum security in permanent installations\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding conditions in fixed enclosure installations\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors\u003c\/li\u003e\n      \u003cli\u003eMounting holes enable secure attachment to enclosures, distro boxes, and panel assemblies\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing inline connectors from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Male Panel Mount Receptacle intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400SSMO | K-LOK 400A Single-Pole Panel Mount Receptacle, Male (Double Set Screw Type), Orange, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Male Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400SSMO\",\n  \"mpn\": \"KL-400SSMO\",\n  \"color\": \"Orange\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Mount Receptacle (Double Set Screw)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Male\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Orange\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"High-Leg Delta \/ Special Identification\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screw (2 x 7\/32\\\" socket head)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400SSMO\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is KL-400SSMO and what is it designed for?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMO is a KUPO K-LOK 400A single-pole male panel mount receptacle (Double Set Screw Type) with a orange housing, rated for 600V AC\/DC maximum. It is engineered for heavy-duty temporary power distribution in entertainment, industrial, and event production settings. The orange color coding aids rapid phase identification on the job site.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat wire sizes does KL-400SSMO accept?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMO accommodates conductors ranging from #6 to 4\/0 AWG. The brass contact assembly ensures reliable electrical performance across this full conductor range, supporting up to 400A at 600V AC\/DC.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhich electrical phase does the orange color represent on KL-400SSMO?\u003c\/h3\u003e\n    \u003cp\u003eOrange is traditionally reserved for high-leg delta circuits and other specialty applications in North America. It provides an unmistakable visual warning that a conductor carries a voltage different from the standard phases - critical information for electricians working with delta transformer configurations. Having a dedicated orange connector in your inventory means phase assignments are physically enforced, minimizing the chance of cross-phase connection errors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does KL-400SSMO protect against electrical hazards?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMO incorporates multiple safety features: the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius resists heat and impact, brass contacts minimize resistive heating, and the design meets UL 1691 safety requirements under cUL Listed E332947. The UL Enclosure Types 3R rating also provides protection in wet or outdoor conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs KL-400SSMO compatible with other CAM-type connectors?\u003c\/h3\u003e\n    \u003cp\u003eYes. KL-400SSMO follows the universal CAM-type single-pole connector standard and intermates with CAM-type connectors from all major manufacturers. This cross-brand compatibility means you can integrate K-LOK connectors into existing power distribution systems without replacing your entire inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is KL-400SSMO and what is it designed for?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMO is a KUPO K-LOK 400A single-pole male panel mount receptacle (Double Set Screw Type) with a orange housing, rated for 600V AC\/DC maximum. It is engineered for heavy-duty temporary power distribution in entertainment, industrial, and event production settings. The orange color coding aids rapid phase identification on the job site.\"}}, {\"@type\": \"Question\", \"name\": \"What wire sizes does KL-400SSMO accept?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMO accommodates conductors ranging from #6 to 4\/0 AWG. The brass contact assembly ensures reliable electrical performance across this full conductor range, supporting up to 400A at 600V AC\/DC.\"}}, {\"@type\": \"Question\", \"name\": \"Which electrical phase does the orange color represent on KL-400SSMO?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Orange is traditionally reserved for high-leg delta circuits and other specialty applications in North America. It provides an unmistakable visual warning that a conductor carries a voltage different from the standard phases - critical information for electricians working with delta transformer configurations. Having a dedicated orange connector in your inventory means phase assignments are physically enforced, minimizing the chance of cross-phase connection errors.\"}}, {\"@type\": \"Question\", \"name\": \"How does KL-400SSMO protect against electrical hazards?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMO incorporates multiple safety features: the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius resists heat and impact, brass contacts minimize resistive heating, and the design meets UL 1691 safety requirements under cUL Listed E332947. The UL Enclosure Types 3R rating also provides protection in wet or outdoor conditions.\"}}, {\"@type\": \"Question\", \"name\": \"Is KL-400SSMO compatible with other CAM-type connectors?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. KL-400SSMO follows the universal CAM-type single-pole connector standard and intermates with CAM-type connectors from all major manufacturers. This cross-brand compatibility means you can integrate K-LOK connectors into existing power distribution systems without replacing your entire inventory.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400SSMO\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003c!-- No spec-sheet download link provided in source CSV. --\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Panel Mount Receptacle","offer_id":50208821051612,"sku":"KL-400SSMO","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400SSMO_b.jpg?v=1777362847"},{"product_id":"kl-400ssmr","title":"KL-400SSMR - K-LOK 400A Male CAM-Type Panel Mount Receptacle, Double Set Screw, Red","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400SSMR --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400SSMR\" data-color=\"Red\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Male Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eDouble set screw panel-mount design provides redundant cable retention for maximum security in permanent installations\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding conditions in fixed enclosure installations\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors\u003c\/li\u003e\n      \u003cli\u003eMounting holes enable secure attachment to enclosures, distro boxes, and panel assemblies\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing inline connectors from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Male Panel Mount Receptacle intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400SSMR | K-LOK 400A Single-Pole Panel Mount Receptacle, Male (Double Set Screw Type), Red, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Male Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400SSMR\",\n  \"mpn\": \"KL-400SSMR\",\n  \"color\": \"Red\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Mount Receptacle (Double Set Screw)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Male\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Red\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Phase B\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screw (2 x 7\/32\\\" socket head)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400SSMR\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWho should use KL-400SSMR and why?\u003c\/h3\u003e\n    \u003cp\u003eLighting technicians, electricians, and power distribution professionals working with 400A temporary power systems will benefit from KL-400SSMR. Its red housing provides instant visual phase identification, while the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius ensures durability in demanding field conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat voltage and amperage is KL-400SSMR rated for?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMR carries a maximum rating of 400A and 600V AC\/DC. It accepts wire gauges from #6 to 4\/0 AWG, making it suitable for the conductor sizes typically used in 400-amp power distribution circuits.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhy choose the red version of the K-LOK 400A male panel mount receptacle?\u003c\/h3\u003e\n    \u003cp\u003eRed marks Phase B (L2) in North American wiring and Phase C (L3) under Chinese GB 50303 standards. It is one of the most visually distinctive colors on a busy job site, helping crews quickly trace the second phase conductor. Choosing KL-400SSMR in red ensures your power distribution system follows established color conventions, speeding up setup and reducing wiring errors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs KL-400SSMR UL listed and what does that mean?\u003c\/h3\u003e\n    \u003cp\u003eYes. KL-400SSMR is cUL Listed under File Number E332947, meaning it has been independently tested and certified to UL 1691 safety standards by a Nationally Recognized Testing Laboratory. This certification is required for professional power distribution in most North American jurisdictions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat industries commonly use KL-400SSMR?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMR is widely used in broadcast operations and outside broadcast (OB) van power distribution. Its 400A \/ 600V AC\/DC rating, combined with CAM-type universal compatibility and red phase coding, makes it a versatile choice across the entertainment, construction, and industrial sectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat housing material is used in KL-400SSMR and why does it matter?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMR uses a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius. Santoprene TPV is chosen for its combination of rubber-like flexibility, heat resistance up to 105 degrees Celsius, and resistance to oils, chemicals, and weathering - ideal for panel mount receptacles that remain permanently installed in demanding environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Who should use KL-400SSMR and why?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Lighting technicians, electricians, and power distribution professionals working with 400A temporary power systems will benefit from KL-400SSMR. Its red housing provides instant visual phase identification, while the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius ensures durability in demanding field conditions.\"}}, {\"@type\": \"Question\", \"name\": \"What voltage and amperage is KL-400SSMR rated for?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMR carries a maximum rating of 400A and 600V AC\/DC. It accepts wire gauges from #6 to 4\/0 AWG, making it suitable for the conductor sizes typically used in 400-amp power distribution circuits.\"}}, {\"@type\": \"Question\", \"name\": \"Why choose the red version of the K-LOK 400A male panel mount receptacle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Red marks Phase B (L2) in North American wiring and Phase C (L3) under Chinese GB 50303 standards. It is one of the most visually distinctive colors on a busy job site, helping crews quickly trace the second phase conductor. Choosing KL-400SSMR in red ensures your power distribution system follows established color conventions, speeding up setup and reducing wiring errors.\"}}, {\"@type\": \"Question\", \"name\": \"Is KL-400SSMR UL listed and what does that mean?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. KL-400SSMR is cUL Listed under File Number E332947, meaning it has been independently tested and certified to UL 1691 safety standards by a Nationally Recognized Testing Laboratory. This certification is required for professional power distribution in most North American jurisdictions.\"}}, {\"@type\": \"Question\", \"name\": \"What industries commonly use KL-400SSMR?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMR is widely used in broadcast operations and outside broadcast (OB) van power distribution. Its 400A \/ 600V AC\/DC rating, combined with CAM-type universal compatibility and red phase coding, makes it a versatile choice across the entertainment, construction, and industrial sectors.\"}}, {\"@type\": \"Question\", \"name\": \"What housing material is used in KL-400SSMR and why does it matter?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMR uses a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius. Santoprene TPV is chosen for its combination of rubber-like flexibility, heat resistance up to 105 degrees Celsius, and resistance to oils, chemicals, and weathering - ideal for panel mount receptacles that remain permanently installed in demanding environments.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400SSMR\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003c!-- No spec-sheet download link provided in source CSV. --\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Panel Mount Receptacle","offer_id":50208821117148,"sku":"KL-400SSMR","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400SSMR.jpg?v=1777362848"},{"product_id":"kl-400ssmw","title":"KL-400SSMW - K-LOK 400A Male CAM-Type Panel Mount Receptacle, Double Set Screw, White","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400SSMW --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400SSMW\" data-color=\"White\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Male Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eDouble set screw panel-mount design provides redundant cable retention for maximum security in permanent installations\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding conditions in fixed enclosure installations\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors\u003c\/li\u003e\n      \u003cli\u003eMounting holes enable secure attachment to enclosures, distro boxes, and panel assemblies\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing inline connectors from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Male Panel Mount Receptacle intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400SSMW | K-LOK 400A Single-Pole Panel Mount Receptacle, Male (Double Set Screw Type), White, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Male Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400SSMW\",\n  \"mpn\": \"KL-400SSMW\",\n  \"color\": \"White\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Mount Receptacle (Double Set Screw)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Male\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"White\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Neutral\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screw (2 x 7\/32\\\" socket head)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400SSMW\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is KL-400SSMW and what is it designed for?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMW is a KUPO K-LOK 400A single-pole male panel mount receptacle (Double Set Screw Type) with a white housing, rated for 600V AC\/DC maximum. It is engineered for heavy-duty temporary power distribution in entertainment, industrial, and event production settings. The white color coding aids rapid phase identification on the job site.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat wire sizes does KL-400SSMW accept?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMW accommodates conductors ranging from #6 to 4\/0 AWG. The brass contact assembly ensures reliable electrical performance across this full conductor range, supporting up to 400A at 600V AC\/DC.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhich electrical phase does the white color represent on KL-400SSMW?\u003c\/h3\u003e\n    \u003cp\u003eWhite is universally recognized in North America as the Neutral conductor per NEC conventions. Using a dedicated white connector for neutral runs eliminates guesswork during setup and teardown, reducing the risk of miswired circuits. Having a dedicated white connector in your inventory means phase assignments are physically enforced, minimizing the chance of cross-phase connection errors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does KL-400SSMW protect against electrical hazards?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMW incorporates multiple safety features: the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius resists heat and impact, brass contacts minimize resistive heating, and the design meets UL 1691 safety requirements under cUL Listed E332947. The UL Enclosure Types 3R rating also provides protection in wet or outdoor conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs KL-400SSMW compatible with other CAM-type connectors?\u003c\/h3\u003e\n    \u003cp\u003eYes. KL-400SSMW follows the universal CAM-type single-pole connector standard and intermates with CAM-type connectors from all major manufacturers. This cross-brand compatibility means you can integrate K-LOK connectors into existing power distribution systems without replacing your entire inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the advantage of the double set screw design on KL-400SSMW?\u003c\/h3\u003e\n    \u003cp\u003eThe double set screw termination on KL-400SSMW provides redundant cable clamping - each screw independently secures the conductor, adding a layer of safety against vibration-induced loosening. This is particularly valuable in touring rigs and mobile power systems where connectors experience constant mechanical stress.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is KL-400SSMW and what is it designed for?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMW is a KUPO K-LOK 400A single-pole male panel mount receptacle (Double Set Screw Type) with a white housing, rated for 600V AC\/DC maximum. It is engineered for heavy-duty temporary power distribution in entertainment, industrial, and event production settings. The white color coding aids rapid phase identification on the job site.\"}}, {\"@type\": \"Question\", \"name\": \"What wire sizes does KL-400SSMW accept?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMW accommodates conductors ranging from #6 to 4\/0 AWG. The brass contact assembly ensures reliable electrical performance across this full conductor range, supporting up to 400A at 600V AC\/DC.\"}}, {\"@type\": \"Question\", \"name\": \"Which electrical phase does the white color represent on KL-400SSMW?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"White is universally recognized in North America as the Neutral conductor per NEC conventions. Using a dedicated white connector for neutral runs eliminates guesswork during setup and teardown, reducing the risk of miswired circuits. Having a dedicated white connector in your inventory means phase assignments are physically enforced, minimizing the chance of cross-phase connection errors.\"}}, {\"@type\": \"Question\", \"name\": \"How does KL-400SSMW protect against electrical hazards?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMW incorporates multiple safety features: the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius resists heat and impact, brass contacts minimize resistive heating, and the design meets UL 1691 safety requirements under cUL Listed E332947. The UL Enclosure Types 3R rating also provides protection in wet or outdoor conditions.\"}}, {\"@type\": \"Question\", \"name\": \"Is KL-400SSMW compatible with other CAM-type connectors?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. KL-400SSMW follows the universal CAM-type single-pole connector standard and intermates with CAM-type connectors from all major manufacturers. This cross-brand compatibility means you can integrate K-LOK connectors into existing power distribution systems without replacing your entire inventory.\"}}, {\"@type\": \"Question\", \"name\": \"What is the advantage of the double set screw design on KL-400SSMW?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The double set screw termination on KL-400SSMW provides redundant cable clamping - each screw independently secures the conductor, adding a layer of safety against vibration-induced loosening. This is particularly valuable in touring rigs and mobile power systems where connectors experience constant mechanical stress.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400SSMW\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003c!-- No spec-sheet download link provided in source CSV. --\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Panel Mount Receptacle","offer_id":50208821149916,"sku":"KL-400SSMW","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400SSMW.jpg?v=1777362850"},{"product_id":"kl-400ssmy","title":"KL-400SSMY - K-LOK 400A Male CAM-Type Panel Mount Receptacle, Double Set Screw, Yellow","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400SSMY --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400SSMY\" data-color=\"Yellow\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Male Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eDouble set screw panel-mount design provides redundant cable retention for maximum security in permanent installations\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding conditions in fixed enclosure installations\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors\u003c\/li\u003e\n      \u003cli\u003eMounting holes enable secure attachment to enclosures, distro boxes, and panel assemblies\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing inline connectors from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Male Panel Mount Receptacle intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400SSMY | K-LOK 400A Single-Pole Panel Mount Receptacle, Male (Double Set Screw Type), Yellow, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Male Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400SSMY\",\n  \"mpn\": \"KL-400SSMY\",\n  \"color\": \"Yellow\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Mount Receptacle (Double Set Screw)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Male\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Yellow\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Phase A (China GB 50303)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screw (2 x 7\/32\\\" socket head)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400SSMY\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat kind of connector is KL-400SSMY?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMY is a 400-ampere, 600V AC\/DC single-pole male panel mount receptacle (Double Set Screw Type) from the KUPO K-LOK series. Finished in yellow, it belongs to the CAM-type connector family widely used across live events, film production, and temporary industrial power systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current can KL-400SSMY safely carry?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMY is designed for a maximum continuous load of 400 amperes at up to 600V AC\/DC. The brass contacts and Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius work together to maintain safe operating temperatures even under sustained full-load conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does the yellow color coding on KL-400SSMY help on a busy job site?\u003c\/h3\u003e\n    \u003cp\u003eOn a crowded set or event site, identifying conductors quickly is a safety essential. Yellow identifies Phase A (L1) under China's GB 50303 standard and is also used for specialty marking in some North American installations. Its high-visibility color makes it an excellent choice for circuits that need to stand out for safety or identification purposes. The yellow KL-400SSMY connector lets technicians trace circuits visually without needing to check labels or test equipment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety certifications does KL-400SSMY hold?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMY is cUL Listed under File Number E332947, certified to UL 1691 - the Standard for Safety for Cam-Type, Locking-Type Separable Connectors. It carries a UL Enclosure Types 3R environment rating, HB \/ UL94 flame classification, and full RoHS (Restriction of Hazardous Substances) compliance.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eCan KL-400SSMY work with connectors from other brands?\u003c\/h3\u003e\n    \u003cp\u003eAbsolutely. The K-LOK 400A series uses the industry-standard CAM-type interface, so KL-400SSMY mates directly with compatible single-pole connectors regardless of manufacturer. This makes it easy to expand or upgrade your connector stock incrementally.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is KL-400SSMY installed in a power distribution enclosure?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSMY uses a double set screw panel-mount design with dedicated mounting holes for secure attachment to enclosures and distro boxes. The double set screw termination provides redundant cable retention - two independent screws clamp the conductor, so even if one loosens under vibration, the connection remains intact.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What kind of connector is KL-400SSMY?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMY is a 400-ampere, 600V AC\/DC single-pole male panel mount receptacle (Double Set Screw Type) from the KUPO K-LOK series. Finished in yellow, it belongs to the CAM-type connector family widely used across live events, film production, and temporary industrial power systems.\"}}, {\"@type\": \"Question\", \"name\": \"How much current can KL-400SSMY safely carry?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMY is designed for a maximum continuous load of 400 amperes at up to 600V AC\/DC. The brass contacts and Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius work together to maintain safe operating temperatures even under sustained full-load conditions.\"}}, {\"@type\": \"Question\", \"name\": \"How does the yellow color coding on KL-400SSMY help on a busy job site?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"On a crowded set or event site, identifying conductors quickly is a safety essential. Yellow identifies Phase A (L1) under China's GB 50303 standard and is also used for specialty marking in some North American installations. Its high-visibility color makes it an excellent choice for circuits that need to stand out for safety or identification purposes. The yellow KL-400SSMY connector lets technicians trace circuits visually without needing to check labels or test equipment.\"}}, {\"@type\": \"Question\", \"name\": \"What safety certifications does KL-400SSMY hold?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMY is cUL Listed under File Number E332947, certified to UL 1691 - the Standard for Safety for Cam-Type, Locking-Type Separable Connectors. It carries a UL Enclosure Types 3R environment rating, HB \/ UL94 flame classification, and full RoHS (Restriction of Hazardous Substances) compliance.\"}}, {\"@type\": \"Question\", \"name\": \"Can KL-400SSMY work with connectors from other brands?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Absolutely. The K-LOK 400A series uses the industry-standard CAM-type interface, so KL-400SSMY mates directly with compatible single-pole connectors regardless of manufacturer. This makes it easy to expand or upgrade your connector stock incrementally.\"}}, {\"@type\": \"Question\", \"name\": \"How is KL-400SSMY installed in a power distribution enclosure?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSMY uses a double set screw panel-mount design with dedicated mounting holes for secure attachment to enclosures and distro boxes. The double set screw termination provides redundant cable retention - two independent screws clamp the conductor, so even if one loosens under vibration, the connection remains intact.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400SSMY\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003c!-- No spec-sheet download link provided in source CSV. --\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Panel Mount Receptacle","offer_id":50208821182684,"sku":"KL-400SSMY","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400SSMY_b.jpg?v=1777362851"}],"url":"https:\/\/kupopower.com\/collections\/k-lok-400a-double-set-screw-panel-receptacles.oembed","provider":"KUPO Power","version":"1.0","type":"link"}