{"title":"PowerFit 400A Ground\/Earth Connectors","description":"\u003c!-- KUPO Power - PowerFit 400A Ground \/ Earth Connectors (TIER 2 - Mid-Tier Slice, Phase)\n     Shopify Collection Body HTML\n     Handle: powerfit-400a-ground-earth-connectors\n     URL: https:\/\/kupopower.com\/collections\/powerfit-400a-ground-earth-connectors --\u003e\n\n\u003cp\u003ePowerFit 400A connectors keyed for the Ground \/ Earth conductor (PE), the protective earth path required across all PowerFit 400A installations. IEC 60446 standard color: Green \/ Yellow stripe. The PE keying ensures the equipment grounding conductor is always connected first and disconnected last per safe-working practice, and physically prevents accidental connection to a live phase. This collection contains all PowerFit 400A SKUs configured for the PE position across all four form factors: Line Source, Line Drain, Panel Mount Source, and Panel Mount Drain.\u003c\/p\u003e\n\n\u003cp style=\"font-size:0.9rem; color:#666; margin-top:1rem;\"\u003eLooking for a different phase? Browse \u003ca href=\"https:\/\/kupopower.com\/collections\/powerfit-400a-phase-a-l1\"\u003ePhase A (L1)\u003c\/a\u003e · \u003ca href=\"https:\/\/kupopower.com\/collections\/powerfit-400a-phase-b-l2\"\u003ePhase B (L2)\u003c\/a\u003e · \u003ca href=\"https:\/\/kupopower.com\/collections\/powerfit-400a-phase-c-l3\"\u003ePhase C (L3)\u003c\/a\u003e · \u003ca href=\"https:\/\/kupopower.com\/collections\/powerfit-400a-neutral\"\u003eNeutral\u003c\/a\u003e · \u003ca href=\"https:\/\/kupopower.com\/collections\/powerfit-400a\"\u003eall PowerFit 400A\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"pfld-egn","title":"PFLD-EGN-S120M40A - PowerFit 400A Drain Line Connector, Green (PE)","description":"\u003c!-- Combined Shopify product HTML for PFLD-EGN-S120M40A --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLD-EGN-S120M40A\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Line Drain Connector (Green) | PFLD-EGN-S120M40A | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLD-EGN-S120M40A\" data-color=\"Green\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe protective earth (ground) conductor is the safety-critical backbone of any power distribution system. The PFLD-EGN-S120M40A delivers a robust, fault-tolerant connection for earth continuity at full 400A capacity, ensuring that fault currents are safely diverted and that live components remain isolated from human contact. This female contact line drain connector maintains the green insulation standard recognized across all major international electrical codes  -  a visual and functional guarantee of grounding integrity. With dual-rated 400A\/660A capacity and rated for 1000 volts AC or 1500 volts DC, this connector handles the demands of industrial and renewable energy systems where earth fault protection is non-negotiable.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 400A \/ 660A dual-rated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 1000V AC maximum \/ 1500V DC maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWithstand Voltage:\u003c\/strong\u003e 4500V test (three seconds)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit:\u003c\/strong\u003e 35.5 kilo-amperes symmetrical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Greater than 5000 megohms at 500V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Resistance:\u003c\/strong\u003e 0.1 milliohms nominal (at rated current)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e 45 to 85 degrees Celsius\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMating Cycles:\u003c\/strong\u003e 500 cycles minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP67 when mated\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTÜV:\u003c\/strong\u003e Certified to TÜV standard 1111303479\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Marking:\u003c\/strong\u003e Compliant with European Union directive requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Directive:\u003c\/strong\u003e Compliant with 2011\/65\/EU (Restriction of Hazardous Substances)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eREACH Regulation:\u003c\/strong\u003e Registered and compliant with EC 1907\/2006 (Registration, Evaluation, Authorisation, and Restriction of Chemicals)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL94-V0:\u003c\/strong\u003e Highest flame-resistance classification for housing material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eIndustrial power distribution and switchgear systems requiring redundant earth continuity\u003c\/li\u003e\n\u003cli\u003eRenewable energy installations (solar farms, wind facilities, battery energy storage systems) where ground fault protection is critical\u003c\/li\u003e\n\u003cli\u003eHeavy industrial machinery and process control systems operating at 400A or 660A capacity\u003c\/li\u003e\n\u003cli\u003eModular power distribution cabinets and portable power solutions\u003c\/li\u003e\n\u003cli\u003eMarine and offshore platforms where environmental conditions demand robust earth connections\u003c\/li\u003e\n\u003cli\u003eData center and telecommunications infrastructure requiring high fault current clearance\u003c\/li\u003e\n\u003cli\u003eAny system where earth conductor redundancy enhances safety margin and regulatory compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe PowerFit 400A Line Drain female contact connector is designed for plug compatibility with male contacts from major single-pole power connector families, enabling flexible system integration. The push-and-twist coupling mechanism (not CAM-type) is intuitive and reduces installation time while maintaining secure mechanical and electrical contact.\u003c\/p\u003e\n\u003cp\u003eCable gland accommodation: M40 x 1.5 thread (interior diameter 22 millimeters standard, or 33 millimeters with reduction sleeve). Accommodates cables up to 16.50 millimeters diameter when using the optional brass silver-plated reduction sleeve.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLD-EGN-S120M40A | PowerFit 400A Line Drain, Earth (PE) Green (Universal protective earth\/ground)\",\n  \"description\": \"KUPO PowerFit 400A Line Drain single-pole connector with green housing for Universal protective earth\/ground power distribution systems. Female Contact, M40 cable gland with sealing bushing, IP67 rated when mated, silver-plated brass contacts, dual-rated 400A\/660A, 1000V AC \/ 1500V DC maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLD-EGN-S120M40A\",\n  \"mpn\": \"PFLD-EGN-S120M40A\",\n  \"color\": \"Green\",\n  \"material\": \"Non-conductive thermoplastic housing; Brass silver-plated contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC \/ 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A continuous (120mm\u0026sup2; cable) \/ 660A continuous (240mm\u0026sup2; cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5 kiloamperes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Drain (Female Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-Twist Lock\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing (Inner Diameter: 22mm and 33mm)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Set Screw Torque\",\n      \"value\": \"10.5 N\/meter minimum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"TUV Certification ID\",\n      \"value\": \"1111303479\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV Rheinland, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Earth (PE) (Universal protective earth\/ground)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Green\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLD-EGN-S120M40A\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat kind of connector is PFLD-EGN-S120M40A and where does it fit in the power chain?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-EGN-S120M40A is a KUPO PowerFit 400A line drain connector with a green housing, designated for the Protective Earth (PE) conductor. As the drain side of an inline cable connection, it receives the mating source contact and provides a sealed, IP67-rated junction when coupled. The green housing enables instant visual identification of the PE conductor across cable runs. It is commonly deployed in mining and tunneling applications. Underground mining and tunnel construction require power distribution in confined, humid, dusty environments where safety standards are especially stringent and equipment must withstand harsh mechanical treatment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat are the electrical ratings and wire capacity of PFLD-EGN-S120M40A?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-EGN-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for PE circuits carrying continuous earth current.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhy is the green earth connector PFLD-EGN-S120M40A critical for safety?\u003c\/h3\u003e\n    \u003cp\u003eGreen identifies the Protective Earth (PE) conductor across virtually every international standard: NEC, IEC, Australian, old UK, and Chinese GB. Some regions specify green\/yellow striped, but solid green is universally recognized as earth ground. Ground conductor integrity is the most critical safety element in any power distribution system. On the Line Drain connector, the green housing is visible along the full 190mm body length, making PE identification easy even when cables are bundled tightly. The ergonomic rubber grip section also carries the color, so technicians can identify the phase while handling the connector. A distinct green connector ensures the safety earth is never confused with a current-carrying phase or neutral conductor. This is non-negotiable for personnel safety and equipment protection.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and safety ratings does PFLD-EGN-S120M40A carry?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-EGN-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The silicone O-ring seal contributes to the IP67 rating when mated, meaning the connection is fully protected against dust ingress and temporary immersion in water up to 1 meter for 30 minutes.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow do you assemble PFLD-EGN-S120M40A onto a power cable in the field?\u003c\/h3\u003e\n    \u003cp\u003eTo assemble PFLD-EGN-S120M40A, remove the M40 cable gland and extract the contact. Insert the contact into the insulator and align the cotter pin hole. Strip back the cable jacket by approximately 33mm, then slide the R120 reduction sleeve (brass with silver plating, up to 16.50mm wire diameter) over the exposed conductor. Hammer the cotter pin in from its chamfered side for proper seating. Slide the cable with reduction sleeve into the contact, then tighten both set screws using a 5mm hex key to a minimum of 10.5 N\/m. Finally, thread the cable gland back on. The M40 gland includes two rubber bushings (inner diameter 23mm and 33mm) for flexibility with different cable sizes. At 190mm total length with a 32.5mm body diameter, the Line Drain is the longest connector in the PowerFit family, providing ample space for cable management and a secure grip surface.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat advantages does PFLD-EGN-S120M40A offer over conventional CAM-type connectors?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-EGN-S120M40A offers several meaningful improvements over conventional single-pole power connectors: the 1000V AC \/ 1500V DC voltage rating exceeds the typical 600V maximum of traditional alternatives; silver-plated brass contacts deliver lower contact resistance (0.1 milliohms) than plain brass; the integrated M40 cable gland with sealing bushing provides cable strain relief and environmental protection in a single assembly; IP67 protection when mated provides dust-tight and waterproof sealing that most single-pole connectors lack. These features, combined with TUV Rheinland certification and the phase-encoded green housing for PE identification, make PowerFit a generation ahead of traditional designs.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What kind of connector is PFLD-EGN-S120M40A and where does it fit in the power chain?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-EGN-S120M40A is a KUPO PowerFit 400A line drain connector with a green housing, designated for the Protective Earth (PE) conductor. As the drain side of an inline cable connection, it receives the mating source contact and provides a sealed, IP67-rated junction when coupled. The green housing enables instant visual identification of the PE conductor across cable runs. It is commonly deployed in mining and tunneling applications. Underground mining and tunnel construction require power distribution in confined, humid, dusty environments where safety standards are especially stringent and equipment must withstand harsh mechanical treatment.\"}}, {\"@type\": \"Question\", \"name\": \"What are the electrical ratings and wire capacity of PFLD-EGN-S120M40A?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-EGN-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for PE circuits carrying continuous earth current.\"}}, {\"@type\": \"Question\", \"name\": \"Why is the green earth connector PFLD-EGN-S120M40A critical for safety?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Green identifies the Protective Earth (PE) conductor across virtually every international standard: NEC, IEC, Australian, old UK, and Chinese GB. Some regions specify green\/yellow striped, but solid green is universally recognized as earth ground. Ground conductor integrity is the most critical safety element in any power distribution system. On the Line Drain connector, the green housing is visible along the full 190mm body length, making PE identification easy even when cables are bundled tightly. The ergonomic rubber grip section also carries the color, so technicians can identify the phase while handling the connector. A distinct green connector ensures the safety earth is never confused with a current-carrying phase or neutral conductor. This is non-negotiable for personnel safety and equipment protection.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and safety ratings does PFLD-EGN-S120M40A carry?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-EGN-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The silicone O-ring seal contributes to the IP67 rating when mated, meaning the connection is fully protected against dust ingress and temporary immersion in water up to 1 meter for 30 minutes.\"}}, {\"@type\": \"Question\", \"name\": \"How do you assemble PFLD-EGN-S120M40A onto a power cable in the field?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"To assemble PFLD-EGN-S120M40A, remove the M40 cable gland and extract the contact. Insert the contact into the insulator and align the cotter pin hole. Strip back the cable jacket by approximately 33mm, then slide the R120 reduction sleeve (brass with silver plating, up to 16.50mm wire diameter) over the exposed conductor. Hammer the cotter pin in from its chamfered side for proper seating. Slide the cable with reduction sleeve into the contact, then tighten both set screws using a 5mm hex key to a minimum of 10.5 N\/m. Finally, thread the cable gland back on. The M40 gland includes two rubber bushings (inner diameter 23mm and 33mm) for flexibility with different cable sizes. At 190mm total length with a 32.5mm body diameter, the Line Drain is the longest connector in the PowerFit family, providing ample space for cable management and a secure grip surface.\"}}, {\"@type\": \"Question\", \"name\": \"What advantages does PFLD-EGN-S120M40A offer over conventional CAM-type connectors?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-EGN-S120M40A offers several meaningful improvements over conventional single-pole power connectors: the 1000V AC \/ 1500V DC voltage rating exceeds the typical 600V maximum of traditional alternatives; silver-plated brass contacts deliver lower contact resistance (0.1 milliohms) than plain brass; the integrated M40 cable gland with sealing bushing provides cable strain relief and environmental protection in a single assembly; IP67 protection when mated provides dust-tight and waterproof sealing that most single-pole connectors lack. These features, combined with TUV Rheinland certification and the phase-encoded green housing for PE identification, make PowerFit a generation ahead of traditional designs.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLD-EGN-S120M40A\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLD-EGN-S120M40A.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLD-EGN-S120M40A Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 400A \/ Inline Connector","offer_id":50208842973404,"sku":"PFLD-EGN-S120M40A","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLD-EGN-S120M40A-b.jpg?v=1777364434"},{"product_id":"pfls-egn","title":"PFLS-EGN-S120M40A - PowerFit 400A Source Line Connector, Green (PE)","description":"\u003c!-- Combined Shopify product HTML for PFLS-EGN-S120M40A --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLS-EGN-S120M40A\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Line Source Connector (Green) | PFLS-EGN-S120M40A | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLS-EGN-S120M40A\" data-color=\"Green\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLS-EGN-S120M40A is a 400A inline cable connector for protective earth (PE \/ ground) distribution, delivering the unambiguous safety-critical function that universal green coloring guarantees across all electrical standards. This Line Source connector houses the male contact and patent key-release pin, enabling tool-free disconnection while maintaining a reliable, low-resistance ground path. Earth is a life-safety function - this connector ensures it is installed, mated, and maintained with confidence.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eGreen (or green-with-yellow stripe) denotes protective earth across every major electrical convention: IEC, NEC, UK, Australia, and beyond. This universal convention eliminates any possibility of earth-phase confusion, ensuring that every technician worldwide recognizes this connector's critical safety function.\u003c\/li\u003e\n      \u003cli\u003eThe earth connector completes the fault-current path that protects personnel and equipment. Low contact resistance (0.1 milliohms) and high insulation integrity (\u0026gt;5000M Ohms) ensure that the ground path remains reliable under fault conditions, allowing protective devices to operate instantaneously.\u003c\/li\u003e\n      \u003cli\u003eThe male contact and key-release mechanism enable deliberate, controlled disconnection without tools. When performing maintenance or equipment shutdown, the earth connection is released only when explicitly commanded, preventing inadvertent loss of ground protection.\u003c\/li\u003e\n      \u003cli\u003eThe source variant uses a shorter polyoxymethylene (POM) cotter pin optimized for cable-mounted operation. Field disassembly with a small slotted screwdriver allows inspection and maintenance of the earth contact without specialized tools, ensuring the ground path integrity during commissioning and troubleshooting.\u003c\/li\u003e\n      \u003cli\u003eRated for 400A continuous with 120mm² cable, scaling to 660A with 240mm² cable. Fault-current capacity (35.5kA short circuit) ensures the earth contact can safely dissipate fault energy without melting or disconnecting.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eTÜV Rheinland certified (ID 1111303479), CE marked, RoHS, and REACH compliant. Meets all international requirements for protective earth circuits in machinery, industrial control, and power distribution systems.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePersonnel Protection:\u003c\/strong\u003e Industrial distribution centers, renewable energy systems, and heavy machinery requiring fault-current paths\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquipment Safety:\u003c\/strong\u003e UPS systems, power conditioning, and critical load centers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Installation:\u003c\/strong\u003e IP67 sealing protects ground circuits in weather-exposed environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Cycle Environments:\u003c\/strong\u003e 500-cycle rated for frequent maintenance and reconfigurations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmergency Shutdown Systems:\u003c\/strong\u003e Reliable earth disconnection during controlled power-down procedures\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRenewable Energy:\u003c\/strong\u003e Solar and wind installations requiring robust ground paths to earth rods or grids\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-EGN-S120M40A mates with corresponding PFLD (Line Drain) connectors and PFPS\/PFPD panel-mount variants. Compatible with major brands of single-pole power connectors. R120 reduction sleeve (brass, silver-plated) accommodates up to 16.50mm diameter wire for large-gauge earth conductors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLS-EGN-S120M40A | PowerFit 400A Line Source, Earth (PE) Green (Universal protective earth\/ground)\",\n  \"description\": \"KUPO PowerFit 400A Line Source single-pole connector with green housing for Universal protective earth\/ground power distribution systems. Male Contact, patent key-release pin for safe disconnection, M40 cable gland with sealing bushing, IP67 rated when mated, silver-plated brass contacts, dual-rated 400A\/660A, 1000V AC \/ 1500V DC maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLS-EGN-S120M40A\",\n  \"mpn\": \"PFLS-EGN-S120M40A\",\n  \"color\": \"Green\",\n  \"material\": \"Non-conductive thermoplastic housing; Brass silver-plated contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC \/ 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A continuous (120mm\u0026sup2; cable) \/ 660A continuous (240mm\u0026sup2; cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5 kiloamperes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Source (Male Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-Twist with Key-Release Mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cotter Pin Material\",\n      \"value\": \"POM (Polyoxymethylene)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing (Inner Diameter: 22mm and 33mm)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Set Screw Torque\",\n      \"value\": \"10.5 N\/meter minimum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"TUV Certification ID\",\n      \"value\": \"1111303479\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV Rheinland, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Earth (PE) (Universal protective earth\/ground)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Green\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLS-EGN-S120M40A\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does PFLS-EGN-S120M40A improve on traditional single-pole power connectors?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-EGN-S120M40A is a KUPO PowerFit 400A line source connector with a green housing, designated for the Protective Earth (PE) conductor. As the source side of an inline cable connection, it features the innovative patent key-release pin that enables tool-free disconnection. The push-and-twist mechanism secures the connection during operation while allowing rapid uncoupling when needed. It is commonly deployed in mining and tunneling applications. Underground mining and tunnel construction require power distribution in confined, humid, dusty environments where safety standards are especially stringent and equipment must withstand harsh mechanical treatment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat electrical performance does PFLS-EGN-S120M40A deliver?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-EGN-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for PE circuits carrying continuous earth current.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the green housing on PFLS-EGN-S120M40A signify and why does it matter?\u003c\/h3\u003e\n    \u003cp\u003eGreen identifies the Protective Earth (PE) conductor across virtually every international standard: NEC, IEC, Australian, old UK, and Chinese GB. Some regions specify green\/yellow striped, but solid green is universally recognized as earth ground. Ground conductor integrity is the most critical safety element in any power distribution system. On the Line Source connector, the green housing wraps the 170mm body including the area around the key-release mechanism. This means the phase is identifiable even during the push-and-twist connection process, reducing the chance of connecting to the wrong PE circuit. A distinct green connector ensures the safety earth is never confused with a current-carrying phase or neutral conductor. This is non-negotiable for personnel safety and equipment protection.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety certifications apply to PFLS-EGN-S120M40A?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-EGN-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The key-release pin mechanism has been certified as part of the TUV evaluation, ensuring that the disconnect feature meets the same safety standards as the connection itself.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs PFLS-EGN-S120M40A compatible with single-pole connectors from other manufacturers?\u003c\/h3\u003e\n    \u003cp\u003ePowerFit connectors are designed to be compatible with major brands of single-pole power connector. IP67 dust-tight and waterproof protection is critical underground, the 35.5 kA short circuit rating provides safety margin in high-fault-current mining distribution, and the non-conductive housing eliminates accidental current paths. For PE circuits using Universal (all regions) color conventions, the green PFLS-EGN-S120M40A ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does the key-release mechanism work on PFLS-EGN-S120M40A?\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-EGN-S120M40A features the innovative PowerFit push-and-twist connection. To connect, align the connector and push while twisting until it locks. To disconnect, the patent key-release pin enables tool-free uncoupling. Simply press the release and twist to separate. If needed, a small slotted screwdriver can assist with the release. For cable termination, the process follows the same steps as other PowerFit line connectors: strip 33mm of cable jacket, apply the reduction sleeve, tighten set screws to 10.5 N\/m minimum, and secure the M40 cable gland. Uses the shorter cotter pin variant (vs the longer pin in Line Drain). The shorter pin accommodates the key-release mechanism. Never reuse cotter pins.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"How does PFLS-EGN-S120M40A improve on traditional single-pole power connectors?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-EGN-S120M40A is a KUPO PowerFit 400A line source connector with a green housing, designated for the Protective Earth (PE) conductor. As the source side of an inline cable connection, it features the innovative patent key-release pin that enables tool-free disconnection. The push-and-twist mechanism secures the connection during operation while allowing rapid uncoupling when needed. It is commonly deployed in mining and tunneling applications. Underground mining and tunnel construction require power distribution in confined, humid, dusty environments where safety standards are especially stringent and equipment must withstand harsh mechanical treatment.\"}}, {\"@type\": \"Question\", \"name\": \"What electrical performance does PFLS-EGN-S120M40A deliver?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-EGN-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for PE circuits carrying continuous earth current.\"}}, {\"@type\": \"Question\", \"name\": \"What does the green housing on PFLS-EGN-S120M40A signify and why does it matter?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Green identifies the Protective Earth (PE) conductor across virtually every international standard: NEC, IEC, Australian, old UK, and Chinese GB. Some regions specify green\/yellow striped, but solid green is universally recognized as earth ground. Ground conductor integrity is the most critical safety element in any power distribution system. On the Line Source connector, the green housing wraps the 170mm body including the area around the key-release mechanism. This means the phase is identifiable even during the push-and-twist connection process, reducing the chance of connecting to the wrong PE circuit. A distinct green connector ensures the safety earth is never confused with a current-carrying phase or neutral conductor. This is non-negotiable for personnel safety and equipment protection.\"}}, {\"@type\": \"Question\", \"name\": \"What safety certifications apply to PFLS-EGN-S120M40A?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-EGN-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The key-release pin mechanism has been certified as part of the TUV evaluation, ensuring that the disconnect feature meets the same safety standards as the connection itself.\"}}, {\"@type\": \"Question\", \"name\": \"Is PFLS-EGN-S120M40A compatible with single-pole connectors from other manufacturers?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PowerFit connectors are designed to be compatible with major brands of single-pole power connector. IP67 dust-tight and waterproof protection is critical underground, the 35.5 kA short circuit rating provides safety margin in high-fault-current mining distribution, and the non-conductive housing eliminates accidental current paths. For PE circuits using Universal (all regions) color conventions, the green PFLS-EGN-S120M40A ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\"}}, {\"@type\": \"Question\", \"name\": \"How does the key-release mechanism work on PFLS-EGN-S120M40A?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The PFLS-EGN-S120M40A features the innovative PowerFit push-and-twist connection. To connect, align the connector and push while twisting until it locks. To disconnect, the patent key-release pin enables tool-free uncoupling. Simply press the release and twist to separate. If needed, a small slotted screwdriver can assist with the release. For cable termination, the process follows the same steps as other PowerFit line connectors: strip 33mm of cable jacket, apply the reduction sleeve, tighten set screws to 10.5 N\/m minimum, and secure the M40 cable gland. Uses the shorter cotter pin variant (vs the longer pin in Line Drain). The shorter pin accommodates the key-release mechanism. Never reuse cotter pins.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLS-EGN-S120M40A\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLS-EGN-S120M40A.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLS-EGN-S120M40A Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 400A \/ Inline Connector","offer_id":50208843759836,"sku":"PFLS-EGN-S120M40A","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLS-EGN-S120M40A-b.jpg?v=1777364453"},{"product_id":"pfpd-egn","title":"PFPD-EGN - PowerFit 400A Drain Panel Connector, Green (PE)","description":"\u003c!-- Combined Shopify product HTML for PFPD-EGN --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPD-EGN\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Panel Drain Connector (Green) - Earth | PFPD-EGN | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPD-EGN\" data-color=\"Green\"\u003e\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eLife-safety electrical grounding infrastructure protecting personnel and equipment from fault currents demands permanent earth\/ground connections that maintain absolute reliability across decades of operation without maintenance. The PowerFit 400A Panel Drain connector in green (Earth \/ PE universal) provides the enclosure-mount architecture for protective ground distribution in industrial facility main switchboards, renewable energy infrastructure, and data center grounding systems where equipment fault protection directly impacts personnel safety and regulatory compliance. Operating at 400A continuous current with silver-plated brass contacts rated for 500 mating cycles, this connector delivers the patent key-release pin for safe maintenance disconnection and plastic end cap protection, serving as the final electrical barrier between live power circuits and earth ground return paths.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003e400A continuous current rating at 120mm² cable; 660A at 240mm² cable for robust earth\/ground infrastructure\u003c\/li\u003e\n      \u003cli\u003eFemale contact design ensures secure mating with Panel Source grounding connectors in equipment cabinets\u003c\/li\u003e\n      \u003cli\u003eM12 threaded post with brass nut and spring washer provides reliable fastening for permanent ground connections\u003c\/li\u003e\n      \u003cli\u003eFour diameter 5.5mm fixing holes (42mm  x  42mm cut-out) accommodate standard grounding cabinet installations\u003c\/li\u003e\n      \u003cli\u003ePatent key-release pin enables safe disconnection of earth\/ground feeds during equipment maintenance without tools\u003c\/li\u003e\n      \u003cli\u003ePlastic end cap over female contact provides IP 2X finger protection - critical for life-safety grounding connections\u003c\/li\u003e\n      \u003cli\u003ePush-and-twist locking mechanism prevents vibration-induced separation of critical ground return paths\u003c\/li\u003e\n      \u003cli\u003eSilver-plated brass contact delivers 0.1 milliohms contact resistance, minimizing ground impedance and fault response time\u003c\/li\u003e\n      \u003cli\u003eNon-conductive UL94-V0 thermoplastic housing meets international electrical safety standards for grounding systems\u003c\/li\u003e\n      \u003cli\u003eIP67 rating while mated protects ground connections against moisture and dust ingress in harsh environments\u003c\/li\u003e\n      \u003cli\u003eMaximum nut torque: 12 to 14 N\/meter ensures secure mounting without damaging flange threads critical to grounding\u003c\/li\u003e\n      \u003cli\u003eGreen color coding provides universal earth\/protective ground (PE) identification across all major electrical standards globally\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eTÜV Rheinland certified (ID 1111303479) for global safety-critical grounding infrastructure\u003c\/li\u003e\n      \u003cli\u003eCE marking for international electrical safety equipment certification\u003c\/li\u003e\n      \u003cli\u003eRoHS and REACH compliant for environmental responsibility in safety-critical systems\u003c\/li\u003e\n      \u003cli\u003eUL94-V0 flame retardancy rating for grounding system safety\u003c\/li\u003e\n      \u003cli\u003eIP67 rating (dust-tight, temporary submersion protection) suitable for permanent ground installations\u003c\/li\u003e\n      \u003cli\u003e1000V AC \/ 1500V DC maximum operating voltage; 4500V AC dielectric test for high-energy fault conditions\u003c\/li\u003e\n      \u003cli\u003eShort circuit rating: Up to 35.5kA for rapid fault clearance in protective grounding circuits\u003c\/li\u003e\n      \u003cli\u003eInsulation resistance greater than 5000 megohms at 500V AC ensuring integrity of earth connection\u003c\/li\u003e\n      \u003cli\u003eWorking temperature range: 45 to 85 degrees Celsius - stable across environmental extremes for continuous operation\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eIndustrial facility main switchboard earth\/protective ground (PE) distribution infrastructure\u003c\/li\u003e\n      \u003cli\u003eData center grounding bus and redundant ground topology implementation\u003c\/li\u003e\n      \u003cli\u003eRenewable energy facility (wind, solar, hydro) protective ground return systems\u003c\/li\u003e\n      \u003cli\u003eHospital and medical facility life-safety grounding systems for patient and staff protection\u003c\/li\u003e\n      \u003cli\u003eTelecommunications tower and broadcast facility lightning protection grounding networks\u003c\/li\u003e\n      \u003cli\u003eOil and gas facility hazardous area electrical system grounding compliance\u003c\/li\u003e\n      \u003cli\u003eAviation and spacecraft ground support equipment electrical safety grounding\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe PowerFit 400A Panel Drain connector is compatible with major brands of single-pole power connector systems used in safety-critical grounding applications. Its M12 threaded post interface and push-and-twist mating mechanism follow standardized connection geometry across certified suppliers. Verify that your Panel Source grounding connector carries life-safety certifications and is rated for your specific ground current requirements and fault protection specifications. The green color housing provides universal protective ground (PE) identification recognized across all major electrical standards, ensuring unambiguous grounding circuit identification.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPD-EGN | PowerFit 400A Panel Drain, Earth (PE) Green (Universal protective earth\/ground)\",\n  \"description\": \"KUPO PowerFit 400A Panel Drain single-pole connector with green housing for Universal protective earth\/ground power distribution systems. Female Contact, M12 threaded post mount, IP67 rated when mated, silver-plated brass contacts, dual-rated 400A\/660A, 1000V AC \/ 1500V DC maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Panel-Mount Connectors \u003e PowerFit\",\n  \"sku\": \"PFPD-EGN\",\n  \"mpn\": \"PFPD-EGN\",\n  \"color\": \"Green\",\n  \"material\": \"Non-conductive thermoplastic housing; Brass silver-plated contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC \/ 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A continuous (120mm\u0026sup2; cable) \/ 660A continuous (240mm\u0026sup2; cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5 kiloamperes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Drain (Female Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-Twist Lock\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mounting Type\",\n      \"value\": \"Panel Mount with M12 Threaded Post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fixing Holes\",\n      \"value\": \"Four diameter 5.5mm holes; 42mm x 42mm cut-out dimension\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fastener Material\",\n      \"value\": \"Brass nut and spring washer\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Maximum Nut Torque\",\n      \"value\": \"12 to 14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated; IP 2X finger protection\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"TUV Certification ID\",\n      \"value\": \"1111303479\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV Rheinland, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Earth (PE) (Universal protective earth\/ground)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Green\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPD-EGN\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat role does PFPD-EGN serve in a power distribution enclosure?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-EGN is a KUPO PowerFit 400A panel drain connector with a green housing, designated for the Protective Earth (PE) conductor. Mounted permanently in enclosures and distribution boxes, it serves as the final destination in the PowerFit electric direction flow, where incoming power from Line Source connectors enters the downstream equipment. The four-point flange mount and M12 threaded post ensure vibration-resistant installation. It is commonly deployed in mining and tunneling applications. Underground mining and tunnel construction require power distribution in confined, humid, dusty environments where safety standards are especially stringent and equipment must withstand harsh mechanical treatment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat are the electrical specifications of PFPD-EGN for panel installations?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-EGN is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for PE circuits carrying continuous earth current.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does PFPD-EGN ensure proper earth conductor identification?\u003c\/h3\u003e\n    \u003cp\u003eGreen identifies the Protective Earth (PE) conductor across virtually every international standard: NEC, IEC, Australian, old UK, and Chinese GB. Some regions specify green\/yellow striped, but solid green is universally recognized as earth ground. Ground conductor integrity is the most critical safety element in any power distribution system. On the Panel Drain, the green color is visible on the connector face that protrudes from the enclosure panel. When multiple PowerFit connectors are mounted side by side in a distribution box, the color-coded faces create a clear visual map of the phase layout for incoming connections. A distinct green connector ensures the safety earth is never confused with a current-carrying phase or neutral conductor. This is non-negotiable for personnel safety and equipment protection.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications make PFPD-EGN suitable for permanent installation?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-EGN is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. For permanent installations, the IP 2X finger protection prevents accidental contact with live parts when the connector face is exposed, and the four-point flange mount exceeds mechanical retention requirements.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPD-EGN installed in a power distribution enclosure?\u003c\/h3\u003e\n    \u003cp\u003eInstalling PFPD-EGN requires a 42 x 42mm cutout in the enclosure panel. The connector mounts through four 5.5mm fixing holes on its flange, distributing clamping force evenly for vibration resistance. The M12 threaded post accepts the brass nut and washer, tightened to a maximum of 12 to 14 N\/m. IP 2X finger protection is built into the connector face, preventing accidental contact with live parts when no mating connector is inserted. A plastic end cap protects the contacts during storage and transport. The Panel Drain has a 55.0mm flange width and 72.2mm total depth, with a 37.0mm body diameter. The flange provides a generous mounting surface for secure enclosure attachment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat equipment and enclosures is PFPD-EGN designed to mount in?\u003c\/h3\u003e\n    \u003cp\u003ePowerFit connectors are designed to be compatible with major brands of single-pole power connector. IP67 dust-tight and waterproof protection is critical underground, the 35.5 kA short circuit rating provides safety margin in high-fault-current mining distribution, and the non-conductive housing eliminates accidental current paths. For PE circuits using Universal (all regions) color conventions, the green PFPD-EGN ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What role does PFPD-EGN serve in a power distribution enclosure?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-EGN is a KUPO PowerFit 400A panel drain connector with a green housing, designated for the Protective Earth (PE) conductor. Mounted permanently in enclosures and distribution boxes, it serves as the final destination in the PowerFit electric direction flow, where incoming power from Line Source connectors enters the downstream equipment. The four-point flange mount and M12 threaded post ensure vibration-resistant installation. It is commonly deployed in mining and tunneling applications. Underground mining and tunnel construction require power distribution in confined, humid, dusty environments where safety standards are especially stringent and equipment must withstand harsh mechanical treatment.\"}}, {\"@type\": \"Question\", \"name\": \"What are the electrical specifications of PFPD-EGN for panel installations?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-EGN is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for PE circuits carrying continuous earth current.\"}}, {\"@type\": \"Question\", \"name\": \"How does PFPD-EGN ensure proper earth conductor identification?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Green identifies the Protective Earth (PE) conductor across virtually every international standard: NEC, IEC, Australian, old UK, and Chinese GB. Some regions specify green\/yellow striped, but solid green is universally recognized as earth ground. Ground conductor integrity is the most critical safety element in any power distribution system. On the Panel Drain, the green color is visible on the connector face that protrudes from the enclosure panel. When multiple PowerFit connectors are mounted side by side in a distribution box, the color-coded faces create a clear visual map of the phase layout for incoming connections. A distinct green connector ensures the safety earth is never confused with a current-carrying phase or neutral conductor. This is non-negotiable for personnel safety and equipment protection.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications make PFPD-EGN suitable for permanent installation?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-EGN is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. For permanent installations, the IP 2X finger protection prevents accidental contact with live parts when the connector face is exposed, and the four-point flange mount exceeds mechanical retention requirements.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPD-EGN installed in a power distribution enclosure?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Installing PFPD-EGN requires a 42 x 42mm cutout in the enclosure panel. The connector mounts through four 5.5mm fixing holes on its flange, distributing clamping force evenly for vibration resistance. The M12 threaded post accepts the brass nut and washer, tightened to a maximum of 12 to 14 N\/m. IP 2X finger protection is built into the connector face, preventing accidental contact with live parts when no mating connector is inserted. A plastic end cap protects the contacts during storage and transport. The Panel Drain has a 55.0mm flange width and 72.2mm total depth, with a 37.0mm body diameter. The flange provides a generous mounting surface for secure enclosure attachment.\"}}, {\"@type\": \"Question\", \"name\": \"What equipment and enclosures is PFPD-EGN designed to mount in?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PowerFit connectors are designed to be compatible with major brands of single-pole power connector. IP67 dust-tight and waterproof protection is critical underground, the 35.5 kA short circuit rating provides safety margin in high-fault-current mining distribution, and the non-conductive housing eliminates accidental current paths. For PE circuits using Universal (all regions) color conventions, the green PFPD-EGN ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPD-EGN\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPD-EGN.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPD-EGN Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 400A \/ Panel Mount Receptacle","offer_id":50208844284124,"sku":"PFPD-EGN","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPD-EGN.jpg?v=1777364465"},{"product_id":"pfps-egn","title":"PFPS-EGN - PowerFit 400A Source Panel Connector, Green (PE)","description":"\u003c!-- Combined Shopify product HTML for PFPS-EGN --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPS-EGN\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Panel Source Connector (Green) | PFPS-EGN | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPS-EGN\" data-color=\"Green\"\u003e\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eProtective earth (PE) connections are the most safety-critical conductors in any power distribution system, requiring absolute reliability under fault conditions. The PowerFit 400A Panel Source in green provides a dedicated earth bonding inlet for equipment enclosures, generator frames, and portable power distribution systems. The 400A continuous rating ensures the earth path can safely carry prospective fault currents, while the silver-plated brass contact and push-and-twist mechanical lock prevent the earth connection from being inadvertently broken. The green housing is universally recognized across all international electrical standards as the protective earth conductor identification color.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003e400A continuous current capacity at 120mm squared cable; 660A continuous at 240mm squared cable for heavy-duty applications\u003c\/li\u003e\n      \u003cli\u003eMale contact design provides the power source pin for mating with Line Drain or Panel Drain connectors\u003c\/li\u003e\n      \u003cli\u003ePatent key-release pin with POM (Polyoxymethylene) cotter pin enables tool-free disconnection without risking contact damage\u003c\/li\u003e\n      \u003cli\u003eM12 threaded post with brass nut and spring washer for permanent, vibration-resistant panel installation\u003c\/li\u003e\n      \u003cli\u003eFour diameter 5.5mm fixing holes on flange (42mm x 42mm cut-out dimension) ensure secure mechanical mounting\u003c\/li\u003e\n      \u003cli\u003ePlastic end cap over male contact provides IP 2X finger protection against electric shock when unmated\u003c\/li\u003e\n      \u003cli\u003ePush-and-twist locking mechanism maintains positive mechanical engagement across 500 rated mating cycles\u003c\/li\u003e\n      \u003cli\u003eBrass contact with silver plating delivers 0.1 milliohms contact resistance for minimal voltage drop and heat generation\u003c\/li\u003e\n      \u003cli\u003eNon-conductive thermoplastic housing rated UL94-V0 flame retardant for safety-critical installations\u003c\/li\u003e\n      \u003cli\u003eIP67 rating while connected ensures protection against water and dust ingress in outdoor or washdown environments\u003c\/li\u003e\n      \u003cli\u003e1000V AC \/ 1500V DC maximum voltage rating with 4500V AC dielectric test voltage for substantial safety margins\u003c\/li\u003e\n      \u003cli\u003eMaximum nut torque: 12 to 14 N\/meter for proper fastening without over-tightening\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eTUV Rheinland certified (ID 1111303479) - Type Approved, Safety, Regular Production Surveillance\u003c\/li\u003e\n      \u003cli\u003eCE marked for European market compliance\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) compliant\u003c\/li\u003e\n      \u003cli\u003eREACH (Registration, Evaluation, Authorisation and Restriction of Chemicals) compliant\u003c\/li\u003e\n      \u003cli\u003eUL94-V0 flame retardancy classification for the housing material\u003c\/li\u003e\n      \u003cli\u003eIP67 environmental protection rating while mated (dust-tight, resistant to temporary submersion)\u003c\/li\u003e\n      \u003cli\u003eShort circuit capacity: Up to 35.5 kiloamperes\u003c\/li\u003e\n      \u003cli\u003eInsulation resistance: Greater than 5000 megohms at 500V AC\u003c\/li\u003e\n      \u003cli\u003eWorking temperature range: 45 to 85 degrees Celsius\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eEquipment grounding bus bars and protective earth bonding points in power distribution panels\u003c\/li\u003e\n      \u003cli\u003eGenerator frame grounding and portable power system earth connections\u003c\/li\u003e\n      \u003cli\u003eSafety ground inlets for metal-enclosed switchgear and motor control centers\u003c\/li\u003e\n      \u003cli\u003eTemporary power system grounding for construction sites and event installations\u003c\/li\u003e\n      \u003cli\u003eLightning protection and surge grounding panel connections\u003c\/li\u003e\n      \u003cli\u003eIndustrial facility equipment grounding conductors for personnel safety compliance\u003c\/li\u003e\n      \u003cli\u003eRedundant earth bonding paths for critical infrastructure and data center installations\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe PowerFit 400A Panel Source connector is compatible with major brands of single-pole power connector systems. Its M12 threaded post interface and push-and-twist mating mechanism with key-release pin ensure standardized connection geometry across certified suppliers. The male contact mates with PowerFit Line Drain and Panel Drain connectors. Verify mechanical and electrical specifications with your mating connector manufacturer to confirm impedance matching and safe operating parameters. Use the color-coded and mechanically keyed design as a visual safeguard to prevent cross-phase connection errors during installation or reconfiguration.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPS-EGN | PowerFit 400A Panel Source, Earth (PE) Green (Universal protective earth\/ground)\",\n  \"description\": \"KUPO PowerFit 400A Panel Source single-pole connector with green housing for Universal protective earth\/ground power distribution systems. Male Contact, M12 threaded post mount, patent key-release pin for safe disconnection, IP67 rated when mated, silver-plated brass contacts, dual-rated 400A\/660A, 1000V AC \/ 1500V DC maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Panel-Mount Connectors \u003e PowerFit\",\n  \"sku\": \"PFPS-EGN\",\n  \"mpn\": \"PFPS-EGN\",\n  \"color\": \"Green\",\n  \"material\": \"Non-conductive thermoplastic housing; Brass silver-plated contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC \/ 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A continuous (120mm\u0026sup2; cable) \/ 660A continuous (240mm\u0026sup2; cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5 kiloamperes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Source (Male Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-Twist with Key-Release Mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cotter Pin Material\",\n      \"value\": \"POM (Polyoxymethylene)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mounting Type\",\n      \"value\": \"Panel Mount with M12 Threaded Post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fixing Holes\",\n      \"value\": \"Four diameter 5.5mm holes; 42mm x 42mm cut-out dimension\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fastener Material\",\n      \"value\": \"Brass nut and spring washer\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Maximum Nut Torque\",\n      \"value\": \"12 to 14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated; IP 2X finger protection\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"TUV Certification ID\",\n      \"value\": \"1111303479\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV Rheinland, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Earth (PE) (Universal protective earth\/ground)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Green\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPS-EGN\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does PFPS-EGN combine panel mounting with disconnect convenience?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-EGN is a KUPO PowerFit 400A panel source connector with a green housing, designated for the Protective Earth (PE) conductor. Mounted permanently at generator outputs, main panels, and power supply enclosures, it is the origin point from which power flows outward through the PowerFit system. Despite being panel-mounted, it retains the key-release mechanism for convenient field disconnection. It is commonly deployed in mining and tunneling applications. Underground mining and tunnel construction require power distribution in confined, humid, dusty environments where safety standards are especially stringent and equipment must withstand harsh mechanical treatment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat electrical capacity does PFPS-EGN provide as a panel source connector?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-EGN is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for PE circuits carrying continuous earth current.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhy is the green earth connector PFPS-EGN critical for safety?\u003c\/h3\u003e\n    \u003cp\u003eGreen identifies the Protective Earth (PE) conductor across virtually every international standard: NEC, IEC, Australian, old UK, and Chinese GB. Some regions specify green\/yellow striped, but solid green is universally recognized as earth ground. Ground conductor integrity is the most critical safety element in any power distribution system. On the Panel Source, the green housing is visible on the connector face at the power origin point. Color coding at the source end of the distribution chain is especially important because phase assignment errors at the panel propagate through every downstream connection. A distinct green connector ensures the safety earth is never confused with a current-carrying phase or neutral conductor. This is non-negotiable for personnel safety and equipment protection.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety certifications does PFPS-EGN hold for distribution panel use?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-EGN is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. As the power origin point, the Panel Source undergoes the same TUV safety evaluation as the full PowerFit system, including the key-release mechanism and panel-mount retention.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat equipment and enclosures is PFPS-EGN designed to mount in?\u003c\/h3\u003e\n    \u003cp\u003ePowerFit connectors are designed to be compatible with major brands of single-pole power connector. IP67 dust-tight and waterproof protection is critical underground, the 35.5 kA short circuit rating provides safety margin in high-fault-current mining distribution, and the non-conductive housing eliminates accidental current paths. For PE circuits using Universal (all regions) color conventions, the green PFPS-EGN ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"How does PFPS-EGN combine panel mounting with disconnect convenience?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-EGN is a KUPO PowerFit 400A panel source connector with a green housing, designated for the Protective Earth (PE) conductor. Mounted permanently at generator outputs, main panels, and power supply enclosures, it is the origin point from which power flows outward through the PowerFit system. Despite being panel-mounted, it retains the key-release mechanism for convenient field disconnection. It is commonly deployed in mining and tunneling applications. Underground mining and tunnel construction require power distribution in confined, humid, dusty environments where safety standards are especially stringent and equipment must withstand harsh mechanical treatment.\"}}, {\"@type\": \"Question\", \"name\": \"What electrical capacity does PFPS-EGN provide as a panel source connector?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-EGN is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for PE circuits carrying continuous earth current.\"}}, {\"@type\": \"Question\", \"name\": \"Why is the green earth connector PFPS-EGN critical for safety?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Green identifies the Protective Earth (PE) conductor across virtually every international standard: NEC, IEC, Australian, old UK, and Chinese GB. Some regions specify green\/yellow striped, but solid green is universally recognized as earth ground. Ground conductor integrity is the most critical safety element in any power distribution system. On the Panel Source, the green housing is visible on the connector face at the power origin point. Color coding at the source end of the distribution chain is especially important because phase assignment errors at the panel propagate through every downstream connection. A distinct green connector ensures the safety earth is never confused with a current-carrying phase or neutral conductor. This is non-negotiable for personnel safety and equipment protection.\"}}, {\"@type\": \"Question\", \"name\": \"What safety certifications does PFPS-EGN hold for distribution panel use?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-EGN is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. As the power origin point, the Panel Source undergoes the same TUV safety evaluation as the full PowerFit system, including the key-release mechanism and panel-mount retention.\"}}, {\"@type\": \"Question\", \"name\": \"What equipment and enclosures is PFPS-EGN designed to mount in?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PowerFit connectors are designed to be compatible with major brands of single-pole power connector. IP67 dust-tight and waterproof protection is critical underground, the 35.5 kA short circuit rating provides safety margin in high-fault-current mining distribution, and the non-conductive housing eliminates accidental current paths. For PE circuits using Universal (all regions) color conventions, the green PFPS-EGN ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPS-EGN\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPS-EGN.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPS-EGN Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 400A \/ Panel Mount Receptacle","offer_id":50208844775644,"sku":"PFPS-EGN","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPS-EGN-b.jpg?v=1777364479"}],"url":"https:\/\/kupopower.com\/collections\/powerfit-400a-ground-earth-connectors.oembed","provider":"KUPO Power","version":"1.0","type":"link"}