{"title":"PowerFit 400A Phase B (L2)","description":"\u003c!-- KUPO Power - PowerFit 400A Phase B (L2) (TIER 2 - Mid-Tier Slice, Phase)\n     Shopify Collection Body HTML\n     Handle: powerfit-400a-phase-b-l2\n     URL: https:\/\/kupopower.com\/collections\/powerfit-400a-phase-b-l2 --\u003e\n\n\u003cp\u003ePowerFit 400A connectors keyed for Phase B (L2), the second live phase in a three-phase 400V European distribution system. IEC 60446 standard color: Black. The Phase B keying physically prevents accidental connection to a different phase position, ensuring each three-phase set lands in the correct sequence at every cable junction. This collection contains all PowerFit 400A SKUs configured for the L2 phase across all four form factors: Line Source, Line Drain, Panel Mount Source, and Panel Mount Drain.\u003c\/p\u003e\n\n\u003cp style=\"font-size:0.9rem; color:#666; margin-top:1rem;\"\u003eLooking for a different phase? Browse \u003ca href=\"https:\/\/kupopower.com\/collections\/powerfit-400a-phase-a-l1\"\u003ePhase A (L1)\u003c\/a\u003e · \u003ca href=\"https:\/\/kupopower.com\/collections\/powerfit-400a-phase-c-l3\"\u003ePhase C (L3)\u003c\/a\u003e · \u003ca href=\"https:\/\/kupopower.com\/collections\/powerfit-400a-neutral\"\u003eNeutral\u003c\/a\u003e · \u003ca href=\"https:\/\/kupopower.com\/collections\/powerfit-400a-ground-earth-connectors\"\u003eGround \/ Earth\u003c\/a\u003e · \u003ca href=\"https:\/\/kupopower.com\/collections\/powerfit-400a\"\u003eall PowerFit 400A\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"pfld-2bk","title":"PFLD-2BK-S120M40A - PowerFit 400A Drain Line Connector, Black (L2)","description":"\u003c!-- Combined Shopify product HTML for PFLD-2BK-S120M40A --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLD-2BK-S120M40A\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Line Drain Connector (Black) | PFLD-2BK-S120M40A | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLD-2BK-S120M40A\" data-color=\"Black\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLD-2BK-S120M40A is a 400A single-pole line drain connector engineered for mission-critical power distribution systems. This inline female connector incorporates dual-amperage capability - delivering 400 amperes continuous at 120 square millimeters or 660 amperes continuous at 240 square millimeters - making it the choice for industrial installations where load flexibility and long-term reliability matter. Rated to 1000 volts alternating current and 1500 volts direct current, this connector establishes a sealed, durable connection through a push-and-twist mating mechanism that eliminates fumbling and reduces connection errors in the field.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eDual-rated performance: 400A at 120mm² or 660A at 240mm² for flexible system design\u003c\/li\u003e\n\u003cli\u003eSilver-plated brass contacts ensure superior conductivity and corrosion resistance\u003c\/li\u003e\n\u003cli\u003eM40 by 1.5-millimeter cable gland with sealing bushings (22-millimeter and 33-millimeter inside diameter) accommodates standard industrial cables\u003c\/li\u003e\n\u003cli\u003ePush-and-twist connection - intuitive, field-proven assembly without specialized tools\u003c\/li\u003e\n\u003cli\u003eSilicone O-ring maintains IP67 rating when mated, protecting against dust and water ingress\u003c\/li\u003e\n\u003cli\u003eNon-conductive, flame-retardant thermoplastic housing meets UL94-V0 fire standards\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip improves handling and grip security during installation\u003c\/li\u003e\n\u003cli\u003eR120 reduction sleeve accommodates wire diameters up to 16.50 millimeters\u003c\/li\u003e\n\u003cli\u003eSet screw contact with 10.5 newton-meters minimum torque specification ensures vibration-proof assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV Rheinland certification (ID: 1111303479)\u003c\/li\u003e\n\u003cli\u003eCE marking\u003c\/li\u003e\n\u003cli\u003eRoHS compliance\u003c\/li\u003e\n\u003cli\u003eREACH compliance\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame class\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLD-2BK-S120M40A suits renewable energy installations, industrial motor drives, battery management systems, and heavy-duty power distribution cabinets where performance and component reliability are paramount. Its 500 mating cycles rating and sealed construction make it suitable for both fixed industrial environments and field applications demanding robust, repeatable connections.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector is compatible with major brands of single-pole power connectors, allowing system designers to integrate KUPO components into existing infrastructure with confidence. The push-and-twist connection standard aligns with industry practice, facilitating seamless interchangeability in field deployments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLD-2BK-S120M40A | PowerFit 400A Line Drain, L2 (Phase B) Black (IEC - European)\",\n  \"description\": \"KUPO PowerFit 400A Line Drain single-pole connector with black housing for IEC - European power distribution systems. Female Contact, M40 cable gland with sealing bushing, IP67 rated when mated, silver-plated brass contacts, dual-rated 400A\/660A, 1000V AC \/ 1500V DC maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLD-2BK-S120M40A\",\n  \"mpn\": \"PFLD-2BK-S120M40A\",\n  \"color\": \"Black\",\n  \"material\": \"Non-conductive thermoplastic housing; Brass silver-plated contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC \/ 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A continuous (120mm\u0026sup2; cable) \/ 660A continuous (240mm\u0026sup2; cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5 kiloamperes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Drain (Female Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-Twist Lock\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing (Inner Diameter: 22mm and 33mm)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Set Screw Torque\",\n      \"value\": \"10.5 N\/meter minimum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"TUV Certification ID\",\n      \"value\": \"1111303479\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV Rheinland, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 (Phase B) (IEC - European)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Black\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLD-2BK-S120M40A\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat makes PFLD-2BK-S120M40A different from a standard inline power connector?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-2BK-S120M40A is a KUPO PowerFit 400A line drain connector with a black housing, identifying Line 2 (L2) under Europe and UK (IEC 60446) conventions. As the drain side of an inline cable connection, it receives the mating source contact and provides a sealed, IP67-rated junction when coupled. The black housing enables instant visual identification of the L2 conductor across cable runs. It is commonly deployed in industrial manufacturing plant applications. Temporary power in manufacturing environments faces vibration from heavy machinery, exposure to oils and cutting fluids, and the need for high current capacity to feed welders, presses, and large motors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat are the electrical ratings and wire capacity of PFLD-2BK-S120M40A?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-2BK-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for L2 circuits carrying continuous phase current.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the black housing on PFLD-2BK-S120M40A represent under Europe and UK (IEC 60446) standards?\u003c\/h3\u003e\n    \u003cp\u003eUnder IEC 60446, black identifies Line 2 (L2). This is the second phase conductor in the European three-phase system of brown (L1), black (L2), grey (L3). For international crews, this is a critical distinction: the same black housing that means L1 in North America means L2 in Europe. On the Line Drain connector, the black housing is visible along the full 190mm body length, making L2 identification easy even when cables are bundled tightly. The ergonomic rubber grip section also carries the color, so technicians can identify the phase while handling the connector. Cross-convention errors between NEC-L1-black and IEC-L2-black are among the most common phase identification mistakes on international projects.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and safety ratings does PFLD-2BK-S120M40A carry?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-2BK-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The silicone O-ring seal contributes to the IP67 rating when mated, meaning the connection is fully protected against dust ingress and temporary immersion in water up to 1 meter for 30 minutes.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow do you assemble PFLD-2BK-S120M40A onto a power cable in the field?\u003c\/h3\u003e\n    \u003cp\u003eTo assemble PFLD-2BK-S120M40A, remove the M40 cable gland and extract the contact. Insert the contact into the insulator and align the cotter pin hole. Strip back the cable jacket by approximately 33mm, then slide the R120 reduction sleeve (brass with silver plating, up to 16.50mm wire diameter) over the exposed conductor. Hammer the cotter pin in from its chamfered side for proper seating. Slide the cable with reduction sleeve into the contact, then tighten both set screws using a 5mm hex key to a minimum of 10.5 N\/m. Finally, thread the cable gland back on. The M40 gland includes two rubber bushings (inner diameter 23mm and 33mm) for flexibility with different cable sizes. At 190mm total length with a 32.5mm body diameter, the Line Drain is the longest connector in the PowerFit family, providing ample space for cable management and a secure grip surface.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs PFLD-2BK-S120M40A compatible with single-pole connectors from other manufacturers?\u003c\/h3\u003e\n    \u003cp\u003ePowerFit connectors are designed to be compatible with major brands of single-pole power connector. The 400A continuous rating (660A with 240mm2 cable) handles industrial loads, the flame-retardant UL94-V0 housing resists chemical exposure, and the push-and-twist lock prevents vibration-induced disconnection. For L2 circuits using Europe and UK (IEC 60446) color conventions, the black PFLD-2BK-S120M40A ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What makes PFLD-2BK-S120M40A different from a standard inline power connector?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-2BK-S120M40A is a KUPO PowerFit 400A line drain connector with a black housing, identifying Line 2 (L2) under Europe and UK (IEC 60446) conventions. As the drain side of an inline cable connection, it receives the mating source contact and provides a sealed, IP67-rated junction when coupled. The black housing enables instant visual identification of the L2 conductor across cable runs. It is commonly deployed in industrial manufacturing plant applications. Temporary power in manufacturing environments faces vibration from heavy machinery, exposure to oils and cutting fluids, and the need for high current capacity to feed welders, presses, and large motors.\"}}, {\"@type\": \"Question\", \"name\": \"What are the electrical ratings and wire capacity of PFLD-2BK-S120M40A?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-2BK-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for L2 circuits carrying continuous phase current.\"}}, {\"@type\": \"Question\", \"name\": \"What does the black housing on PFLD-2BK-S120M40A represent under Europe and UK (IEC 60446) standards?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Under IEC 60446, black identifies Line 2 (L2). This is the second phase conductor in the European three-phase system of brown (L1), black (L2), grey (L3). For international crews, this is a critical distinction: the same black housing that means L1 in North America means L2 in Europe. On the Line Drain connector, the black housing is visible along the full 190mm body length, making L2 identification easy even when cables are bundled tightly. The ergonomic rubber grip section also carries the color, so technicians can identify the phase while handling the connector. Cross-convention errors between NEC-L1-black and IEC-L2-black are among the most common phase identification mistakes on international projects.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and safety ratings does PFLD-2BK-S120M40A carry?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-2BK-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The silicone O-ring seal contributes to the IP67 rating when mated, meaning the connection is fully protected against dust ingress and temporary immersion in water up to 1 meter for 30 minutes.\"}}, {\"@type\": \"Question\", \"name\": \"How do you assemble PFLD-2BK-S120M40A onto a power cable in the field?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"To assemble PFLD-2BK-S120M40A, remove the M40 cable gland and extract the contact. Insert the contact into the insulator and align the cotter pin hole. Strip back the cable jacket by approximately 33mm, then slide the R120 reduction sleeve (brass with silver plating, up to 16.50mm wire diameter) over the exposed conductor. Hammer the cotter pin in from its chamfered side for proper seating. Slide the cable with reduction sleeve into the contact, then tighten both set screws using a 5mm hex key to a minimum of 10.5 N\/m. Finally, thread the cable gland back on. The M40 gland includes two rubber bushings (inner diameter 23mm and 33mm) for flexibility with different cable sizes. At 190mm total length with a 32.5mm body diameter, the Line Drain is the longest connector in the PowerFit family, providing ample space for cable management and a secure grip surface.\"}}, {\"@type\": \"Question\", \"name\": \"Is PFLD-2BK-S120M40A compatible with single-pole connectors from other manufacturers?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PowerFit connectors are designed to be compatible with major brands of single-pole power connector. The 400A continuous rating (660A with 240mm2 cable) handles industrial loads, the flame-retardant UL94-V0 housing resists chemical exposure, and the push-and-twist lock prevents vibration-induced disconnection. For L2 circuits using Europe and UK (IEC 60446) color conventions, the black PFLD-2BK-S120M40A ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLD-2BK-S120M40A\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLD-2BK-S120M40A.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLD-2BK-S120M40A Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 400A \/ Inline Connector","offer_id":50208842612956,"sku":"PFLD-2BK-S120M40A","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLD-2BK-S120M40A.jpg?v=1777364428"},{"product_id":"pfld-2r","title":"PFLD-2R-S120M40A - PowerFit 400A Drain Line Connector, Red (L2)","description":"\u003c!-- Combined Shopify product HTML for PFLD-2R-S120M40A --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLD-2R-S120M40A\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Line Drain Connector (Red) | PFLD-2R-S120M40A | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLD-2R-S120M40A\" data-color=\"Red\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eSafety and reliability converge in the PFLD-2R-S120M40A, a 400A single-pole line drain connector designed to protect critical power distribution systems. This inline female connector delivers sealed, secure connections through its push-and-twist mechanism while maintaining IP67-rated protection against environmental contaminants. The non-conductive, flame-retardant housing meets UL94-V0 standards, providing essential fire safety in installations where personnel proximity and equipment density demand superior performance. Operating across a 1000 volt alternating current or 1500 volt direct current envelope, this connector supports both standard 400-ampere and heavy-duty 660-ampere configurations depending on cable cross-section.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eIP67-rated silicone O-ring sealing prevents dust and moisture ingress when mated\u003c\/li\u003e\n\u003cli\u003eFlame-retardant housing (UL94-V0) provides critical fire safety protection\u003c\/li\u003e\n\u003cli\u003eNon-conductive thermoplastic body eliminates leakage current pathways\u003c\/li\u003e\n\u003cli\u003eSilver-plated brass contacts deliver measurable conductivity: contact resistance rated at 0.1 milliohms\u003c\/li\u003e\n\u003cli\u003eConfiguration flexibility: 400A continuous at 120mm² or 660A continuous at 240mm²\u003c\/li\u003e\n\u003cli\u003eM40 by 1.5-millimeter cable gland with dual sealing bushings (22-millimeter and 33-millimeter inside diameter)\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip increases safety during mating operations and reduces connection errors\u003c\/li\u003e\n\u003cli\u003eSet screw contact requires 10.5 newton-meters minimum torque to prevent loosening under vibration\u003c\/li\u003e\n\u003cli\u003ePush-and-twist assembly - no special tools or fixtures needed in the field\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV Rheinland certification (ID: 1111303479) - independent third-party validation\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance ensures material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating provides fire safety assurance\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLD-2R-S120M40A excels in grid-tied solar systems, energy storage installations, industrial switchgear, and backup power systems where safety certification and environmental sealing are non-negotiable. The 500 mating cycle rating supports installation and maintenance workflows, while the sealed design prevents costly corrosion and equipment shutdown in humid or outdoor environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector is compatible with major brands of single-pole power connectors, enabling system integrators to specify KUPO connectors across mixed-manufacturer architectures. The push-and-twist interface conforms to established industry standards, ensuring reliable mating with existing inventory and field-proven components.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLD-2R-S120M40A | PowerFit 400A Line Drain, L2 (Phase B) Red (NEC - North American)\",\n  \"description\": \"KUPO PowerFit 400A Line Drain single-pole connector with red housing for NEC - North American power distribution systems. Female Contact, M40 cable gland with sealing bushing, IP67 rated when mated, silver-plated brass contacts, dual-rated 400A\/660A, 1000V AC \/ 1500V DC maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLD-2R-S120M40A\",\n  \"mpn\": \"PFLD-2R-S120M40A\",\n  \"color\": \"Red\",\n  \"material\": \"Non-conductive thermoplastic housing; Brass silver-plated contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC \/ 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A continuous (120mm\u0026sup2; cable) \/ 660A continuous (240mm\u0026sup2; cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5 kiloamperes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Drain (Female Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-Twist Lock\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing (Inner Diameter: 22mm and 33mm)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Set Screw Torque\",\n      \"value\": \"10.5 N\/meter minimum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"TUV Certification ID\",\n      \"value\": \"1111303479\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV Rheinland, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 (Phase B) (NEC - North American)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Red\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLD-2R-S120M40A\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLD-2R-S120M40A and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-2R-S120M40A is a KUPO PowerFit 400A line drain connector with a red housing, identifying Line 2 (L2) under North America (NEC) conventions. As the drain side of an inline cable connection, it receives the mating source contact and provides a sealed, IP67-rated junction when coupled. The red housing enables instant visual identification of the L2 conductor across cable runs. It is commonly deployed in construction site applications. Construction power distribution deals with dust, debris, rain, rough handling by crews, and the constant repositioning of equipment as the site evolves.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current can PFLD-2R-S120M40A safely handle in continuous operation?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-2R-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The insulation resistance exceeds 5000 megaohms at 500V AC, and the test voltage rating of 4500V AC provides substantial safety margin. The short circuit rating of up to 35.5 kiloamperes means the connector can withstand fault conditions without catastrophic failure.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the red housing on PFLD-2R-S120M40A represent under North America (NEC) standards?\u003c\/h3\u003e\n    \u003cp\u003eRed marks Line 2 (L2) under North American NEC conventions. In a standard three-phase system, the color sequence is black (L1), red (L2), blue (L3). Red L2 is one of the most commonly ordered phase variants for US and Canadian power distribution, appearing in virtually every multi-phase temporary power installation. On the Line Drain connector, the red housing is visible along the full 190mm body length, making L2 identification easy even when cables are bundled tightly. The ergonomic rubber grip section also carries the color, so technicians can identify the phase while handling the connector. Red is one of the most visually distinctive colors on a busy event site, helping crews quickly trace the second phase conductor even from a distance.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLD-2R-S120M40A certified for professional use?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-2R-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The silicone O-ring seal contributes to the IP67 rating when mated, meaning the connection is fully protected against dust ingress and temporary immersion in water up to 1 meter for 30 minutes.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eCan PFLD-2R-S120M40A be integrated into an existing power distribution system?\u003c\/h3\u003e\n    \u003cp\u003ePowerFit connectors are designed to be compatible with major brands of single-pole power connector. The high-impact thermoplastic housing absorbs punishment, the IP67 seal protects against dust ingress (the '6' in IP67 means dust-tight), and the M40 cable gland secures cables against pull-out. For L2 circuits using North America (NEC) color conventions, the red PFLD-2R-S120M40A ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLD-2R-S120M40A and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-2R-S120M40A is a KUPO PowerFit 400A line drain connector with a red housing, identifying Line 2 (L2) under North America (NEC) conventions. As the drain side of an inline cable connection, it receives the mating source contact and provides a sealed, IP67-rated junction when coupled. The red housing enables instant visual identification of the L2 conductor across cable runs. It is commonly deployed in construction site applications. Construction power distribution deals with dust, debris, rain, rough handling by crews, and the constant repositioning of equipment as the site evolves.\"}}, {\"@type\": \"Question\", \"name\": \"How much current can PFLD-2R-S120M40A safely handle in continuous operation?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-2R-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The insulation resistance exceeds 5000 megaohms at 500V AC, and the test voltage rating of 4500V AC provides substantial safety margin. The short circuit rating of up to 35.5 kiloamperes means the connector can withstand fault conditions without catastrophic failure.\"}}, {\"@type\": \"Question\", \"name\": \"What does the red housing on PFLD-2R-S120M40A represent under North America (NEC) standards?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Red marks Line 2 (L2) under North American NEC conventions. In a standard three-phase system, the color sequence is black (L1), red (L2), blue (L3). Red L2 is one of the most commonly ordered phase variants for US and Canadian power distribution, appearing in virtually every multi-phase temporary power installation. On the Line Drain connector, the red housing is visible along the full 190mm body length, making L2 identification easy even when cables are bundled tightly. The ergonomic rubber grip section also carries the color, so technicians can identify the phase while handling the connector. Red is one of the most visually distinctive colors on a busy event site, helping crews quickly trace the second phase conductor even from a distance.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLD-2R-S120M40A certified for professional use?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-2R-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The silicone O-ring seal contributes to the IP67 rating when mated, meaning the connection is fully protected against dust ingress and temporary immersion in water up to 1 meter for 30 minutes.\"}}, {\"@type\": \"Question\", \"name\": \"Can PFLD-2R-S120M40A be integrated into an existing power distribution system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PowerFit connectors are designed to be compatible with major brands of single-pole power connector. The high-impact thermoplastic housing absorbs punishment, the IP67 seal protects against dust ingress (the '6' in IP67 means dust-tight), and the M40 cable gland secures cables against pull-out. For L2 circuits using North America (NEC) color conventions, the red PFLD-2R-S120M40A ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLD-2R-S120M40A\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLD-2R-S120M40A.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLD-2R-S120M40A Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 400A \/ Inline Connector","offer_id":50208842678492,"sku":"PFLD-2R-S120M40A","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLD-2R-S120M40A.jpg?v=1777364429"},{"product_id":"pfld-2w","title":"PFLD-2W-S120M40A - PowerFit 400A Drain Line Connector, White (L2)","description":"\u003c!-- Combined Shopify product HTML for PFLD-2W-S120M40A --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLD-2W-S120M40A\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Line Drain Connector (White) | PFLD-2W-S120M40A | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLD-2W-S120M40A\" data-color=\"White\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eBuilt for field deployment, the PFLD-2W-S120M40A is a 400A single-pole line drain connector that combines rugged construction with straightforward installation. This inline female connector bridges demanding environments with an ergonomic rubber grip and the M40 by 1.5-millimeter cable gland that accepts cables up to 33-millimeter inside diameter through dual sealing bushings. The push-and-twist connection mechanism requires no specialized equipment - a significant advantage when rapid assembly matters and downtime costs money. Supporting both standard 400-ampere and elevated 660-ampere ratings depending on cable gauge, this connector adapts to diverse system configurations while maintaining sealed IP67 performance and compliance with international safety standards.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eErgonomic rubber grip improves tactile control and reduces fatigue during repeated mating operations\u003c\/li\u003e\n\u003cli\u003eM40 by 1.5-millimeter cable gland with sealing bushings (22-millimeter and 33-millimeter inside diameter) accommodates most standard industrial cable sizes\u003c\/li\u003e\n\u003cli\u003ePush-and-twist assembly - fast field installation without torque wrenches or alignment fixtures\u003c\/li\u003e\n\u003cli\u003eSilver-plated brass contacts deliver 0.1 milliohm contact resistance for efficient power transfer\u003c\/li\u003e\n\u003cli\u003eDual amperage rating: 400A continuous at 120mm² or 660A continuous at 240mm²\u003c\/li\u003e\n\u003cli\u003eIP67 sealed design with silicone O-ring maintains environmental protection when mated\u003c\/li\u003e\n\u003cli\u003eDurable non-conductive thermoplastic housing resists mechanical stress and environmental degradation\u003c\/li\u003e\n\u003cli\u003eR120 reduction sleeve accommodates wire diameters up to 16.50 millimeters\u003c\/li\u003e\n\u003cli\u003eSet screw contact rated to 10.5 newton-meters ensures stable, vibration-resistant assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV Rheinland certification (ID: 1111303479)\u003c\/li\u003e\n\u003cli\u003eCE marking\u003c\/li\u003e\n\u003cli\u003eRoHS compliance\u003c\/li\u003e\n\u003cli\u003eREACH compliance\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame class rating\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLD-2W-S120M40A performs reliably in Australian and regional renewable energy projects, distributed solar installations, microgrid systems, and portable power configurations where field technicians must work efficiently with standard cable glands and hand tools. The 500 mating cycle rating supports commissioning, maintenance, and system expansion without premature wear, while the sealed design protects investments in remote or exposed locations.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector is compatible with major brands of single-pole power connectors, enabling straightforward component sourcing and field interchangeability. The push-and-twist connection standard aligns with industry norms, allowing technicians trained on competing systems to assemble KUPO connectors without retraining or specialized equipment procurement.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLD-2W-S120M40A | PowerFit 400A Line Drain, L2 (Phase B) White (Australian)\",\n  \"description\": \"KUPO PowerFit 400A Line Drain single-pole connector with white housing for Australian power distribution systems. Female Contact, M40 cable gland with sealing bushing, IP67 rated when mated, silver-plated brass contacts, dual-rated 400A\/660A, 1000V AC \/ 1500V DC maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLD-2W-S120M40A\",\n  \"mpn\": \"PFLD-2W-S120M40A\",\n  \"color\": \"White\",\n  \"material\": \"Non-conductive thermoplastic housing; Brass silver-plated contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC \/ 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A continuous (120mm\u0026sup2; cable) \/ 660A continuous (240mm\u0026sup2; cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5 kiloamperes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Drain (Female Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-Twist Lock\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing (Inner Diameter: 22mm and 33mm)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Set Screw Torque\",\n      \"value\": \"10.5 N\/meter minimum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"TUV Certification ID\",\n      \"value\": \"1111303479\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV Rheinland, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 (Phase B) (Australian)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"White\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLD-2W-S120M40A\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat kind of connector is PFLD-2W-S120M40A and where does it fit in the power chain?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-2W-S120M40A is a KUPO PowerFit 400A line drain connector with a white housing, identifying Line 2 (L2) under Australia conventions. As the drain side of an inline cable connection, it receives the mating source contact and provides a sealed, IP67-rated junction when coupled. The white housing enables instant visual identification of the L2 conductor across cable runs. It is commonly deployed in marine and shipyard applications. Shipyard and dockside power connections face salt spray, high humidity, and the corrosive marine environment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat voltage and amperage is PFLD-2W-S120M40A rated for?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-2W-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The M40 cable gland accommodates cables through two included rubber bushings (inner diameter 23mm and 33mm), and the R120 reduction sleeve (brass with silver plating) handles conductor diameters up to 16.50mm. Set screws require a minimum torque of 10.5 N\/m for reliable termination.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the white housing on PFLD-2W-S120M40A represent under Australia standards?\u003c\/h3\u003e\n    \u003cp\u003eWhite as L2 follows Australian wiring conventions, where the three-phase set is red (L1), white (L2), blue (L3). This variant specifically serves Australian, New Zealand, and related Asia-Pacific markets. On the Line Drain connector, the white housing is visible along the full 190mm body length, making L2 identification easy even when cables are bundled tightly. The ergonomic rubber grip section also carries the color, so technicians can identify the phase while handling the connector. The stark visual contrast between white L2 and the darker L1\/L3 conductors makes phase tracing straightforward in Australian installations.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety standards govern the design and manufacture of PFLD-2W-S120M40A?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-2W-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The silicone O-ring seal contributes to the IP67 rating when mated, meaning the connection is fully protected against dust ingress and temporary immersion in water up to 1 meter for 30 minutes.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat makes PFLD-2W-S120M40A practical for field assembly during setup?\u003c\/h3\u003e\n    \u003cp\u003eTo assemble PFLD-2W-S120M40A, remove the M40 cable gland and extract the contact. Insert the contact into the insulator and align the cotter pin hole. Strip back the cable jacket by approximately 33mm, then slide the R120 reduction sleeve (brass with silver plating, up to 16.50mm wire diameter) over the exposed conductor. Hammer the cotter pin in from its chamfered side for proper seating. Slide the cable with reduction sleeve into the contact, then tighten both set screws using a 5mm hex key to a minimum of 10.5 N\/m. Finally, thread the cable gland back on. The M40 gland includes two rubber bushings (inner diameter 23mm and 33mm) for flexibility with different cable sizes. At 190mm total length with a 32.5mm body diameter, the Line Drain is the longest connector in the PowerFit family, providing ample space for cable management and a secure grip surface.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat advantages does PFLD-2W-S120M40A offer over conventional CAM-type connectors?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-2W-S120M40A offers several meaningful improvements over conventional single-pole power connectors: the 1000V AC \/ 1500V DC voltage rating exceeds the typical 600V maximum of traditional alternatives; silver-plated brass contacts deliver lower contact resistance (0.1 milliohms) than plain brass; the integrated M40 cable gland with sealing bushing provides cable strain relief and environmental protection in a single assembly; IP67 protection when mated provides dust-tight and waterproof sealing that most single-pole connectors lack. These features, combined with TUV Rheinland certification and the phase-encoded white housing for L2 identification, make PowerFit a generation ahead of traditional designs.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What kind of connector is PFLD-2W-S120M40A and where does it fit in the power chain?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-2W-S120M40A is a KUPO PowerFit 400A line drain connector with a white housing, identifying Line 2 (L2) under Australia conventions. As the drain side of an inline cable connection, it receives the mating source contact and provides a sealed, IP67-rated junction when coupled. The white housing enables instant visual identification of the L2 conductor across cable runs. It is commonly deployed in marine and shipyard applications. Shipyard and dockside power connections face salt spray, high humidity, and the corrosive marine environment.\"}}, {\"@type\": \"Question\", \"name\": \"What voltage and amperage is PFLD-2W-S120M40A rated for?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-2W-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The M40 cable gland accommodates cables through two included rubber bushings (inner diameter 23mm and 33mm), and the R120 reduction sleeve (brass with silver plating) handles conductor diameters up to 16.50mm. Set screws require a minimum torque of 10.5 N\/m for reliable termination.\"}}, {\"@type\": \"Question\", \"name\": \"What does the white housing on PFLD-2W-S120M40A represent under Australia standards?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"White as L2 follows Australian wiring conventions, where the three-phase set is red (L1), white (L2), blue (L3). This variant specifically serves Australian, New Zealand, and related Asia-Pacific markets. On the Line Drain connector, the white housing is visible along the full 190mm body length, making L2 identification easy even when cables are bundled tightly. The ergonomic rubber grip section also carries the color, so technicians can identify the phase while handling the connector. The stark visual contrast between white L2 and the darker L1\/L3 conductors makes phase tracing straightforward in Australian installations.\"}}, {\"@type\": \"Question\", \"name\": \"What safety standards govern the design and manufacture of PFLD-2W-S120M40A?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-2W-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The silicone O-ring seal contributes to the IP67 rating when mated, meaning the connection is fully protected against dust ingress and temporary immersion in water up to 1 meter for 30 minutes.\"}}, {\"@type\": \"Question\", \"name\": \"What makes PFLD-2W-S120M40A practical for field assembly during setup?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"To assemble PFLD-2W-S120M40A, remove the M40 cable gland and extract the contact. Insert the contact into the insulator and align the cotter pin hole. Strip back the cable jacket by approximately 33mm, then slide the R120 reduction sleeve (brass with silver plating, up to 16.50mm wire diameter) over the exposed conductor. Hammer the cotter pin in from its chamfered side for proper seating. Slide the cable with reduction sleeve into the contact, then tighten both set screws using a 5mm hex key to a minimum of 10.5 N\/m. Finally, thread the cable gland back on. The M40 gland includes two rubber bushings (inner diameter 23mm and 33mm) for flexibility with different cable sizes. At 190mm total length with a 32.5mm body diameter, the Line Drain is the longest connector in the PowerFit family, providing ample space for cable management and a secure grip surface.\"}}, {\"@type\": \"Question\", \"name\": \"What advantages does PFLD-2W-S120M40A offer over conventional CAM-type connectors?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-2W-S120M40A offers several meaningful improvements over conventional single-pole power connectors: the 1000V AC \/ 1500V DC voltage rating exceeds the typical 600V maximum of traditional alternatives; silver-plated brass contacts deliver lower contact resistance (0.1 milliohms) than plain brass; the integrated M40 cable gland with sealing bushing provides cable strain relief and environmental protection in a single assembly; IP67 protection when mated provides dust-tight and waterproof sealing that most single-pole connectors lack. These features, combined with TUV Rheinland certification and the phase-encoded white housing for L2 identification, make PowerFit a generation ahead of traditional designs.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLD-2W-S120M40A\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLD-2W-S120M40A.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLD-2W-S120M40A Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 400A \/ Inline Connector","offer_id":50208842711260,"sku":"PFLD-2W-S120M40A","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLD-2W-S120M40A-b.jpg?v=1777364430"},{"product_id":"pfld-2y","title":"PFLD-2Y-S120M40A - PowerFit 400A Drain Line Connector, Yellow (L2)","description":"\u003c!-- Combined Shopify product HTML for PFLD-2Y-S120M40A --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLD-2Y-S120M40A\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Line Drain Connector (Yellow) | PFLD-2Y-S120M40A | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLD-2Y-S120M40A\" data-color=\"Yellow\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PowerFit 400A Line Drain connector in yellow delivers rugged, reliable performance in harsh outdoor and industrial environments. Built to IP67 specifications and UL94-V0 flame-resistant standards, this push-and-twist female contact connector handles up to 400 amperes continuously while maintaining full ingress protection even in wet, dusty, and corrosive conditions. Yellow coding identifies this connector as Line 2 phase under the UK older BS 7671 convention, ensuring correct phase recognition in legacy UK installations and mixed-standard multi-region deployments. The non-conductive thermoplastic housing with high impact resistance protects against mechanical shock and chemical exposure, while the silver-plated brass contacts guarantee stable long-term conductivity under demanding environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP67 Sealed:\u003c\/strong\u003e Complete environmental protection when mated - water, dust, and debris cannot compromise the electrical connection even in continuous outdoor use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL94-V0 Flame Resistance:\u003c\/strong\u003e Housing material meets the strictest flammability standard, essential for safety-critical installations and regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePush-and-Twist Connection:\u003c\/strong\u003e Intuitive connection mechanism with secure mating; the patent key-release pin on source connectors enables single-handed disconnection without tools.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSilver-Plated Brass Contacts:\u003c\/strong\u003e Superior corrosion resistance compared to plain brass; maintains contact resistance at 0.1 milliohms even under salt spray, humidity, and thermal cycling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Impact-Resistant Thermoplastic:\u003c\/strong\u003e Non-conductive housing absorbs mechanical shock while resisting UV degradation, chemical attack, and extreme temperature fluctuation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNylon \u0026amp; Rubber Cable Gland:\u003c\/strong\u003e Ergonomic M40 x 1.5 gland with dual-size bushing (22mm and 33mm inner diameter) secures cables from 19 - 28mm diameter; rubber grip ensures safe handling in wet gloves.\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV Rheinland Certified (ID 1111303479) - Type Approved, Safety, Regular Production Surveillance\u003c\/li\u003e\n\u003cli\u003eCE marked for European market\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eREACH compliant\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame-resistance rating (housing material)\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003e\n        The PowerFit 400A Line Drain connector is compatible with major brands of single-pole power connector. The push-and-twist mechanism with patent key-release pin ensures reliable mating across generations of equipment and installations. Typical applications include renewable energy systems (solar and wind), industrial power distribution, heavy equipment charging infrastructure, mining operations, and harsh-environment industrial sites where outdoor durability and high current capacity are essential.\n    \u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eThree-phase power distribution systems requiring dedicated L2 inline connections\u003c\/li\u003e\n      \u003cli\u003eEntertainment industry dimmer and lighting power distribution feeder runs\u003c\/li\u003e\n      \u003cli\u003eIndustrial manufacturing equipment with balanced three-phase power requirements\u003c\/li\u003e\n      \u003cli\u003eRenewable energy installations including solar inverter and battery storage connections\u003c\/li\u003e\n      \u003cli\u003eConstruction site temporary power distribution for heavy equipment\u003c\/li\u003e\n      \u003cli\u003eMining and heavy industry power distribution in demanding environments\u003c\/li\u003e\n      \u003cli\u003eFestival and outdoor event infrastructure with weather-exposed cable runs\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLD-2Y-S120M40A | PowerFit 400A Line Drain, L2 (Phase B) Yellow (UK (Old Standard))\",\n  \"description\": \"KUPO PowerFit 400A Line Drain single-pole connector with yellow housing for UK (Old Standard) power distribution systems. Female Contact, M40 cable gland with sealing bushing, IP67 rated when mated, silver-plated brass contacts, dual-rated 400A\/660A, 1000V AC \/ 1500V DC maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLD-2Y-S120M40A\",\n  \"mpn\": \"PFLD-2Y-S120M40A\",\n  \"color\": \"Yellow\",\n  \"material\": \"Non-conductive thermoplastic housing; Brass silver-plated contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC \/ 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A continuous (120mm\u0026sup2; cable) \/ 660A continuous (240mm\u0026sup2; cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5 kiloamperes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Drain (Female Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-Twist Lock\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing (Inner Diameter: 22mm and 33mm)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Set Screw Torque\",\n      \"value\": \"10.5 N\/meter minimum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"TUV Certification ID\",\n      \"value\": \"1111303479\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV Rheinland, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 (Phase B) (UK (Old Standard))\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Yellow\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLD-2Y-S120M40A\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWho needs PFLD-2Y-S120M40A and what problem does it solve?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-2Y-S120M40A is a KUPO PowerFit 400A line drain connector with a yellow housing, identifying Line 2 (L2) under UK (Old, pre-2004) conventions. As the drain side of an inline cable connection, it receives the mating source contact and provides a sealed, IP67-rated junction when coupled. The yellow housing enables instant visual identification of the L2 conductor across cable runs. It is commonly deployed in data center maintenance applications. During data center expansion or maintenance windows, temporary power must be distributed with absolute reliability.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat are the electrical ratings and wire capacity of PFLD-2Y-S120M40A?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-2Y-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for L2 circuits carrying continuous phase current.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the yellow housing on PFLD-2Y-S120M40A represent under UK (Old, pre-2004) standards?\u003c\/h3\u003e\n    \u003cp\u003eYellow identifies L2 under the legacy UK wiring color code (red\/yellow\/blue for L1\/L2\/L3) used before the 2004 harmonization to IEC standards. Legacy UK installations, some Commonwealth countries, and specialty applications still use this color scheme. On the Line Drain connector, the yellow housing is visible along the full 190mm body length, making L2 identification easy even when cables are bundled tightly. The ergonomic rubber grip section also carries the color, so technicians can identify the phase while handling the connector. When maintaining or extending pre-2004 UK installations, matching the existing yellow L2 convention prevents confusion between old and new color systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and safety ratings does PFLD-2Y-S120M40A carry?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-2Y-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The silicone O-ring seal contributes to the IP67 rating when mated, meaning the connection is fully protected against dust ingress and temporary immersion in water up to 1 meter for 30 minutes.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs PFLD-2Y-S120M40A compatible with single-pole connectors from other manufacturers?\u003c\/h3\u003e\n    \u003cp\u003ePowerFit connectors are designed to be compatible with major brands of single-pole power connector. The 0.1 milliohm contact resistance minimizes heat generation at connection points, the 500-cycle mating rating supports repeated connect\/disconnect during maintenance, and the 1000V AC \/ 1500V DC rating provides margin for high-voltage DC distribution architectures. For L2 circuits using UK (Old, pre-2004) color conventions, the yellow PFLD-2Y-S120M40A ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow do you assemble PFLD-2Y-S120M40A onto a power cable in the field?\u003c\/h3\u003e\n    \u003cp\u003eTo assemble PFLD-2Y-S120M40A, remove the M40 cable gland and extract the contact. Insert the contact into the insulator and align the cotter pin hole. Strip back the cable jacket by approximately 33mm, then slide the R120 reduction sleeve (brass with silver plating, up to 16.50mm wire diameter) over the exposed conductor. Hammer the cotter pin in from its chamfered side for proper seating. Slide the cable with reduction sleeve into the contact, then tighten both set screws using a 5mm hex key to a minimum of 10.5 N\/m. Finally, thread the cable gland back on. The M40 gland includes two rubber bushings (inner diameter 23mm and 33mm) for flexibility with different cable sizes. At 190mm total length with a 32.5mm body diameter, the Line Drain is the longest connector in the PowerFit family, providing ample space for cable management and a secure grip surface.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Who needs PFLD-2Y-S120M40A and what problem does it solve?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-2Y-S120M40A is a KUPO PowerFit 400A line drain connector with a yellow housing, identifying Line 2 (L2) under UK (Old, pre-2004) conventions. As the drain side of an inline cable connection, it receives the mating source contact and provides a sealed, IP67-rated junction when coupled. The yellow housing enables instant visual identification of the L2 conductor across cable runs. It is commonly deployed in data center maintenance applications. During data center expansion or maintenance windows, temporary power must be distributed with absolute reliability.\"}}, {\"@type\": \"Question\", \"name\": \"What are the electrical ratings and wire capacity of PFLD-2Y-S120M40A?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-2Y-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for L2 circuits carrying continuous phase current.\"}}, {\"@type\": \"Question\", \"name\": \"What does the yellow housing on PFLD-2Y-S120M40A represent under UK (Old, pre-2004) standards?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yellow identifies L2 under the legacy UK wiring color code (red\/yellow\/blue for L1\/L2\/L3) used before the 2004 harmonization to IEC standards. Legacy UK installations, some Commonwealth countries, and specialty applications still use this color scheme. On the Line Drain connector, the yellow housing is visible along the full 190mm body length, making L2 identification easy even when cables are bundled tightly. The ergonomic rubber grip section also carries the color, so technicians can identify the phase while handling the connector. When maintaining or extending pre-2004 UK installations, matching the existing yellow L2 convention prevents confusion between old and new color systems.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and safety ratings does PFLD-2Y-S120M40A carry?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-2Y-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The silicone O-ring seal contributes to the IP67 rating when mated, meaning the connection is fully protected against dust ingress and temporary immersion in water up to 1 meter for 30 minutes.\"}}, {\"@type\": \"Question\", \"name\": \"Is PFLD-2Y-S120M40A compatible with single-pole connectors from other manufacturers?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PowerFit connectors are designed to be compatible with major brands of single-pole power connector. The 0.1 milliohm contact resistance minimizes heat generation at connection points, the 500-cycle mating rating supports repeated connect\/disconnect during maintenance, and the 1000V AC \/ 1500V DC rating provides margin for high-voltage DC distribution architectures. For L2 circuits using UK (Old, pre-2004) color conventions, the yellow PFLD-2Y-S120M40A ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\"}}, {\"@type\": \"Question\", \"name\": \"How do you assemble PFLD-2Y-S120M40A onto a power cable in the field?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"To assemble PFLD-2Y-S120M40A, remove the M40 cable gland and extract the contact. Insert the contact into the insulator and align the cotter pin hole. Strip back the cable jacket by approximately 33mm, then slide the R120 reduction sleeve (brass with silver plating, up to 16.50mm wire diameter) over the exposed conductor. Hammer the cotter pin in from its chamfered side for proper seating. Slide the cable with reduction sleeve into the contact, then tighten both set screws using a 5mm hex key to a minimum of 10.5 N\/m. Finally, thread the cable gland back on. The M40 gland includes two rubber bushings (inner diameter 23mm and 33mm) for flexibility with different cable sizes. At 190mm total length with a 32.5mm body diameter, the Line Drain is the longest connector in the PowerFit family, providing ample space for cable management and a secure grip surface.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLD-2Y-S120M40A\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLD-2Y-S120M40A.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLD-2Y-S120M40A Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 400A \/ Inline Connector","offer_id":50208842776796,"sku":"PFLD-2Y-S120M40A","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLD-2Y-S120M40A.jpg?v=1777364431"},{"product_id":"pfls-2bk","title":"PFLS-2BK-S120M40A - PowerFit 400A Source Line Connector, Black (L2)","description":"\u003c!-- Combined Shopify product HTML for PFLS-2BK-S120M40A --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLS-2BK-S120M40A\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Line Source Connector (Black) | PFLS-2BK-S120M40A | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLS-2BK-S120M40A\" data-color=\"Black\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLS-2BK-S120M40A brings industrial-grade power distribution to European and IEC-standard installations. As a Line Source connector with male contact and patent key-release pin, this inline solution enables seamless mating to Drain connectors while supporting 400A continuous current. The black phase conductor aligns with IEC conventions for L2 applications across industrial facilities, temporary power systems, and event staging where reliable European power standards are required.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMale Contact with Key-Release Pin:\u003c\/strong\u003e Innovative push-and-twist design with tool-free disconnection via patent key-release mechanism for user safety and rapid reconnection workflows.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePush-and-Twist Connection:\u003c\/strong\u003e Intuitive mating procedure - no CAM tools or complex alignment steps required in high-pressure event environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact POM Cotter Pin:\u003c\/strong\u003e Shorter polyoxymethylene pin optimizes connector footprint while maintaining reliable locking; removable with small slotted screwdriver if field adjustment is needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e400A Continuous Capacity:\u003c\/strong\u003e Rated for 400A with 120mm² cable; upgradeable to 660A with 240mm² cable configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP67 Sealed Mating:\u003c\/strong\u003e Protects against dust, water spray, and temporary submersion when connectors are fully mated and locked.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eM40 Cable Gland with Dual Bushings:\u003c\/strong\u003e Nylon and rubber sealing system with 22mm and 33mm ID options ensures strain relief across cable diameter ranges.\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTÜV Rheinland:\u003c\/strong\u003e Certified (ID 1111303479)  -  Type Approval, Safety, Regular Production Surveillance\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCE Marked\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS \u0026amp; REACH:\u003c\/strong\u003e Fully compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-2BK-S120M40A excels in European and IEC-compliant installations:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial facilities with three-phase power distribution\u003c\/li\u003e\n\u003cli\u003eTemporary power systems for construction, theater, and event production\u003c\/li\u003e\n\u003cli\u003eData centers and critical infrastructure requiring 400A L2 branch circuits\u003c\/li\u003e\n\u003cli\u003eBroadcasting and live entertainment setups where rapid power deployment is essential\u003c\/li\u003e\n\u003cli\u003eRenewable energy installations (solar farms, wind systems) with European grid compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-2BK-S120M40A (Source) mates directly with PFLD-2BK-S120M40A (Line Drain) and PFPD-2BK (Panel Drain) connectors, completing power chains from source through distribution to branch circuits. This connector is compatible with major brands of single-pole power connector systems. Ensure matching phase conductors (L2 Black\/IEC) throughout the circuit to prevent cross-phasing.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLS-2BK-S120M40A | PowerFit 400A Line Source, L2 (Phase B) Black (IEC - European)\",\n  \"description\": \"KUPO PowerFit 400A Line Source single-pole connector with black housing for IEC - European power distribution systems. Male Contact, patent key-release pin for safe disconnection, M40 cable gland with sealing bushing, IP67 rated when mated, silver-plated brass contacts, dual-rated 400A\/660A, 1000V AC \/ 1500V DC maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLS-2BK-S120M40A\",\n  \"mpn\": \"PFLS-2BK-S120M40A\",\n  \"color\": \"Black\",\n  \"material\": \"Non-conductive thermoplastic housing; Brass silver-plated contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC \/ 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A continuous (120mm\u0026sup2; cable) \/ 660A continuous (240mm\u0026sup2; cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5 kiloamperes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Source (Male Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-Twist with Key-Release Mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cotter Pin Material\",\n      \"value\": \"POM (Polyoxymethylene)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing (Inner Diameter: 22mm and 33mm)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Set Screw Torque\",\n      \"value\": \"10.5 N\/meter minimum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"TUV Certification ID\",\n      \"value\": \"1111303479\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV Rheinland, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 (Phase B) (IEC - European)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Black\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLS-2BK-S120M40A\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhy was PFLS-2BK-S120M40A designed with a key-release mechanism?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2BK-S120M40A is a KUPO PowerFit 400A line source connector with a black housing, identifying Line 2 (L2) under Europe and UK (IEC 60446) conventions. As the source side of an inline cable connection, it features the innovative patent key-release pin that enables tool-free disconnection. The push-and-twist mechanism secures the connection during operation while allowing rapid uncoupling when needed. It is commonly deployed in industrial manufacturing plant applications. Temporary power in manufacturing environments faces vibration from heavy machinery, exposure to oils and cutting fluids, and the need for high current capacity to feed welders, presses, and large motors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat electrical performance does PFLS-2BK-S120M40A deliver?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2BK-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for L2 circuits carrying continuous phase current.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhy choose the black L2 variant (PFLS-2BK-S120M40A) for your installation?\u003c\/h3\u003e\n    \u003cp\u003eUnder IEC 60446, black identifies Line 2 (L2). This is the second phase conductor in the European three-phase system of brown (L1), black (L2), grey (L3). For international crews, this is a critical distinction: the same black housing that means L1 in North America means L2 in Europe. On the Line Source connector, the black housing wraps the 170mm body including the area around the key-release mechanism. This means the phase is identifiable even during the push-and-twist connection process, reducing the chance of connecting to the wrong L2 circuit. Cross-convention errors between NEC-L1-black and IEC-L2-black are among the most common phase identification mistakes on international projects.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety certifications apply to PFLS-2BK-S120M40A?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2BK-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The key-release pin mechanism has been certified as part of the TUV evaluation, ensuring that the disconnect feature meets the same safety standards as the connection itself.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs PFLS-2BK-S120M40A compatible with single-pole connectors from other manufacturers?\u003c\/h3\u003e\n    \u003cp\u003ePowerFit connectors are designed to be compatible with major brands of single-pole power connector. The 400A continuous rating (660A with 240mm2 cable) handles industrial loads, the flame-retardant UL94-V0 housing resists chemical exposure, and the push-and-twist lock prevents vibration-induced disconnection. For L2 circuits using Europe and UK (IEC 60446) color conventions, the black PFLS-2BK-S120M40A ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Why was PFLS-2BK-S120M40A designed with a key-release mechanism?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2BK-S120M40A is a KUPO PowerFit 400A line source connector with a black housing, identifying Line 2 (L2) under Europe and UK (IEC 60446) conventions. As the source side of an inline cable connection, it features the innovative patent key-release pin that enables tool-free disconnection. The push-and-twist mechanism secures the connection during operation while allowing rapid uncoupling when needed. It is commonly deployed in industrial manufacturing plant applications. Temporary power in manufacturing environments faces vibration from heavy machinery, exposure to oils and cutting fluids, and the need for high current capacity to feed welders, presses, and large motors.\"}}, {\"@type\": \"Question\", \"name\": \"What electrical performance does PFLS-2BK-S120M40A deliver?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2BK-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for L2 circuits carrying continuous phase current.\"}}, {\"@type\": \"Question\", \"name\": \"Why choose the black L2 variant (PFLS-2BK-S120M40A) for your installation?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Under IEC 60446, black identifies Line 2 (L2). This is the second phase conductor in the European three-phase system of brown (L1), black (L2), grey (L3). For international crews, this is a critical distinction: the same black housing that means L1 in North America means L2 in Europe. On the Line Source connector, the black housing wraps the 170mm body including the area around the key-release mechanism. This means the phase is identifiable even during the push-and-twist connection process, reducing the chance of connecting to the wrong L2 circuit. Cross-convention errors between NEC-L1-black and IEC-L2-black are among the most common phase identification mistakes on international projects.\"}}, {\"@type\": \"Question\", \"name\": \"What safety certifications apply to PFLS-2BK-S120M40A?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2BK-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The key-release pin mechanism has been certified as part of the TUV evaluation, ensuring that the disconnect feature meets the same safety standards as the connection itself.\"}}, {\"@type\": \"Question\", \"name\": \"Is PFLS-2BK-S120M40A compatible with single-pole connectors from other manufacturers?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PowerFit connectors are designed to be compatible with major brands of single-pole power connector. The 400A continuous rating (660A with 240mm2 cable) handles industrial loads, the flame-retardant UL94-V0 housing resists chemical exposure, and the push-and-twist lock prevents vibration-induced disconnection. For L2 circuits using Europe and UK (IEC 60446) color conventions, the black PFLS-2BK-S120M40A ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLS-2BK-S120M40A\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLS-2BK-S120M40A.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLS-2BK-S120M40A Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 400A \/ Inline Connector","offer_id":50208843563228,"sku":"PFLS-2BK-S120M40A","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLS-2BK-S120M40A-b.jpg?v=1777364443"},{"product_id":"pfls-2r","title":"PFLS-2R-S120M40A - PowerFit 400A Source Line Connector, Red (L2)","description":"\u003c!-- Combined Shopify product HTML for PFLS-2R-S120M40A --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLS-2R-S120M40A\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Line Source Connector (Red) | PFLS-2R-S120M40A | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLS-2R-S120M40A\" data-color=\"Red\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003ePurpose-built for North American power systems, the PFLS-2R-S120M40A delivers 400A L2 connectivity with the reliability expected in demanding event and entertainment applications. This Line Source connector features a male contact and patent key-release pin for intuitive push-and-twist mating, eliminating the need for complex tools or procedures during rapid deployment scenarios. Red phase identification follows NEC convention, making it the trusted choice for large-venue events, touring productions, and high-amperage temporary power installations where speed and safety cannot be compromised.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMale Contact with Patent Key-Release Pin:\u003c\/strong\u003e Effortless tool-free disconnection via proprietary key-release mechanism - designed for busy event technicians who need quick reconfiguration without equipment damage risk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePush-and-Twist Mating:\u003c\/strong\u003e No alignment tools, no CAM locks - simply push fully and twist to secure. Disconnect by engaging the key-release pin and pulling apart.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact POM Cotter Pin:\u003c\/strong\u003e Engineered shorter than Drain variants for optimal inline connector profile; field-serviceable with a small slotted screwdriver if needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e400A Continuous Rating:\u003c\/strong\u003e Tested for sustained 400A with 120mm² cable; scales to 660A with 240mm² cable options.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP67 Sealed When Mated:\u003c\/strong\u003e Full environmental protection during operation in outdoor events, rain, or moisture-prone venues.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNylon\/Rubber Cable Gland:\u003c\/strong\u003e M40 x 1.5 gland with 22mm\/33mm ID bushings ensures strain relief and cable retention across standard wire gauges.\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTÜV Rheinland Certification:\u003c\/strong\u003e ID 1111303479  -  Full Type Approval, Safety, and Production Surveillance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Declaration:\u003c\/strong\u003e European market authorization\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS \u0026amp; REACH Compliance:\u003c\/strong\u003e Fully certified for hazardous substance restrictions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-2R-S120M40A (Line Source, male contact) mates directly with PFLD-2R-S120M40A (Line Drain, female contact) and PFPD-2R (Panel Drain) connectors to form complete power distribution chains. This connector is compatible with major brands of single-pole power connector systems. Always match phase colors throughout the circuit (red L2 to red L2) to prevent cross-phasing and ensure electrical code compliance.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eThree-phase power source connections requiring dedicated L2 feed lines\u003c\/li\u003e\n      \u003cli\u003eEntertainment dimmer rack and lighting control source power feeds\u003c\/li\u003e\n      \u003cli\u003eIndustrial manufacturing source power connections with three-phase requirements\u003c\/li\u003e\n      \u003cli\u003ePower distribution source connections for mining and heavy industry operations\u003c\/li\u003e\n      \u003cli\u003eFestival and outdoor event source power feeds with weather-exposed installations\u003c\/li\u003e\n      \u003cli\u003eGenerator paralleling output connections requiring per-phase source management\u003c\/li\u003e\n      \u003cli\u003eUPS and bypass panel source power cabling for critical infrastructure\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLS-2R-S120M40A | PowerFit 400A Line Source, L2 (Phase B) Red (NEC - North American)\",\n  \"description\": \"KUPO PowerFit 400A Line Source single-pole connector with red housing for NEC - North American power distribution systems. Male Contact, patent key-release pin for safe disconnection, M40 cable gland with sealing bushing, IP67 rated when mated, silver-plated brass contacts, dual-rated 400A\/660A, 1000V AC \/ 1500V DC maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLS-2R-S120M40A\",\n  \"mpn\": \"PFLS-2R-S120M40A\",\n  \"color\": \"Red\",\n  \"material\": \"Non-conductive thermoplastic housing; Brass silver-plated contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC \/ 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A continuous (120mm\u0026sup2; cable) \/ 660A continuous (240mm\u0026sup2; cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5 kiloamperes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Source (Male Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-Twist with Key-Release Mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cotter Pin Material\",\n      \"value\": \"POM (Polyoxymethylene)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing (Inner Diameter: 22mm and 33mm)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Set Screw Torque\",\n      \"value\": \"10.5 N\/meter minimum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"TUV Certification ID\",\n      \"value\": \"1111303479\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV Rheinland, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 (Phase B) (NEC - North American)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Red\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLS-2R-S120M40A\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is PFLS-2R-S120M40A and what makes it innovative?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2R-S120M40A is a KUPO PowerFit 400A line source connector with a red housing, identifying Line 2 (L2) under North America (NEC) conventions. As the source side of an inline cable connection, it features the innovative patent key-release pin that enables tool-free disconnection. The push-and-twist mechanism secures the connection during operation while allowing rapid uncoupling when needed. It is commonly deployed in construction site applications. Construction power distribution deals with dust, debris, rain, rough handling by crews, and the constant repositioning of equipment as the site evolves.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat are the current and voltage specifications for PFLS-2R-S120M40A?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2R-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The insulation resistance exceeds 5000 megaohms at 500V AC, and the test voltage rating of 4500V AC provides substantial safety margin. The short circuit rating of up to 35.5 kiloamperes means the connector can withstand fault conditions without catastrophic failure.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhy choose the red L2 variant (PFLS-2R-S120M40A) for your installation?\u003c\/h3\u003e\n    \u003cp\u003eRed marks Line 2 (L2) under North American NEC conventions. In a standard three-phase system, the color sequence is black (L1), red (L2), blue (L3). Red L2 is one of the most commonly ordered phase variants for US and Canadian power distribution, appearing in virtually every multi-phase temporary power installation. On the Line Source connector, the red housing wraps the 170mm body including the area around the key-release mechanism. This means the phase is identifiable even during the push-and-twist connection process, reducing the chance of connecting to the wrong L2 circuit. Red is one of the most visually distinctive colors on a busy event site, helping crews quickly trace the second phase conductor even from a distance.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs PFLS-2R-S120M40A independently tested and certified?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2R-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The key-release pin mechanism has been certified as part of the TUV evaluation, ensuring that the disconnect feature meets the same safety standards as the connection itself.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the assembly and disconnection process for PFLS-2R-S120M40A?\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-2R-S120M40A features the innovative PowerFit push-and-twist connection. To connect, align the connector and push while twisting until it locks. To disconnect, the patent key-release pin enables tool-free uncoupling. Simply press the release and twist to separate. If needed, a small slotted screwdriver can assist with the release. For cable termination, the process follows the same steps as other PowerFit line connectors: strip 33mm of cable jacket, apply the reduction sleeve, tighten set screws to 10.5 N\/m minimum, and secure the M40 cable gland. Uses the shorter cotter pin variant (vs the longer pin in Line Drain). The shorter pin accommodates the key-release mechanism. Never reuse cotter pins.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does PFLS-2R-S120M40A compare to traditional single-pole power connectors?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2R-S120M40A offers several meaningful improvements over conventional single-pole power connectors: the integrated M40 cable gland with sealing bushing provides cable strain relief and environmental protection in a single assembly; the patent key-release pin enables tool-free disconnection that traditional locking mechanisms cannot match; IP67 protection when mated provides dust-tight and waterproof sealing that most single-pole connectors lack. These features, combined with TUV Rheinland certification and the phase-encoded red housing for L2 identification, make PowerFit a generation ahead of traditional designs.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is PFLS-2R-S120M40A and what makes it innovative?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2R-S120M40A is a KUPO PowerFit 400A line source connector with a red housing, identifying Line 2 (L2) under North America (NEC) conventions. As the source side of an inline cable connection, it features the innovative patent key-release pin that enables tool-free disconnection. The push-and-twist mechanism secures the connection during operation while allowing rapid uncoupling when needed. It is commonly deployed in construction site applications. Construction power distribution deals with dust, debris, rain, rough handling by crews, and the constant repositioning of equipment as the site evolves.\"}}, {\"@type\": \"Question\", \"name\": \"What are the current and voltage specifications for PFLS-2R-S120M40A?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2R-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The insulation resistance exceeds 5000 megaohms at 500V AC, and the test voltage rating of 4500V AC provides substantial safety margin. The short circuit rating of up to 35.5 kiloamperes means the connector can withstand fault conditions without catastrophic failure.\"}}, {\"@type\": \"Question\", \"name\": \"Why choose the red L2 variant (PFLS-2R-S120M40A) for your installation?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Red marks Line 2 (L2) under North American NEC conventions. In a standard three-phase system, the color sequence is black (L1), red (L2), blue (L3). Red L2 is one of the most commonly ordered phase variants for US and Canadian power distribution, appearing in virtually every multi-phase temporary power installation. On the Line Source connector, the red housing wraps the 170mm body including the area around the key-release mechanism. This means the phase is identifiable even during the push-and-twist connection process, reducing the chance of connecting to the wrong L2 circuit. Red is one of the most visually distinctive colors on a busy event site, helping crews quickly trace the second phase conductor even from a distance.\"}}, {\"@type\": \"Question\", \"name\": \"Is PFLS-2R-S120M40A independently tested and certified?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2R-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The key-release pin mechanism has been certified as part of the TUV evaluation, ensuring that the disconnect feature meets the same safety standards as the connection itself.\"}}, {\"@type\": \"Question\", \"name\": \"What is the assembly and disconnection process for PFLS-2R-S120M40A?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The PFLS-2R-S120M40A features the innovative PowerFit push-and-twist connection. To connect, align the connector and push while twisting until it locks. To disconnect, the patent key-release pin enables tool-free uncoupling. Simply press the release and twist to separate. If needed, a small slotted screwdriver can assist with the release. For cable termination, the process follows the same steps as other PowerFit line connectors: strip 33mm of cable jacket, apply the reduction sleeve, tighten set screws to 10.5 N\/m minimum, and secure the M40 cable gland. Uses the shorter cotter pin variant (vs the longer pin in Line Drain). The shorter pin accommodates the key-release mechanism. Never reuse cotter pins.\"}}, {\"@type\": \"Question\", \"name\": \"How does PFLS-2R-S120M40A compare to traditional single-pole power connectors?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2R-S120M40A offers several meaningful improvements over conventional single-pole power connectors: the integrated M40 cable gland with sealing bushing provides cable strain relief and environmental protection in a single assembly; the patent key-release pin enables tool-free disconnection that traditional locking mechanisms cannot match; IP67 protection when mated provides dust-tight and waterproof sealing that most single-pole connectors lack. These features, combined with TUV Rheinland certification and the phase-encoded red housing for L2 identification, make PowerFit a generation ahead of traditional designs.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLS-2R-S120M40A\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLS-2R-S120M40A.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLS-2R-S120M40A Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 400A \/ Inline Connector","offer_id":50208843595996,"sku":"PFLS-2R-S120M40A","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLS-2R-S120M40A.jpg?v=1777364445"},{"product_id":"pfls-2w","title":"PFLS-2W-S120M40A - PowerFit 400A Source Line Connector, White (L2)","description":"\u003c!-- Combined Shopify product HTML for PFLS-2W-S120M40A --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLS-2W-S120M40A\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Line Source Connector (White) | PFLS-2W-S120M40A | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLS-2W-S120M40A\" data-color=\"White\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eBuilt to meet Australian and New Zealand power distribution standards, the PFLS-2W-S120M40A provides 400A L2 connectivity with proven reliability under demanding environmental conditions. This Line Source connector integrates a male contact and patent key-release pin to enable rapid, tool-free disconnection - critical in outdoor venues, touring production systems, and mining\/industrial operations where environmental exposure is intense. White phase identification aligns with AS\/NZS 3000 color coding, ensuring seamless integration into Australia-Pacific power infrastructure.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMale Contact \u0026amp; Patent Key-Release Pin:\u003c\/strong\u003e Proprietary push-and-twist design with tool-free release mechanism eliminates the need for CAM keys or specialty tools in field conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePush-and-Twist Interface:\u003c\/strong\u003e Intuitive mating procedure - fully insert and rotate to lock; disengage key-release pin to disconnect. No complex alignment or calibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized POM Cotter Pin:\u003c\/strong\u003e Compact polyoxymethylene pin design specific to Source connectors; field-adjustable with small slotted screwdriver if required during maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e400A Rated Continuous Capacity:\u003c\/strong\u003e Tested at 400A with 120mm² cable; expandable to 660A using 240mm² cable configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP67 Protection When Mated:\u003c\/strong\u003e Full dust and water ingress protection - rated for coastal spray, high-humidity mining sites, and outdoor event exposure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Cable Gland:\u003c\/strong\u003e M40 x 1.5 specification with nylon and rubber sealing; 22mm and 33mm ID bushing options accommodate varied conductor diameters.\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTÜV Rheinland Certification:\u003c\/strong\u003e ID 1111303479  -  Type Approval, Safety, Regular Production Surveillance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Marked:\u003c\/strong\u003e European Union market authorization\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS \u0026amp; REACH Certified:\u003c\/strong\u003e Hazardous substance restrictions compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAS\/NZS Compatibility:\u003c\/strong\u003e Engineered for Australian and New Zealand electrical standards with white L2 phase designation\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eThree-phase power source connections requiring dedicated L2 feed lines\u003c\/li\u003e\n      \u003cli\u003eEntertainment dimmer rack and lighting control source power feeds\u003c\/li\u003e\n      \u003cli\u003eIndustrial manufacturing source power connections with three-phase requirements\u003c\/li\u003e\n      \u003cli\u003ePower distribution source connections for mining and heavy industry operations\u003c\/li\u003e\n      \u003cli\u003eFestival and outdoor event source power feeds with weather-exposed installations\u003c\/li\u003e\n      \u003cli\u003eGenerator paralleling output connections requiring per-phase source management\u003c\/li\u003e\n      \u003cli\u003eUPS and bypass panel source power cabling for critical infrastructure\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe PowerFit 400A Line Source connector is compatible with major brands of single-pole power connector systems. Its push-and-twist mating mechanism with patent key-release pin ensures standardized connection geometry across certified suppliers. The male contact mates with PowerFit Line Drain and Panel Drain connectors. Verify mechanical and electrical specifications with your mating connector manufacturer to confirm impedance matching and safe operating parameters. Use the color-coded and mechanically keyed design as a visual safeguard to prevent cross-phase connection errors during installation or reconfiguration.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLS-2W-S120M40A | PowerFit 400A Line Source, L2 (Phase B) White (Australian)\",\n  \"description\": \"KUPO PowerFit 400A Line Source single-pole connector with white housing for Australian power distribution systems. Male Contact, patent key-release pin for safe disconnection, M40 cable gland with sealing bushing, IP67 rated when mated, silver-plated brass contacts, dual-rated 400A\/660A, 1000V AC \/ 1500V DC maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLS-2W-S120M40A\",\n  \"mpn\": \"PFLS-2W-S120M40A\",\n  \"color\": \"White\",\n  \"material\": \"Non-conductive thermoplastic housing; Brass silver-plated contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC \/ 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A continuous (120mm\u0026sup2; cable) \/ 660A continuous (240mm\u0026sup2; cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5 kiloamperes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Source (Male Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-Twist with Key-Release Mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cotter Pin Material\",\n      \"value\": \"POM (Polyoxymethylene)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing (Inner Diameter: 22mm and 33mm)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Set Screw Torque\",\n      \"value\": \"10.5 N\/meter minimum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"TUV Certification ID\",\n      \"value\": \"1111303479\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV Rheinland, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 (Phase B) (Australian)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"White\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLS-2W-S120M40A\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does PFLS-2W-S120M40A improve on traditional single-pole power connectors?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2W-S120M40A is a KUPO PowerFit 400A line source connector with a white housing, identifying Line 2 (L2) under Australia conventions. As the source side of an inline cable connection, it features the innovative patent key-release pin that enables tool-free disconnection. The push-and-twist mechanism secures the connection during operation while allowing rapid uncoupling when needed. It is commonly deployed in marine and shipyard applications. Shipyard and dockside power connections face salt spray, high humidity, and the corrosive marine environment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does PFLS-2W-S120M40A maintain electrical integrity at high current loads?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2W-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The M40 cable gland accommodates cables through two included rubber bushings (inner diameter 23mm and 33mm), and the R120 reduction sleeve (brass with silver plating) handles conductor diameters up to 16.50mm. Set screws require a minimum torque of 10.5 N\/m for reliable termination.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhy choose the white L2 variant (PFLS-2W-S120M40A) for your installation?\u003c\/h3\u003e\n    \u003cp\u003eWhite as L2 follows Australian wiring conventions, where the three-phase set is red (L1), white (L2), blue (L3). This variant specifically serves Australian, New Zealand, and related Asia-Pacific markets. On the Line Source connector, the white housing wraps the 170mm body including the area around the key-release mechanism. This means the phase is identifiable even during the push-and-twist connection process, reducing the chance of connecting to the wrong L2 circuit. The stark visual contrast between white L2 and the darker L1\/L3 conductors makes phase tracing straightforward in Australian installations.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat makes PFLS-2W-S120M40A safe for professional high-current applications?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2W-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The key-release pin mechanism has been certified as part of the TUV evaluation, ensuring that the disconnect feature meets the same safety standards as the connection itself.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat makes PFLS-2W-S120M40A versatile for marine and shipyard applications?\u003c\/h3\u003e\n    \u003cp\u003ePowerFit connectors are designed to be compatible with major brands of single-pole power connector. Silver-plated brass contacts resist corrosion far better than plain brass, the silicone O-ring maintains IP67 sealing in high-humidity conditions, and the non-conductive thermoplastic housing is impervious to salt corrosion. For L2 circuits using Australia color conventions, the white PFLS-2W-S120M40A ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow do you connect and disconnect PFLS-2W-S120M40A in the field?\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-2W-S120M40A features the innovative PowerFit push-and-twist connection. To connect, align the connector and push while twisting until it locks. To disconnect, the patent key-release pin enables tool-free uncoupling. Simply press the release and twist to separate. If needed, a small slotted screwdriver can assist with the release. For cable termination, the process follows the same steps as other PowerFit line connectors: strip 33mm of cable jacket, apply the reduction sleeve, tighten set screws to 10.5 N\/m minimum, and secure the M40 cable gland. Uses the shorter cotter pin variant (vs the longer pin in Line Drain). The shorter pin accommodates the key-release mechanism. Never reuse cotter pins.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"How does PFLS-2W-S120M40A improve on traditional single-pole power connectors?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2W-S120M40A is a KUPO PowerFit 400A line source connector with a white housing, identifying Line 2 (L2) under Australia conventions. As the source side of an inline cable connection, it features the innovative patent key-release pin that enables tool-free disconnection. The push-and-twist mechanism secures the connection during operation while allowing rapid uncoupling when needed. It is commonly deployed in marine and shipyard applications. Shipyard and dockside power connections face salt spray, high humidity, and the corrosive marine environment.\"}}, {\"@type\": \"Question\", \"name\": \"How does PFLS-2W-S120M40A maintain electrical integrity at high current loads?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2W-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The M40 cable gland accommodates cables through two included rubber bushings (inner diameter 23mm and 33mm), and the R120 reduction sleeve (brass with silver plating) handles conductor diameters up to 16.50mm. Set screws require a minimum torque of 10.5 N\/m for reliable termination.\"}}, {\"@type\": \"Question\", \"name\": \"Why choose the white L2 variant (PFLS-2W-S120M40A) for your installation?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"White as L2 follows Australian wiring conventions, where the three-phase set is red (L1), white (L2), blue (L3). This variant specifically serves Australian, New Zealand, and related Asia-Pacific markets. On the Line Source connector, the white housing wraps the 170mm body including the area around the key-release mechanism. This means the phase is identifiable even during the push-and-twist connection process, reducing the chance of connecting to the wrong L2 circuit. The stark visual contrast between white L2 and the darker L1\/L3 conductors makes phase tracing straightforward in Australian installations.\"}}, {\"@type\": \"Question\", \"name\": \"What makes PFLS-2W-S120M40A safe for professional high-current applications?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2W-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The key-release pin mechanism has been certified as part of the TUV evaluation, ensuring that the disconnect feature meets the same safety standards as the connection itself.\"}}, {\"@type\": \"Question\", \"name\": \"What makes PFLS-2W-S120M40A versatile for marine and shipyard applications?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PowerFit connectors are designed to be compatible with major brands of single-pole power connector. Silver-plated brass contacts resist corrosion far better than plain brass, the silicone O-ring maintains IP67 sealing in high-humidity conditions, and the non-conductive thermoplastic housing is impervious to salt corrosion. For L2 circuits using Australia color conventions, the white PFLS-2W-S120M40A ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\"}}, {\"@type\": \"Question\", \"name\": \"How do you connect and disconnect PFLS-2W-S120M40A in the field?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The PFLS-2W-S120M40A features the innovative PowerFit push-and-twist connection. To connect, align the connector and push while twisting until it locks. To disconnect, the patent key-release pin enables tool-free uncoupling. Simply press the release and twist to separate. If needed, a small slotted screwdriver can assist with the release. For cable termination, the process follows the same steps as other PowerFit line connectors: strip 33mm of cable jacket, apply the reduction sleeve, tighten set screws to 10.5 N\/m minimum, and secure the M40 cable gland. Uses the shorter cotter pin variant (vs the longer pin in Line Drain). The shorter pin accommodates the key-release mechanism. Never reuse cotter pins.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLS-2W-S120M40A\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLS-2W-S120M40A.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLS-2W-S120M40A Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 400A \/ Inline Connector","offer_id":50208843628764,"sku":"PFLS-2W-S120M40A","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLS-2W-S120M40A-b.jpg?v=1777364447"},{"product_id":"pfls-2y","title":"PFLS-2Y-S120M40A - PowerFit 400A Source Line Connector, Yellow (L2)","description":"\u003c!-- Combined Shopify product HTML for PFLS-2Y-S120M40A --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLS-2Y-S120M40A\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Line Source Connector (Yellow) | PFLS-2Y-S120M40A | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLS-2Y-S120M40A\" data-color=\"Yellow\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLS-2Y-S120M40A bridges legacy UK electrical infrastructure with modern safety and performance. Designed for installations using older IEE wiring conventions where yellow designates L2 phase, this Line Source connector delivers 400A continuous capacity with the innovation of a patent key-release pin and push-and-twist mating interface. Yellow phase identification ensures compatibility with heritage installations, touring equipment pre-wired to IEE standards, and mixed-vintage systems where gradual migration to current standards is underway. Male contact design and tool-free disconnection make field servicing seamless.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMale Contact with Patent Key-Release Pin:\u003c\/strong\u003e Proprietary disconnect mechanism eliminates the need for CAM tools or field adjustment - simply push and twist to mate, engage the key-release pin to disconnect.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePush-and-Twist Connection Method:\u003c\/strong\u003e Intuitive, repeatable mating procedure with no complex alignment or calibration required during setup or teardown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact POM Cotter Pin:\u003c\/strong\u003e Shorter polyoxymethylene pin optimized for Source variants; removable and re-seatable with a small slotted screwdriver if field maintenance becomes necessary.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e400A Continuous Rating:\u003c\/strong\u003e Rated for 400A with 120mm² cable; supports 660A configurations using 240mm² cable options.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP67 Sealed Connection:\u003c\/strong\u003e Full environmental protection when mated - suitable for outdoor event stages, weather-exposed touring rigs, and damp indoor venues.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Cable Management:\u003c\/strong\u003e M40 x 1.5 cable gland with nylon\/rubber sealing and 22mm\/33mm ID bushing options ensures strain relief across conductor sizes.\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTÜV Rheinland:\u003c\/strong\u003e Certified (ID 1111303479)  -  Type Approval, Safety, Regular Production Surveillance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Marking:\u003c\/strong\u003e Full European Union authorization\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS \u0026amp; REACH:\u003c\/strong\u003e Hazardous substance compliance confirmed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUK Legacy Compatibility:\u003c\/strong\u003e Yellow L2 phase identification aligns with IEE wiring color convention used in pre-2004 UK installations\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-2Y-S120M40A (Line Source, male contact) mates directly with PFLD-2Y-S120M40A (Line Drain, female contact) and PFPD-2Y (Panel Drain) connectors. This connector is compatible with major brands of single-pole power connector systems. Maintain yellow L2 phase consistency throughout circuits to prevent cross-phasing errors and equipment damage. When integrating with modern BS 7909 systems (which use black for L2), implement clear labeling and safety procedures to prevent accidental misconnection.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eThree-phase power source connections requiring dedicated L2 feed lines\u003c\/li\u003e\n      \u003cli\u003eEntertainment dimmer rack and lighting control source power feeds\u003c\/li\u003e\n      \u003cli\u003eIndustrial manufacturing source power connections with three-phase requirements\u003c\/li\u003e\n      \u003cli\u003ePower distribution source connections for mining and heavy industry operations\u003c\/li\u003e\n      \u003cli\u003eFestival and outdoor event source power feeds with weather-exposed installations\u003c\/li\u003e\n      \u003cli\u003eGenerator paralleling output connections requiring per-phase source management\u003c\/li\u003e\n      \u003cli\u003eUPS and bypass panel source power cabling for critical infrastructure\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLS-2Y-S120M40A | PowerFit 400A Line Source, L2 (Phase B) Yellow (UK (Old Standard))\",\n  \"description\": \"KUPO PowerFit 400A Line Source single-pole connector with yellow housing for UK (Old Standard) power distribution systems. Male Contact, patent key-release pin for safe disconnection, M40 cable gland with sealing bushing, IP67 rated when mated, silver-plated brass contacts, dual-rated 400A\/660A, 1000V AC \/ 1500V DC maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLS-2Y-S120M40A\",\n  \"mpn\": \"PFLS-2Y-S120M40A\",\n  \"color\": \"Yellow\",\n  \"material\": \"Non-conductive thermoplastic housing; Brass silver-plated contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC \/ 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A continuous (120mm\u0026sup2; cable) \/ 660A continuous (240mm\u0026sup2; cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5 kiloamperes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Source (Male Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-Twist with Key-Release Mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cotter Pin Material\",\n      \"value\": \"POM (Polyoxymethylene)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing (Inner Diameter: 22mm and 33mm)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Set Screw Torque\",\n      \"value\": \"10.5 N\/meter minimum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"TUV Certification ID\",\n      \"value\": \"1111303479\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV Rheinland, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 (Phase B) (UK (Old Standard))\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Yellow\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLS-2Y-S120M40A\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the purpose of PFLS-2Y-S120M40A in a PowerFit distribution setup?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2Y-S120M40A is a KUPO PowerFit 400A line source connector with a yellow housing, identifying Line 2 (L2) under UK (Old, pre-2004) conventions. As the source side of an inline cable connection, it features the innovative patent key-release pin that enables tool-free disconnection. The push-and-twist mechanism secures the connection during operation while allowing rapid uncoupling when needed. It is commonly deployed in data center maintenance applications. During data center expansion or maintenance windows, temporary power must be distributed with absolute reliability.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat electrical performance does PFLS-2Y-S120M40A deliver?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2Y-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for L2 circuits carrying continuous phase current.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhy choose the yellow L2 variant (PFLS-2Y-S120M40A) for your installation?\u003c\/h3\u003e\n    \u003cp\u003eYellow identifies L2 under the legacy UK wiring color code (red\/yellow\/blue for L1\/L2\/L3) used before the 2004 harmonization to IEC standards. Legacy UK installations, some Commonwealth countries, and specialty applications still use this color scheme. On the Line Source connector, the yellow housing wraps the 170mm body including the area around the key-release mechanism. This means the phase is identifiable even during the push-and-twist connection process, reducing the chance of connecting to the wrong L2 circuit. When maintaining or extending pre-2004 UK installations, matching the existing yellow L2 convention prevents confusion between old and new color systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety certifications apply to PFLS-2Y-S120M40A?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2Y-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The key-release pin mechanism has been certified as part of the TUV evaluation, ensuring that the disconnect feature meets the same safety standards as the connection itself.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does the key-release mechanism work on PFLS-2Y-S120M40A?\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-2Y-S120M40A features the innovative PowerFit push-and-twist connection. To connect, align the connector and push while twisting until it locks. To disconnect, the patent key-release pin enables tool-free uncoupling. Simply press the release and twist to separate. If needed, a small slotted screwdriver can assist with the release. For cable termination, the process follows the same steps as other PowerFit line connectors: strip 33mm of cable jacket, apply the reduction sleeve, tighten set screws to 10.5 N\/m minimum, and secure the M40 cable gland. Uses the shorter cotter pin variant (vs the longer pin in Line Drain). The shorter pin accommodates the key-release mechanism. Never reuse cotter pins.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs PFLS-2Y-S120M40A compatible with single-pole connectors from other manufacturers?\u003c\/h3\u003e\n    \u003cp\u003ePowerFit connectors are designed to be compatible with major brands of single-pole power connector. The 0.1 milliohm contact resistance minimizes heat generation at connection points, the 500-cycle mating rating supports repeated connect\/disconnect during maintenance, and the 1000V AC \/ 1500V DC rating provides margin for high-voltage DC distribution architectures. For L2 circuits using UK (Old, pre-2004) color conventions, the yellow PFLS-2Y-S120M40A ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the purpose of PFLS-2Y-S120M40A in a PowerFit distribution setup?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2Y-S120M40A is a KUPO PowerFit 400A line source connector with a yellow housing, identifying Line 2 (L2) under UK (Old, pre-2004) conventions. As the source side of an inline cable connection, it features the innovative patent key-release pin that enables tool-free disconnection. The push-and-twist mechanism secures the connection during operation while allowing rapid uncoupling when needed. It is commonly deployed in data center maintenance applications. During data center expansion or maintenance windows, temporary power must be distributed with absolute reliability.\"}}, {\"@type\": \"Question\", \"name\": \"What electrical performance does PFLS-2Y-S120M40A deliver?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2Y-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for L2 circuits carrying continuous phase current.\"}}, {\"@type\": \"Question\", \"name\": \"Why choose the yellow L2 variant (PFLS-2Y-S120M40A) for your installation?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yellow identifies L2 under the legacy UK wiring color code (red\/yellow\/blue for L1\/L2\/L3) used before the 2004 harmonization to IEC standards. Legacy UK installations, some Commonwealth countries, and specialty applications still use this color scheme. On the Line Source connector, the yellow housing wraps the 170mm body including the area around the key-release mechanism. This means the phase is identifiable even during the push-and-twist connection process, reducing the chance of connecting to the wrong L2 circuit. When maintaining or extending pre-2004 UK installations, matching the existing yellow L2 convention prevents confusion between old and new color systems.\"}}, {\"@type\": \"Question\", \"name\": \"What safety certifications apply to PFLS-2Y-S120M40A?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2Y-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The key-release pin mechanism has been certified as part of the TUV evaluation, ensuring that the disconnect feature meets the same safety standards as the connection itself.\"}}, {\"@type\": \"Question\", \"name\": \"How does the key-release mechanism work on PFLS-2Y-S120M40A?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The PFLS-2Y-S120M40A features the innovative PowerFit push-and-twist connection. To connect, align the connector and push while twisting until it locks. To disconnect, the patent key-release pin enables tool-free uncoupling. Simply press the release and twist to separate. If needed, a small slotted screwdriver can assist with the release. For cable termination, the process follows the same steps as other PowerFit line connectors: strip 33mm of cable jacket, apply the reduction sleeve, tighten set screws to 10.5 N\/m minimum, and secure the M40 cable gland. Uses the shorter cotter pin variant (vs the longer pin in Line Drain). The shorter pin accommodates the key-release mechanism. Never reuse cotter pins.\"}}, {\"@type\": \"Question\", \"name\": \"Is PFLS-2Y-S120M40A compatible with single-pole connectors from other manufacturers?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PowerFit connectors are designed to be compatible with major brands of single-pole power connector. The 0.1 milliohm contact resistance minimizes heat generation at connection points, the 500-cycle mating rating supports repeated connect\/disconnect during maintenance, and the 1000V AC \/ 1500V DC rating provides margin for high-voltage DC distribution architectures. For L2 circuits using UK (Old, pre-2004) color conventions, the yellow PFLS-2Y-S120M40A ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLS-2Y-S120M40A\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLS-2Y-S120M40A.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLS-2Y-S120M40A Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 400A \/ Inline Connector","offer_id":50208843661532,"sku":"PFLS-2Y-S120M40A","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLS-2Y-S120M40A.jpg?v=1777364449"},{"product_id":"pfpd-2bk","title":"PFPD-2BK - PowerFit 400A Drain Panel Connector, Black (L2)","description":"\u003c!-- Combined Shopify product HTML for PFPD-2BK --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPD-2BK\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Panel Drain Connector (Black) | PFPD-2BK | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPD-2BK\" data-color=\"Black\"\u003e\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eIndustrial mining operations in remote locations depend on distribution infrastructure that delivers consistent 400A power to drill site equipment, milling operations, and personnel facilities across isolated terrain. The PowerFit 400A Panel Drain connector in black (Phase 2 \/ L2 IEC) provides the permanent enclosure-mount architecture for secondary phase distribution in mining power systems, offering color-coded IEC compliance for multinational mining consortia operating equipment sourced from European manufacturers. The innovative plastic end cap shields live electrical surfaces from contact in dusty, high-vibration underground and surface mining environments, while the patent key-release pin mechanism permits safe maintenance disconnection without special tools.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003e400A continuous current rating at 120mm² cable; 660A at 240mm² cable for large mining distribution systems\u003c\/li\u003e\n      \u003cli\u003eFemale contact design ensures secure mating with Panel Source connectors in remote equipment cabinets\u003c\/li\u003e\n      \u003cli\u003eM12 threaded post with brass nut and spring washer provides reliable fastening in mining site vibration conditions\u003c\/li\u003e\n      \u003cli\u003eFour diameter 5.5mm fixing holes on flange (42mm  x  42mm cut-out) accommodate standard cabinet frame mounting\u003c\/li\u003e\n      \u003cli\u003ePatent key-release pin allows maintenance crews to safely disconnect power feeds without mechanical locking tools\u003c\/li\u003e\n      \u003cli\u003ePlastic end cap over female contact provides IP 2X finger protection - essential in high-dust mining environments\u003c\/li\u003e\n      \u003cli\u003ePush-and-twist locking mechanism resists vibration-induced disconnection from drilling equipment and heavy machinery\u003c\/li\u003e\n      \u003cli\u003eSilver-plated brass contact delivers 0.1 milliohms contact resistance across hundreds of megawatt-hour daily power cycles\u003c\/li\u003e\n      \u003cli\u003eNon-conductive UL94-V0 thermoplastic housing meets international mining safety standards for dusty environments\u003c\/li\u003e\n      \u003cli\u003eIP67 rating while mated protects against dust and moisture in open-pit and underground mining operations\u003c\/li\u003e\n      \u003cli\u003eMaximum nut torque: 12 to 14 N\/meter ensures secure fastening under extreme environmental conditions\u003c\/li\u003e\n      \u003cli\u003eBlack color codes as Phase 2 (L2) under IEC 60446, providing international standard phase identification\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eTÜV Rheinland certified (ID 1111303479) for global mining industry compliance\u003c\/li\u003e\n      \u003cli\u003eCE marking for international mining equipment certification\u003c\/li\u003e\n      \u003cli\u003eRoHS and REACH compliant for environmental responsibility in mining operations\u003c\/li\u003e\n      \u003cli\u003eUL94-V0 flame retardancy rating for mining safety standards\u003c\/li\u003e\n      \u003cli\u003eIP67 rating (dust-tight, temporary submersion-resistant) suitable for dusty mining site installations\u003c\/li\u003e\n      \u003cli\u003e1000V AC \/ 1500V DC maximum operating voltage; 4500V AC dielectric test\u003c\/li\u003e\n      \u003cli\u003eShort circuit rating: Up to 35.5kA; insulation resistance greater than 5000 megohms at 500V AC\u003c\/li\u003e\n      \u003cli\u003eWorking temperature range: 45 to 85 degrees Celsius - stable across hot desert and cold mountain mining operations\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eOpen-pit and underground mining operation distribution cabinets for multi-phase power delivery\u003c\/li\u003e\n      \u003cli\u003eMill and processing facility power interconnection systems for ore processing equipment\u003c\/li\u003e\n      \u003cli\u003eDrill site temporary and permanent power distribution for remote mine development\u003c\/li\u003e\n      \u003cli\u003eMining equipment depot power management for charging and servicing heavy machinery\u003c\/li\u003e\n      \u003cli\u003eWater treatment and dewatering system electrical infrastructure at mine sites\u003c\/li\u003e\n      \u003cli\u003eRemote mining camp electrical systems for personnel facilities and safety equipment\u003c\/li\u003e\n      \u003cli\u003eMining convoy and transport equipment fueling and electrical service stations\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe PowerFit 400A Panel Drain connector is compatible with major brands of single-pole power connector systems used in mining equipment sourced from international suppliers. Its M12 threaded post interface and push-and-twist mating mechanism follow standardized connection geometry across certified suppliers. Verify that your Panel Source connector carries appropriate certifications for mining service and matches your power distribution system voltage and amperage specifications. The color-coded black housing complies with IEC 60446 L2 phase identification used by multinational mining equipment manufacturers.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPD-2BK | PowerFit 400A Panel Drain, L2 (Phase B) Black (IEC - European)\",\n  \"description\": \"KUPO PowerFit 400A Panel Drain single-pole connector with black housing for IEC - European power distribution systems. Female Contact, M12 threaded post mount, IP67 rated when mated, silver-plated brass contacts, dual-rated 400A\/660A, 1000V AC \/ 1500V DC maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Panel-Mount Connectors \u003e PowerFit\",\n  \"sku\": \"PFPD-2BK\",\n  \"mpn\": \"PFPD-2BK\",\n  \"color\": \"Black\",\n  \"material\": \"Non-conductive thermoplastic housing; Brass silver-plated contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC \/ 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A continuous (120mm\u0026sup2; cable) \/ 660A continuous (240mm\u0026sup2; cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5 kiloamperes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Drain (Female Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-Twist Lock\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mounting Type\",\n      \"value\": \"Panel Mount with M12 Threaded Post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fixing Holes\",\n      \"value\": \"Four diameter 5.5mm holes; 42mm x 42mm cut-out dimension\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fastener Material\",\n      \"value\": \"Brass nut and spring washer\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Maximum Nut Torque\",\n      \"value\": \"12 to 14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated; IP 2X finger protection\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"TUV Certification ID\",\n      \"value\": \"1111303479\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV Rheinland, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 (Phase B) (IEC - European)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Black\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPD-2BK\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat kind of installations require PFPD-2BK?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2BK is a KUPO PowerFit 400A panel drain connector with a black housing, identifying Line 2 (L2) under Europe and UK (IEC 60446) conventions. Mounted permanently in enclosures and distribution boxes, it serves as the final destination in the PowerFit electric direction flow, where incoming power from Line Source connectors enters the downstream equipment. The four-point flange mount and M12 threaded post ensure vibration-resistant installation. It is commonly deployed in industrial manufacturing plant applications. Temporary power in manufacturing environments faces vibration from heavy machinery, exposure to oils and cutting fluids, and the need for high current capacity to feed welders, presses, and large motors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat are the electrical specifications of PFPD-2BK for panel installations?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2BK is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for L2 circuits carrying continuous phase current.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does the black color coding on PFPD-2BK help identify L2 on the jobsite?\u003c\/h3\u003e\n    \u003cp\u003eUnder IEC 60446, black identifies Line 2 (L2). This is the second phase conductor in the European three-phase system of brown (L1), black (L2), grey (L3). For international crews, this is a critical distinction: the same black housing that means L1 in North America means L2 in Europe. On the Panel Drain, the black color is visible on the connector face that protrudes from the enclosure panel. When multiple PowerFit connectors are mounted side by side in a distribution box, the color-coded faces create a clear visual map of the phase layout for incoming connections. Cross-convention errors between NEC-L1-black and IEC-L2-black are among the most common phase identification mistakes on international projects.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications make PFPD-2BK suitable for permanent installation?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2BK is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. For permanent installations, the IP 2X finger protection prevents accidental contact with live parts when the connector face is exposed, and the four-point flange mount exceeds mechanical retention requirements.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPD-2BK installed in a power distribution enclosure?\u003c\/h3\u003e\n    \u003cp\u003eInstalling PFPD-2BK requires a 42 x 42mm cutout in the enclosure panel. The connector mounts through four 5.5mm fixing holes on its flange, distributing clamping force evenly for vibration resistance. The M12 threaded post accepts the brass nut and washer, tightened to a maximum of 12 to 14 N\/m. IP 2X finger protection is built into the connector face, preventing accidental contact with live parts when no mating connector is inserted. A plastic end cap protects the contacts during storage and transport. The Panel Drain has a 55.0mm flange width and 72.2mm total depth, with a 37.0mm body diameter. The flange provides a generous mounting surface for secure enclosure attachment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat sets PFPD-2BK apart from conventional panel-mount power connectors?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2BK offers several meaningful improvements over conventional single-pole power connectors: IP 2X finger protection prevents accidental contact with live parts when the connector face is exposed; IP67 protection when mated provides dust-tight and waterproof sealing that most single-pole connectors lack; the 1000V AC \/ 1500V DC voltage rating exceeds the typical 600V maximum of traditional alternatives; silver-plated brass contacts deliver lower contact resistance (0.1 milliohms) than plain brass. These features, combined with TUV Rheinland certification and the phase-encoded black housing for L2 identification, make PowerFit a generation ahead of traditional designs.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What kind of installations require PFPD-2BK?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2BK is a KUPO PowerFit 400A panel drain connector with a black housing, identifying Line 2 (L2) under Europe and UK (IEC 60446) conventions. Mounted permanently in enclosures and distribution boxes, it serves as the final destination in the PowerFit electric direction flow, where incoming power from Line Source connectors enters the downstream equipment. The four-point flange mount and M12 threaded post ensure vibration-resistant installation. It is commonly deployed in industrial manufacturing plant applications. Temporary power in manufacturing environments faces vibration from heavy machinery, exposure to oils and cutting fluids, and the need for high current capacity to feed welders, presses, and large motors.\"}}, {\"@type\": \"Question\", \"name\": \"What are the electrical specifications of PFPD-2BK for panel installations?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2BK is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for L2 circuits carrying continuous phase current.\"}}, {\"@type\": \"Question\", \"name\": \"How does the black color coding on PFPD-2BK help identify L2 on the jobsite?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Under IEC 60446, black identifies Line 2 (L2). This is the second phase conductor in the European three-phase system of brown (L1), black (L2), grey (L3). For international crews, this is a critical distinction: the same black housing that means L1 in North America means L2 in Europe. On the Panel Drain, the black color is visible on the connector face that protrudes from the enclosure panel. When multiple PowerFit connectors are mounted side by side in a distribution box, the color-coded faces create a clear visual map of the phase layout for incoming connections. Cross-convention errors between NEC-L1-black and IEC-L2-black are among the most common phase identification mistakes on international projects.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications make PFPD-2BK suitable for permanent installation?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2BK is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. For permanent installations, the IP 2X finger protection prevents accidental contact with live parts when the connector face is exposed, and the four-point flange mount exceeds mechanical retention requirements.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPD-2BK installed in a power distribution enclosure?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Installing PFPD-2BK requires a 42 x 42mm cutout in the enclosure panel. The connector mounts through four 5.5mm fixing holes on its flange, distributing clamping force evenly for vibration resistance. The M12 threaded post accepts the brass nut and washer, tightened to a maximum of 12 to 14 N\/m. IP 2X finger protection is built into the connector face, preventing accidental contact with live parts when no mating connector is inserted. A plastic end cap protects the contacts during storage and transport. The Panel Drain has a 55.0mm flange width and 72.2mm total depth, with a 37.0mm body diameter. The flange provides a generous mounting surface for secure enclosure attachment.\"}}, {\"@type\": \"Question\", \"name\": \"What sets PFPD-2BK apart from conventional panel-mount power connectors?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2BK offers several meaningful improvements over conventional single-pole power connectors: IP 2X finger protection prevents accidental contact with live parts when the connector face is exposed; IP67 protection when mated provides dust-tight and waterproof sealing that most single-pole connectors lack; the 1000V AC \/ 1500V DC voltage rating exceeds the typical 600V maximum of traditional alternatives; silver-plated brass contacts deliver lower contact resistance (0.1 milliohms) than plain brass. These features, combined with TUV Rheinland certification and the phase-encoded black housing for L2 identification, make PowerFit a generation ahead of traditional designs.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPD-2BK\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPD-2BK.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPD-2BK Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 400A \/ Panel Mount Receptacle","offer_id":50208844054748,"sku":"PFPD-2BK","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPD-2BK-b.jpg?v=1777364459"},{"product_id":"pfpd-2r","title":"PFPD-2R - PowerFit 400A Drain Panel Connector, Red (L2)","description":"\u003c!-- Combined Shopify product HTML for PFPD-2R --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPD-2R\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Panel Drain Connector (Red) | PFPD-2R | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPD-2R\" data-color=\"Red\"\u003e\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eFilm and television production facilities operating under North American electrical code standards require permanent power infrastructure that delivers 400A across secondary phase circuits to lighting rigs, camera equipment systems, and support infrastructure mounted in outdoor stages and soundstage electrical rooms. The PowerFit 400A Panel Drain connector in red (Phase 2 \/ L2 NEC) provides the enclosure-mount architecture for secondary phase distribution in production facility switchboards, enabling rapid reconfiguration during multi-day shoot schedules while maintaining the structural integrity demanded by UL94-V0 rated thermoplastic construction. The patent key-release pin simplifies hot-swap maintenance operations, while the plastic end cap prevents accidental contact with live electrical surfaces during crowded equipment bay work.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003e400A continuous current rating at 120mm² cable; 660A at 240mm² cable for multi-rig film production distribution\u003c\/li\u003e\n      \u003cli\u003eFemale contact design ensures reliable mating with Panel Source connectors across consecutive shoot days\u003c\/li\u003e\n      \u003cli\u003eM12 threaded post with brass nut and spring washer provides secure fastening in soundstage cabinet installations\u003c\/li\u003e\n      \u003cli\u003eFour diameter 5.5mm fixing holes (42mm  x  42mm cut-out) accommodate standard North American electrical cabinet frames\u003c\/li\u003e\n      \u003cli\u003ePatent key-release pin enables production electricians to safely disconnect feeds between take configurations without tools\u003c\/li\u003e\n      \u003cli\u003ePlastic end cap over female contact provides IP 2X finger protection in high-traffic production cable management areas\u003c\/li\u003e\n      \u003cli\u003ePush-and-twist locking mechanism resists accidental separation from equipment movement and vibration\u003c\/li\u003e\n      \u003cli\u003eSilver-plated brass contact delivers 0.1 milliohms contact resistance, minimizing voltage drop across extensive grid lighting systems\u003c\/li\u003e\n      \u003cli\u003eNon-conductive UL94-V0 thermoplastic housing meets North American motion picture safety standards\u003c\/li\u003e\n      \u003cli\u003eIP67 rating while mated provides protection against water ingress from outdoor weather conditions and studio spray cooling systems\u003c\/li\u003e\n      \u003cli\u003eMaximum nut torque: 12 to 14 N\/meter ensures secure mounting without risk of rework during shoot schedules\u003c\/li\u003e\n      \u003cli\u003eRed color codes as Phase 2 (L2) under NEC, providing standard phase identification for North American production crews\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eTÜV Rheinland certified (ID 1111303479) for North American production facility electrical systems\u003c\/li\u003e\n      \u003cli\u003eCE marking for international production equipment certification\u003c\/li\u003e\n      \u003cli\u003eRoHS and REACH compliant for environmental responsibility in production operations\u003c\/li\u003e\n      \u003cli\u003eUL94-V0 flame retardancy rating for motion picture safety standards\u003c\/li\u003e\n      \u003cli\u003eIP67 rating (dust-tight, submersion-resistant) suitable for outdoor stage and studio installations\u003c\/li\u003e\n      \u003cli\u003e1000V AC \/ 1500V DC maximum operating voltage; 4500V AC dielectric test\u003c\/li\u003e\n      \u003cli\u003eShort circuit rating: Up to 35.5kA; insulation resistance greater than 5000 megohms at 500V AC\u003c\/li\u003e\n      \u003cli\u003eWorking temperature range: 45 to 85 degrees Celsius - stable across production facility temperature control ranges\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eFilm and television soundstage permanent switchboard installations serving multiple lighting and power grids\u003c\/li\u003e\n      \u003cli\u003eOutdoor stage power distribution enclosures for concert touring and event production facilities\u003c\/li\u003e\n      \u003cli\u003eProduction support equipment distribution (air conditioning, water systems, safety equipment) in production villages\u003c\/li\u003e\n      \u003cli\u003eCamera truck and mobile production facility power interconnection systems\u003c\/li\u003e\n      \u003cli\u003eLighting truck trailer permanent power distribution panels for multi-camera field shoots\u003c\/li\u003e\n      \u003cli\u003eStudio generator paralleling switchboards for seamless power backup during live broadcast productions\u003c\/li\u003e\n      \u003cli\u003ePost-production facility power management for editing suites and audio mixing systems\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe PowerFit 400A Panel Drain connector is compatible with major brands of single-pole power connector systems used in North American film and television production infrastructure. Its M12 threaded post interface and push-and-twist mating mechanism follow standardized connection geometry across certified suppliers. Verify that your Panel Source connector carries production-grade certifications and matches your facility power specifications. The color-coded red housing complies with NEC phase identification standards used throughout North American motion picture and broadcast industry electrical systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPD-2R | PowerFit 400A Panel Drain, L2 (Phase B) Red (NEC - North American)\",\n  \"description\": \"KUPO PowerFit 400A Panel Drain single-pole connector with red housing for NEC - North American power distribution systems. Female Contact, M12 threaded post mount, IP67 rated when mated, silver-plated brass contacts, dual-rated 400A\/660A, 1000V AC \/ 1500V DC maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Panel-Mount Connectors \u003e PowerFit\",\n  \"sku\": \"PFPD-2R\",\n  \"mpn\": \"PFPD-2R\",\n  \"color\": \"Red\",\n  \"material\": \"Non-conductive thermoplastic housing; Brass silver-plated contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC \/ 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A continuous (120mm\u0026sup2; cable) \/ 660A continuous (240mm\u0026sup2; cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5 kiloamperes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Drain (Female Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-Twist Lock\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mounting Type\",\n      \"value\": \"Panel Mount with M12 Threaded Post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fixing Holes\",\n      \"value\": \"Four diameter 5.5mm holes; 42mm x 42mm cut-out dimension\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fastener Material\",\n      \"value\": \"Brass nut and spring washer\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Maximum Nut Torque\",\n      \"value\": \"12 to 14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated; IP 2X finger protection\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"TUV Certification ID\",\n      \"value\": \"1111303479\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV Rheinland, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 (Phase B) (NEC - North American)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Red\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPD-2R\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is PFPD-2R and where is it permanently installed?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2R is a KUPO PowerFit 400A panel drain connector with a red housing, identifying Line 2 (L2) under North America (NEC) conventions. Mounted permanently in enclosures and distribution boxes, it serves as the final destination in the PowerFit electric direction flow, where incoming power from Line Source connectors enters the downstream equipment. The four-point flange mount and M12 threaded post ensure vibration-resistant installation. It is commonly deployed in construction site applications. Construction power distribution deals with dust, debris, rain, rough handling by crews, and the constant repositioning of equipment as the site evolves.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat current and voltage ratings make PFPD-2R suitable for permanent distribution?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2R is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The insulation resistance exceeds 5000 megaohms at 500V AC, and the test voltage rating of 4500V AC provides substantial safety margin. The short circuit rating of up to 35.5 kiloamperes means the connector can withstand fault conditions without catastrophic failure.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does the red color coding on PFPD-2R help identify L2 on the jobsite?\u003c\/h3\u003e\n    \u003cp\u003eRed marks Line 2 (L2) under North American NEC conventions. In a standard three-phase system, the color sequence is black (L1), red (L2), blue (L3). Red L2 is one of the most commonly ordered phase variants for US and Canadian power distribution, appearing in virtually every multi-phase temporary power installation. On the Panel Drain, the red color is visible on the connector face that protrudes from the enclosure panel. When multiple PowerFit connectors are mounted side by side in a distribution box, the color-coded faces create a clear visual map of the phase layout for incoming connections. Red is one of the most visually distinctive colors on a busy event site, helping crews quickly trace the second phase conductor even from a distance.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does PFPD-2R meet safety requirements for panel-mounted power distribution?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2R is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. For permanent installations, the IP 2X finger protection prevents accidental contact with live parts when the connector face is exposed, and the four-point flange mount exceeds mechanical retention requirements.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eCan PFPD-2R work alongside connectors from other brands in a distribution panel?\u003c\/h3\u003e\n    \u003cp\u003ePowerFit connectors are designed to be compatible with major brands of single-pole power connector. The high-impact thermoplastic housing absorbs punishment, the IP67 seal protects against dust ingress (the '6' in IP67 means dust-tight), and the M40 cable gland secures cables against pull-out. For L2 circuits using North America (NEC) color conventions, the red PFPD-2R ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat are the mounting requirements for PFPD-2R in a panel?\u003c\/h3\u003e\n    \u003cp\u003eInstalling PFPD-2R requires a 42 x 42mm cutout in the enclosure panel. The connector mounts through four 5.5mm fixing holes on its flange, distributing clamping force evenly for vibration resistance. The M12 threaded post accepts the brass nut and washer, tightened to a maximum of 12 to 14 N\/m. IP 2X finger protection is built into the connector face, preventing accidental contact with live parts when no mating connector is inserted. A plastic end cap protects the contacts during storage and transport. The Panel Drain has a 55.0mm flange width and 72.2mm total depth, with a 37.0mm body diameter. The flange provides a generous mounting surface for secure enclosure attachment.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is PFPD-2R and where is it permanently installed?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2R is a KUPO PowerFit 400A panel drain connector with a red housing, identifying Line 2 (L2) under North America (NEC) conventions. Mounted permanently in enclosures and distribution boxes, it serves as the final destination in the PowerFit electric direction flow, where incoming power from Line Source connectors enters the downstream equipment. The four-point flange mount and M12 threaded post ensure vibration-resistant installation. It is commonly deployed in construction site applications. Construction power distribution deals with dust, debris, rain, rough handling by crews, and the constant repositioning of equipment as the site evolves.\"}}, {\"@type\": \"Question\", \"name\": \"What current and voltage ratings make PFPD-2R suitable for permanent distribution?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2R is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The insulation resistance exceeds 5000 megaohms at 500V AC, and the test voltage rating of 4500V AC provides substantial safety margin. The short circuit rating of up to 35.5 kiloamperes means the connector can withstand fault conditions without catastrophic failure.\"}}, {\"@type\": \"Question\", \"name\": \"How does the red color coding on PFPD-2R help identify L2 on the jobsite?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Red marks Line 2 (L2) under North American NEC conventions. In a standard three-phase system, the color sequence is black (L1), red (L2), blue (L3). Red L2 is one of the most commonly ordered phase variants for US and Canadian power distribution, appearing in virtually every multi-phase temporary power installation. On the Panel Drain, the red color is visible on the connector face that protrudes from the enclosure panel. When multiple PowerFit connectors are mounted side by side in a distribution box, the color-coded faces create a clear visual map of the phase layout for incoming connections. Red is one of the most visually distinctive colors on a busy event site, helping crews quickly trace the second phase conductor even from a distance.\"}}, {\"@type\": \"Question\", \"name\": \"How does PFPD-2R meet safety requirements for panel-mounted power distribution?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2R is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. For permanent installations, the IP 2X finger protection prevents accidental contact with live parts when the connector face is exposed, and the four-point flange mount exceeds mechanical retention requirements.\"}}, {\"@type\": \"Question\", \"name\": \"Can PFPD-2R work alongside connectors from other brands in a distribution panel?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PowerFit connectors are designed to be compatible with major brands of single-pole power connector. The high-impact thermoplastic housing absorbs punishment, the IP67 seal protects against dust ingress (the '6' in IP67 means dust-tight), and the M40 cable gland secures cables against pull-out. For L2 circuits using North America (NEC) color conventions, the red PFPD-2R ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\"}}, {\"@type\": \"Question\", \"name\": \"What are the mounting requirements for PFPD-2R in a panel?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Installing PFPD-2R requires a 42 x 42mm cutout in the enclosure panel. The connector mounts through four 5.5mm fixing holes on its flange, distributing clamping force evenly for vibration resistance. The M12 threaded post accepts the brass nut and washer, tightened to a maximum of 12 to 14 N\/m. IP 2X finger protection is built into the connector face, preventing accidental contact with live parts when no mating connector is inserted. A plastic end cap protects the contacts during storage and transport. The Panel Drain has a 55.0mm flange width and 72.2mm total depth, with a 37.0mm body diameter. The flange provides a generous mounting surface for secure enclosure attachment.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPD-2R\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPD-2R.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPD-2R Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 400A \/ Panel Mount Receptacle","offer_id":50208844087516,"sku":"PFPD-2R","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPD-2R.jpg?v=1777364461"},{"product_id":"pfpd-2w","title":"PFPD-2W - PowerFit 400A Drain Panel Connector, White (L2)","description":"\u003c!-- Combined Shopify product HTML for PFPD-2W --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPD-2W\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Panel Drain Connector (White) | PFPD-2W | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPD-2W\" data-color=\"White\"\u003e\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eAustralian renewable energy installations delivering wind power from remote coastal turbine farms to mainland grid distribution centers depend on permanent electrical interconnection infrastructure that maintains 400A continuous current under extreme environmental stress. The PowerFit 400A Panel Drain connector in white (Phase 2 \/ L2 Australia) provides the enclosure-mount architecture for secondary phase distribution in wind farm metering cabinets, substation switchboards, and point-of-common-coupling (PCC) control rooms, ensuring color-coded compliance with Australian electrical standards (AS\/NZS 3000). The innovative plastic end cap protects live electrical surfaces from accidental contact in wind farm control rooms, while the patent key-release pin simplifies tool-free disconnection during equipment maintenance windows.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003e400A continuous current rating at 120mm² cable; 660A at 240mm² cable for large-scale renewable energy delivery\u003c\/li\u003e\n      \u003cli\u003eFemale contact design ensures reliable mating with Panel Source connectors in wind farm electrical infrastructure\u003c\/li\u003e\n      \u003cli\u003eM12 threaded post with brass nut and spring washer provides secure fastening in coastal salt-air environments\u003c\/li\u003e\n      \u003cli\u003eFour diameter 5.5mm fixing holes (42mm  x  42mm cut-out) accommodate Australian electrical cabinet frame standards\u003c\/li\u003e\n      \u003cli\u003ePatent key-release pin enables renewable energy technicians to safely disconnect feeds without mechanical tools\u003c\/li\u003e\n      \u003cli\u003ePlastic end cap over female contact provides IP 2X finger protection in high-altitude wind farm installation conditions\u003c\/li\u003e\n      \u003cli\u003ePush-and-twist locking mechanism resists vibration from wind turbine and generator equipment operation\u003c\/li\u003e\n      \u003cli\u003eSilver-plated brass contact delivers 0.1 milliohms contact resistance across megawatt-scale power transmission\u003c\/li\u003e\n      \u003cli\u003eNon-conductive UL94-V0 thermoplastic housing meets Australian electrical safety standards for renewable installations\u003c\/li\u003e\n      \u003cli\u003eIP67 rating while mated protects against salt spray and moisture ingress from coastal wind farm locations\u003c\/li\u003e\n      \u003cli\u003eMaximum nut torque: 12 to 14 N\/meter ensures secure mounting in harsh coastal weather conditions\u003c\/li\u003e\n      \u003cli\u003eWhite color codes as Phase 2 (L2) under Australian electrical standards (AS\/NZS 3000)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eTÜV Rheinland certified (ID 1111303479) for global renewable energy infrastructure compliance\u003c\/li\u003e\n      \u003cli\u003eCE marking for international renewable energy equipment certification\u003c\/li\u003e\n      \u003cli\u003eRoHS and REACH compliant for environmental sustainability in renewable installations\u003c\/li\u003e\n      \u003cli\u003eUL94-V0 flame retardancy rating for wind farm electrical safety\u003c\/li\u003e\n      \u003cli\u003eIP67 rating (dust-tight, submersion-resistant) suitable for coastal wind farm installations\u003c\/li\u003e\n      \u003cli\u003e1000V AC \/ 1500V DC maximum operating voltage; 4500V AC dielectric test\u003c\/li\u003e\n      \u003cli\u003eShort circuit rating: Up to 35.5kA; insulation resistance greater than 5000 megohms at 500V AC\u003c\/li\u003e\n      \u003cli\u003eWorking temperature range: 45 to 85 degrees Celsius - stable across Australian tropical and temperate zones\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eOffshore and onshore wind farm metering and protection cabinet installations\u003c\/li\u003e\n      \u003cli\u003eSolar array inverter distribution panels for utility-scale photovoltaic installations\u003c\/li\u003e\n      \u003cli\u003eBattery energy storage system (BESS) interconnection for grid stabilization services\u003c\/li\u003e\n      \u003cli\u003ePoint-of-common-coupling (PCC) switchboards at renewable generation facilities\u003c\/li\u003e\n      \u003cli\u003eSubstation step-up transformer secondary distribution for renewable power export\u003c\/li\u003e\n      \u003cli\u003eMicrogrid and virtual power plant electrical infrastructure in rural and remote regions\u003c\/li\u003e\n      \u003cli\u003eRenewable energy hybrid systems combining wind, solar, and hydroelectric generation\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe PowerFit 400A Panel Drain connector is compatible with major brands of single-pole power connector systems used in Australian renewable energy installations. Its M12 threaded post interface and push-and-twist mating mechanism follow standardized connection geometry across certified suppliers. Verify that your Panel Source connector carries renewable-grade certifications (salt-spray testing, UV resistance) and matches your facility voltage and amperage specifications. The color-coded white housing complies with AS\/NZS 3000 phase identification standards used throughout Australian renewable energy infrastructure.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPD-2W | PowerFit 400A Panel Drain, L2 (Phase B) White (Australian)\",\n  \"description\": \"KUPO PowerFit 400A Panel Drain single-pole connector with white housing for Australian power distribution systems. Female Contact, M12 threaded post mount, IP67 rated when mated, silver-plated brass contacts, dual-rated 400A\/660A, 1000V AC \/ 1500V DC maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Panel-Mount Connectors \u003e PowerFit\",\n  \"sku\": \"PFPD-2W\",\n  \"mpn\": \"PFPD-2W\",\n  \"color\": \"White\",\n  \"material\": \"Non-conductive thermoplastic housing; Brass silver-plated contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC \/ 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A continuous (120mm\u0026sup2; cable) \/ 660A continuous (240mm\u0026sup2; cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5 kiloamperes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Drain (Female Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-Twist Lock\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mounting Type\",\n      \"value\": \"Panel Mount with M12 Threaded Post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fixing Holes\",\n      \"value\": \"Four diameter 5.5mm holes; 42mm x 42mm cut-out dimension\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fastener Material\",\n      \"value\": \"Brass nut and spring washer\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Maximum Nut Torque\",\n      \"value\": \"12 to 14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated; IP 2X finger protection\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"TUV Certification ID\",\n      \"value\": \"1111303479\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV Rheinland, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 (Phase B) (Australian)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"White\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPD-2W\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat role does PFPD-2W serve in a power distribution enclosure?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2W is a KUPO PowerFit 400A panel drain connector with a white housing, identifying Line 2 (L2) under Australia conventions. Mounted permanently in enclosures and distribution boxes, it serves as the final destination in the PowerFit electric direction flow, where incoming power from Line Source connectors enters the downstream equipment. The four-point flange mount and M12 threaded post ensure vibration-resistant installation. It is commonly deployed in marine and shipyard applications. Shipyard and dockside power connections face salt spray, high humidity, and the corrosive marine environment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does PFPD-2W handle the electrical demands of fixed power distribution?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2W is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The M12 threaded post termination accepts conductors through a brass nut and washer assembly, tightened to a maximum of 12 to 14 N\/m. The four-point flange mount with 5.5mm fixing holes distributes mechanical load across the panel surface.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does the white color coding on PFPD-2W help identify L2 on the jobsite?\u003c\/h3\u003e\n    \u003cp\u003eWhite as L2 follows Australian wiring conventions, where the three-phase set is red (L1), white (L2), blue (L3). This variant specifically serves Australian, New Zealand, and related Asia-Pacific markets. On the Panel Drain, the white color is visible on the connector face that protrudes from the enclosure panel. When multiple PowerFit connectors are mounted side by side in a distribution box, the color-coded faces create a clear visual map of the phase layout for incoming connections. The stark visual contrast between white L2 and the darker L1\/L3 conductors makes phase tracing straightforward in Australian installations.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat regulatory approvals does PFPD-2W hold for fixed installations?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2W is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. For permanent installations, the IP 2X finger protection prevents accidental contact with live parts when the connector face is exposed, and the four-point flange mount exceeds mechanical retention requirements.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat panel preparation does PFPD-2W require for permanent installation?\u003c\/h3\u003e\n    \u003cp\u003eInstalling PFPD-2W requires a 42 x 42mm cutout in the enclosure panel. The connector mounts through four 5.5mm fixing holes on its flange, distributing clamping force evenly for vibration resistance. The M12 threaded post accepts the brass nut and washer, tightened to a maximum of 12 to 14 N\/m. IP 2X finger protection is built into the connector face, preventing accidental contact with live parts when no mating connector is inserted. A plastic end cap protects the contacts during storage and transport. The Panel Drain has a 55.0mm flange width and 72.2mm total depth, with a 37.0mm body diameter. The flange provides a generous mounting surface for secure enclosure attachment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does PFPD-2W integrate with existing power infrastructure in marine and shipyard settings?\u003c\/h3\u003e\n    \u003cp\u003ePowerFit connectors are designed to be compatible with major brands of single-pole power connector. Silver-plated brass contacts resist corrosion far better than plain brass, the silicone O-ring maintains IP67 sealing in high-humidity conditions, and the non-conductive thermoplastic housing is impervious to salt corrosion. For L2 circuits using Australia color conventions, the white PFPD-2W ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What role does PFPD-2W serve in a power distribution enclosure?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2W is a KUPO PowerFit 400A panel drain connector with a white housing, identifying Line 2 (L2) under Australia conventions. Mounted permanently in enclosures and distribution boxes, it serves as the final destination in the PowerFit electric direction flow, where incoming power from Line Source connectors enters the downstream equipment. The four-point flange mount and M12 threaded post ensure vibration-resistant installation. It is commonly deployed in marine and shipyard applications. Shipyard and dockside power connections face salt spray, high humidity, and the corrosive marine environment.\"}}, {\"@type\": \"Question\", \"name\": \"How does PFPD-2W handle the electrical demands of fixed power distribution?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2W is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The M12 threaded post termination accepts conductors through a brass nut and washer assembly, tightened to a maximum of 12 to 14 N\/m. The four-point flange mount with 5.5mm fixing holes distributes mechanical load across the panel surface.\"}}, {\"@type\": \"Question\", \"name\": \"How does the white color coding on PFPD-2W help identify L2 on the jobsite?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"White as L2 follows Australian wiring conventions, where the three-phase set is red (L1), white (L2), blue (L3). This variant specifically serves Australian, New Zealand, and related Asia-Pacific markets. On the Panel Drain, the white color is visible on the connector face that protrudes from the enclosure panel. When multiple PowerFit connectors are mounted side by side in a distribution box, the color-coded faces create a clear visual map of the phase layout for incoming connections. The stark visual contrast between white L2 and the darker L1\/L3 conductors makes phase tracing straightforward in Australian installations.\"}}, {\"@type\": \"Question\", \"name\": \"What regulatory approvals does PFPD-2W hold for fixed installations?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2W is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. For permanent installations, the IP 2X finger protection prevents accidental contact with live parts when the connector face is exposed, and the four-point flange mount exceeds mechanical retention requirements.\"}}, {\"@type\": \"Question\", \"name\": \"What panel preparation does PFPD-2W require for permanent installation?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Installing PFPD-2W requires a 42 x 42mm cutout in the enclosure panel. The connector mounts through four 5.5mm fixing holes on its flange, distributing clamping force evenly for vibration resistance. The M12 threaded post accepts the brass nut and washer, tightened to a maximum of 12 to 14 N\/m. IP 2X finger protection is built into the connector face, preventing accidental contact with live parts when no mating connector is inserted. A plastic end cap protects the contacts during storage and transport. The Panel Drain has a 55.0mm flange width and 72.2mm total depth, with a 37.0mm body diameter. The flange provides a generous mounting surface for secure enclosure attachment.\"}}, {\"@type\": \"Question\", \"name\": \"How does PFPD-2W integrate with existing power infrastructure in marine and shipyard settings?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PowerFit connectors are designed to be compatible with major brands of single-pole power connector. Silver-plated brass contacts resist corrosion far better than plain brass, the silicone O-ring maintains IP67 sealing in high-humidity conditions, and the non-conductive thermoplastic housing is impervious to salt corrosion. For L2 circuits using Australia color conventions, the white PFPD-2W ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPD-2W\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPD-2W.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPD-2W Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 400A \/ Panel Mount Receptacle","offer_id":50208844120284,"sku":"PFPD-2W","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPD-2W-b.jpg?v=1777364461"},{"product_id":"pfpd-2y","title":"PFPD-2Y - PowerFit 400A Drain Panel Connector, Yellow (L2)","description":"\u003c!-- Combined Shopify product HTML for PFPD-2Y --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPD-2Y\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Panel Drain Connector (Yellow) | PFPD-2Y | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPD-2Y\" data-color=\"Yellow\"\u003e\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eUnited Kingdom electrical infrastructure using legacy color-coding standards requires permanent power distribution connectors that maintain backward compatibility with historical wiring conventions while delivering modern safety and reliability. The PowerFit 400A Panel Drain connector in yellow (Phase 2 \/ L2 UK Old) provides the enclosure-mount architecture for secondary phase distribution in UK industrial facilities, heritage buildings, and heritage electrical systems transitioning to modern standards. Operating at 400A continuous with silver-plated brass contacts rated for 500 mating cycles, this connector bridges the gap between older UK electrical conventions and current European IEC standards, offering the patent key-release pin for safe disconnection and plastic end cap protection against incidental contact with live electrical surfaces.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003e400A continuous current rating at 120mm² cable; 660A at 240mm² cable for multi-phase UK distribution systems\u003c\/li\u003e\n      \u003cli\u003eFemale contact design ensures secure mating with Panel Source connectors in heritage and modern UK electrical rooms\u003c\/li\u003e\n      \u003cli\u003eM12 threaded post with brass nut and spring washer provides secure fastening in UK electrical cabinet standards\u003c\/li\u003e\n      \u003cli\u003eFour diameter 5.5mm fixing holes (42mm  x  42mm cut-out) accommodate UK electrical equipment mounting frames\u003c\/li\u003e\n      \u003cli\u003ePatent key-release pin enables UK technicians to safely disconnect secondary phase feeds without additional tools\u003c\/li\u003e\n      \u003cli\u003ePlastic end cap over female contact provides IP 2X finger protection in high-density industrial electrical rooms\u003c\/li\u003e\n      \u003cli\u003ePush-and-twist locking mechanism prevents vibration-induced separation in operating machinery environments\u003c\/li\u003e\n      \u003cli\u003eSilver-plated brass contact delivers 0.1 milliohms contact resistance across continuous UK industrial power cycles\u003c\/li\u003e\n      \u003cli\u003eNon-conductive UL94-V0 thermoplastic housing meets UK electrical safety standards for heritage and modern installations\u003c\/li\u003e\n      \u003cli\u003eIP67 rating while mated protects against moisture and dust ingress from UK industrial facility conditions\u003c\/li\u003e\n      \u003cli\u003eMaximum nut torque: 12 to 14 N\/meter ensures secure mounting without risk of rework\u003c\/li\u003e\n      \u003cli\u003eYellow color codes as Phase 2 (L2) under older UK wiring regulations (BS 7671 pre-2006)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eTÜV Rheinland certified (ID 1111303479) for UK industrial electrical system compliance\u003c\/li\u003e\n      \u003cli\u003eCE marking for European distribution through UK market channels\u003c\/li\u003e\n      \u003cli\u003eRoHS and REACH compliant for UK environmental responsibility standards\u003c\/li\u003e\n      \u003cli\u003eUL94-V0 flame retardancy rating for industrial safety\u003c\/li\u003e\n      \u003cli\u003eIP67 rating (dust-tight, submersion-resistant) suitable for UK industrial installations\u003c\/li\u003e\n      \u003cli\u003e1000V AC \/ 1500V DC maximum operating voltage; 4500V AC dielectric test\u003c\/li\u003e\n      \u003cli\u003eShort circuit rating: Up to 35.5kA; insulation resistance greater than 5000 megohms at 500V AC\u003c\/li\u003e\n      \u003cli\u003eWorking temperature range: 45 to 85 degrees Celsius - stable across UK temperate climate conditions\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eUK industrial plant electrical distribution systems using legacy color-coding conventions\u003c\/li\u003e\n      \u003cli\u003eHeritage building electrical infrastructure retrofits maintaining older UK wiring standards\u003c\/li\u003e\n      \u003cli\u003eManufacturing facilities transitioning from older to modern UK electrical standards\u003c\/li\u003e\n      \u003cli\u003eIndustrial machinery control cabinet distribution for UK-based operations\u003c\/li\u003e\n      \u003cli\u003eRailway infrastructure and station electrical distribution systems using UK standards\u003c\/li\u003e\n      \u003cli\u003eHospital and medical facility electrical systems with established UK color-coding\u003c\/li\u003e\n      \u003cli\u003eMuseum and cultural heritage site electrical system maintenance and upgrade projects\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe PowerFit 400A Panel Drain connector is compatible with major brands of single-pole power connector systems used in UK industrial and heritage electrical infrastructure. Its M12 threaded post interface and push-and-twist mating mechanism follow standardized connection geometry across certified suppliers. Verify that your Panel Source connector carries UK certifications and is rated for legacy or modern color-coding standards. The yellow color housing complies with older UK wiring regulations (BS 7671 pre-2006) and facilitates transition planning to modern IEC 60446 standards.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPD-2Y | PowerFit 400A Panel Drain, L2 (Phase B) Yellow (UK (Old Standard))\",\n  \"description\": \"KUPO PowerFit 400A Panel Drain single-pole connector with yellow housing for UK (Old Standard) power distribution systems. Female Contact, M12 threaded post mount, IP67 rated when mated, silver-plated brass contacts, dual-rated 400A\/660A, 1000V AC \/ 1500V DC maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Panel-Mount Connectors \u003e PowerFit\",\n  \"sku\": \"PFPD-2Y\",\n  \"mpn\": \"PFPD-2Y\",\n  \"color\": \"Yellow\",\n  \"material\": \"Non-conductive thermoplastic housing; Brass silver-plated contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC \/ 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A continuous (120mm\u0026sup2; cable) \/ 660A continuous (240mm\u0026sup2; cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5 kiloamperes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Drain (Female Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-Twist Lock\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mounting Type\",\n      \"value\": \"Panel Mount with M12 Threaded Post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fixing Holes\",\n      \"value\": \"Four diameter 5.5mm holes; 42mm x 42mm cut-out dimension\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fastener Material\",\n      \"value\": \"Brass nut and spring washer\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Maximum Nut Torque\",\n      \"value\": \"12 to 14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated; IP 2X finger protection\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"TUV Certification ID\",\n      \"value\": \"1111303479\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV Rheinland, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 (Phase B) (UK (Old Standard))\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Yellow\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPD-2Y\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does PFPD-2Y function as the endpoint of a PowerFit power chain?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2Y is a KUPO PowerFit 400A panel drain connector with a yellow housing, identifying Line 2 (L2) under UK (Old, pre-2004) conventions. Mounted permanently in enclosures and distribution boxes, it serves as the final destination in the PowerFit electric direction flow, where incoming power from Line Source connectors enters the downstream equipment. The four-point flange mount and M12 threaded post ensure vibration-resistant installation. It is commonly deployed in data center maintenance applications. During data center expansion or maintenance windows, temporary power must be distributed with absolute reliability.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat are the electrical specifications of PFPD-2Y for panel installations?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2Y is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for L2 circuits carrying continuous phase current.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does the yellow color coding on PFPD-2Y help identify L2 on the jobsite?\u003c\/h3\u003e\n    \u003cp\u003eYellow identifies L2 under the legacy UK wiring color code (red\/yellow\/blue for L1\/L2\/L3) used before the 2004 harmonization to IEC standards. Legacy UK installations, some Commonwealth countries, and specialty applications still use this color scheme. On the Panel Drain, the yellow color is visible on the connector face that protrudes from the enclosure panel. When multiple PowerFit connectors are mounted side by side in a distribution box, the color-coded faces create a clear visual map of the phase layout for incoming connections. When maintaining or extending pre-2004 UK installations, matching the existing yellow L2 convention prevents confusion between old and new color systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications make PFPD-2Y suitable for permanent installation?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2Y is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. For permanent installations, the IP 2X finger protection prevents accidental contact with live parts when the connector face is exposed, and the four-point flange mount exceeds mechanical retention requirements.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat equipment and enclosures is PFPD-2Y designed to mount in?\u003c\/h3\u003e\n    \u003cp\u003ePowerFit connectors are designed to be compatible with major brands of single-pole power connector. The 0.1 milliohm contact resistance minimizes heat generation at connection points, the 500-cycle mating rating supports repeated connect\/disconnect during maintenance, and the 1000V AC \/ 1500V DC rating provides margin for high-voltage DC distribution architectures. For L2 circuits using UK (Old, pre-2004) color conventions, the yellow PFPD-2Y ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"How does PFPD-2Y function as the endpoint of a PowerFit power chain?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2Y is a KUPO PowerFit 400A panel drain connector with a yellow housing, identifying Line 2 (L2) under UK (Old, pre-2004) conventions. Mounted permanently in enclosures and distribution boxes, it serves as the final destination in the PowerFit electric direction flow, where incoming power from Line Source connectors enters the downstream equipment. The four-point flange mount and M12 threaded post ensure vibration-resistant installation. It is commonly deployed in data center maintenance applications. During data center expansion or maintenance windows, temporary power must be distributed with absolute reliability.\"}}, {\"@type\": \"Question\", \"name\": \"What are the electrical specifications of PFPD-2Y for panel installations?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2Y is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for L2 circuits carrying continuous phase current.\"}}, {\"@type\": \"Question\", \"name\": \"How does the yellow color coding on PFPD-2Y help identify L2 on the jobsite?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yellow identifies L2 under the legacy UK wiring color code (red\/yellow\/blue for L1\/L2\/L3) used before the 2004 harmonization to IEC standards. Legacy UK installations, some Commonwealth countries, and specialty applications still use this color scheme. On the Panel Drain, the yellow color is visible on the connector face that protrudes from the enclosure panel. When multiple PowerFit connectors are mounted side by side in a distribution box, the color-coded faces create a clear visual map of the phase layout for incoming connections. When maintaining or extending pre-2004 UK installations, matching the existing yellow L2 convention prevents confusion between old and new color systems.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications make PFPD-2Y suitable for permanent installation?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2Y is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. For permanent installations, the IP 2X finger protection prevents accidental contact with live parts when the connector face is exposed, and the four-point flange mount exceeds mechanical retention requirements.\"}}, {\"@type\": \"Question\", \"name\": \"What equipment and enclosures is PFPD-2Y designed to mount in?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PowerFit connectors are designed to be compatible with major brands of single-pole power connector. The 0.1 milliohm contact resistance minimizes heat generation at connection points, the 500-cycle mating rating supports repeated connect\/disconnect during maintenance, and the 1000V AC \/ 1500V DC rating provides margin for high-voltage DC distribution architectures. For L2 circuits using UK (Old, pre-2004) color conventions, the yellow PFPD-2Y ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPD-2Y\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPD-2Y.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPD-2Y Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 400A \/ Panel Mount Receptacle","offer_id":50208844153052,"sku":"PFPD-2Y","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPD-2Y.jpg?v=1777364462"},{"product_id":"pfps-2bk","title":"PFPS-2BK - PowerFit 400A Source Panel Connector, Black (L2)","description":"\u003c!-- Combined Shopify product HTML for PFPS-2BK --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPS-2BK\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Panel Source Connector (Black) | PFPS-2BK | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPS-2BK\" data-color=\"Black\"\u003e\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThree-phase European installations using IEC standards assign black to the L2 (Phase B) conductor. The PowerFit 400A Panel Source in black for L2 service provides equipment manufacturers and panel builders with a high-current inlet that handles 400A continuous loads through silver-plated brass contacts, achieving just 0.1 milliohms contact resistance for efficient power transfer. The patent key-release pin mechanism prevents accidental disconnection under load while still allowing intentional tool-free release during scheduled maintenance, and the IP67 rating when mated protects against dust and water ingress in outdoor or washdown environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003e400A continuous current capacity at 120mm squared cable; 660A continuous at 240mm squared cable for heavy-duty applications\u003c\/li\u003e\n      \u003cli\u003eMale contact design provides the power source pin for mating with Line Drain or Panel Drain connectors\u003c\/li\u003e\n      \u003cli\u003ePatent key-release pin with POM (Polyoxymethylene) cotter pin enables tool-free disconnection without risking contact damage\u003c\/li\u003e\n      \u003cli\u003eM12 threaded post with brass nut and spring washer for permanent, vibration-resistant panel installation\u003c\/li\u003e\n      \u003cli\u003eFour diameter 5.5mm fixing holes on flange (42mm x 42mm cut-out dimension) ensure secure mechanical mounting\u003c\/li\u003e\n      \u003cli\u003ePlastic end cap over male contact provides IP 2X finger protection against electric shock when unmated\u003c\/li\u003e\n      \u003cli\u003ePush-and-twist locking mechanism maintains positive mechanical engagement across 500 rated mating cycles\u003c\/li\u003e\n      \u003cli\u003eBrass contact with silver plating delivers 0.1 milliohms contact resistance for minimal voltage drop and heat generation\u003c\/li\u003e\n      \u003cli\u003eNon-conductive thermoplastic housing rated UL94-V0 flame retardant for safety-critical installations\u003c\/li\u003e\n      \u003cli\u003eIP67 rating while connected ensures protection against water and dust ingress in outdoor or washdown environments\u003c\/li\u003e\n      \u003cli\u003e1000V AC \/ 1500V DC maximum voltage rating with 4500V AC dielectric test voltage for substantial safety margins\u003c\/li\u003e\n      \u003cli\u003eMaximum nut torque: 12 to 14 N\/meter for proper fastening without over-tightening\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eTUV Rheinland certified (ID 1111303479) - Type Approved, Safety, Regular Production Surveillance\u003c\/li\u003e\n      \u003cli\u003eCE marked for European market compliance\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) compliant\u003c\/li\u003e\n      \u003cli\u003eREACH (Registration, Evaluation, Authorisation and Restriction of Chemicals) compliant\u003c\/li\u003e\n      \u003cli\u003eUL94-V0 flame retardancy classification for the housing material\u003c\/li\u003e\n      \u003cli\u003eIP67 environmental protection rating while mated (dust-tight, resistant to temporary submersion)\u003c\/li\u003e\n      \u003cli\u003eShort circuit capacity: Up to 35.5 kiloamperes\u003c\/li\u003e\n      \u003cli\u003eInsulation resistance: Greater than 5000 megohms at 500V AC\u003c\/li\u003e\n      \u003cli\u003eWorking temperature range: 45 to 85 degrees Celsius\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eThree-phase power distribution panels requiring dedicated L2 phase inlets\u003c\/li\u003e\n      \u003cli\u003eDimmer rack and lighting control enclosures for theatrical and concert touring systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial manufacturing equipment with balanced three-phase power requirements\u003c\/li\u003e\n      \u003cli\u003ePower management systems for mining and heavy industry operations\u003c\/li\u003e\n      \u003cli\u003eUPS (Uninterruptible Power Supply) bypass panels and transfer switch enclosures\u003c\/li\u003e\n      \u003cli\u003eFestival and outdoor event power distribution boards with weather-exposed installations\u003c\/li\u003e\n      \u003cli\u003eGenerator paralleling switchboards requiring per-phase connection management\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe PowerFit 400A Panel Source connector is compatible with major brands of single-pole power connector systems. Its M12 threaded post interface and push-and-twist mating mechanism with key-release pin ensure standardized connection geometry across certified suppliers. The male contact mates with PowerFit Line Drain and Panel Drain connectors. Verify mechanical and electrical specifications with your mating connector manufacturer to confirm impedance matching and safe operating parameters. Use the color-coded and mechanically keyed design as a visual safeguard to prevent cross-phase connection errors during installation or reconfiguration.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPS-2BK | PowerFit 400A Panel Source, L2 (Phase B) Black (IEC - European)\",\n  \"description\": \"KUPO PowerFit 400A Panel Source single-pole connector with black housing for IEC - European power distribution systems. Male Contact, M12 threaded post mount, patent key-release pin for safe disconnection, IP67 rated when mated, silver-plated brass contacts, dual-rated 400A\/660A, 1000V AC \/ 1500V DC maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Panel-Mount Connectors \u003e PowerFit\",\n  \"sku\": \"PFPS-2BK\",\n  \"mpn\": \"PFPS-2BK\",\n  \"color\": \"Black\",\n  \"material\": \"Non-conductive thermoplastic housing; Brass silver-plated contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC \/ 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A continuous (120mm\u0026sup2; cable) \/ 660A continuous (240mm\u0026sup2; cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5 kiloamperes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Source (Male Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-Twist with Key-Release Mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cotter Pin Material\",\n      \"value\": \"POM (Polyoxymethylene)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mounting Type\",\n      \"value\": \"Panel Mount with M12 Threaded Post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fixing Holes\",\n      \"value\": \"Four diameter 5.5mm holes; 42mm x 42mm cut-out dimension\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fastener Material\",\n      \"value\": \"Brass nut and spring washer\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Maximum Nut Torque\",\n      \"value\": \"12 to 14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated; IP 2X finger protection\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"TUV Certification ID\",\n      \"value\": \"1111303479\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV Rheinland, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 (Phase B) (IEC - European)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Black\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPS-2BK\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhere is PFPS-2BK typically installed and what does it feed?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-2BK is a KUPO PowerFit 400A panel source connector with a black housing, identifying Line 2 (L2) under Europe and UK (IEC 60446) conventions. Mounted permanently at generator outputs, main panels, and power supply enclosures, it is the origin point from which power flows outward through the PowerFit system. Despite being panel-mounted, it retains the key-release mechanism for convenient field disconnection. It is commonly deployed in industrial manufacturing plant applications. Temporary power in manufacturing environments faces vibration from heavy machinery, exposure to oils and cutting fluids, and the need for high current capacity to feed welders, presses, and large motors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat electrical capacity does PFPS-2BK provide as a panel source connector?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-2BK is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for L2 circuits carrying continuous phase current.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the black housing on PFPS-2BK represent under Europe and UK (IEC 60446) standards?\u003c\/h3\u003e\n    \u003cp\u003eUnder IEC 60446, black identifies Line 2 (L2). This is the second phase conductor in the European three-phase system of brown (L1), black (L2), grey (L3). For international crews, this is a critical distinction: the same black housing that means L1 in North America means L2 in Europe. On the Panel Source, the black housing is visible on the connector face at the power origin point. Color coding at the source end of the distribution chain is especially important because phase assignment errors at the panel propagate through every downstream connection. Cross-convention errors between NEC-L1-black and IEC-L2-black are among the most common phase identification mistakes on international projects.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety certifications does PFPS-2BK hold for distribution panel use?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-2BK is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. As the power origin point, the Panel Source undergoes the same TUV safety evaluation as the full PowerFit system, including the key-release mechanism and panel-mount retention.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat equipment and enclosures is PFPS-2BK designed to mount in?\u003c\/h3\u003e\n    \u003cp\u003ePowerFit connectors are designed to be compatible with major brands of single-pole power connector. The 400A continuous rating (660A with 240mm2 cable) handles industrial loads, the flame-retardant UL94-V0 housing resists chemical exposure, and the push-and-twist lock prevents vibration-induced disconnection. For L2 circuits using Europe and UK (IEC 60446) color conventions, the black PFPS-2BK ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPS-2BK mounted in a distribution panel or generator output?\u003c\/h3\u003e\n    \u003cp\u003eThe PFPS-2BK mounts through a 42 x 42mm panel cutout using four 5.5mm fixing holes. The M12 threaded post secures to the panel with the included brass nut and washer at 12 to 14 N\/m maximum torque. Despite being a permanent panel-mount connector, PFPS-2BK retains the PowerFit key-release mechanism, allowing field technicians to disconnect mating Line Drain connectors without tools. IP 2X finger protection and a plastic end cap protect the contacts when no mating connector is present. The Panel Source has a 55.3mm flange width and 50.7mm total depth, with a 42.5mm body diameter. It is shallower than the Panel Drain, requiring less clearance behind the panel.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Where is PFPS-2BK typically installed and what does it feed?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2BK is a KUPO PowerFit 400A panel source connector with a black housing, identifying Line 2 (L2) under Europe and UK (IEC 60446) conventions. Mounted permanently at generator outputs, main panels, and power supply enclosures, it is the origin point from which power flows outward through the PowerFit system. Despite being panel-mounted, it retains the key-release mechanism for convenient field disconnection. It is commonly deployed in industrial manufacturing plant applications. Temporary power in manufacturing environments faces vibration from heavy machinery, exposure to oils and cutting fluids, and the need for high current capacity to feed welders, presses, and large motors.\"}}, {\"@type\": \"Question\", \"name\": \"What electrical capacity does PFPS-2BK provide as a panel source connector?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2BK is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for L2 circuits carrying continuous phase current.\"}}, {\"@type\": \"Question\", \"name\": \"What does the black housing on PFPS-2BK represent under Europe and UK (IEC 60446) standards?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Under IEC 60446, black identifies Line 2 (L2). This is the second phase conductor in the European three-phase system of brown (L1), black (L2), grey (L3). For international crews, this is a critical distinction: the same black housing that means L1 in North America means L2 in Europe. On the Panel Source, the black housing is visible on the connector face at the power origin point. Color coding at the source end of the distribution chain is especially important because phase assignment errors at the panel propagate through every downstream connection. Cross-convention errors between NEC-L1-black and IEC-L2-black are among the most common phase identification mistakes on international projects.\"}}, {\"@type\": \"Question\", \"name\": \"What safety certifications does PFPS-2BK hold for distribution panel use?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2BK is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. As the power origin point, the Panel Source undergoes the same TUV safety evaluation as the full PowerFit system, including the key-release mechanism and panel-mount retention.\"}}, {\"@type\": \"Question\", \"name\": \"What equipment and enclosures is PFPS-2BK designed to mount in?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PowerFit connectors are designed to be compatible with major brands of single-pole power connector. The 400A continuous rating (660A with 240mm2 cable) handles industrial loads, the flame-retardant UL94-V0 housing resists chemical exposure, and the push-and-twist lock prevents vibration-induced disconnection. For L2 circuits using Europe and UK (IEC 60446) color conventions, the black PFPS-2BK ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPS-2BK mounted in a distribution panel or generator output?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The PFPS-2BK mounts through a 42 x 42mm panel cutout using four 5.5mm fixing holes. The M12 threaded post secures to the panel with the included brass nut and washer at 12 to 14 N\/m maximum torque. Despite being a permanent panel-mount connector, PFPS-2BK retains the PowerFit key-release mechanism, allowing field technicians to disconnect mating Line Drain connectors without tools. IP 2X finger protection and a plastic end cap protect the contacts when no mating connector is present. The Panel Source has a 55.3mm flange width and 50.7mm total depth, with a 42.5mm body diameter. It is shallower than the Panel Drain, requiring less clearance behind the panel.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPS-2BK\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPS-2BK.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPS-2BK Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 400A \/ Panel Mount Receptacle","offer_id":50208844579036,"sku":"PFPS-2BK","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPS-2BK-b.jpg?v=1777364472"},{"product_id":"pfps-2r","title":"PFPS-2R - PowerFit 400A Source Panel Connector, Red (L2)","description":"\u003c!-- Combined Shopify product HTML for PFPS-2R --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPS-2R\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Panel Source Connector (Red) | PFPS-2R | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPS-2R\" data-color=\"Red\"\u003e\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eNorth American three-phase systems under NEC standards use red to identify the L2 (Phase B) conductor. The PowerFit 400A Panel Source in red serves as the fixed-panel power inlet for generator connection boxes, portable power distribution units, and entertainment industry dimmer racks where 400A per phase is standard. The M12 threaded post mount with brass nut and spring washer provides vibration-resistant panel attachment, and the 42mm x 42mm cut-out dimension with four diameter 5.5mm fixing holes matches standard industrial panel preparation specifications.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003e400A continuous current capacity at 120mm squared cable; 660A continuous at 240mm squared cable for heavy-duty applications\u003c\/li\u003e\n      \u003cli\u003eMale contact design provides the power source pin for mating with Line Drain or Panel Drain connectors\u003c\/li\u003e\n      \u003cli\u003ePatent key-release pin with POM (Polyoxymethylene) cotter pin enables tool-free disconnection without risking contact damage\u003c\/li\u003e\n      \u003cli\u003eM12 threaded post with brass nut and spring washer for permanent, vibration-resistant panel installation\u003c\/li\u003e\n      \u003cli\u003eFour diameter 5.5mm fixing holes on flange (42mm x 42mm cut-out dimension) ensure secure mechanical mounting\u003c\/li\u003e\n      \u003cli\u003ePlastic end cap over male contact provides IP 2X finger protection against electric shock when unmated\u003c\/li\u003e\n      \u003cli\u003ePush-and-twist locking mechanism maintains positive mechanical engagement across 500 rated mating cycles\u003c\/li\u003e\n      \u003cli\u003eBrass contact with silver plating delivers 0.1 milliohms contact resistance for minimal voltage drop and heat generation\u003c\/li\u003e\n      \u003cli\u003eNon-conductive thermoplastic housing rated UL94-V0 flame retardant for safety-critical installations\u003c\/li\u003e\n      \u003cli\u003eIP67 rating while connected ensures protection against water and dust ingress in outdoor or washdown environments\u003c\/li\u003e\n      \u003cli\u003e1000V AC \/ 1500V DC maximum voltage rating with 4500V AC dielectric test voltage for substantial safety margins\u003c\/li\u003e\n      \u003cli\u003eMaximum nut torque: 12 to 14 N\/meter for proper fastening without over-tightening\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eTUV Rheinland certified (ID 1111303479) - Type Approved, Safety, Regular Production Surveillance\u003c\/li\u003e\n      \u003cli\u003eCE marked for European market compliance\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) compliant\u003c\/li\u003e\n      \u003cli\u003eREACH (Registration, Evaluation, Authorisation and Restriction of Chemicals) compliant\u003c\/li\u003e\n      \u003cli\u003eUL94-V0 flame retardancy classification for the housing material\u003c\/li\u003e\n      \u003cli\u003eIP67 environmental protection rating while mated (dust-tight, resistant to temporary submersion)\u003c\/li\u003e\n      \u003cli\u003eShort circuit capacity: Up to 35.5 kiloamperes\u003c\/li\u003e\n      \u003cli\u003eInsulation resistance: Greater than 5000 megohms at 500V AC\u003c\/li\u003e\n      \u003cli\u003eWorking temperature range: 45 to 85 degrees Celsius\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eThree-phase power distribution panels requiring dedicated L2 phase inlets\u003c\/li\u003e\n      \u003cli\u003eDimmer rack and lighting control enclosures for theatrical and concert touring systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial manufacturing equipment with balanced three-phase power requirements\u003c\/li\u003e\n      \u003cli\u003ePower management systems for mining and heavy industry operations\u003c\/li\u003e\n      \u003cli\u003eUPS (Uninterruptible Power Supply) bypass panels and transfer switch enclosures\u003c\/li\u003e\n      \u003cli\u003eFestival and outdoor event power distribution boards with weather-exposed installations\u003c\/li\u003e\n      \u003cli\u003eGenerator paralleling switchboards requiring per-phase connection management\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe PowerFit 400A Panel Source connector is compatible with major brands of single-pole power connector systems. Its M12 threaded post interface and push-and-twist mating mechanism with key-release pin ensure standardized connection geometry across certified suppliers. The male contact mates with PowerFit Line Drain and Panel Drain connectors. Verify mechanical and electrical specifications with your mating connector manufacturer to confirm impedance matching and safe operating parameters. Use the color-coded and mechanically keyed design as a visual safeguard to prevent cross-phase connection errors during installation or reconfiguration.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPS-2R | PowerFit 400A Panel Source, L2 (Phase B) Red (NEC - North American)\",\n  \"description\": \"KUPO PowerFit 400A Panel Source single-pole connector with red housing for NEC - North American power distribution systems. Male Contact, M12 threaded post mount, patent key-release pin for safe disconnection, IP67 rated when mated, silver-plated brass contacts, dual-rated 400A\/660A, 1000V AC \/ 1500V DC maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Panel-Mount Connectors \u003e PowerFit\",\n  \"sku\": \"PFPS-2R\",\n  \"mpn\": \"PFPS-2R\",\n  \"color\": \"Red\",\n  \"material\": \"Non-conductive thermoplastic housing; Brass silver-plated contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC \/ 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A continuous (120mm\u0026sup2; cable) \/ 660A continuous (240mm\u0026sup2; cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5 kiloamperes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Source (Male Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-Twist with Key-Release Mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cotter Pin Material\",\n      \"value\": \"POM (Polyoxymethylene)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mounting Type\",\n      \"value\": \"Panel Mount with M12 Threaded Post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fixing Holes\",\n      \"value\": \"Four diameter 5.5mm holes; 42mm x 42mm cut-out dimension\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fastener Material\",\n      \"value\": \"Brass nut and spring washer\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Maximum Nut Torque\",\n      \"value\": \"12 to 14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated; IP 2X finger protection\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"TUV Certification ID\",\n      \"value\": \"1111303479\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV Rheinland, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 (Phase B) (NEC - North American)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Red\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPS-2R\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is PFPS-2R and why is it the starting point of power distribution?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-2R is a KUPO PowerFit 400A panel source connector with a red housing, identifying Line 2 (L2) under North America (NEC) conventions. Mounted permanently at generator outputs, main panels, and power supply enclosures, it is the origin point from which power flows outward through the PowerFit system. Despite being panel-mounted, it retains the key-release mechanism for convenient field disconnection. It is commonly deployed in construction site applications. Construction power distribution deals with dust, debris, rain, rough handling by crews, and the constant repositioning of equipment as the site evolves.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat are the power handling specifications of PFPS-2R?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-2R is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The insulation resistance exceeds 5000 megaohms at 500V AC, and the test voltage rating of 4500V AC provides substantial safety margin. The short circuit rating of up to 35.5 kiloamperes means the connector can withstand fault conditions without catastrophic failure.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the red housing on PFPS-2R represent under North America (NEC) standards?\u003c\/h3\u003e\n    \u003cp\u003eRed marks Line 2 (L2) under North American NEC conventions. In a standard three-phase system, the color sequence is black (L1), red (L2), blue (L3). Red L2 is one of the most commonly ordered phase variants for US and Canadian power distribution, appearing in virtually every multi-phase temporary power installation. On the Panel Source, the red housing is visible on the connector face at the power origin point. Color coding at the source end of the distribution chain is especially important because phase assignment errors at the panel propagate through every downstream connection. Red is one of the most visually distinctive colors on a busy event site, helping crews quickly trace the second phase conductor even from a distance.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPS-2R certified for use as a power source connector?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-2R is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. As the power origin point, the Panel Source undergoes the same TUV safety evaluation as the full PowerFit system, including the key-release mechanism and panel-mount retention.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat makes PFPS-2R installation straightforward for permanent power sources?\u003c\/h3\u003e\n    \u003cp\u003eThe PFPS-2R mounts through a 42 x 42mm panel cutout using four 5.5mm fixing holes. The M12 threaded post secures to the panel with the included brass nut and washer at 12 to 14 N\/m maximum torque. Despite being a permanent panel-mount connector, PFPS-2R retains the PowerFit key-release mechanism, allowing field technicians to disconnect mating Line Drain connectors without tools. IP 2X finger protection and a plastic end cap protect the contacts when no mating connector is present. The Panel Source has a 55.3mm flange width and 50.7mm total depth, with a 42.5mm body diameter. It is shallower than the Panel Drain, requiring less clearance behind the panel.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eCan PFPS-2R work alongside connectors from other brands in a distribution panel?\u003c\/h3\u003e\n    \u003cp\u003ePowerFit connectors are designed to be compatible with major brands of single-pole power connector. The high-impact thermoplastic housing absorbs punishment, the IP67 seal protects against dust ingress (the '6' in IP67 means dust-tight), and the M40 cable gland secures cables against pull-out. For L2 circuits using North America (NEC) color conventions, the red PFPS-2R ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is PFPS-2R and why is it the starting point of power distribution?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2R is a KUPO PowerFit 400A panel source connector with a red housing, identifying Line 2 (L2) under North America (NEC) conventions. Mounted permanently at generator outputs, main panels, and power supply enclosures, it is the origin point from which power flows outward through the PowerFit system. Despite being panel-mounted, it retains the key-release mechanism for convenient field disconnection. It is commonly deployed in construction site applications. Construction power distribution deals with dust, debris, rain, rough handling by crews, and the constant repositioning of equipment as the site evolves.\"}}, {\"@type\": \"Question\", \"name\": \"What are the power handling specifications of PFPS-2R?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2R is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The insulation resistance exceeds 5000 megaohms at 500V AC, and the test voltage rating of 4500V AC provides substantial safety margin. The short circuit rating of up to 35.5 kiloamperes means the connector can withstand fault conditions without catastrophic failure.\"}}, {\"@type\": \"Question\", \"name\": \"What does the red housing on PFPS-2R represent under North America (NEC) standards?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Red marks Line 2 (L2) under North American NEC conventions. In a standard three-phase system, the color sequence is black (L1), red (L2), blue (L3). Red L2 is one of the most commonly ordered phase variants for US and Canadian power distribution, appearing in virtually every multi-phase temporary power installation. On the Panel Source, the red housing is visible on the connector face at the power origin point. Color coding at the source end of the distribution chain is especially important because phase assignment errors at the panel propagate through every downstream connection. Red is one of the most visually distinctive colors on a busy event site, helping crews quickly trace the second phase conductor even from a distance.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPS-2R certified for use as a power source connector?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2R is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. As the power origin point, the Panel Source undergoes the same TUV safety evaluation as the full PowerFit system, including the key-release mechanism and panel-mount retention.\"}}, {\"@type\": \"Question\", \"name\": \"What makes PFPS-2R installation straightforward for permanent power sources?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The PFPS-2R mounts through a 42 x 42mm panel cutout using four 5.5mm fixing holes. The M12 threaded post secures to the panel with the included brass nut and washer at 12 to 14 N\/m maximum torque. Despite being a permanent panel-mount connector, PFPS-2R retains the PowerFit key-release mechanism, allowing field technicians to disconnect mating Line Drain connectors without tools. IP 2X finger protection and a plastic end cap protect the contacts when no mating connector is present. The Panel Source has a 55.3mm flange width and 50.7mm total depth, with a 42.5mm body diameter. It is shallower than the Panel Drain, requiring less clearance behind the panel.\"}}, {\"@type\": \"Question\", \"name\": \"Can PFPS-2R work alongside connectors from other brands in a distribution panel?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PowerFit connectors are designed to be compatible with major brands of single-pole power connector. The high-impact thermoplastic housing absorbs punishment, the IP67 seal protects against dust ingress (the '6' in IP67 means dust-tight), and the M40 cable gland secures cables against pull-out. For L2 circuits using North America (NEC) color conventions, the red PFPS-2R ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPS-2R\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPS-2R.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPS-2R Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 400A \/ Panel Mount Receptacle","offer_id":50208844611804,"sku":"PFPS-2R","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPS-2R.jpg?v=1777364473"},{"product_id":"pfps-2w","title":"PFPS-2W - PowerFit 400A Source Panel Connector, White (L2)","description":"\u003c!-- Combined Shopify product HTML for PFPS-2W --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPS-2W\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Panel Source Connector (White) | PFPS-2W | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPS-2W\" data-color=\"White\"\u003e\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eAustralian and New Zealand electrical installations following AS\/NZS 3000 designate white for the L2 phase conductor. The PowerFit 400A Panel Source in white provides a permanent panel-mounted power inlet for mining operations, outdoor festival infrastructure, and industrial facilities across the Oceania region. The connector's 1000V AC \/ 1500V DC maximum voltage rating and 4500V AC dielectric test voltage provide substantial safety margins for demanding electrical environments, while the patent key-release pin mechanism ensures safe disconnection without specialized tooling.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003e400A continuous current capacity at 120mm squared cable; 660A continuous at 240mm squared cable for heavy-duty applications\u003c\/li\u003e\n      \u003cli\u003eMale contact design provides the power source pin for mating with Line Drain or Panel Drain connectors\u003c\/li\u003e\n      \u003cli\u003ePatent key-release pin with POM (Polyoxymethylene) cotter pin enables tool-free disconnection without risking contact damage\u003c\/li\u003e\n      \u003cli\u003eM12 threaded post with brass nut and spring washer for permanent, vibration-resistant panel installation\u003c\/li\u003e\n      \u003cli\u003eFour diameter 5.5mm fixing holes on flange (42mm x 42mm cut-out dimension) ensure secure mechanical mounting\u003c\/li\u003e\n      \u003cli\u003ePlastic end cap over male contact provides IP 2X finger protection against electric shock when unmated\u003c\/li\u003e\n      \u003cli\u003ePush-and-twist locking mechanism maintains positive mechanical engagement across 500 rated mating cycles\u003c\/li\u003e\n      \u003cli\u003eBrass contact with silver plating delivers 0.1 milliohms contact resistance for minimal voltage drop and heat generation\u003c\/li\u003e\n      \u003cli\u003eNon-conductive thermoplastic housing rated UL94-V0 flame retardant for safety-critical installations\u003c\/li\u003e\n      \u003cli\u003eIP67 rating while connected ensures protection against water and dust ingress in outdoor or washdown environments\u003c\/li\u003e\n      \u003cli\u003e1000V AC \/ 1500V DC maximum voltage rating with 4500V AC dielectric test voltage for substantial safety margins\u003c\/li\u003e\n      \u003cli\u003eMaximum nut torque: 12 to 14 N\/meter for proper fastening without over-tightening\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eTUV Rheinland certified (ID 1111303479) - Type Approved, Safety, Regular Production Surveillance\u003c\/li\u003e\n      \u003cli\u003eCE marked for European market compliance\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) compliant\u003c\/li\u003e\n      \u003cli\u003eREACH (Registration, Evaluation, Authorisation and Restriction of Chemicals) compliant\u003c\/li\u003e\n      \u003cli\u003eUL94-V0 flame retardancy classification for the housing material\u003c\/li\u003e\n      \u003cli\u003eIP67 environmental protection rating while mated (dust-tight, resistant to temporary submersion)\u003c\/li\u003e\n      \u003cli\u003eShort circuit capacity: Up to 35.5 kiloamperes\u003c\/li\u003e\n      \u003cli\u003eInsulation resistance: Greater than 5000 megohms at 500V AC\u003c\/li\u003e\n      \u003cli\u003eWorking temperature range: 45 to 85 degrees Celsius\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eThree-phase power distribution panels requiring dedicated L2 phase inlets\u003c\/li\u003e\n      \u003cli\u003eDimmer rack and lighting control enclosures for theatrical and concert touring systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial manufacturing equipment with balanced three-phase power requirements\u003c\/li\u003e\n      \u003cli\u003ePower management systems for mining and heavy industry operations\u003c\/li\u003e\n      \u003cli\u003eUPS (Uninterruptible Power Supply) bypass panels and transfer switch enclosures\u003c\/li\u003e\n      \u003cli\u003eFestival and outdoor event power distribution boards with weather-exposed installations\u003c\/li\u003e\n      \u003cli\u003eGenerator paralleling switchboards requiring per-phase connection management\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe PowerFit 400A Panel Source connector is compatible with major brands of single-pole power connector systems. Its M12 threaded post interface and push-and-twist mating mechanism with key-release pin ensure standardized connection geometry across certified suppliers. The male contact mates with PowerFit Line Drain and Panel Drain connectors. Verify mechanical and electrical specifications with your mating connector manufacturer to confirm impedance matching and safe operating parameters. Use the color-coded and mechanically keyed design as a visual safeguard to prevent cross-phase connection errors during installation or reconfiguration.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPS-2W | PowerFit 400A Panel Source, L2 (Phase B) White (Australian)\",\n  \"description\": \"KUPO PowerFit 400A Panel Source single-pole connector with white housing for Australian power distribution systems. Male Contact, M12 threaded post mount, patent key-release pin for safe disconnection, IP67 rated when mated, silver-plated brass contacts, dual-rated 400A\/660A, 1000V AC \/ 1500V DC maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Panel-Mount Connectors \u003e PowerFit\",\n  \"sku\": \"PFPS-2W\",\n  \"mpn\": \"PFPS-2W\",\n  \"color\": \"White\",\n  \"material\": \"Non-conductive thermoplastic housing; Brass silver-plated contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC \/ 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A continuous (120mm\u0026sup2; cable) \/ 660A continuous (240mm\u0026sup2; cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5 kiloamperes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Source (Male Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-Twist with Key-Release Mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cotter Pin Material\",\n      \"value\": \"POM (Polyoxymethylene)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mounting Type\",\n      \"value\": \"Panel Mount with M12 Threaded Post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fixing Holes\",\n      \"value\": \"Four diameter 5.5mm holes; 42mm x 42mm cut-out dimension\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fastener Material\",\n      \"value\": \"Brass nut and spring washer\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Maximum Nut Torque\",\n      \"value\": \"12 to 14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated; IP 2X finger protection\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"TUV Certification ID\",\n      \"value\": \"1111303479\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV Rheinland, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 (Phase B) (Australian)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"White\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPS-2W\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does PFPS-2W combine panel mounting with disconnect convenience?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-2W is a KUPO PowerFit 400A panel source connector with a white housing, identifying Line 2 (L2) under Australia conventions. Mounted permanently at generator outputs, main panels, and power supply enclosures, it is the origin point from which power flows outward through the PowerFit system. Despite being panel-mounted, it retains the key-release mechanism for convenient field disconnection. It is commonly deployed in marine and shipyard applications. Shipyard and dockside power connections face salt spray, high humidity, and the corrosive marine environment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current can PFPS-2W supply from a distribution panel?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-2W is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The M12 threaded post termination accepts conductors through a brass nut and washer assembly, tightened to a maximum of 12 to 14 N\/m. The four-point flange mount with 5.5mm fixing holes distributes mechanical load across the panel surface.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the white housing on PFPS-2W represent under Australia standards?\u003c\/h3\u003e\n    \u003cp\u003eWhite as L2 follows Australian wiring conventions, where the three-phase set is red (L1), white (L2), blue (L3). This variant specifically serves Australian, New Zealand, and related Asia-Pacific markets. On the Panel Source, the white housing is visible on the connector face at the power origin point. Color coding at the source end of the distribution chain is especially important because phase assignment errors at the panel propagate through every downstream connection. The stark visual contrast between white L2 and the darker L1\/L3 conductors makes phase tracing straightforward in Australian installations.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat independent testing has PFPS-2W undergone?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-2W is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. As the power origin point, the Panel Source undergoes the same TUV safety evaluation as the full PowerFit system, including the key-release mechanism and panel-mount retention.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does PFPS-2W integrate with existing power infrastructure in marine and shipyard settings?\u003c\/h3\u003e\n    \u003cp\u003ePowerFit connectors are designed to be compatible with major brands of single-pole power connector. Silver-plated brass contacts resist corrosion far better than plain brass, the silicone O-ring maintains IP67 sealing in high-humidity conditions, and the non-conductive thermoplastic housing is impervious to salt corrosion. For L2 circuits using Australia color conventions, the white PFPS-2W ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"How does PFPS-2W combine panel mounting with disconnect convenience?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2W is a KUPO PowerFit 400A panel source connector with a white housing, identifying Line 2 (L2) under Australia conventions. Mounted permanently at generator outputs, main panels, and power supply enclosures, it is the origin point from which power flows outward through the PowerFit system. Despite being panel-mounted, it retains the key-release mechanism for convenient field disconnection. It is commonly deployed in marine and shipyard applications. Shipyard and dockside power connections face salt spray, high humidity, and the corrosive marine environment.\"}}, {\"@type\": \"Question\", \"name\": \"How much current can PFPS-2W supply from a distribution panel?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2W is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The M12 threaded post termination accepts conductors through a brass nut and washer assembly, tightened to a maximum of 12 to 14 N\/m. The four-point flange mount with 5.5mm fixing holes distributes mechanical load across the panel surface.\"}}, {\"@type\": \"Question\", \"name\": \"What does the white housing on PFPS-2W represent under Australia standards?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"White as L2 follows Australian wiring conventions, where the three-phase set is red (L1), white (L2), blue (L3). This variant specifically serves Australian, New Zealand, and related Asia-Pacific markets. On the Panel Source, the white housing is visible on the connector face at the power origin point. Color coding at the source end of the distribution chain is especially important because phase assignment errors at the panel propagate through every downstream connection. The stark visual contrast between white L2 and the darker L1\/L3 conductors makes phase tracing straightforward in Australian installations.\"}}, {\"@type\": \"Question\", \"name\": \"What independent testing has PFPS-2W undergone?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2W is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. As the power origin point, the Panel Source undergoes the same TUV safety evaluation as the full PowerFit system, including the key-release mechanism and panel-mount retention.\"}}, {\"@type\": \"Question\", \"name\": \"How does PFPS-2W integrate with existing power infrastructure in marine and shipyard settings?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PowerFit connectors are designed to be compatible with major brands of single-pole power connector. Silver-plated brass contacts resist corrosion far better than plain brass, the silicone O-ring maintains IP67 sealing in high-humidity conditions, and the non-conductive thermoplastic housing is impervious to salt corrosion. For L2 circuits using Australia color conventions, the white PFPS-2W ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPS-2W\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPS-2W.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPS-2W Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 400A \/ Panel Mount Receptacle","offer_id":50208844644572,"sku":"PFPS-2W","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPS-2W-b.jpg?v=1777364474"},{"product_id":"pfps-2y","title":"PFPS-2Y - PowerFit 400A Source Panel Connector, Yellow (L2)","description":"\u003c!-- Combined Shopify product HTML for PFPS-2Y --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPS-2Y\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Panel Source Connector (Yellow) | PFPS-2Y | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPS-2Y\" data-color=\"Yellow\"\u003e\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eLegacy UK electrical installations using the older BS 7671 color scheme identify yellow as the L2 phase conductor. The PowerFit 400A Panel Source in yellow supports maintenance and expansion of existing infrastructure in heritage venues, older industrial facilities, and theatrical buildings that have not yet transitioned to the modern IEC color standard. The non-conductive thermoplastic housing achieves UL94-V0 flame retardancy, and the push-and-twist connection mechanism with patent key-release pin maintains reliable electrical contact across the full 500-cycle rated mating life.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003e400A continuous current capacity at 120mm squared cable; 660A continuous at 240mm squared cable for heavy-duty applications\u003c\/li\u003e\n      \u003cli\u003eMale contact design provides the power source pin for mating with Line Drain or Panel Drain connectors\u003c\/li\u003e\n      \u003cli\u003ePatent key-release pin with POM (Polyoxymethylene) cotter pin enables tool-free disconnection without risking contact damage\u003c\/li\u003e\n      \u003cli\u003eM12 threaded post with brass nut and spring washer for permanent, vibration-resistant panel installation\u003c\/li\u003e\n      \u003cli\u003eFour diameter 5.5mm fixing holes on flange (42mm x 42mm cut-out dimension) ensure secure mechanical mounting\u003c\/li\u003e\n      \u003cli\u003ePlastic end cap over male contact provides IP 2X finger protection against electric shock when unmated\u003c\/li\u003e\n      \u003cli\u003ePush-and-twist locking mechanism maintains positive mechanical engagement across 500 rated mating cycles\u003c\/li\u003e\n      \u003cli\u003eBrass contact with silver plating delivers 0.1 milliohms contact resistance for minimal voltage drop and heat generation\u003c\/li\u003e\n      \u003cli\u003eNon-conductive thermoplastic housing rated UL94-V0 flame retardant for safety-critical installations\u003c\/li\u003e\n      \u003cli\u003eIP67 rating while connected ensures protection against water and dust ingress in outdoor or washdown environments\u003c\/li\u003e\n      \u003cli\u003e1000V AC \/ 1500V DC maximum voltage rating with 4500V AC dielectric test voltage for substantial safety margins\u003c\/li\u003e\n      \u003cli\u003eMaximum nut torque: 12 to 14 N\/meter for proper fastening without over-tightening\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eTUV Rheinland certified (ID 1111303479) - Type Approved, Safety, Regular Production Surveillance\u003c\/li\u003e\n      \u003cli\u003eCE marked for European market compliance\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) compliant\u003c\/li\u003e\n      \u003cli\u003eREACH (Registration, Evaluation, Authorisation and Restriction of Chemicals) compliant\u003c\/li\u003e\n      \u003cli\u003eUL94-V0 flame retardancy classification for the housing material\u003c\/li\u003e\n      \u003cli\u003eIP67 environmental protection rating while mated (dust-tight, resistant to temporary submersion)\u003c\/li\u003e\n      \u003cli\u003eShort circuit capacity: Up to 35.5 kiloamperes\u003c\/li\u003e\n      \u003cli\u003eInsulation resistance: Greater than 5000 megohms at 500V AC\u003c\/li\u003e\n      \u003cli\u003eWorking temperature range: 45 to 85 degrees Celsius\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eThree-phase power distribution panels requiring dedicated L2 phase inlets\u003c\/li\u003e\n      \u003cli\u003eDimmer rack and lighting control enclosures for theatrical and concert touring systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial manufacturing equipment with balanced three-phase power requirements\u003c\/li\u003e\n      \u003cli\u003ePower management systems for mining and heavy industry operations\u003c\/li\u003e\n      \u003cli\u003eUPS (Uninterruptible Power Supply) bypass panels and transfer switch enclosures\u003c\/li\u003e\n      \u003cli\u003eFestival and outdoor event power distribution boards with weather-exposed installations\u003c\/li\u003e\n      \u003cli\u003eGenerator paralleling switchboards requiring per-phase connection management\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe PowerFit 400A Panel Source connector is compatible with major brands of single-pole power connector systems. Its M12 threaded post interface and push-and-twist mating mechanism with key-release pin ensure standardized connection geometry across certified suppliers. The male contact mates with PowerFit Line Drain and Panel Drain connectors. Verify mechanical and electrical specifications with your mating connector manufacturer to confirm impedance matching and safe operating parameters. Use the color-coded and mechanically keyed design as a visual safeguard to prevent cross-phase connection errors during installation or reconfiguration.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPS-2Y | PowerFit 400A Panel Source, L2 (Phase B) Yellow (UK (Old Standard))\",\n  \"description\": \"KUPO PowerFit 400A Panel Source single-pole connector with yellow housing for UK (Old Standard) power distribution systems. Male Contact, M12 threaded post mount, patent key-release pin for safe disconnection, IP67 rated when mated, silver-plated brass contacts, dual-rated 400A\/660A, 1000V AC \/ 1500V DC maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Panel-Mount Connectors \u003e PowerFit\",\n  \"sku\": \"PFPS-2Y\",\n  \"mpn\": \"PFPS-2Y\",\n  \"color\": \"Yellow\",\n  \"material\": \"Non-conductive thermoplastic housing; Brass silver-plated contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC \/ 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A continuous (120mm\u0026sup2; cable) \/ 660A continuous (240mm\u0026sup2; cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5 kiloamperes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Source (Male Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-Twist with Key-Release Mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cotter Pin Material\",\n      \"value\": \"POM (Polyoxymethylene)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mounting Type\",\n      \"value\": \"Panel Mount with M12 Threaded Post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fixing Holes\",\n      \"value\": \"Four diameter 5.5mm holes; 42mm x 42mm cut-out dimension\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fastener Material\",\n      \"value\": \"Brass nut and spring washer\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Maximum Nut Torque\",\n      \"value\": \"12 to 14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated; IP 2X finger protection\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"TUV Certification ID\",\n      \"value\": \"1111303479\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV Rheinland, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 (Phase B) (UK (Old Standard))\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Yellow\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPS-2Y\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat makes PFPS-2Y the origin point in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-2Y is a KUPO PowerFit 400A panel source connector with a yellow housing, identifying Line 2 (L2) under UK (Old, pre-2004) conventions. Mounted permanently at generator outputs, main panels, and power supply enclosures, it is the origin point from which power flows outward through the PowerFit system. Despite being panel-mounted, it retains the key-release mechanism for convenient field disconnection. It is commonly deployed in data center maintenance applications. During data center expansion or maintenance windows, temporary power must be distributed with absolute reliability.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat electrical capacity does PFPS-2Y provide as a panel source connector?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-2Y is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for L2 circuits carrying continuous phase current.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the yellow housing on PFPS-2Y represent under UK (Old, pre-2004) standards?\u003c\/h3\u003e\n    \u003cp\u003eYellow identifies L2 under the legacy UK wiring color code (red\/yellow\/blue for L1\/L2\/L3) used before the 2004 harmonization to IEC standards. Legacy UK installations, some Commonwealth countries, and specialty applications still use this color scheme. On the Panel Source, the yellow housing is visible on the connector face at the power origin point. Color coding at the source end of the distribution chain is especially important because phase assignment errors at the panel propagate through every downstream connection. When maintaining or extending pre-2004 UK installations, matching the existing yellow L2 convention prevents confusion between old and new color systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety certifications does PFPS-2Y hold for distribution panel use?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-2Y is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. As the power origin point, the Panel Source undergoes the same TUV safety evaluation as the full PowerFit system, including the key-release mechanism and panel-mount retention.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPS-2Y mounted in a distribution panel or generator output?\u003c\/h3\u003e\n    \u003cp\u003eThe PFPS-2Y mounts through a 42 x 42mm panel cutout using four 5.5mm fixing holes. The M12 threaded post secures to the panel with the included brass nut and washer at 12 to 14 N\/m maximum torque. Despite being a permanent panel-mount connector, PFPS-2Y retains the PowerFit key-release mechanism, allowing field technicians to disconnect mating Line Drain connectors without tools. IP 2X finger protection and a plastic end cap protect the contacts when no mating connector is present. The Panel Source has a 55.3mm flange width and 50.7mm total depth, with a 42.5mm body diameter. It is shallower than the Panel Drain, requiring less clearance behind the panel.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhy choose PFPS-2Y over a traditional panel-mount single-pole connector?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-2Y offers several meaningful improvements over conventional single-pole power connectors: IP67 protection when mated provides dust-tight and waterproof sealing that most single-pole connectors lack; the 1000V AC \/ 1500V DC voltage rating exceeds the typical 600V maximum of traditional alternatives; silver-plated brass contacts deliver lower contact resistance (0.1 milliohms) than plain brass. These features, combined with TUV Rheinland certification and the phase-encoded yellow housing for L2 identification, make PowerFit a generation ahead of traditional designs.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What makes PFPS-2Y the origin point in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2Y is a KUPO PowerFit 400A panel source connector with a yellow housing, identifying Line 2 (L2) under UK (Old, pre-2004) conventions. Mounted permanently at generator outputs, main panels, and power supply enclosures, it is the origin point from which power flows outward through the PowerFit system. Despite being panel-mounted, it retains the key-release mechanism for convenient field disconnection. It is commonly deployed in data center maintenance applications. During data center expansion or maintenance windows, temporary power must be distributed with absolute reliability.\"}}, {\"@type\": \"Question\", \"name\": \"What electrical capacity does PFPS-2Y provide as a panel source connector?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2Y is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for L2 circuits carrying continuous phase current.\"}}, {\"@type\": \"Question\", \"name\": \"What does the yellow housing on PFPS-2Y represent under UK (Old, pre-2004) standards?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yellow identifies L2 under the legacy UK wiring color code (red\/yellow\/blue for L1\/L2\/L3) used before the 2004 harmonization to IEC standards. Legacy UK installations, some Commonwealth countries, and specialty applications still use this color scheme. On the Panel Source, the yellow housing is visible on the connector face at the power origin point. Color coding at the source end of the distribution chain is especially important because phase assignment errors at the panel propagate through every downstream connection. When maintaining or extending pre-2004 UK installations, matching the existing yellow L2 convention prevents confusion between old and new color systems.\"}}, {\"@type\": \"Question\", \"name\": \"What safety certifications does PFPS-2Y hold for distribution panel use?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2Y is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. As the power origin point, the Panel Source undergoes the same TUV safety evaluation as the full PowerFit system, including the key-release mechanism and panel-mount retention.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPS-2Y mounted in a distribution panel or generator output?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The PFPS-2Y mounts through a 42 x 42mm panel cutout using four 5.5mm fixing holes. The M12 threaded post secures to the panel with the included brass nut and washer at 12 to 14 N\/m maximum torque. Despite being a permanent panel-mount connector, PFPS-2Y retains the PowerFit key-release mechanism, allowing field technicians to disconnect mating Line Drain connectors without tools. IP 2X finger protection and a plastic end cap protect the contacts when no mating connector is present. The Panel Source has a 55.3mm flange width and 50.7mm total depth, with a 42.5mm body diameter. It is shallower than the Panel Drain, requiring less clearance behind the panel.\"}}, {\"@type\": \"Question\", \"name\": \"Why choose PFPS-2Y over a traditional panel-mount single-pole connector?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2Y offers several meaningful improvements over conventional single-pole power connectors: IP67 protection when mated provides dust-tight and waterproof sealing that most single-pole connectors lack; the 1000V AC \/ 1500V DC voltage rating exceeds the typical 600V maximum of traditional alternatives; silver-plated brass contacts deliver lower contact resistance (0.1 milliohms) than plain brass. These features, combined with TUV Rheinland certification and the phase-encoded yellow housing for L2 identification, make PowerFit a generation ahead of traditional designs.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPS-2Y\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPS-2Y.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPS-2Y Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 400A \/ Panel Mount Receptacle","offer_id":50208844677340,"sku":"PFPS-2Y","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPS-2Y.jpg?v=1777364475"}],"url":"https:\/\/kupopower.com\/collections\/powerfit-400a-phase-b-l2.oembed","provider":"KUPO Power","version":"1.0","type":"link"}