{"title":"PowerFit 800A","description":"\u003c!-- KUPO Power - PowerFit 800A (TIER 1 - Main Family Hub)\n     Shopify Collection Body HTML\n     Handle: powerfit-800a\n     URL: https:\/\/kupopower.com\/collections\/powerfit-800a --\u003e\n\n\u003cp\u003ePowerFit 800A is KUPO Power's keyed single-pole 800A connector family for high-current temporary and fixed power distribution. It is designed for live events, energy storage, data centers, generator rental, industrial power systems, and other applications where safe high-amperage connection, clear phase identification, and fast deployment matter. The family includes line source connectors, line drain connectors, panel mount source connectors, and panel mount drain connectors, with mechanical keying to help prevent cross-phasing at the cable end and panel interface.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePhase identification (IEC 60446 European color code)\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cdiv style=\"overflow-x:auto;\"\u003e\n\u003ctable style=\"border-collapse:collapse !important; width:100%; max-width:600px; border:1px solid #999 !important;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background:#0072B8 !important; color:#fff !important;\"\u003e\n\u003cth style=\"padding:8px !important; border:1px solid #c0d8ee !important; color:#fff !important; background:#0072B8 !important; text-align:left;\"\u003ePhase\u003c\/th\u003e\n\u003cth style=\"padding:8px !important; border:1px solid #c0d8ee !important; color:#fff !important; background:#0072B8 !important; text-align:left;\"\u003eIEC 60446 Color\u003c\/th\u003e\n\u003cth style=\"padding:8px !important; border:1px solid #c0d8ee !important; color:#fff !important; background:#0072B8 !important; text-align:left;\"\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important; font-weight:bold;\"\u003ePhase A (L1)\u003c\/td\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important;\"\u003eBrown\u003c\/td\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important;\"\u003eFirst live phase\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important; font-weight:bold;\"\u003ePhase B (L2)\u003c\/td\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important;\"\u003eBlack\u003c\/td\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important;\"\u003eSecond live phase\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important; font-weight:bold;\"\u003ePhase C (L3)\u003c\/td\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important;\"\u003eGrey\u003c\/td\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important;\"\u003eThird live phase\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important; font-weight:bold;\"\u003eNeutral (N)\u003c\/td\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important;\"\u003eBlue\u003c\/td\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important;\"\u003eReturn \/ neutral conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important; font-weight:bold;\"\u003eGround \/ Earth (PE)\u003c\/td\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important;\"\u003eGreen \/ Yellow\u003c\/td\u003e\n\u003ctd style=\"padding:8px !important; border:1px solid #999 !important;\"\u003eProtective earth\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eSource and Drain mating\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003ePowerFit 800A follows the keyed single-pole convention where Source connectors carry power from a generator, substation, or power source, and Drain connectors deliver power into distribution equipment. Sources only mate with Drains. The keyed design helps avoid wrong-phase mating and supports safer system assembly for high-current circuits.\u003c\/p\u003e\n\n\u003cp style=\"margin-top:1rem; font-size:0.95rem;\"\u003eBrowse by phase: \u003ca href=\"https:\/\/kupopower.com\/collections\/powerfit-800a-phase-a-l1\"\u003ePhase A (L1)\u003c\/a\u003e · \u003ca href=\"https:\/\/kupopower.com\/collections\/powerfit-800a-phase-b-l2\"\u003ePhase B (L2)\u003c\/a\u003e · \u003ca href=\"https:\/\/kupopower.com\/collections\/powerfit-800a-phase-c-l3\"\u003ePhase C (L3)\u003c\/a\u003e · \u003ca href=\"https:\/\/kupopower.com\/collections\/powerfit-800a-neutral\"\u003eNeutral\u003c\/a\u003e · \u003ca href=\"https:\/\/kupopower.com\/collections\/powerfit-800a-ground-earth-connectors\"\u003eGround \/ Earth\u003c\/a\u003e  |  By form factor: \u003ca href=\"https:\/\/kupopower.com\/collections\/powerfit-800a-line-source\"\u003eLine Source\u003c\/a\u003e · \u003ca href=\"https:\/\/kupopower.com\/collections\/powerfit-800a-line-drain\"\u003eLine Drain\u003c\/a\u003e · \u003ca href=\"https:\/\/kupopower.com\/collections\/powerfit-800a-panel-mount-source\"\u003ePanel Mount Source\u003c\/a\u003e · \u003ca href=\"https:\/\/kupopower.com\/collections\/powerfit-800a-panel-mount-drain\"\u003ePanel Mount Drain\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cp style=\"margin-top:1.25rem;\"\u003e\u003ca href=\"https:\/\/kupopower.com\/pages\/powerfit-800a-keyed-single-pole-power-connectors\"\u003e\u003cstrong\u003eRead the full PowerFit 800A guide \u0026gt;\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e","products":[{"product_id":"pfld-1bk-c300-400-m40-m50","title":"PFLD-1BK-C300-400-M40-M50 - PowerFit 800A Line Drain, L1 (Line 1) Black","description":"\u003c!-- Combined Shopify product HTML for PFLD-1BK-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLD-1BK-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLD-1BK-C300-400-M40-M50 | PowerFit 800A Line Drain, L1 (Line 1) Black (NEC - North American) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLD-1BK-C300-400-M40-M50\" data-color=\"Black\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLD-1BK-C300-400-M40-M50 is an 800A PowerFit single-pole line drain connector for high-current temporary and permanent power distribution. Its black housing identifies Line 1 (L1), while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLD-1BK-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLD-1BK-C300-400-M40-M50 | PowerFit 800A Line Drain, L1 (Line 1) Black (NEC - North American)\",\n  \"description\": \"KUPO PowerFit 800A Line Drain single-pole connector with black housing for Line 1. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLD-1BK-C300-400-M40-M50\",\n  \"mpn\": \"PFLD-1BK-C300-400-M40-M50\",\n  \"color\": \"Black\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L1 - Line 1 (NEC - North American)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Black\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLD-1BK-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLD-1BK-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-1BK-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a black housing for Line 1 (L1). As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLD-1BK-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-1BK-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the black housing on PFLD-1BK-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe black housing identifies Line 1 (L1). The source spec sheet associates this colour with NEC - North American, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLD-1BK-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-1BK-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLD-1BK-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLD-1BK-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-1BK-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a black housing for Line 1 (L1). As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLD-1BK-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-1BK-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the black housing on PFLD-1BK-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The black housing identifies Line 1 (L1). The source spec sheet associates this colour with NEC - North American, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLD-1BK-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-1BK-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLD-1BK-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLD-1BK-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLD-1BK-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLD-1BK-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016018227420,"sku":"PFLD-1BK-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLD-1BK-C300-C400-M40-M50.jpg?v=1783592426"},{"product_id":"pfld-1bn-c300-400-m40-m50","title":"PFLD-1BN-C300-400-M40-M50 - PowerFit 800A Line Drain, L1 (Line 1) Brown","description":"\u003c!-- Combined Shopify product HTML for PFLD-1BN-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLD-1BN-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLD-1BN-C300-400-M40-M50 | PowerFit 800A Line Drain, L1 (Line 1) Brown (IEC) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLD-1BN-C300-400-M40-M50\" data-color=\"Brown\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLD-1BN-C300-400-M40-M50 is an 800A PowerFit single-pole line drain connector for high-current temporary and permanent power distribution. Its brown housing identifies Line 1 (L1), while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLD-1BN-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLD-1BN-C300-400-M40-M50 | PowerFit 800A Line Drain, L1 (Line 1) Brown (IEC)\",\n  \"description\": \"KUPO PowerFit 800A Line Drain single-pole connector with brown housing for Line 1. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLD-1BN-C300-400-M40-M50\",\n  \"mpn\": \"PFLD-1BN-C300-400-M40-M50\",\n  \"color\": \"Brown\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L1 - Line 1 (IEC)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Brown\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLD-1BN-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLD-1BN-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-1BN-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a brown housing for Line 1 (L1). As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLD-1BN-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-1BN-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the brown housing on PFLD-1BN-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe brown housing identifies Line 1 (L1). The source spec sheet associates this colour with IEC, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLD-1BN-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-1BN-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLD-1BN-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLD-1BN-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-1BN-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a brown housing for Line 1 (L1). As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLD-1BN-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-1BN-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the brown housing on PFLD-1BN-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The brown housing identifies Line 1 (L1). The source spec sheet associates this colour with IEC, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLD-1BN-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-1BN-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLD-1BN-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLD-1BN-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLD-1BN-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLD-1BN-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016026714332,"sku":"PFLD-1BN-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLD-1BN-C300-C400-M40-M50.jpg?v=1783592432"},{"product_id":"pfld-1r-c300-400-m40-m50","title":"PFLD-1R-C300-400-M40-M50 - PowerFit 800A Line Drain, L1 (Line 1) Red","description":"\u003c!-- Combined Shopify product HTML for PFLD-1R-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLD-1R-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLD-1R-C300-400-M40-M50 | PowerFit 800A Line Drain, L1 (Line 1) Red (regional phase colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLD-1R-C300-400-M40-M50\" data-color=\"Red\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLD-1R-C300-400-M40-M50 is an 800A PowerFit single-pole line drain connector for high-current temporary and permanent power distribution. Its red housing identifies Line 1 (L1), while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLD-1R-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLD-1R-C300-400-M40-M50 | PowerFit 800A Line Drain, L1 (Line 1) Red (regional phase colour)\",\n  \"description\": \"KUPO PowerFit 800A Line Drain single-pole connector with red housing for Line 1. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLD-1R-C300-400-M40-M50\",\n  \"mpn\": \"PFLD-1R-C300-400-M40-M50\",\n  \"color\": \"Red\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L1 - Line 1 (regional phase colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Red\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLD-1R-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLD-1R-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-1R-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a red housing for Line 1 (L1). As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLD-1R-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-1R-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the red housing on PFLD-1R-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe red housing identifies Line 1 (L1). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLD-1R-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-1R-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLD-1R-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLD-1R-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-1R-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a red housing for Line 1 (L1). As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLD-1R-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-1R-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the red housing on PFLD-1R-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The red housing identifies Line 1 (L1). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLD-1R-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-1R-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLD-1R-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLD-1R-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLD-1R-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLD-1R-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016035070172,"sku":"PFLD-1R-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLD-1R-C300-C400-M40-M50.jpg?v=1783592438"},{"product_id":"pfld-2bk-c300-400-m40-m50","title":"PFLD-2BK-C300-400-M40-M50 - PowerFit 800A Line Drain, L2 (Line 2) Black","description":"\u003c!-- Combined Shopify product HTML for PFLD-2BK-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLD-2BK-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLD-2BK-C300-400-M40-M50 | PowerFit 800A Line Drain, L2 (Line 2) Black (regional phase colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLD-2BK-C300-400-M40-M50\" data-color=\"Black\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLD-2BK-C300-400-M40-M50 is an 800A PowerFit single-pole line drain connector for high-current temporary and permanent power distribution. Its black housing identifies Line 2 (L2), while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLD-2BK-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLD-2BK-C300-400-M40-M50 | PowerFit 800A Line Drain, L2 (Line 2) Black (regional phase colour)\",\n  \"description\": \"KUPO PowerFit 800A Line Drain single-pole connector with black housing for Line 2. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLD-2BK-C300-400-M40-M50\",\n  \"mpn\": \"PFLD-2BK-C300-400-M40-M50\",\n  \"color\": \"Black\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 - Line 2 (regional phase colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Black\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLD-2BK-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLD-2BK-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-2BK-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a black housing for Line 2 (L2). As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLD-2BK-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-2BK-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the black housing on PFLD-2BK-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe black housing identifies Line 2 (L2). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLD-2BK-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-2BK-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLD-2BK-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLD-2BK-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-2BK-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a black housing for Line 2 (L2). As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLD-2BK-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-2BK-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the black housing on PFLD-2BK-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The black housing identifies Line 2 (L2). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLD-2BK-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-2BK-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLD-2BK-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLD-2BK-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLD-2BK-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLD-2BK-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016043753692,"sku":"PFLD-2BK-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLD-2BK-C300-C400-M40-M50.jpg?v=1783592444"},{"product_id":"pfld-2r-c300-400-m40-m50","title":"PFLD-2R-C300-400-M40-M50 - PowerFit 800A Line Drain, L2 (Line 2) Red","description":"\u003c!-- Combined Shopify product HTML for PFLD-2R-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLD-2R-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLD-2R-C300-400-M40-M50 | PowerFit 800A Line Drain, L2 (Line 2) Red (NEC - North American) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLD-2R-C300-400-M40-M50\" data-color=\"Red\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLD-2R-C300-400-M40-M50 is an 800A PowerFit single-pole line drain connector for high-current temporary and permanent power distribution. Its red housing identifies Line 2 (L2), while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLD-2R-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLD-2R-C300-400-M40-M50 | PowerFit 800A Line Drain, L2 (Line 2) Red (NEC - North American)\",\n  \"description\": \"KUPO PowerFit 800A Line Drain single-pole connector with red housing for Line 2. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLD-2R-C300-400-M40-M50\",\n  \"mpn\": \"PFLD-2R-C300-400-M40-M50\",\n  \"color\": \"Red\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 - Line 2 (NEC - North American)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Red\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLD-2R-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLD-2R-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-2R-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a red housing for Line 2 (L2). As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLD-2R-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-2R-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the red housing on PFLD-2R-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe red housing identifies Line 2 (L2). The source spec sheet associates this colour with NEC - North American, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLD-2R-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-2R-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLD-2R-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLD-2R-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-2R-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a red housing for Line 2 (L2). As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLD-2R-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-2R-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the red housing on PFLD-2R-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The red housing identifies Line 2 (L2). The source spec sheet associates this colour with NEC - North American, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLD-2R-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-2R-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLD-2R-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLD-2R-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLD-2R-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLD-2R-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016052043996,"sku":"PFLD-2R-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLD-2R-C300-C400-M40-M50.jpg?v=1783592450"},{"product_id":"pfld-2w-c300-400-m40-m50","title":"PFLD-2W-C300-400-M40-M50 - PowerFit 800A Line Drain, L2 (Line 2) White","description":"\u003c!-- Combined Shopify product HTML for PFLD-2W-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLD-2W-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLD-2W-C300-400-M40-M50 | PowerFit 800A Line Drain, L2 (Line 2) White (regional phase colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLD-2W-C300-400-M40-M50\" data-color=\"White\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLD-2W-C300-400-M40-M50 is an 800A PowerFit single-pole line drain connector for high-current temporary and permanent power distribution. Its white housing identifies Line 2 (L2), while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLD-2W-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLD-2W-C300-400-M40-M50 | PowerFit 800A Line Drain, L2 (Line 2) White (regional phase colour)\",\n  \"description\": \"KUPO PowerFit 800A Line Drain single-pole connector with white housing for Line 2. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLD-2W-C300-400-M40-M50\",\n  \"mpn\": \"PFLD-2W-C300-400-M40-M50\",\n  \"color\": \"White\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 - Line 2 (regional phase colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"White\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLD-2W-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLD-2W-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-2W-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a white housing for Line 2 (L2). As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLD-2W-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-2W-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the white housing on PFLD-2W-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe white housing identifies Line 2 (L2). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLD-2W-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-2W-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLD-2W-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLD-2W-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-2W-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a white housing for Line 2 (L2). As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLD-2W-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-2W-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the white housing on PFLD-2W-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The white housing identifies Line 2 (L2). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLD-2W-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-2W-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLD-2W-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLD-2W-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLD-2W-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLD-2W-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016060399836,"sku":"PFLD-2W-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLD-2W-C300-C400-M40-M50.jpg?v=1783592455"},{"product_id":"pfld-2y-c300-400-m40-m50","title":"PFLD-2Y-C300-400-M40-M50 - PowerFit 800A Line Drain, L2 (Line 2) Yellow","description":"\u003c!-- Combined Shopify product HTML for PFLD-2Y-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLD-2Y-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLD-2Y-C300-400-M40-M50 | PowerFit 800A Line Drain, L2 (Line 2) Yellow (regional phase colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLD-2Y-C300-400-M40-M50\" data-color=\"Yellow\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLD-2Y-C300-400-M40-M50 is an 800A PowerFit single-pole line drain connector for high-current temporary and permanent power distribution. Its yellow housing identifies Line 2 (L2), while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLD-2Y-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLD-2Y-C300-400-M40-M50 | PowerFit 800A Line Drain, L2 (Line 2) Yellow (regional phase colour)\",\n  \"description\": \"KUPO PowerFit 800A Line Drain single-pole connector with yellow housing for Line 2. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLD-2Y-C300-400-M40-M50\",\n  \"mpn\": \"PFLD-2Y-C300-400-M40-M50\",\n  \"color\": \"Yellow\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 - Line 2 (regional phase colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Yellow\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLD-2Y-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLD-2Y-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-2Y-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a yellow housing for Line 2 (L2). As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLD-2Y-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-2Y-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the yellow housing on PFLD-2Y-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe yellow housing identifies Line 2 (L2). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLD-2Y-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-2Y-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLD-2Y-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLD-2Y-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-2Y-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a yellow housing for Line 2 (L2). As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLD-2Y-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-2Y-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the yellow housing on PFLD-2Y-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The yellow housing identifies Line 2 (L2). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLD-2Y-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-2Y-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLD-2Y-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLD-2Y-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLD-2Y-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLD-2Y-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016068755676,"sku":"PFLD-2Y-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLD-2Y-C300-C400-M40-M50.jpg?v=1783592461"},{"product_id":"pfld-3bl-c300-400-m40-m50","title":"PFLD-3BL-C300-400-M40-M50 - PowerFit 800A Line Drain, L3 (Line 3) Blue","description":"\u003c!-- Combined Shopify product HTML for PFLD-3BL-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLD-3BL-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLD-3BL-C300-400-M40-M50 | PowerFit 800A Line Drain, L3 (Line 3) Blue (IEC \/ regional phase colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLD-3BL-C300-400-M40-M50\" data-color=\"Blue\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLD-3BL-C300-400-M40-M50 is an 800A PowerFit single-pole line drain connector for high-current temporary and permanent power distribution. Its blue housing identifies Line 3 (L3), while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLD-3BL-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLD-3BL-C300-400-M40-M50 | PowerFit 800A Line Drain, L3 (Line 3) Blue (IEC \/ regional phase colour)\",\n  \"description\": \"KUPO PowerFit 800A Line Drain single-pole connector with blue housing for Line 3. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLD-3BL-C300-400-M40-M50\",\n  \"mpn\": \"PFLD-3BL-C300-400-M40-M50\",\n  \"color\": \"Blue\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L3 - Line 3 (IEC \/ regional phase colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Blue\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLD-3BL-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLD-3BL-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-3BL-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a blue housing for Line 3 (L3). As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLD-3BL-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-3BL-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the blue housing on PFLD-3BL-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe blue housing identifies Line 3 (L3). The source spec sheet associates this colour with IEC \/ regional phase colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLD-3BL-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-3BL-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLD-3BL-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLD-3BL-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-3BL-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a blue housing for Line 3 (L3). As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLD-3BL-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-3BL-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the blue housing on PFLD-3BL-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The blue housing identifies Line 3 (L3). The source spec sheet associates this colour with IEC \/ regional phase colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLD-3BL-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-3BL-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLD-3BL-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLD-3BL-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLD-3BL-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLD-3BL-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016077144284,"sku":"PFLD-3BL-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLD-3BL-C300-C400-M40-M50.jpg?v=1783592467"},{"product_id":"pfld-3gy-c300-400-m40-m50","title":"PFLD-3GY-C300-400-M40-M50 - PowerFit 800A Line Drain, L3 (Line 3) Gray","description":"\u003c!-- Combined Shopify product HTML for PFLD-3GY-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLD-3GY-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLD-3GY-C300-400-M40-M50 | PowerFit 800A Line Drain, L3 (Line 3) Gray (regional phase colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLD-3GY-C300-400-M40-M50\" data-color=\"Gray\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLD-3GY-C300-400-M40-M50 is an 800A PowerFit single-pole line drain connector for high-current temporary and permanent power distribution. Its gray housing identifies Line 3 (L3), while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLD-3GY-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLD-3GY-C300-400-M40-M50 | PowerFit 800A Line Drain, L3 (Line 3) Gray (regional phase colour)\",\n  \"description\": \"KUPO PowerFit 800A Line Drain single-pole connector with gray housing for Line 3. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLD-3GY-C300-400-M40-M50\",\n  \"mpn\": \"PFLD-3GY-C300-400-M40-M50\",\n  \"color\": \"Gray\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L3 - Line 3 (regional phase colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Gray\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLD-3GY-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLD-3GY-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-3GY-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a gray housing for Line 3 (L3). As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLD-3GY-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-3GY-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the gray housing on PFLD-3GY-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe gray housing identifies Line 3 (L3). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLD-3GY-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-3GY-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLD-3GY-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLD-3GY-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-3GY-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a gray housing for Line 3 (L3). As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLD-3GY-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-3GY-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the gray housing on PFLD-3GY-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The gray housing identifies Line 3 (L3). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLD-3GY-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-3GY-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLD-3GY-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLD-3GY-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLD-3GY-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLD-3GY-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016085500124,"sku":"PFLD-3GY-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLD-3GY-C300-C400-M40-M50.jpg?v=1783592473"},{"product_id":"pfld-egn-c300-400-m40-m50","title":"PFLD-EGN-C300-400-M40-M50 - PowerFit 800A Line Drain, Earth - Ground Green","description":"\u003c!-- Combined Shopify product HTML for PFLD-EGN-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLD-EGN-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLD-EGN-C300-400-M40-M50 | PowerFit 800A Line Drain, Earth \/ Ground Green (protective earth) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLD-EGN-C300-400-M40-M50\" data-color=\"Green\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLD-EGN-C300-400-M40-M50 is an 800A PowerFit single-pole line drain connector for high-current temporary and permanent power distribution. Its green housing identifies Earth \/ Ground, while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLD-EGN-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLD-EGN-C300-400-M40-M50 | PowerFit 800A Line Drain, Earth \/ Ground Green (protective earth)\",\n  \"description\": \"KUPO PowerFit 800A Line Drain single-pole connector with green housing for Earth \/ Ground. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLD-EGN-C300-400-M40-M50\",\n  \"mpn\": \"PFLD-EGN-C300-400-M40-M50\",\n  \"color\": \"Green\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Earth - Earth \/ Ground (protective earth)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Green\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLD-EGN-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLD-EGN-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-EGN-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a green housing for Earth \/ Ground. As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLD-EGN-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-EGN-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the green housing on PFLD-EGN-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe green housing identifies Earth \/ Ground. The source spec sheet associates this colour with protective earth, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLD-EGN-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-EGN-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLD-EGN-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLD-EGN-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-EGN-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a green housing for Earth \/ Ground. As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLD-EGN-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-EGN-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the green housing on PFLD-EGN-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The green housing identifies Earth \/ Ground. The source spec sheet associates this colour with protective earth, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLD-EGN-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-EGN-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLD-EGN-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLD-EGN-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLD-EGN-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLD-EGN-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016093888732,"sku":"PFLD-EGN-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLD-EGN-C300-C400-M40-M50.jpg?v=1783592479"},{"product_id":"pfld-nbk-c300-400-m40-m50","title":"PFLD-NBK-C300-400-M40-M50 - PowerFit 800A Line Drain, Neutral Black","description":"\u003c!-- Combined Shopify product HTML for PFLD-NBK-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLD-NBK-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLD-NBK-C300-400-M40-M50 | PowerFit 800A Line Drain, Neutral Black (regional neutral colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLD-NBK-C300-400-M40-M50\" data-color=\"Black\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLD-NBK-C300-400-M40-M50 is an 800A PowerFit single-pole line drain connector for high-current temporary and permanent power distribution. Its black housing identifies Neutral, while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLD-NBK-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLD-NBK-C300-400-M40-M50 | PowerFit 800A Line Drain, Neutral Black (regional neutral colour)\",\n  \"description\": \"KUPO PowerFit 800A Line Drain single-pole connector with black housing for Neutral. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLD-NBK-C300-400-M40-M50\",\n  \"mpn\": \"PFLD-NBK-C300-400-M40-M50\",\n  \"color\": \"Black\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Neutral - Neutral (regional neutral colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Black\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLD-NBK-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLD-NBK-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-NBK-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a black housing for Neutral. As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLD-NBK-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-NBK-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the black housing on PFLD-NBK-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe black housing identifies Neutral. The source spec sheet associates this colour with regional neutral colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLD-NBK-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-NBK-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLD-NBK-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLD-NBK-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-NBK-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a black housing for Neutral. As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLD-NBK-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-NBK-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the black housing on PFLD-NBK-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The black housing identifies Neutral. The source spec sheet associates this colour with regional neutral colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLD-NBK-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-NBK-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLD-NBK-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLD-NBK-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLD-NBK-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLD-NBK-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016102244572,"sku":"PFLD-NBK-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLD-NBK-C300-C400-M40-M50.jpg?v=1783592484"},{"product_id":"pfld-nbl-c300-400-m40-m50","title":"PFLD-NBL-C300-400-M40-M50 - PowerFit 800A Line Drain, Neutral Blue","description":"\u003c!-- Combined Shopify product HTML for PFLD-NBL-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLD-NBL-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLD-NBL-C300-400-M40-M50 | PowerFit 800A Line Drain, Neutral Blue (IEC) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLD-NBL-C300-400-M40-M50\" data-color=\"Blue\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLD-NBL-C300-400-M40-M50 is an 800A PowerFit single-pole line drain connector for high-current temporary and permanent power distribution. Its blue housing identifies Neutral, while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLD-NBL-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLD-NBL-C300-400-M40-M50 | PowerFit 800A Line Drain, Neutral Blue (IEC)\",\n  \"description\": \"KUPO PowerFit 800A Line Drain single-pole connector with blue housing for Neutral. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLD-NBL-C300-400-M40-M50\",\n  \"mpn\": \"PFLD-NBL-C300-400-M40-M50\",\n  \"color\": \"Blue\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Neutral - Neutral (IEC)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Blue\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLD-NBL-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLD-NBL-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-NBL-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a blue housing for Neutral. As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLD-NBL-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-NBL-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the blue housing on PFLD-NBL-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe blue housing identifies Neutral. The source spec sheet associates this colour with IEC, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLD-NBL-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-NBL-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLD-NBL-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLD-NBL-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-NBL-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a blue housing for Neutral. As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLD-NBL-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-NBL-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the blue housing on PFLD-NBL-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The blue housing identifies Neutral. The source spec sheet associates this colour with IEC, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLD-NBL-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-NBL-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLD-NBL-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLD-NBL-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLD-NBL-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLD-NBL-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016110665948,"sku":"PFLD-NBL-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLD-NBL-C300-C400-M40-M50.jpg?v=1783592490"},{"product_id":"pfld-nw-c300-400-m40-m50","title":"PFLD-NW-C300-400-M40-M50 - PowerFit 800A Line Drain, Neutral White","description":"\u003c!-- Combined Shopify product HTML for PFLD-NW-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLD-NW-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLD-NW-C300-400-M40-M50 | PowerFit 800A Line Drain, Neutral White (NEC - North American) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLD-NW-C300-400-M40-M50\" data-color=\"White\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLD-NW-C300-400-M40-M50 is an 800A PowerFit single-pole line drain connector for high-current temporary and permanent power distribution. Its white housing identifies Neutral, while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLD-NW-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLD-NW-C300-400-M40-M50 | PowerFit 800A Line Drain, Neutral White (NEC - North American)\",\n  \"description\": \"KUPO PowerFit 800A Line Drain single-pole connector with white housing for Neutral. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLD-NW-C300-400-M40-M50\",\n  \"mpn\": \"PFLD-NW-C300-400-M40-M50\",\n  \"color\": \"White\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Neutral - Neutral (NEC - North American)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"White\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLD-NW-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLD-NW-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-NW-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a white housing for Neutral. As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLD-NW-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-NW-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the white housing on PFLD-NW-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe white housing identifies Neutral. The source spec sheet associates this colour with NEC - North American, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLD-NW-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-NW-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLD-NW-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLD-NW-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-NW-C300-400-M40-M50 is a KUPO PowerFit 800A line drain connector with a white housing for Neutral. As an inline drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLD-NW-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-NW-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the white housing on PFLD-NW-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The white housing identifies Neutral. The source spec sheet associates this colour with NEC - North American, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLD-NW-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-NW-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist connection interface. O-ring sealing supports IP67 protection after mating.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLD-NW-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLD-NW-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLD-NW-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLD-NW-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016119120092,"sku":"PFLD-NW-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLD-NW-C300-C400-M40-M50.jpg?v=1783592496"},{"product_id":"pfls-1bk-c300-400-m40-m50","title":"PFLS-1BK-C300-400-M40-M50 - PowerFit 800A Line Source, L1 (Line 1) Black","description":"\u003c!-- Combined Shopify product HTML for PFLS-1BK-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLS-1BK-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLS-1BK-C300-400-M40-M50 | PowerFit 800A Line Source, L1 (Line 1) Black (NEC - North American) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLS-1BK-C300-400-M40-M50\" data-color=\"Black\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLS-1BK-C300-400-M40-M50 is an 800A PowerFit single-pole line source connector for high-current temporary and permanent power distribution. Its black housing identifies Line 1 (L1), while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eInnovative key-release pin allows for fast and convenient disconnection\u003c\/li\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-1BK-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLS-1BK-C300-400-M40-M50 | PowerFit 800A Line Source, L1 (Line 1) Black (NEC - North American)\",\n  \"description\": \"KUPO PowerFit 800A Line Source single-pole connector with black housing for Line 1. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLS-1BK-C300-400-M40-M50\",\n  \"mpn\": \"PFLS-1BK-C300-400-M40-M50\",\n  \"color\": \"Black\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5kA\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Source\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist with key release mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L1 - Line 1 (NEC - North American)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Black\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLS-1BK-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLS-1BK-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-1BK-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a black housing for Line 1 (L1). As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLS-1BK-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-1BK-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the black housing on PFLS-1BK-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe black housing identifies Line 1 (L1). The source spec sheet associates this colour with NEC - North American, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLS-1BK-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-1BK-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLS-1BK-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLS-1BK-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-1BK-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a black housing for Line 1 (L1). As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLS-1BK-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-1BK-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the black housing on PFLS-1BK-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The black housing identifies Line 1 (L1). The source spec sheet associates this colour with NEC - North American, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLS-1BK-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-1BK-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLS-1BK-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLS-1BK-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLS-1BK-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLS-1BK-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016127574236,"sku":"PFLS-1BK-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLS-1BK-C300-C400-M40-M50.jpg?v=1783592502"},{"product_id":"pfls-1bn-c300-400-m40-m50","title":"PFLS-1BN-C300-400-M40-M50 - PowerFit 800A Line Source, L1 (Line 1) Brown","description":"\u003c!-- Combined Shopify product HTML for PFLS-1BN-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLS-1BN-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLS-1BN-C300-400-M40-M50 | PowerFit 800A Line Source, L1 (Line 1) Brown (IEC) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLS-1BN-C300-400-M40-M50\" data-color=\"Brown\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLS-1BN-C300-400-M40-M50 is an 800A PowerFit single-pole line source connector for high-current temporary and permanent power distribution. Its brown housing identifies Line 1 (L1), while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eInnovative key-release pin allows for fast and convenient disconnection\u003c\/li\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-1BN-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLS-1BN-C300-400-M40-M50 | PowerFit 800A Line Source, L1 (Line 1) Brown (IEC)\",\n  \"description\": \"KUPO PowerFit 800A Line Source single-pole connector with brown housing for Line 1. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLS-1BN-C300-400-M40-M50\",\n  \"mpn\": \"PFLS-1BN-C300-400-M40-M50\",\n  \"color\": \"Brown\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5kA\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Source\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist with key release mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L1 - Line 1 (IEC)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Brown\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLS-1BN-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLS-1BN-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-1BN-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a brown housing for Line 1 (L1). As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLS-1BN-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-1BN-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the brown housing on PFLS-1BN-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe brown housing identifies Line 1 (L1). The source spec sheet associates this colour with IEC, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLS-1BN-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-1BN-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLS-1BN-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLS-1BN-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-1BN-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a brown housing for Line 1 (L1). As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLS-1BN-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-1BN-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the brown housing on PFLS-1BN-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The brown housing identifies Line 1 (L1). The source spec sheet associates this colour with IEC, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLS-1BN-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-1BN-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLS-1BN-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLS-1BN-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLS-1BN-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLS-1BN-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016135930076,"sku":"PFLS-1BN-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLS-1BN-C300-C400-M40-M50.jpg?v=1783592509"},{"product_id":"pfls-1r-c300-400-m40-m50","title":"PFLS-1R-C300-400-M40-M50 - PowerFit 800A Line Source, L1 (Line 1) Red","description":"\u003c!-- Combined Shopify product HTML for PFLS-1R-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLS-1R-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLS-1R-C300-400-M40-M50 | PowerFit 800A Line Source, L1 (Line 1) Red (regional phase colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLS-1R-C300-400-M40-M50\" data-color=\"Red\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLS-1R-C300-400-M40-M50 is an 800A PowerFit single-pole line source connector for high-current temporary and permanent power distribution. Its red housing identifies Line 1 (L1), while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eInnovative key-release pin allows for fast and convenient disconnection\u003c\/li\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-1R-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLS-1R-C300-400-M40-M50 | PowerFit 800A Line Source, L1 (Line 1) Red (regional phase colour)\",\n  \"description\": \"KUPO PowerFit 800A Line Source single-pole connector with red housing for Line 1. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLS-1R-C300-400-M40-M50\",\n  \"mpn\": \"PFLS-1R-C300-400-M40-M50\",\n  \"color\": \"Red\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5kA\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Source\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist with key release mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L1 - Line 1 (regional phase colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Red\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLS-1R-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLS-1R-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-1R-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a red housing for Line 1 (L1). As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLS-1R-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-1R-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the red housing on PFLS-1R-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe red housing identifies Line 1 (L1). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLS-1R-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-1R-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLS-1R-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLS-1R-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-1R-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a red housing for Line 1 (L1). As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLS-1R-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-1R-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the red housing on PFLS-1R-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The red housing identifies Line 1 (L1). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLS-1R-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-1R-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLS-1R-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLS-1R-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLS-1R-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLS-1R-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016144318684,"sku":"PFLS-1R-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLS-1R-C300-C400-M40-M50.jpg?v=1783592514"},{"product_id":"pfls-2bk-c300-400-m40-m50","title":"PFLS-2BK-C300-400-M40-M50 - PowerFit 800A Line Source, L2 (Line 2) Black","description":"\u003c!-- Combined Shopify product HTML for PFLS-2BK-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLS-2BK-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLS-2BK-C300-400-M40-M50 | PowerFit 800A Line Source, L2 (Line 2) Black (regional phase colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLS-2BK-C300-400-M40-M50\" data-color=\"Black\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLS-2BK-C300-400-M40-M50 is an 800A PowerFit single-pole line source connector for high-current temporary and permanent power distribution. Its black housing identifies Line 2 (L2), while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eInnovative key-release pin allows for fast and convenient disconnection\u003c\/li\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-2BK-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLS-2BK-C300-400-M40-M50 | PowerFit 800A Line Source, L2 (Line 2) Black (regional phase colour)\",\n  \"description\": \"KUPO PowerFit 800A Line Source single-pole connector with black housing for Line 2. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLS-2BK-C300-400-M40-M50\",\n  \"mpn\": \"PFLS-2BK-C300-400-M40-M50\",\n  \"color\": \"Black\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5kA\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Source\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist with key release mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 - Line 2 (regional phase colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Black\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLS-2BK-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLS-2BK-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2BK-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a black housing for Line 2 (L2). As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLS-2BK-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2BK-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the black housing on PFLS-2BK-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe black housing identifies Line 2 (L2). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLS-2BK-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2BK-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLS-2BK-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLS-2BK-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2BK-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a black housing for Line 2 (L2). As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLS-2BK-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2BK-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the black housing on PFLS-2BK-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The black housing identifies Line 2 (L2). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLS-2BK-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2BK-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLS-2BK-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLS-2BK-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLS-2BK-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLS-2BK-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016152740060,"sku":"PFLS-2BK-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLS-2BK-C300-C400-M40-M50.jpg?v=1783592520"},{"product_id":"pfls-2r-c300-400-m40-m50","title":"PFLS-2R-C300-400-M40-M50 - PowerFit 800A Line Source, L2 (Line 2) Red","description":"\u003c!-- Combined Shopify product HTML for PFLS-2R-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLS-2R-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLS-2R-C300-400-M40-M50 | PowerFit 800A Line Source, L2 (Line 2) Red (NEC - North American) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLS-2R-C300-400-M40-M50\" data-color=\"Red\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLS-2R-C300-400-M40-M50 is an 800A PowerFit single-pole line source connector for high-current temporary and permanent power distribution. Its red housing identifies Line 2 (L2), while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eInnovative key-release pin allows for fast and convenient disconnection\u003c\/li\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-2R-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLS-2R-C300-400-M40-M50 | PowerFit 800A Line Source, L2 (Line 2) Red (NEC - North American)\",\n  \"description\": \"KUPO PowerFit 800A Line Source single-pole connector with red housing for Line 2. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLS-2R-C300-400-M40-M50\",\n  \"mpn\": \"PFLS-2R-C300-400-M40-M50\",\n  \"color\": \"Red\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5kA\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Source\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist with key release mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 - Line 2 (NEC - North American)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Red\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLS-2R-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLS-2R-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2R-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a red housing for Line 2 (L2). As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLS-2R-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2R-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the red housing on PFLS-2R-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe red housing identifies Line 2 (L2). The source spec sheet associates this colour with NEC - North American, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLS-2R-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2R-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLS-2R-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLS-2R-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2R-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a red housing for Line 2 (L2). As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLS-2R-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2R-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the red housing on PFLS-2R-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The red housing identifies Line 2 (L2). The source spec sheet associates this colour with NEC - North American, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLS-2R-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2R-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLS-2R-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLS-2R-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLS-2R-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLS-2R-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016161095900,"sku":"PFLS-2R-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLS-2R-C300-C400-M40-M50.jpg?v=1783592526"},{"product_id":"pfls-2w-c300-400-m40-m50","title":"PFLS-2W-C300-400-M40-M50 - PowerFit 800A Line Source, L2 (Line 2) White","description":"\u003c!-- Combined Shopify product HTML for PFLS-2W-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLS-2W-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLS-2W-C300-400-M40-M50 | PowerFit 800A Line Source, L2 (Line 2) White (regional phase colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLS-2W-C300-400-M40-M50\" data-color=\"White\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLS-2W-C300-400-M40-M50 is an 800A PowerFit single-pole line source connector for high-current temporary and permanent power distribution. Its white housing identifies Line 2 (L2), while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eInnovative key-release pin allows for fast and convenient disconnection\u003c\/li\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-2W-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLS-2W-C300-400-M40-M50 | PowerFit 800A Line Source, L2 (Line 2) White (regional phase colour)\",\n  \"description\": \"KUPO PowerFit 800A Line Source single-pole connector with white housing for Line 2. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLS-2W-C300-400-M40-M50\",\n  \"mpn\": \"PFLS-2W-C300-400-M40-M50\",\n  \"color\": \"White\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5kA\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Source\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist with key release mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 - Line 2 (regional phase colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"White\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLS-2W-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLS-2W-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2W-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a white housing for Line 2 (L2). As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLS-2W-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2W-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the white housing on PFLS-2W-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe white housing identifies Line 2 (L2). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLS-2W-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2W-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLS-2W-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLS-2W-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2W-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a white housing for Line 2 (L2). As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLS-2W-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2W-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the white housing on PFLS-2W-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The white housing identifies Line 2 (L2). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLS-2W-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2W-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLS-2W-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLS-2W-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLS-2W-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLS-2W-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016169451740,"sku":"PFLS-2W-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLS-2W-C300-C400-M40-M50.jpg?v=1783592532"},{"product_id":"pfls-2y-c300-400-m40-m50","title":"PFLS-2Y-C300-400-M40-M50 - PowerFit 800A Line Source, L2 (Line 2) Yellow","description":"\u003c!-- Combined Shopify product HTML for PFLS-2Y-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLS-2Y-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLS-2Y-C300-400-M40-M50 | PowerFit 800A Line Source, L2 (Line 2) Yellow (regional phase colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLS-2Y-C300-400-M40-M50\" data-color=\"Yellow\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLS-2Y-C300-400-M40-M50 is an 800A PowerFit single-pole line source connector for high-current temporary and permanent power distribution. Its yellow housing identifies Line 2 (L2), while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eInnovative key-release pin allows for fast and convenient disconnection\u003c\/li\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-2Y-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLS-2Y-C300-400-M40-M50 | PowerFit 800A Line Source, L2 (Line 2) Yellow (regional phase colour)\",\n  \"description\": \"KUPO PowerFit 800A Line Source single-pole connector with yellow housing for Line 2. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLS-2Y-C300-400-M40-M50\",\n  \"mpn\": \"PFLS-2Y-C300-400-M40-M50\",\n  \"color\": \"Yellow\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5kA\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Source\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist with key release mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 - Line 2 (regional phase colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Yellow\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLS-2Y-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLS-2Y-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2Y-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a yellow housing for Line 2 (L2). As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLS-2Y-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2Y-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the yellow housing on PFLS-2Y-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe yellow housing identifies Line 2 (L2). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLS-2Y-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2Y-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLS-2Y-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLS-2Y-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2Y-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a yellow housing for Line 2 (L2). As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLS-2Y-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2Y-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the yellow housing on PFLS-2Y-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The yellow housing identifies Line 2 (L2). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLS-2Y-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2Y-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLS-2Y-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLS-2Y-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLS-2Y-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLS-2Y-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016177840348,"sku":"PFLS-2Y-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLS-2Y-C300-C400-M40-M50.jpg?v=1783592540"},{"product_id":"pfls-3bl-c300-400-m40-m50","title":"PFLS-3BL-C300-400-M40-M50 - PowerFit 800A Line Source, L3 (Line 3) Blue","description":"\u003c!-- Combined Shopify product HTML for PFLS-3BL-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLS-3BL-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLS-3BL-C300-400-M40-M50 | PowerFit 800A Line Source, L3 (Line 3) Blue (IEC \/ regional phase colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLS-3BL-C300-400-M40-M50\" data-color=\"Blue\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLS-3BL-C300-400-M40-M50 is an 800A PowerFit single-pole line source connector for high-current temporary and permanent power distribution. Its blue housing identifies Line 3 (L3), while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eInnovative key-release pin allows for fast and convenient disconnection\u003c\/li\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-3BL-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLS-3BL-C300-400-M40-M50 | PowerFit 800A Line Source, L3 (Line 3) Blue (IEC \/ regional phase colour)\",\n  \"description\": \"KUPO PowerFit 800A Line Source single-pole connector with blue housing for Line 3. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLS-3BL-C300-400-M40-M50\",\n  \"mpn\": \"PFLS-3BL-C300-400-M40-M50\",\n  \"color\": \"Blue\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5kA\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Source\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist with key release mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L3 - Line 3 (IEC \/ regional phase colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Blue\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLS-3BL-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLS-3BL-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-3BL-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a blue housing for Line 3 (L3). As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLS-3BL-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-3BL-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the blue housing on PFLS-3BL-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe blue housing identifies Line 3 (L3). The source spec sheet associates this colour with IEC \/ regional phase colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLS-3BL-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-3BL-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLS-3BL-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLS-3BL-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-3BL-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a blue housing for Line 3 (L3). As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLS-3BL-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-3BL-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the blue housing on PFLS-3BL-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The blue housing identifies Line 3 (L3). The source spec sheet associates this colour with IEC \/ regional phase colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLS-3BL-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-3BL-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLS-3BL-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLS-3BL-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLS-3BL-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLS-3BL-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016178135260,"sku":"PFLS-3BL-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLS-3BL-C300-C400-M40-M50.jpg?v=1783592546"},{"product_id":"pfls-3gy-c300-400-m40-m50","title":"PFLS-3GY-C300-400-M40-M50 - PowerFit 800A Line Source, L3 (Line 3) Gray","description":"\u003c!-- Combined Shopify product HTML for PFLS-3GY-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLS-3GY-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLS-3GY-C300-400-M40-M50 | PowerFit 800A Line Source, L3 (Line 3) Gray (regional phase colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLS-3GY-C300-400-M40-M50\" data-color=\"Gray\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLS-3GY-C300-400-M40-M50 is an 800A PowerFit single-pole line source connector for high-current temporary and permanent power distribution. Its gray housing identifies Line 3 (L3), while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eInnovative key-release pin allows for fast and convenient disconnection\u003c\/li\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-3GY-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLS-3GY-C300-400-M40-M50 | PowerFit 800A Line Source, L3 (Line 3) Gray (regional phase colour)\",\n  \"description\": \"KUPO PowerFit 800A Line Source single-pole connector with gray housing for Line 3. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLS-3GY-C300-400-M40-M50\",\n  \"mpn\": \"PFLS-3GY-C300-400-M40-M50\",\n  \"color\": \"Gray\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Source\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist with key release mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L3 - Line 3 (regional phase colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Gray\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLS-3GY-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLS-3GY-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-3GY-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a gray housing for Line 3 (L3). As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLS-3GY-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-3GY-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the gray housing on PFLS-3GY-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe gray housing identifies Line 3 (L3). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLS-3GY-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-3GY-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLS-3GY-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLS-3GY-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-3GY-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a gray housing for Line 3 (L3). As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLS-3GY-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-3GY-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the gray housing on PFLS-3GY-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The gray housing identifies Line 3 (L3). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLS-3GY-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-3GY-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLS-3GY-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLS-3GY-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLS-3GY-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLS-3GY-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016178430172,"sku":"PFLS-3GY-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLS-3GY-C300-C400-M40-M50.jpg?v=1783592552"},{"product_id":"pfls-egn-c300-400-m40-m50","title":"PFLS-EGN-C300-400-M40-M50 - PowerFit 800A Line Source, Earth - Ground Green","description":"\u003c!-- Combined Shopify product HTML for PFLS-EGN-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLS-EGN-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLS-EGN-C300-400-M40-M50 | PowerFit 800A Line Source, Earth \/ Ground Green (protective earth) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLS-EGN-C300-400-M40-M50\" data-color=\"Green\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLS-EGN-C300-400-M40-M50 is an 800A PowerFit single-pole line source connector for high-current temporary and permanent power distribution. Its green housing identifies Earth \/ Ground, while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eInnovative key-release pin allows for fast and convenient disconnection\u003c\/li\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-EGN-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLS-EGN-C300-400-M40-M50 | PowerFit 800A Line Source, Earth \/ Ground Green (protective earth)\",\n  \"description\": \"KUPO PowerFit 800A Line Source single-pole connector with green housing for Earth \/ Ground. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLS-EGN-C300-400-M40-M50\",\n  \"mpn\": \"PFLS-EGN-C300-400-M40-M50\",\n  \"color\": \"Green\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5kA\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Source\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist with key release mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Earth - Earth \/ Ground (protective earth)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Green\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLS-EGN-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLS-EGN-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-EGN-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a green housing for Earth \/ Ground. As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLS-EGN-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-EGN-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the green housing on PFLS-EGN-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe green housing identifies Earth \/ Ground. The source spec sheet associates this colour with protective earth, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLS-EGN-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-EGN-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLS-EGN-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLS-EGN-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-EGN-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a green housing for Earth \/ Ground. As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLS-EGN-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-EGN-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the green housing on PFLS-EGN-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The green housing identifies Earth \/ Ground. The source spec sheet associates this colour with protective earth, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLS-EGN-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-EGN-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLS-EGN-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLS-EGN-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLS-EGN-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLS-EGN-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016178659548,"sku":"PFLS-EGN-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLS-EGN-C300-C400-M40-M50.jpg?v=1783592558"},{"product_id":"pfls-nbk-c300-400-m40-m50","title":"PFLS-NBK-C300-400-M40-M50 - PowerFit 800A Line Source, Neutral Black","description":"\u003c!-- Combined Shopify product HTML for PFLS-NBK-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLS-NBK-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLS-NBK-C300-400-M40-M50 | PowerFit 800A Line Source, Neutral Black (regional neutral colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLS-NBK-C300-400-M40-M50\" data-color=\"Black\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLS-NBK-C300-400-M40-M50 is an 800A PowerFit single-pole line source connector for high-current temporary and permanent power distribution. Its black housing identifies Neutral, while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eInnovative key-release pin allows for fast and convenient disconnection\u003c\/li\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-NBK-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLS-NBK-C300-400-M40-M50 | PowerFit 800A Line Source, Neutral Black (regional neutral colour)\",\n  \"description\": \"KUPO PowerFit 800A Line Source single-pole connector with black housing for Neutral. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLS-NBK-C300-400-M40-M50\",\n  \"mpn\": \"PFLS-NBK-C300-400-M40-M50\",\n  \"color\": \"Black\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Source\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist with key release mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Neutral - Neutral (regional neutral colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Black\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLS-NBK-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLS-NBK-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-NBK-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a black housing for Neutral. As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLS-NBK-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-NBK-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the black housing on PFLS-NBK-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe black housing identifies Neutral. The source spec sheet associates this colour with regional neutral colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLS-NBK-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-NBK-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLS-NBK-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLS-NBK-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-NBK-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a black housing for Neutral. As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLS-NBK-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-NBK-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the black housing on PFLS-NBK-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The black housing identifies Neutral. The source spec sheet associates this colour with regional neutral colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLS-NBK-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-NBK-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLS-NBK-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLS-NBK-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLS-NBK-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLS-NBK-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016178888924,"sku":"PFLS-NBK-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLS-NBK-C300-C400-M40-M50.jpg?v=1783592564"},{"product_id":"pfls-nbl-c300-400-m40-m50","title":"PFLS-NBL-C300-400-M40-M50 - PowerFit 800A Line Source, Neutral Blue","description":"\u003c!-- Combined Shopify product HTML for PFLS-NBL-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLS-NBL-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLS-NBL-C300-400-M40-M50 | PowerFit 800A Line Source, Neutral Blue (IEC) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLS-NBL-C300-400-M40-M50\" data-color=\"Blue\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLS-NBL-C300-400-M40-M50 is an 800A PowerFit single-pole line source connector for high-current temporary and permanent power distribution. Its blue housing identifies Neutral, while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eInnovative key-release pin allows for fast and convenient disconnection\u003c\/li\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-NBL-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLS-NBL-C300-400-M40-M50 | PowerFit 800A Line Source, Neutral Blue (IEC)\",\n  \"description\": \"KUPO PowerFit 800A Line Source single-pole connector with blue housing for Neutral. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLS-NBL-C300-400-M40-M50\",\n  \"mpn\": \"PFLS-NBL-C300-400-M40-M50\",\n  \"color\": \"Blue\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5kA\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Source\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist with key release mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Neutral - Neutral (IEC)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Blue\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLS-NBL-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLS-NBL-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-NBL-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a blue housing for Neutral. As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLS-NBL-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-NBL-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the blue housing on PFLS-NBL-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe blue housing identifies Neutral. The source spec sheet associates this colour with IEC, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLS-NBL-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-NBL-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLS-NBL-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLS-NBL-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-NBL-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a blue housing for Neutral. As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLS-NBL-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-NBL-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the blue housing on PFLS-NBL-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The blue housing identifies Neutral. The source spec sheet associates this colour with IEC, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLS-NBL-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-NBL-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLS-NBL-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLS-NBL-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLS-NBL-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLS-NBL-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016178954460,"sku":"PFLS-NBL-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLS-NBL-C300-C400-M40-M50.jpg?v=1783592570"},{"product_id":"pfls-nw-c300-400-m40-m50","title":"PFLS-NW-C300-400-M40-M50 - PowerFit 800A Line Source, Neutral White","description":"\u003c!-- Combined Shopify product HTML for PFLS-NW-C300-400-M40-M50 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLS-NW-C300-400-M40-M50\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFLS-NW-C300-400-M40-M50 | PowerFit 800A Line Source, Neutral White (NEC - North American) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLS-NW-C300-400-M40-M50\" data-color=\"White\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLS-NW-C300-400-M40-M50 is an 800A PowerFit single-pole line source connector for high-current temporary and permanent power distribution. Its white housing identifies Neutral, while the crimp (for 400mm2 cable) termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eInnovative key-release pin allows for fast and convenient disconnection\u003c\/li\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eM40*1.5 cable gland with rubber bushing for secure IP67-rated sealing\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-NW-C300-400-M40-M50 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLS-NW-C300-400-M40-M50 | PowerFit 800A Line Source, Neutral White (NEC - North American)\",\n  \"description\": \"KUPO PowerFit 800A Line Source single-pole connector with white housing for Neutral. Crimp (for 400mm2 cable) termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLS-NW-C300-400-M40-M50\",\n  \"mpn\": \"PFLS-NW-C300-400-M40-M50\",\n  \"color\": \"White\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Source\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist with key release mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"Crimp (for 400mm2 cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Neutral - Neutral (NEC - North American)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"White\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLS-NW-C300-400-M40-M50\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFLS-NW-C300-400-M40-M50 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-NW-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a white housing for Neutral. As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFLS-NW-C300-400-M40-M50 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-NW-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the white housing on PFLS-NW-C300-400-M40-M50 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe white housing identifies Neutral. The source spec sheet associates this colour with NEC - North American, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLS-NW-C300-400-M40-M50 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-NW-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFLS-NW-C300-400-M40-M50?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFLS-NW-C300-400-M40-M50 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-NW-C300-400-M40-M50 is a KUPO PowerFit 800A line source connector with a white housing for Neutral. As an inline source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFLS-NW-C300-400-M40-M50 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-NW-C300-400-M40-M50 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the white housing on PFLS-NW-C300-400-M40-M50 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The white housing identifies Neutral. The source spec sheet associates this colour with NEC - North American, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLS-NW-C300-400-M40-M50 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-NW-C300-400-M40-M50 uses crimp (for 400mm2 cable) contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports fast and controlled disconnection.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFLS-NW-C300-400-M40-M50?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLS-NW-C300-400-M40-M50\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLS-NW-C300-400-M40-M50.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLS-NW-C300-400-M40-M50 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Inline Connector","offer_id":52016179151068,"sku":"PFLS-NW-C300-400-M40-M50","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLS-NW-C300-C400-M40-M50.jpg?v=1783592576"},{"product_id":"pfpd-1bk-t8","title":"PFPD-1BK-T8 - PowerFit 800A Panel Drain, L1 (Line 1) Black","description":"\u003c!-- Combined Shopify product HTML for PFPD-1BK-T8 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPD-1BK-T8\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFPD-1BK-T8 | PowerFit 800A Panel Drain, L1 (Line 1) Black (NEC - North American) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPD-1BK-T8\" data-color=\"Black\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFPD-1BK-T8 is an 800A PowerFit single-pole panel drain connector for high-current temporary and permanent power distribution. Its black housing identifies Line 1 (L1), while the m12 threaded post termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eSilver-plated contact ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFPD-1BK-T8 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPD-1BK-T8 | PowerFit 800A Panel Drain, L1 (Line 1) Black (NEC - North American)\",\n  \"description\": \"KUPO PowerFit 800A Panel Drain single-pole connector with black housing for Line 1. M12 threaded post termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFPD-1BK-T8\",\n  \"mpn\": \"PFPD-1BK-T8\",\n  \"color\": \"Black\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5kA\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"M12 threaded post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Maximum 12-14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L1 - Line 1 (NEC - North American)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Black\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPD-1BK-T8\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFPD-1BK-T8 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-1BK-T8 is a KUPO PowerFit 800A panel drain connector with a black housing for Line 1 (L1). As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFPD-1BK-T8 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-1BK-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the black housing on PFPD-1BK-T8 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe black housing identifies Line 1 (L1). The source spec sheet associates this colour with NEC - North American, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPD-1BK-T8 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-1BK-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFPD-1BK-T8?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFPD-1BK-T8 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-1BK-T8 is a KUPO PowerFit 800A panel drain connector with a black housing for Line 1 (L1). As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFPD-1BK-T8 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-1BK-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the black housing on PFPD-1BK-T8 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The black housing identifies Line 1 (L1). The source spec sheet associates this colour with NEC - North American, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPD-1BK-T8 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-1BK-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFPD-1BK-T8?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPD-1BK-T8\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPD-1BK-T8.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPD-1BK-T8 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Panel Mount Receptacle","offer_id":52016179347676,"sku":"PFPD-1BK-T8","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPD-1BK-T8.jpg?v=1783592581"},{"product_id":"pfpd-1bn-t8","title":"PFPD-1BN-T8 - PowerFit 800A Panel Drain, L1 (Line 1) Brown","description":"\u003c!-- Combined Shopify product HTML for PFPD-1BN-T8 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPD-1BN-T8\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFPD-1BN-T8 | PowerFit 800A Panel Drain, L1 (Line 1) Brown (IEC) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPD-1BN-T8\" data-color=\"Brown\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFPD-1BN-T8 is an 800A PowerFit single-pole panel drain connector for high-current temporary and permanent power distribution. Its brown housing identifies Line 1 (L1), while the m12 threaded post termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eSilver-plated contact ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFPD-1BN-T8 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPD-1BN-T8 | PowerFit 800A Panel Drain, L1 (Line 1) Brown (IEC)\",\n  \"description\": \"KUPO PowerFit 800A Panel Drain single-pole connector with brown housing for Line 1. M12 threaded post termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFPD-1BN-T8\",\n  \"mpn\": \"PFPD-1BN-T8\",\n  \"color\": \"Brown\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5kA\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"M12 threaded post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Maximum 12-14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L1 - Line 1 (IEC)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Brown\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPD-1BN-T8\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFPD-1BN-T8 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-1BN-T8 is a KUPO PowerFit 800A panel drain connector with a brown housing for Line 1 (L1). As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFPD-1BN-T8 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-1BN-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the brown housing on PFPD-1BN-T8 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe brown housing identifies Line 1 (L1). The source spec sheet associates this colour with IEC, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPD-1BN-T8 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-1BN-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFPD-1BN-T8?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFPD-1BN-T8 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-1BN-T8 is a KUPO PowerFit 800A panel drain connector with a brown housing for Line 1 (L1). As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFPD-1BN-T8 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-1BN-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the brown housing on PFPD-1BN-T8 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The brown housing identifies Line 1 (L1). The source spec sheet associates this colour with IEC, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPD-1BN-T8 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-1BN-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFPD-1BN-T8?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPD-1BN-T8\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPD-1BN-T8.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPD-1BN-T8 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Panel Mount Receptacle","offer_id":52016179544284,"sku":"PFPD-1BN-T8","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPD-1BN-T8.jpg?v=1783592587"},{"product_id":"pfpd-1r-t8","title":"PFPD-1R-T8 - PowerFit 800A Panel Drain, L1 (Line 1) Red","description":"\u003c!-- Combined Shopify product HTML for PFPD-1R-T8 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPD-1R-T8\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFPD-1R-T8 | PowerFit 800A Panel Drain, L1 (Line 1) Red (regional phase colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPD-1R-T8\" data-color=\"Red\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFPD-1R-T8 is an 800A PowerFit single-pole panel drain connector for high-current temporary and permanent power distribution. Its red housing identifies Line 1 (L1), while the m12 threaded post termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eSilver-plated contact ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFPD-1R-T8 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPD-1R-T8 | PowerFit 800A Panel Drain, L1 (Line 1) Red (regional phase colour)\",\n  \"description\": \"KUPO PowerFit 800A Panel Drain single-pole connector with red housing for Line 1. M12 threaded post termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFPD-1R-T8\",\n  \"mpn\": \"PFPD-1R-T8\",\n  \"color\": \"Red\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"M12 threaded post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Maximum 12-14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L1 - Line 1 (regional phase colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Red\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPD-1R-T8\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFPD-1R-T8 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-1R-T8 is a KUPO PowerFit 800A panel drain connector with a red housing for Line 1 (L1). As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFPD-1R-T8 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-1R-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the red housing on PFPD-1R-T8 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe red housing identifies Line 1 (L1). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPD-1R-T8 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-1R-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFPD-1R-T8?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFPD-1R-T8 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-1R-T8 is a KUPO PowerFit 800A panel drain connector with a red housing for Line 1 (L1). As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFPD-1R-T8 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-1R-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the red housing on PFPD-1R-T8 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The red housing identifies Line 1 (L1). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPD-1R-T8 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-1R-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFPD-1R-T8?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPD-1R-T8\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPD-1R-T8.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPD-1R-T8 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Panel Mount Receptacle","offer_id":52016179740892,"sku":"PFPD-1R-T8","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPD-1R-T8.jpg?v=1783592593"},{"product_id":"pfpd-2bk-t8","title":"PFPD-2BK-T8 - PowerFit 800A Panel Drain, L2 (Line 2) Black","description":"\u003c!-- Combined Shopify product HTML for PFPD-2BK-T8 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPD-2BK-T8\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFPD-2BK-T8 | PowerFit 800A Panel Drain, L2 (Line 2) Black (regional phase colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPD-2BK-T8\" data-color=\"Black\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFPD-2BK-T8 is an 800A PowerFit single-pole panel drain connector for high-current temporary and permanent power distribution. Its black housing identifies Line 2 (L2), while the m12 threaded post termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eSilver-plated contact ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFPD-2BK-T8 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPD-2BK-T8 | PowerFit 800A Panel Drain, L2 (Line 2) Black (regional phase colour)\",\n  \"description\": \"KUPO PowerFit 800A Panel Drain single-pole connector with black housing for Line 2. M12 threaded post termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFPD-2BK-T8\",\n  \"mpn\": \"PFPD-2BK-T8\",\n  \"color\": \"Black\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"M12 threaded post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Maximum 12-14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 - Line 2 (regional phase colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Black\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPD-2BK-T8\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFPD-2BK-T8 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2BK-T8 is a KUPO PowerFit 800A panel drain connector with a black housing for Line 2 (L2). As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFPD-2BK-T8 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2BK-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the black housing on PFPD-2BK-T8 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe black housing identifies Line 2 (L2). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPD-2BK-T8 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2BK-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFPD-2BK-T8?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFPD-2BK-T8 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2BK-T8 is a KUPO PowerFit 800A panel drain connector with a black housing for Line 2 (L2). As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFPD-2BK-T8 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2BK-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the black housing on PFPD-2BK-T8 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The black housing identifies Line 2 (L2). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPD-2BK-T8 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2BK-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFPD-2BK-T8?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPD-2BK-T8\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPD-2BK-T8.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPD-2BK-T8 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Panel Mount Receptacle","offer_id":52016179937500,"sku":"PFPD-2BK-T8","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPD-2BK-T8.jpg?v=1783592599"},{"product_id":"pfpd-2r-t8","title":"PFPD-2R-T8 - PowerFit 800A Panel Drain, L2 (Line 2) Red","description":"\u003c!-- Combined Shopify product HTML for PFPD-2R-T8 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPD-2R-T8\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFPD-2R-T8 | PowerFit 800A Panel Drain, L2 (Line 2) Red (NEC - North American) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPD-2R-T8\" data-color=\"Red\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFPD-2R-T8 is an 800A PowerFit single-pole panel drain connector for high-current temporary and permanent power distribution. Its red housing identifies Line 2 (L2), while the m12 threaded post termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eSilver-plated contact ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFPD-2R-T8 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPD-2R-T8 | PowerFit 800A Panel Drain, L2 (Line 2) Red (NEC - North American)\",\n  \"description\": \"KUPO PowerFit 800A Panel Drain single-pole connector with red housing for Line 2. M12 threaded post termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFPD-2R-T8\",\n  \"mpn\": \"PFPD-2R-T8\",\n  \"color\": \"Red\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"M12 threaded post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Maximum 12-14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 - Line 2 (NEC - North American)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Red\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPD-2R-T8\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFPD-2R-T8 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2R-T8 is a KUPO PowerFit 800A panel drain connector with a red housing for Line 2 (L2). As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFPD-2R-T8 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2R-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the red housing on PFPD-2R-T8 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe red housing identifies Line 2 (L2). The source spec sheet associates this colour with NEC - North American, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPD-2R-T8 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2R-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFPD-2R-T8?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFPD-2R-T8 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2R-T8 is a KUPO PowerFit 800A panel drain connector with a red housing for Line 2 (L2). As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFPD-2R-T8 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2R-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the red housing on PFPD-2R-T8 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The red housing identifies Line 2 (L2). The source spec sheet associates this colour with NEC - North American, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPD-2R-T8 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2R-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFPD-2R-T8?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPD-2R-T8\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPD-2R-T8.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPD-2R-T8 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Panel Mount Receptacle","offer_id":52016188227804,"sku":"PFPD-2R-T8","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPD-2R-T8.jpg?v=1783592605"},{"product_id":"pfpd-2w-t8","title":"PFPD-2W-T8 - PowerFit 800A Panel Drain, L2 (Line 2) White","description":"\u003c!-- Combined Shopify product HTML for PFPD-2W-T8 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPD-2W-T8\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFPD-2W-T8 | PowerFit 800A Panel Drain, L2 (Line 2) White (regional phase colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPD-2W-T8\" data-color=\"White\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFPD-2W-T8 is an 800A PowerFit single-pole panel drain connector for high-current temporary and permanent power distribution. Its white housing identifies Line 2 (L2), while the m12 threaded post termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eSilver-plated contact ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFPD-2W-T8 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPD-2W-T8 | PowerFit 800A Panel Drain, L2 (Line 2) White (regional phase colour)\",\n  \"description\": \"KUPO PowerFit 800A Panel Drain single-pole connector with white housing for Line 2. M12 threaded post termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFPD-2W-T8\",\n  \"mpn\": \"PFPD-2W-T8\",\n  \"color\": \"White\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"M12 threaded post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Maximum 12-14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 - Line 2 (regional phase colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"White\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPD-2W-T8\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFPD-2W-T8 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2W-T8 is a KUPO PowerFit 800A panel drain connector with a white housing for Line 2 (L2). As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFPD-2W-T8 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2W-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the white housing on PFPD-2W-T8 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe white housing identifies Line 2 (L2). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPD-2W-T8 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2W-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFPD-2W-T8?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFPD-2W-T8 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2W-T8 is a KUPO PowerFit 800A panel drain connector with a white housing for Line 2 (L2). As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFPD-2W-T8 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2W-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the white housing on PFPD-2W-T8 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The white housing identifies Line 2 (L2). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPD-2W-T8 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2W-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFPD-2W-T8?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPD-2W-T8\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPD-2W-T8.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPD-2W-T8 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Panel Mount Receptacle","offer_id":52016196550876,"sku":"PFPD-2W-T8","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPD-2W-T8.jpg?v=1783592611"},{"product_id":"pfpd-2y-t8","title":"PFPD-2Y-T8 - PowerFit 800A Panel Drain, L2 (Line 2) Yellow","description":"\u003c!-- Combined Shopify product HTML for PFPD-2Y-T8 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPD-2Y-T8\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFPD-2Y-T8 | PowerFit 800A Panel Drain, L2 (Line 2) Yellow (regional phase colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPD-2Y-T8\" data-color=\"Yellow\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFPD-2Y-T8 is an 800A PowerFit single-pole panel drain connector for high-current temporary and permanent power distribution. Its yellow housing identifies Line 2 (L2), while the m12 threaded post termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eSilver-plated contact ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFPD-2Y-T8 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPD-2Y-T8 | PowerFit 800A Panel Drain, L2 (Line 2) Yellow (regional phase colour)\",\n  \"description\": \"KUPO PowerFit 800A Panel Drain single-pole connector with yellow housing for Line 2. M12 threaded post termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFPD-2Y-T8\",\n  \"mpn\": \"PFPD-2Y-T8\",\n  \"color\": \"Yellow\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"M12 threaded post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Maximum 12-14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 - Line 2 (regional phase colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Yellow\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPD-2Y-T8\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFPD-2Y-T8 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2Y-T8 is a KUPO PowerFit 800A panel drain connector with a yellow housing for Line 2 (L2). As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFPD-2Y-T8 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2Y-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the yellow housing on PFPD-2Y-T8 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe yellow housing identifies Line 2 (L2). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPD-2Y-T8 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2Y-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFPD-2Y-T8?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFPD-2Y-T8 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2Y-T8 is a KUPO PowerFit 800A panel drain connector with a yellow housing for Line 2 (L2). As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFPD-2Y-T8 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2Y-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the yellow housing on PFPD-2Y-T8 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The yellow housing identifies Line 2 (L2). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPD-2Y-T8 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2Y-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFPD-2Y-T8?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPD-2Y-T8\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPD-2Y-T8.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPD-2Y-T8 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Panel Mount Receptacle","offer_id":52016213033180,"sku":"PFPD-2Y-T8","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPD-2Y-T8.jpg?v=1783592617"},{"product_id":"pfpd-3bl-t8","title":"PFPD-3BL-T8 - PowerFit 800A Panel Drain, L3 (Line 3) Blue","description":"\u003c!-- Combined Shopify product HTML for PFPD-3BL-T8 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPD-3BL-T8\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFPD-3BL-T8 | PowerFit 800A Panel Drain, L3 (Line 3) Blue (IEC \/ regional phase colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPD-3BL-T8\" data-color=\"Blue\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFPD-3BL-T8 is an 800A PowerFit single-pole panel drain connector for high-current temporary and permanent power distribution. Its blue housing identifies Line 3 (L3), while the m12 threaded post termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eSilver-plated contact ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFPD-3BL-T8 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPD-3BL-T8 | PowerFit 800A Panel Drain, L3 (Line 3) Blue (IEC \/ regional phase colour)\",\n  \"description\": \"KUPO PowerFit 800A Panel Drain single-pole connector with blue housing for Line 3. M12 threaded post termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFPD-3BL-T8\",\n  \"mpn\": \"PFPD-3BL-T8\",\n  \"color\": \"Blue\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"M12 threaded post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Maximum 12-14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L3 - Line 3 (IEC \/ regional phase colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Blue\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPD-3BL-T8\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFPD-3BL-T8 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-3BL-T8 is a KUPO PowerFit 800A panel drain connector with a blue housing for Line 3 (L3). As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFPD-3BL-T8 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-3BL-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the blue housing on PFPD-3BL-T8 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe blue housing identifies Line 3 (L3). The source spec sheet associates this colour with IEC \/ regional phase colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPD-3BL-T8 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-3BL-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFPD-3BL-T8?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFPD-3BL-T8 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-3BL-T8 is a KUPO PowerFit 800A panel drain connector with a blue housing for Line 3 (L3). As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFPD-3BL-T8 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-3BL-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the blue housing on PFPD-3BL-T8 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The blue housing identifies Line 3 (L3). The source spec sheet associates this colour with IEC \/ regional phase colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPD-3BL-T8 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-3BL-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFPD-3BL-T8?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPD-3BL-T8\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPD-3BL-T8.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPD-3BL-T8 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Panel Mount Receptacle","offer_id":52016221880540,"sku":"PFPD-3BL-T8","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPD-3BL-T8.jpg?v=1783592622"},{"product_id":"pfpd-3gy-t8","title":"PFPD-3GY-T8 - PowerFit 800A Panel Drain, L3 (Line 3) Gray","description":"\u003c!-- Combined Shopify product HTML for PFPD-3GY-T8 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPD-3GY-T8\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFPD-3GY-T8 | PowerFit 800A Panel Drain, L3 (Line 3) Gray (regional phase colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPD-3GY-T8\" data-color=\"Gray\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFPD-3GY-T8 is an 800A PowerFit single-pole panel drain connector for high-current temporary and permanent power distribution. Its gray housing identifies Line 3 (L3), while the m12 threaded post termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eSilver-plated contact ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFPD-3GY-T8 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPD-3GY-T8 | PowerFit 800A Panel Drain, L3 (Line 3) Gray (regional phase colour)\",\n  \"description\": \"KUPO PowerFit 800A Panel Drain single-pole connector with gray housing for Line 3. M12 threaded post termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFPD-3GY-T8\",\n  \"mpn\": \"PFPD-3GY-T8\",\n  \"color\": \"Gray\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"M12 threaded post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Maximum 12-14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L3 - Line 3 (regional phase colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Gray\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPD-3GY-T8\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFPD-3GY-T8 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-3GY-T8 is a KUPO PowerFit 800A panel drain connector with a gray housing for Line 3 (L3). As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFPD-3GY-T8 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-3GY-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the gray housing on PFPD-3GY-T8 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe gray housing identifies Line 3 (L3). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPD-3GY-T8 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-3GY-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFPD-3GY-T8?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFPD-3GY-T8 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-3GY-T8 is a KUPO PowerFit 800A panel drain connector with a gray housing for Line 3 (L3). As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFPD-3GY-T8 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-3GY-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the gray housing on PFPD-3GY-T8 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The gray housing identifies Line 3 (L3). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPD-3GY-T8 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-3GY-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFPD-3GY-T8?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPD-3GY-T8\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPD-3GY-T8.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPD-3GY-T8 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Panel Mount Receptacle","offer_id":52016230367452,"sku":"PFPD-3GY-T8","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPD-3GY-T8.jpg?v=1783592628"},{"product_id":"pfpd-egn-t8","title":"PFPD-EGN-T8 - PowerFit 800A Panel Drain, Earth - Ground Green","description":"\u003c!-- Combined Shopify product HTML for PFPD-EGN-T8 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPD-EGN-T8\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFPD-EGN-T8 | PowerFit 800A Panel Drain, Earth \/ Ground Green (protective earth) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPD-EGN-T8\" data-color=\"Green\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFPD-EGN-T8 is an 800A PowerFit single-pole panel drain connector for high-current temporary and permanent power distribution. Its green housing identifies Earth \/ Ground, while the m12 threaded post termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eSilver-plated contact ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFPD-EGN-T8 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPD-EGN-T8 | PowerFit 800A Panel Drain, Earth \/ Ground Green (protective earth)\",\n  \"description\": \"KUPO PowerFit 800A Panel Drain single-pole connector with green housing for Earth \/ Ground. M12 threaded post termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFPD-EGN-T8\",\n  \"mpn\": \"PFPD-EGN-T8\",\n  \"color\": \"Green\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"M12 threaded post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Maximum 12-14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Earth - Earth \/ Ground (protective earth)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Green\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPD-EGN-T8\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFPD-EGN-T8 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-EGN-T8 is a KUPO PowerFit 800A panel drain connector with a green housing for Earth \/ Ground. As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFPD-EGN-T8 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-EGN-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the green housing on PFPD-EGN-T8 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe green housing identifies Earth \/ Ground. The source spec sheet associates this colour with protective earth, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPD-EGN-T8 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-EGN-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFPD-EGN-T8?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFPD-EGN-T8 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-EGN-T8 is a KUPO PowerFit 800A panel drain connector with a green housing for Earth \/ Ground. As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFPD-EGN-T8 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-EGN-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the green housing on PFPD-EGN-T8 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The green housing identifies Earth \/ Ground. The source spec sheet associates this colour with protective earth, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPD-EGN-T8 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-EGN-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFPD-EGN-T8?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPD-EGN-T8\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPD-EGN-T8.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPD-EGN-T8 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Panel Mount Receptacle","offer_id":52016238657756,"sku":"PFPD-EGN-T8","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPD-EGN-T8.jpg?v=1783592634"},{"product_id":"pfpd-nbk-t8","title":"PFPD-NBK-T8 - PowerFit 800A Panel Drain, Neutral Black","description":"\u003c!-- Combined Shopify product HTML for PFPD-NBK-T8 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPD-NBK-T8\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFPD-NBK-T8 | PowerFit 800A Panel Drain, Neutral Black (regional neutral colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPD-NBK-T8\" data-color=\"Black\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFPD-NBK-T8 is an 800A PowerFit single-pole panel drain connector for high-current temporary and permanent power distribution. Its black housing identifies Neutral, while the m12 threaded post termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eSilver-plated contact ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFPD-NBK-T8 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPD-NBK-T8 | PowerFit 800A Panel Drain, Neutral Black (regional neutral colour)\",\n  \"description\": \"KUPO PowerFit 800A Panel Drain single-pole connector with black housing for Neutral. M12 threaded post termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFPD-NBK-T8\",\n  \"mpn\": \"PFPD-NBK-T8\",\n  \"color\": \"Black\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"M12 threaded post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Maximum 12-14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Neutral - Neutral (regional neutral colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Black\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPD-NBK-T8\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFPD-NBK-T8 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-NBK-T8 is a KUPO PowerFit 800A panel drain connector with a black housing for Neutral. As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFPD-NBK-T8 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-NBK-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the black housing on PFPD-NBK-T8 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe black housing identifies Neutral. The source spec sheet associates this colour with regional neutral colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPD-NBK-T8 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-NBK-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFPD-NBK-T8?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFPD-NBK-T8 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-NBK-T8 is a KUPO PowerFit 800A panel drain connector with a black housing for Neutral. As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFPD-NBK-T8 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-NBK-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the black housing on PFPD-NBK-T8 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The black housing identifies Neutral. The source spec sheet associates this colour with regional neutral colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPD-NBK-T8 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-NBK-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFPD-NBK-T8?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPD-NBK-T8\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPD-NBK-T8.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPD-NBK-T8 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Panel Mount Receptacle","offer_id":52016255140060,"sku":"PFPD-NBK-T8","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPD-NBK-T8.jpg?v=1783592639"},{"product_id":"pfpd-nbl-t8","title":"PFPD-NBL-T8 - PowerFit 800A Panel Drain, Neutral Blue","description":"\u003c!-- Combined Shopify product HTML for PFPD-NBL-T8 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPD-NBL-T8\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFPD-NBL-T8 | PowerFit 800A Panel Drain, Neutral Blue (IEC) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPD-NBL-T8\" data-color=\"Blue\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFPD-NBL-T8 is an 800A PowerFit single-pole panel drain connector for high-current temporary and permanent power distribution. Its blue housing identifies Neutral, while the m12 threaded post termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eSilver-plated contact ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFPD-NBL-T8 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPD-NBL-T8 | PowerFit 800A Panel Drain, Neutral Blue (IEC)\",\n  \"description\": \"KUPO PowerFit 800A Panel Drain single-pole connector with blue housing for Neutral. M12 threaded post termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFPD-NBL-T8\",\n  \"mpn\": \"PFPD-NBL-T8\",\n  \"color\": \"Blue\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"M12 threaded post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Maximum 12-14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Neutral - Neutral (IEC)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Blue\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPD-NBL-T8\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFPD-NBL-T8 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-NBL-T8 is a KUPO PowerFit 800A panel drain connector with a blue housing for Neutral. As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFPD-NBL-T8 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-NBL-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the blue housing on PFPD-NBL-T8 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe blue housing identifies Neutral. The source spec sheet associates this colour with IEC, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPD-NBL-T8 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-NBL-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFPD-NBL-T8?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFPD-NBL-T8 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-NBL-T8 is a KUPO PowerFit 800A panel drain connector with a blue housing for Neutral. As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFPD-NBL-T8 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-NBL-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the blue housing on PFPD-NBL-T8 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The blue housing identifies Neutral. The source spec sheet associates this colour with IEC, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPD-NBL-T8 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-NBL-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFPD-NBL-T8?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPD-NBL-T8\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPD-NBL-T8.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPD-NBL-T8 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Panel Mount Receptacle","offer_id":52016263725276,"sku":"PFPD-NBL-T8","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPD-NBL-T8.jpg?v=1783592645"},{"product_id":"pfpd-nw-t8","title":"PFPD-NW-T8 - PowerFit 800A Panel Drain, Neutral White","description":"\u003c!-- Combined Shopify product HTML for PFPD-NW-T8 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPD-NW-T8\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFPD-NW-T8 | PowerFit 800A Panel Drain, Neutral White (NEC - North American) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPD-NW-T8\" data-color=\"White\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFPD-NW-T8 is an 800A PowerFit single-pole panel drain connector for high-current temporary and permanent power distribution. Its white housing identifies Neutral, while the m12 threaded post termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eSilver-plated contact ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eErgonomic rubber grip enhances handling comfort and safety\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003cli\u003eO-ring provides an excellent protection against water and dust ingress after mating\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFPD-NW-T8 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPD-NW-T8 | PowerFit 800A Panel Drain, Neutral White (NEC - North American)\",\n  \"description\": \"KUPO PowerFit 800A Panel Drain single-pole connector with white housing for Neutral. M12 threaded post termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFPD-NW-T8\",\n  \"mpn\": \"PFPD-NW-T8\",\n  \"color\": \"White\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"M12 threaded post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Maximum 12-14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Neutral - Neutral (NEC - North American)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"White\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPD-NW-T8\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFPD-NW-T8 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-NW-T8 is a KUPO PowerFit 800A panel drain connector with a white housing for Neutral. As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFPD-NW-T8 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-NW-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the white housing on PFPD-NW-T8 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe white housing identifies Neutral. The source spec sheet associates this colour with NEC - North American, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPD-NW-T8 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-NW-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFPD-NW-T8?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFPD-NW-T8 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-NW-T8 is a KUPO PowerFit 800A panel drain connector with a white housing for Neutral. As a panel-mounted drain-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFPD-NW-T8 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-NW-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the white housing on PFPD-NW-T8 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The white housing identifies Neutral. The source spec sheet associates this colour with NEC - North American, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPD-NW-T8 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-NW-T8 uses m12 threaded post contact termination and a push-and-twist connection interface. The panel-mount body supports protected equipment interfaces and cabinet-mounted distribution points.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFPD-NW-T8?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPD-NW-T8\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPD-NW-T8.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPD-NW-T8 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Panel Mount Receptacle","offer_id":52016272048348,"sku":"PFPD-NW-T8","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPD-NW-T8.jpg?v=1783592651"},{"product_id":"pfps-1bk-t8","title":"PFPS-1BK-T8 - PowerFit 800A Panel Source, L1 (Line 1) Black","description":"\u003c!-- Combined Shopify product HTML for PFPS-1BK-T8 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPS-1BK-T8\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFPS-1BK-T8 | PowerFit 800A Panel Source, L1 (Line 1) Black (NEC - North American) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPS-1BK-T8\" data-color=\"Black\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFPS-1BK-T8 is an 800A PowerFit single-pole panel source connector for high-current temporary and permanent power distribution. Its black housing identifies Line 1 (L1), while the m12 threaded post termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eInnovative key-release pin allows for fast and convenient disconnection\u003c\/li\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFPS-1BK-T8 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPS-1BK-T8 | PowerFit 800A Panel Source, L1 (Line 1) Black (NEC - North American)\",\n  \"description\": \"KUPO PowerFit 800A Panel Source single-pole connector with black housing for Line 1. M12 threaded post termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFPS-1BK-T8\",\n  \"mpn\": \"PFPS-1BK-T8\",\n  \"color\": \"Black\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Source\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist with key release mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"M12 threaded post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Maximum 12-14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L1 - Line 1 (NEC - North American)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Black\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPS-1BK-T8\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFPS-1BK-T8 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-1BK-T8 is a KUPO PowerFit 800A panel source connector with a black housing for Line 1 (L1). As a panel-mounted source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFPS-1BK-T8 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-1BK-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the black housing on PFPS-1BK-T8 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe black housing identifies Line 1 (L1). The source spec sheet associates this colour with NEC - North American, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPS-1BK-T8 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-1BK-T8 uses m12 threaded post contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports controlled release on source-side panel connections.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFPS-1BK-T8?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFPS-1BK-T8 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-1BK-T8 is a KUPO PowerFit 800A panel source connector with a black housing for Line 1 (L1). As a panel-mounted source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFPS-1BK-T8 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-1BK-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the black housing on PFPS-1BK-T8 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The black housing identifies Line 1 (L1). The source spec sheet associates this colour with NEC - North American, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPS-1BK-T8 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-1BK-T8 uses m12 threaded post contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports controlled release on source-side panel connections.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFPS-1BK-T8?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPS-1BK-T8\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPS-1BK-T8.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPS-1BK-T8 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Panel Mount Receptacle","offer_id":52016288694492,"sku":"PFPS-1BK-T8","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPS-1BK-T8.jpg?v=1783592658"},{"product_id":"pfps-1bn-t8","title":"PFPS-1BN-T8 - PowerFit 800A Panel Source, L1 (Line 1) Brown","description":"\u003c!-- Combined Shopify product HTML for PFPS-1BN-T8 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPS-1BN-T8\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFPS-1BN-T8 | PowerFit 800A Panel Source, L1 (Line 1) Brown (IEC) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPS-1BN-T8\" data-color=\"Brown\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFPS-1BN-T8 is an 800A PowerFit single-pole panel source connector for high-current temporary and permanent power distribution. Its brown housing identifies Line 1 (L1), while the m12 threaded post termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eInnovative key-release pin allows for fast and convenient disconnection\u003c\/li\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFPS-1BN-T8 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPS-1BN-T8 | PowerFit 800A Panel Source, L1 (Line 1) Brown (IEC)\",\n  \"description\": \"KUPO PowerFit 800A Panel Source single-pole connector with brown housing for Line 1. M12 threaded post termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFPS-1BN-T8\",\n  \"mpn\": \"PFPS-1BN-T8\",\n  \"color\": \"Brown\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Source\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist with key release mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"M12 threaded post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Maximum 12-14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L1 - Line 1 (IEC)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Brown\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPS-1BN-T8\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFPS-1BN-T8 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-1BN-T8 is a KUPO PowerFit 800A panel source connector with a brown housing for Line 1 (L1). As a panel-mounted source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFPS-1BN-T8 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-1BN-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the brown housing on PFPS-1BN-T8 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe brown housing identifies Line 1 (L1). The source spec sheet associates this colour with IEC, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPS-1BN-T8 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-1BN-T8 uses m12 threaded post contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports controlled release on source-side panel connections.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFPS-1BN-T8?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFPS-1BN-T8 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-1BN-T8 is a KUPO PowerFit 800A panel source connector with a brown housing for Line 1 (L1). As a panel-mounted source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFPS-1BN-T8 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-1BN-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the brown housing on PFPS-1BN-T8 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The brown housing identifies Line 1 (L1). The source spec sheet associates this colour with IEC, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPS-1BN-T8 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-1BN-T8 uses m12 threaded post contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports controlled release on source-side panel connections.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFPS-1BN-T8?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPS-1BN-T8\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPS-1BN-T8.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPS-1BN-T8 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Panel Mount Receptacle","offer_id":52016297050332,"sku":"PFPS-1BN-T8","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPS-1BN-T8.jpg?v=1783592664"},{"product_id":"pfps-1r-t8","title":"PFPS-1R-T8 - PowerFit 800A Panel Source, L1 (Line 1) Red","description":"\u003c!-- Combined Shopify product HTML for PFPS-1R-T8 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPS-1R-T8\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFPS-1R-T8 | PowerFit 800A Panel Source, L1 (Line 1) Red (regional phase colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPS-1R-T8\" data-color=\"Red\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFPS-1R-T8 is an 800A PowerFit single-pole panel source connector for high-current temporary and permanent power distribution. Its red housing identifies Line 1 (L1), while the m12 threaded post termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eInnovative key-release pin allows for fast and convenient disconnection\u003c\/li\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFPS-1R-T8 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPS-1R-T8 | PowerFit 800A Panel Source, L1 (Line 1) Red (regional phase colour)\",\n  \"description\": \"KUPO PowerFit 800A Panel Source single-pole connector with red housing for Line 1. M12 threaded post termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFPS-1R-T8\",\n  \"mpn\": \"PFPS-1R-T8\",\n  \"color\": \"Red\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Source\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist with key release mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"M12 threaded post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Maximum 12-14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L1 - Line 1 (regional phase colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Red\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPS-1R-T8\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFPS-1R-T8 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-1R-T8 is a KUPO PowerFit 800A panel source connector with a red housing for Line 1 (L1). As a panel-mounted source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFPS-1R-T8 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-1R-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the red housing on PFPS-1R-T8 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe red housing identifies Line 1 (L1). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPS-1R-T8 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-1R-T8 uses m12 threaded post contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports controlled release on source-side panel connections.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFPS-1R-T8?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFPS-1R-T8 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-1R-T8 is a KUPO PowerFit 800A panel source connector with a red housing for Line 1 (L1). As a panel-mounted source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFPS-1R-T8 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-1R-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the red housing on PFPS-1R-T8 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The red housing identifies Line 1 (L1). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPS-1R-T8 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-1R-T8 uses m12 threaded post contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports controlled release on source-side panel connections.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFPS-1R-T8?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPS-1R-T8\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPS-1R-T8.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPS-1R-T8 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Panel Mount Receptacle","offer_id":52016305373404,"sku":"PFPS-1R-T8","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPS-1R-T8.jpg?v=1783592669"},{"product_id":"pfps-2bk-t8","title":"PFPS-2BK-T8 - PowerFit 800A Panel Source, L2 (Line 2) Black","description":"\u003c!-- Combined Shopify product HTML for PFPS-2BK-T8 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPS-2BK-T8\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFPS-2BK-T8 | PowerFit 800A Panel Source, L2 (Line 2) Black (regional phase colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPS-2BK-T8\" data-color=\"Black\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFPS-2BK-T8 is an 800A PowerFit single-pole panel source connector for high-current temporary and permanent power distribution. Its black housing identifies Line 2 (L2), while the m12 threaded post termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eInnovative key-release pin allows for fast and convenient disconnection\u003c\/li\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFPS-2BK-T8 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPS-2BK-T8 | PowerFit 800A Panel Source, L2 (Line 2) Black (regional phase colour)\",\n  \"description\": \"KUPO PowerFit 800A Panel Source single-pole connector with black housing for Line 2. M12 threaded post termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFPS-2BK-T8\",\n  \"mpn\": \"PFPS-2BK-T8\",\n  \"color\": \"Black\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Source\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist with key release mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"M12 threaded post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Maximum 12-14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 - Line 2 (regional phase colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Black\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPS-2BK-T8\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFPS-2BK-T8 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-2BK-T8 is a KUPO PowerFit 800A panel source connector with a black housing for Line 2 (L2). As a panel-mounted source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFPS-2BK-T8 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-2BK-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the black housing on PFPS-2BK-T8 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe black housing identifies Line 2 (L2). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPS-2BK-T8 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-2BK-T8 uses m12 threaded post contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports controlled release on source-side panel connections.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFPS-2BK-T8?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFPS-2BK-T8 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2BK-T8 is a KUPO PowerFit 800A panel source connector with a black housing for Line 2 (L2). As a panel-mounted source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFPS-2BK-T8 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2BK-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the black housing on PFPS-2BK-T8 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The black housing identifies Line 2 (L2). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPS-2BK-T8 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2BK-T8 uses m12 threaded post contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports controlled release on source-side panel connections.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFPS-2BK-T8?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPS-2BK-T8\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPS-2BK-T8.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPS-2BK-T8 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Panel Mount Receptacle","offer_id":52016321855708,"sku":"PFPS-2BK-T8","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPS-2BK-T8.jpg?v=1783592675"},{"product_id":"pfps-2r-t8","title":"PFPS-2R-T8 - PowerFit 800A Panel Source, L2 (Line 2) Red","description":"\u003c!-- Combined Shopify product HTML for PFPS-2R-T8 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPS-2R-T8\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFPS-2R-T8 | PowerFit 800A Panel Source, L2 (Line 2) Red (NEC - North American) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPS-2R-T8\" data-color=\"Red\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFPS-2R-T8 is an 800A PowerFit single-pole panel source connector for high-current temporary and permanent power distribution. Its red housing identifies Line 2 (L2), while the m12 threaded post termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eInnovative key-release pin allows for fast and convenient disconnection\u003c\/li\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFPS-2R-T8 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPS-2R-T8 | PowerFit 800A Panel Source, L2 (Line 2) Red (NEC - North American)\",\n  \"description\": \"KUPO PowerFit 800A Panel Source single-pole connector with red housing for Line 2. M12 threaded post termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFPS-2R-T8\",\n  \"mpn\": \"PFPS-2R-T8\",\n  \"color\": \"Red\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Source\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist with key release mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"M12 threaded post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Maximum 12-14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 - Line 2 (NEC - North American)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Red\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPS-2R-T8\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFPS-2R-T8 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-2R-T8 is a KUPO PowerFit 800A panel source connector with a red housing for Line 2 (L2). As a panel-mounted source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFPS-2R-T8 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-2R-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the red housing on PFPS-2R-T8 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe red housing identifies Line 2 (L2). The source spec sheet associates this colour with NEC - North American, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPS-2R-T8 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-2R-T8 uses m12 threaded post contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports controlled release on source-side panel connections.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFPS-2R-T8?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFPS-2R-T8 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2R-T8 is a KUPO PowerFit 800A panel source connector with a red housing for Line 2 (L2). As a panel-mounted source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFPS-2R-T8 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2R-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the red housing on PFPS-2R-T8 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The red housing identifies Line 2 (L2). The source spec sheet associates this colour with NEC - North American, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPS-2R-T8 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2R-T8 uses m12 threaded post contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports controlled release on source-side panel connections.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFPS-2R-T8?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPS-2R-T8\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPS-2R-T8.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPS-2R-T8 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Panel Mount Receptacle","offer_id":52016330178780,"sku":"PFPS-2R-T8","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPS-2R-T8.jpg?v=1783592680"},{"product_id":"pfps-2w-t8","title":"PFPS-2W-T8 - PowerFit 800A Panel Source, L2 (Line 2) White","description":"\u003c!-- Combined Shopify product HTML for PFPS-2W-T8 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPS-2W-T8\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFPS-2W-T8 | PowerFit 800A Panel Source, L2 (Line 2) White (regional phase colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPS-2W-T8\" data-color=\"White\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFPS-2W-T8 is an 800A PowerFit single-pole panel source connector for high-current temporary and permanent power distribution. Its white housing identifies Line 2 (L2), while the m12 threaded post termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eInnovative key-release pin allows for fast and convenient disconnection\u003c\/li\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFPS-2W-T8 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPS-2W-T8 | PowerFit 800A Panel Source, L2 (Line 2) White (regional phase colour)\",\n  \"description\": \"KUPO PowerFit 800A Panel Source single-pole connector with white housing for Line 2. M12 threaded post termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFPS-2W-T8\",\n  \"mpn\": \"PFPS-2W-T8\",\n  \"color\": \"White\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Source\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist with key release mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"M12 threaded post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Maximum 12-14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 - Line 2 (regional phase colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"White\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPS-2W-T8\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFPS-2W-T8 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-2W-T8 is a KUPO PowerFit 800A panel source connector with a white housing for Line 2 (L2). As a panel-mounted source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFPS-2W-T8 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-2W-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the white housing on PFPS-2W-T8 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe white housing identifies Line 2 (L2). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPS-2W-T8 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-2W-T8 uses m12 threaded post contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports controlled release on source-side panel connections.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFPS-2W-T8?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFPS-2W-T8 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2W-T8 is a KUPO PowerFit 800A panel source connector with a white housing for Line 2 (L2). As a panel-mounted source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFPS-2W-T8 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2W-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the white housing on PFPS-2W-T8 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The white housing identifies Line 2 (L2). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPS-2W-T8 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2W-T8 uses m12 threaded post contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports controlled release on source-side panel connections.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFPS-2W-T8?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPS-2W-T8\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPS-2W-T8.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPS-2W-T8 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Panel Mount Receptacle","offer_id":52016330309852,"sku":"PFPS-2W-T8","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPS-2W-T8.jpg?v=1783592686"},{"product_id":"pfps-2y-t8","title":"PFPS-2Y-T8 - PowerFit 800A Panel Source, L2 (Line 2) Yellow","description":"\u003c!-- Combined Shopify product HTML for PFPS-2Y-T8 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPS-2Y-T8\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFPS-2Y-T8 | PowerFit 800A Panel Source, L2 (Line 2) Yellow (regional phase colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPS-2Y-T8\" data-color=\"Yellow\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFPS-2Y-T8 is an 800A PowerFit single-pole panel source connector for high-current temporary and permanent power distribution. Its yellow housing identifies Line 2 (L2), while the m12 threaded post termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eInnovative key-release pin allows for fast and convenient disconnection\u003c\/li\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFPS-2Y-T8 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPS-2Y-T8 | PowerFit 800A Panel Source, L2 (Line 2) Yellow (regional phase colour)\",\n  \"description\": \"KUPO PowerFit 800A Panel Source single-pole connector with yellow housing for Line 2. M12 threaded post termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFPS-2Y-T8\",\n  \"mpn\": \"PFPS-2Y-T8\",\n  \"color\": \"Yellow\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Source\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist with key release mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"M12 threaded post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Maximum 12-14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 - Line 2 (regional phase colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Yellow\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPS-2Y-T8\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFPS-2Y-T8 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-2Y-T8 is a KUPO PowerFit 800A panel source connector with a yellow housing for Line 2 (L2). As a panel-mounted source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFPS-2Y-T8 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-2Y-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the yellow housing on PFPS-2Y-T8 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe yellow housing identifies Line 2 (L2). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPS-2Y-T8 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-2Y-T8 uses m12 threaded post contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports controlled release on source-side panel connections.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFPS-2Y-T8?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFPS-2Y-T8 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2Y-T8 is a KUPO PowerFit 800A panel source connector with a yellow housing for Line 2 (L2). As a panel-mounted source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFPS-2Y-T8 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2Y-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the yellow housing on PFPS-2Y-T8 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The yellow housing identifies Line 2 (L2). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPS-2Y-T8 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-2Y-T8 uses m12 threaded post contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports controlled release on source-side panel connections.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFPS-2Y-T8?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPS-2Y-T8\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPS-2Y-T8.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPS-2Y-T8 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Panel Mount Receptacle","offer_id":52016338698460,"sku":"PFPS-2Y-T8","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPS-2Y-T8.jpg?v=1783592692"},{"product_id":"pfps-3bl-t8","title":"PFPS-3BL-T8 - PowerFit 800A Panel Source, L3 (Line 3) Blue","description":"\u003c!-- Combined Shopify product HTML for PFPS-3BL-T8 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPS-3BL-T8\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFPS-3BL-T8 | PowerFit 800A Panel Source, L3 (Line 3) Blue (IEC \/ regional phase colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPS-3BL-T8\" data-color=\"Blue\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFPS-3BL-T8 is an 800A PowerFit single-pole panel source connector for high-current temporary and permanent power distribution. Its blue housing identifies Line 3 (L3), while the m12 threaded post termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eInnovative key-release pin allows for fast and convenient disconnection\u003c\/li\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFPS-3BL-T8 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPS-3BL-T8 | PowerFit 800A Panel Source, L3 (Line 3) Blue (IEC \/ regional phase colour)\",\n  \"description\": \"KUPO PowerFit 800A Panel Source single-pole connector with blue housing for Line 3. M12 threaded post termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFPS-3BL-T8\",\n  \"mpn\": \"PFPS-3BL-T8\",\n  \"color\": \"Blue\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Source\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist with key release mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"M12 threaded post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Maximum 12-14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L3 - Line 3 (IEC \/ regional phase colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Blue\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPS-3BL-T8\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFPS-3BL-T8 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-3BL-T8 is a KUPO PowerFit 800A panel source connector with a blue housing for Line 3 (L3). As a panel-mounted source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFPS-3BL-T8 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-3BL-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the blue housing on PFPS-3BL-T8 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe blue housing identifies Line 3 (L3). The source spec sheet associates this colour with IEC \/ regional phase colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPS-3BL-T8 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-3BL-T8 uses m12 threaded post contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports controlled release on source-side panel connections.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFPS-3BL-T8?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFPS-3BL-T8 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-3BL-T8 is a KUPO PowerFit 800A panel source connector with a blue housing for Line 3 (L3). As a panel-mounted source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFPS-3BL-T8 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-3BL-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the blue housing on PFPS-3BL-T8 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The blue housing identifies Line 3 (L3). The source spec sheet associates this colour with IEC \/ regional phase colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPS-3BL-T8 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-3BL-T8 uses m12 threaded post contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports controlled release on source-side panel connections.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFPS-3BL-T8?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPS-3BL-T8\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPS-3BL-T8.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPS-3BL-T8 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Panel Mount Receptacle","offer_id":52016347152604,"sku":"PFPS-3BL-T8","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPS-3BL-T8.jpg?v=1783592698"},{"product_id":"pfps-3gy-t8","title":"PFPS-3GY-T8 - PowerFit 800A Panel Source, L3 (Line 3) Gray","description":"\u003c!-- Combined Shopify product HTML for PFPS-3GY-T8 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPS-3GY-T8\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFPS-3GY-T8 | PowerFit 800A Panel Source, L3 (Line 3) Gray (regional phase colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPS-3GY-T8\" data-color=\"Gray\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFPS-3GY-T8 is an 800A PowerFit single-pole panel source connector for high-current temporary and permanent power distribution. Its gray housing identifies Line 3 (L3), while the m12 threaded post termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eInnovative key-release pin allows for fast and convenient disconnection\u003c\/li\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFPS-3GY-T8 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPS-3GY-T8 | PowerFit 800A Panel Source, L3 (Line 3) Gray (regional phase colour)\",\n  \"description\": \"KUPO PowerFit 800A Panel Source single-pole connector with gray housing for Line 3. M12 threaded post termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFPS-3GY-T8\",\n  \"mpn\": \"PFPS-3GY-T8\",\n  \"color\": \"Gray\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Source\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist with key release mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"M12 threaded post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Maximum 12-14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L3 - Line 3 (regional phase colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Gray\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPS-3GY-T8\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFPS-3GY-T8 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-3GY-T8 is a KUPO PowerFit 800A panel source connector with a gray housing for Line 3 (L3). As a panel-mounted source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFPS-3GY-T8 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-3GY-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the gray housing on PFPS-3GY-T8 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe gray housing identifies Line 3 (L3). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPS-3GY-T8 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-3GY-T8 uses m12 threaded post contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports controlled release on source-side panel connections.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFPS-3GY-T8?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFPS-3GY-T8 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-3GY-T8 is a KUPO PowerFit 800A panel source connector with a gray housing for Line 3 (L3). As a panel-mounted source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFPS-3GY-T8 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-3GY-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the gray housing on PFPS-3GY-T8 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The gray housing identifies Line 3 (L3). The source spec sheet associates this colour with regional phase colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPS-3GY-T8 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-3GY-T8 uses m12 threaded post contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports controlled release on source-side panel connections.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFPS-3GY-T8?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPS-3GY-T8\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPS-3GY-T8.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPS-3GY-T8 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Panel Mount Receptacle","offer_id":52016355803356,"sku":"PFPS-3GY-T8","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPS-3GY-T8.jpg?v=1783592703"},{"product_id":"pfps-egn-t8","title":"PFPS-EGN-T8 - PowerFit 800A Panel Source, Earth - Ground Green","description":"\u003c!-- Combined Shopify product HTML for PFPS-EGN-T8 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPS-EGN-T8\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFPS-EGN-T8 | PowerFit 800A Panel Source, Earth \/ Ground Green (protective earth) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPS-EGN-T8\" data-color=\"Green\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFPS-EGN-T8 is an 800A PowerFit single-pole panel source connector for high-current temporary and permanent power distribution. Its green housing identifies Earth \/ Ground, while the m12 threaded post termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eInnovative key-release pin allows for fast and convenient disconnection\u003c\/li\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFPS-EGN-T8 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPS-EGN-T8 | PowerFit 800A Panel Source, Earth \/ Ground Green (protective earth)\",\n  \"description\": \"KUPO PowerFit 800A Panel Source single-pole connector with green housing for Earth \/ Ground. M12 threaded post termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFPS-EGN-T8\",\n  \"mpn\": \"PFPS-EGN-T8\",\n  \"color\": \"Green\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Source\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist with key release mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"M12 threaded post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Maximum 12-14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Earth - Earth \/ Ground (protective earth)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Green\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPS-EGN-T8\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFPS-EGN-T8 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-EGN-T8 is a KUPO PowerFit 800A panel source connector with a green housing for Earth \/ Ground. As a panel-mounted source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFPS-EGN-T8 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-EGN-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the green housing on PFPS-EGN-T8 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe green housing identifies Earth \/ Ground. The source spec sheet associates this colour with protective earth, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPS-EGN-T8 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-EGN-T8 uses m12 threaded post contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports controlled release on source-side panel connections.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFPS-EGN-T8?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFPS-EGN-T8 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-EGN-T8 is a KUPO PowerFit 800A panel source connector with a green housing for Earth \/ Ground. As a panel-mounted source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFPS-EGN-T8 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-EGN-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the green housing on PFPS-EGN-T8 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The green housing identifies Earth \/ Ground. The source spec sheet associates this colour with protective earth, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPS-EGN-T8 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-EGN-T8 uses m12 threaded post contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports controlled release on source-side panel connections.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFPS-EGN-T8?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPS-EGN-T8\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPS-EGN-T8.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPS-EGN-T8 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Panel Mount Receptacle","offer_id":52016373039324,"sku":"PFPS-EGN-T8","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPS-EGN-T8.jpg?v=1783592710"},{"product_id":"pfps-nbk-t8","title":"PFPS-NBK-T8 - PowerFit 800A Panel Source, Neutral Black","description":"\u003c!-- Combined Shopify product HTML for PFPS-NBK-T8 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPS-NBK-T8\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PFPS-NBK-T8 | PowerFit 800A Panel Source, Neutral Black (regional neutral colour) --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPS-NBK-T8\" data-color=\"Black\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFPS-NBK-T8 is an 800A PowerFit single-pole panel source connector for high-current temporary and permanent power distribution. Its black housing identifies Neutral, while the m12 threaded post termination supports heavy cable or busbar-style integration depending on the connector format. Silver-plated copper contacts, high-impact thermoplastic insulation, IP67 protection when mated, and UL94-V0 body material make the connector suitable for demanding event, industrial, energy storage, and generator distribution environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eInnovative key-release pin allows for fast and convenient disconnection\u003c\/li\u003e\n\u003cli\u003eCopper contact with silver plating ensures excellent conductivity\u003c\/li\u003e\n\u003cli\u003eDurable thermoplastic body offers superior impact resistance and electrical insulation\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTÜV certification listed on source spec sheet\u003c\/li\u003e\n\u003cli\u003eCE marking for European market compliance\u003c\/li\u003e\n\u003cli\u003eRoHS compliance restricts hazardous substances\u003c\/li\u003e\n\u003cli\u003eREACH compliance supports material traceability\u003c\/li\u003e\n\u003cli\u003eUL94-V0 flame rating for the connector body material\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFPS-NBK-T8 supports high-current power distribution where single-pole connectors must remain easy to identify, quick to mate, and protected against demanding site conditions. Typical uses include event power distribution, generator rental, industrial switchgear, battery energy storage systems, and other professional power systems that require durable 800A connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThis connector belongs to the KUPO PowerFit single-pole connector family. The push-and-twist interface, colour-coded housing, and listed electrical ratings make it suitable for PowerFit system layouts where mating connector type, conductor role, and project wiring convention are confirmed before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPS-NBK-T8 | PowerFit 800A Panel Source, Neutral Black (regional neutral colour)\",\n  \"description\": \"KUPO PowerFit 800A Panel Source single-pole connector with black housing for Neutral. M12 threaded post termination, IP67 rating while mated, silver-plated copper contacts, 1000V AC\/DC Maximum, and TUV, CE, RoHS, and REACH compliance.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFPS-NBK-T8\",\n  \"mpn\": \"PFPS-NBK-T8\",\n  \"color\": \"Black\",\n  \"material\": \"Non-conductive high impact-resistant thermoplastic; Copper (silver-plated) contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"800A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"16 kA \/1 s (RMS); 35.5 kA (Peak)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Source\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist with key release mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Type\",\n      \"value\": \"M12 threaded post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (silver-plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"Not applicable \/ source value not listed\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Nut Torque\",\n      \"value\": \"Maximum 12-14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 rating while mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0 (body material rating)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"-25 to 125 degrees C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS and REACH compliant\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Neutral - Neutral (regional neutral colour)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Black\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPS-NBK-T8\" data-category=\"PowerFit 800A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is the PFPS-NBK-T8 and what role does it play in a PowerFit system?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-NBK-T8 is a KUPO PowerFit 800A panel source connector with a black housing for Neutral. As a panel-mounted source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current and voltage can PFPS-NBK-T8 handle?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-NBK-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the black housing on PFPS-NBK-T8 identify?\u003c\/h3\u003e\n    \u003cp\u003eThe black housing identifies Neutral. The source spec sheet associates this colour with regional neutral colour, so the colour should be checked against the project's wiring convention before installation.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPS-NBK-T8 terminated and operated?\u003c\/h3\u003e\n    \u003cp\u003ePFPS-NBK-T8 uses m12 threaded post contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports controlled release on source-side panel connections.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications and environmental protections are listed for PFPS-NBK-T8?\u003c\/h3\u003e\n    \u003cp\u003eThe spec sheet lists TÜV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the PFPS-NBK-T8 and what role does it play in a PowerFit system?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-NBK-T8 is a KUPO PowerFit 800A panel source connector with a black housing for Neutral. As a panel-mounted source-side connector, it forms part of a single-pole high-current connection and is designed for IP67 protection when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How much current and voltage can PFPS-NBK-T8 handle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-NBK-T8 is rated for 800A Maximum. The voltage rating is 1000V AC\/DC Maximum, with a 4500V AC test voltage, insulation resistance greater than 5000 megohms at 500V AC, and contact resistance of 0.1 milliohms.\"}}, {\"@type\": \"Question\", \"name\": \"What does the black housing on PFPS-NBK-T8 identify?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The black housing identifies Neutral. The source spec sheet associates this colour with regional neutral colour, so the colour should be checked against the project's wiring convention before installation.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPS-NBK-T8 terminated and operated?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPS-NBK-T8 uses m12 threaded post contact termination and a push-and-twist with key release mechanism connection interface. The key-release pin supports controlled release on source-side panel connections.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications and environmental protections are listed for PFPS-NBK-T8?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The spec sheet lists TUV, CE, RoHS, and REACH compliance, IP67 rating while mated, UL94-V0 flammability rating for the body material, and a working temperature range of -25 to 125 degrees Celsius.\"}}]}\u003c\/script\u003e\n\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPS-NBK-T8\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPS-NBK-T8.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPS-NBK-T8 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 800A \/ Panel Mount Receptacle","offer_id":52016389554396,"sku":"PFPS-NBK-T8","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPS-NBK-T8.jpg?v=1783592716"}],"url":"https:\/\/kupopower.com\/collections\/powerfit-800a.oembed?page=2","provider":"KUPO Power","version":"1.0","type":"link"}