{"product_id":"pfld-nbk","title":"PFLD-NBK-S120M40A - PowerFit 400A złącze nakablowe biorcze (Drain), czarne (N)","description":"\u003c!-- Combined Shopify product HTML for PFLD-NBK-S120M40A --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLD-NBK-S120M40A\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eOpis produktu\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Line Drain Connector (Black) | PFLD-NBK-S120M40A | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLD-NBK-S120M40A\" data-color=\"Black\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eW symetrycznych układach trójfazowych i w rozdziale jednofazowym przewód neutralny zamyka obwód i przewodzi prąd powrotny przy niesymetrii, zapewniając stabilność systemu i koordynację zabezpieczeń. PFLD-NBK-S120M40A zaprojektowano do pracy jako przewód neutralny przy pełnym obciążeniu 400 A, z niezawodnością wymaganą w sieciach przemysłowych i energetycznych. Czarna izolacja jest zgodna z normami australijskimi (AS\/NZS 3000) i dawnym brytyjskim kodem barw (BS 3371), co czyni to złącze standardowym wyborem dla instalacji w Australii, Nowej Zelandii i starszej infrastrukturze brytyjskiej. Przy napięciu znamionowym 1000 V AC lub DC i obciążalności 400 A to złącze nakablowe biorcze ze stykiem żeńskim zapewnia niskoimpedancyjną, odporną na awarie ścieżkę neutralną, której wymagają nowoczesne systemy zasilania.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eNajważniejsze cechy\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrąd znamionowy:\u003c\/strong\u003e 400 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNapięcie znamionowe:\u003c\/strong\u003e maksymalnie 1000 V AC\/DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNapięcie probiercze:\u003c\/strong\u003e próba 4500 V (trzy sekundy)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWytrzymałość zwarciowa:\u003c\/strong\u003e 16 kA przez 1 s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRezystancja izolacji:\u003c\/strong\u003e powyżej 5000 MΩ przy 500 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRezystancja styku:\u003c\/strong\u003e nominalnie 0,1 mΩ (przy prądzie znamionowym)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZakres temperatury pracy:\u003c\/strong\u003e od -25 do 125 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiczba cykli łączeniowych:\u003c\/strong\u003e minimum 500 cykli\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStopień ochrony:\u003c\/strong\u003e IP67 po połączeniu\u003c\/li\u003e\n\u003cli\u003eNie do rozłączania pod obciążeniem: łączyć i rozłączać wyłącznie przy odłączonym zasilaniu obwodu\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertyfikaty i normy\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTÜV:\u003c\/strong\u003e Certyfikat według IEC 61984 (ID 1111322264)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOznakowanie CE:\u003c\/strong\u003e Zgodność z wymaganiami dyrektyw Unii Europejskiej\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDyrektywa RoHS:\u003c\/strong\u003e Zgodność z 2011\/65\/UE (ograniczenie stosowania substancji niebezpiecznych)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRozporządzenie REACH:\u003c\/strong\u003e Rejestracja i zgodność z WE 1907\/2006 (rejestracja, ocena, udzielanie zezwoleń i stosowane ograniczenia w zakresie chemikaliów)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL94-V0:\u003c\/strong\u003e Obudowa spełnia najwyższą klasę odporności na płomień\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAS\/NZS 3000:\u003c\/strong\u003e Zgodność z australijską i nowozelandzką normą bezpieczeństwa elektrycznego\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBS 3371:\u003c\/strong\u003e Zgodność z historycznym brytyjskim kodem barw dla starszej infrastruktury\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eZastosowania\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003eTrójfazowy przemysłowy rozdział energii w Australii i Nowej Zelandii wymagający obciążalności przewodu neutralnego\u003c\/li\u003e\n\u003cli\u003eAparatura rozdzielcza i rozdzielnice energetyczne, w których niezbędny jest powrót prądu przy niesymetrii obciążenia\u003c\/li\u003e\n\u003cli\u003eModernizacja i serwis starszej brytyjskiej infrastruktury elektrycznej, w której nadal obowiązuje konwencja barw BS 3371\u003c\/li\u003e\n\u003cli\u003eModułowe systemy rozdziału energii dla rynków regionalnych wymagających zgodności z AS\/NZS 3000\u003c\/li\u003e\n\u003cli\u003eCiężkie maszyny przemysłowe i systemy sterowania procesami z obciążalnością przewodu neutralnego 400 A\u003c\/li\u003e\n\u003cli\u003eInstalacje energii odnawialnej (fotowoltaika, energetyka wiatrowa) w regionie Australii i Nowej Zelandii, w których ciągłość przewodu neutralnego jest kluczowa dla pracy falowników\u003c\/li\u003e\n\u003cli\u003eCentra danych i obiekty telekomunikacyjne wymagające ścieżek neutralnych dla dużych prądów\u003c\/li\u003e\n\u003cli\u003ePlatformy morskie i offshore działające według standardów IMCA (International Maritime Contractors Association)\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eKompatybilność\u003c\/h3\u003e\n    \u003cp\u003eZłącze nakablowe biorcze (Drain) PowerFit 400A ze stykiem żeńskim jest w pełni kompatybilne ze stykami męskimi głównych rodzin złączy jednobiegunowych stosowanych w Australii, Nowej Zelandii i Wielkiej Brytanii. Blokada bagnetowa (wciśnij i przekręć, nie typu CAM) zapewnia intuicyjne, niezawodne łączenie ze stałym stykiem elektrycznym i mechanicznym.\u003c\/p\u003e\n\u003cp\u003eZakres dławnicy kablowej: gwint M40 x 1,5; przewód o średnicy Ø 14 do 33 mm z wkładką CG-M4015-32 lub Ø 12 do 18 mm z wkładką CG-M4015. Z posrebrzaną mosiężną tuleją redukcyjną R120 przyjmuje żyły o średnicy do 16,50 milimetra.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003eOznaczenie barwne faz i przewodów\u003c\/h3\u003e\n    \u003cimg src=\"https:\/\/pub-575371843efc4b84863e8e2a0298e68b.r2.dev\/Color-meaning\/Color-code-connectors.webp\" alt=\"Schemat oznaczeń barwnych złączy\" style=\"max-width: 100%; margin: 1rem 0;\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLD-NBK-S120M40A | PowerFit 400A, złącze nakablowe biorcze (Drain), przewód neutralny (N), czarne (Australia \/ Wielka Brytania, stara norma)\",\n  \"description\": \"Złącze jednobiegunowe KUPO PowerFit 400A, nakablowe biorcze (Drain), z czarną obudową do systemów rozdziału energii w Australii i Wielkiej Brytanii (stara norma). Styk żeński, dławnica kablowa M40 z tuleją uszczelniającą, stopień ochrony IP67 po połączeniu, styki mosiężne posrebrzane, 400 A, maksymalnie 1000 V AC\/DC, z certyfikatem TÜV.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Złącza elektryczne \u003e Złącza jednobiegunowe \u003e PowerFit\",\n  \"sku\": \"PFLD-NBK-S120M40A\",\n  \"mpn\": \"PFLD-NBK-S120M40A\",\n  \"color\": \"Czarny\",\n  \"material\": \"Nieprzewodząca obudowa z tworzywa termoplastycznego; styki mosiężne posrebrzane\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Napięcie znamionowe\",\n      \"value\": \"Maks. 1000 V AC\/DC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Prąd znamionowy\",\n      \"value\": \"Maks. 400 A\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Napięcie probiercze\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Prąd znamionowy krótkotrwały wytrzymywany (Icw)\",\n      \"value\": \"16 kA przez 1 s (prąd krótkotrwały wytrzymywany)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Rezystancja izolacji\",\n      \"value\": \"Powyżej 5000 MΩ przy 500 V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Rezystancja styku\",\n      \"value\": \"0,1 mΩ\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Typ złącza\",\n      \"value\": \"Złącze nakablowe biorcze (Drain), styk żeński\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mechanizm połączenia\",\n      \"value\": \"Blokada bagnetowa (wciśnij i przekręć)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Materiał styków\",\n      \"value\": \"Mosiądz (posrebrzany)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Materiał obudowy\",\n      \"value\": \"Nieprzewodzące tworzywo termoplastyczne o wysokiej udarności (samogasnące, UL94-V0)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Materiał uszczelki O-ring\",\n      \"value\": \"Silikon\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Dławnica kablowa\",\n      \"value\": \"M40 x 1,5; wkładka dławnicy CG-M4015-32 do przewodu o średnicy Ø 14 do 33 mm lub CG-M4015 do przewodu o średnicy Ø 12 do 18 mm\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Moment dokręcania śrub dociskowych\",\n      \"value\": \"min. 10,5 N·m\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Stopień ochrony IP\",\n      \"value\": \"IP67 po połączeniu\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Klasa palności\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Zakres temperatury pracy\",\n      \"value\": \"-25 °C do 125 °C\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Liczba cykli łączeniowych\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Numer certyfikatu TÜV (ID)\",\n      \"value\": \"1111322264\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certyfikaty\",\n      \"value\": \"TÜV Rheinland (IEC 61984), CB, CE, UKCA, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Oznaczenie faz\",\n      \"value\": \"Przewód neutralny (N) (Australia \/ Wielka Brytania, stara norma)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Kolor obudowy\",\n      \"value\": \"Czarny\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLD-NBK-S120M40A\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eNajczęściej zadawane pytania\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eKomu jest potrzebne złącze PFLD-NBK-S120M40A i jaki problem rozwiązuje?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-NBK-S120M40A to złącze nakablowe biorcze (Drain) KUPO PowerFit 400A z czarną obudową, przeznaczone dla przewodu neutralnego (N) według konwencji australijskiej i starej brytyjskiej (sprzed 2004 r.). Jako strona biorcza połączenia kablowego przyjmuje styk dawczy (Source) i po połączeniu tworzy szczelne złącze o stopniu ochrony IP67. Czarna obudowa umożliwia natychmiastową wizualną identyfikację przewodu N na całej długości tras kablowych.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eJaki prąd może bezpiecznie przewodzić PFLD-NBK-S120M40A w pracy ciągłej?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-NBK-S120M40A ma prąd znamionowy ciągły 400 A przy przewodzie 120 mm². Maksymalne napięcie znamionowe wynosi 1000 V AC lub DC. Rezystancja izolacji przekracza 5000 MΩ przy 500 V AC, a napięcie probiercze 4500 V AC zapewnia duży margines bezpieczeństwa. Prąd znamionowy krótkotrwały wytrzymywany wynosi 16 kA przez 1 s.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eCo czarna obudowa PFLD-NBK-S120M40A mówi o jego przeznaczeniu dla przewodu neutralnego?\u003c\/h3\u003e\n    \u003cp\u003eCzarny jako przewód neutralny wynika z australijskiej konwencji instalacyjnej i dawnego brytyjskiego kodu barw (sprzed harmonizacji w 2004 r.). W Australii standardowy zestaw barw obejmuje czarny dla przewodu neutralnego obok czerwonego (L1), białego (L2), niebieskiego (L3) i zielonego (przewód ochronny). W złączu nakablowym biorczym (Drain) czarna obudowa jest widoczna na całej długości korpusu 190 mm, co ułatwia identyfikację N nawet w ciasno związanych wiązkach kabli. Kolor ma także ergonomiczny gumowy uchwyt, dzięki czemu technicy rozpoznają przewód, trzymając złącze w dłoni. Pomylenie czarnego przewodu neutralnego (Australia) z czarnym przewodem fazowym (L1 w NEC lub L2 w IEC) może spowodować niebezpieczne zwarcie między przewodem neutralnym a fazą. Złącza z kodowaniem faz temu zapobiegają.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eJakie certyfikaty do zastosowań profesjonalnych ma PFLD-NBK-S120M40A?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-NBK-S120M40A ma certyfikat TÜV Rheinland zgodnie z IEC 61984 (ID 1111322264) w kategoriach badania typu (Type Approval), bezpieczeństwa (Safety) i regularnego nadzoru produkcji (Regular Production Surveillance). Posiada także certyfikaty CB i UKCA, oznakowanie CE oraz zgodność z RoHS (ograniczenie stosowania substancji niebezpiecznych) i REACH. Materiał obudowy uzyskał klasę palności UL94-V0, najwyższą w serii pionowej próby palności UL94 (V), co oznacza, że materiał samoczynnie gaśnie w ciągu 10 sekund bez płonących kropli. Silikonowa uszczelka O-ring zapewnia stopień ochrony IP67 po połączeniu, co oznacza pełną ochronę przed wnikaniem pyłu i czasowym zanurzeniem w wodzie do 1 m na 30 minut.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eCzy PFLD-NBK-S120M40A można włączyć do istniejącego systemu rozdziału energii?\u003c\/h3\u003e\n    \u003cp\u003eZłącza PowerFit zaprojektowano tak, aby były kompatybilne ze złączami jednobiegunowymi wiodących producentów. Kołek zwalniający umożliwia rozłączenie bez narzędzi podczas demontażu, blokada bagnetowa (wciśnij i przekręć) zatrzaskuje się w kilka sekund, a ergonomiczny gumowy uchwyt zmniejsza zmęczenie dłoni podczas długich montaży obejmujących dziesiątki połączeń. W obwodach N stosujących konwencję barw australijską i starą brytyjską (sprzed 2004 r.) czarne złącze PFLD-NBK-S120M40A zapewnia spójną identyfikację przewodów przy łączeniu złączy PowerFit z posiadanym sprzętem.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eJakie narzędzia i czynności są potrzebne do zarobienia PFLD-NBK-S120M40A?\u003c\/h3\u003e\n    \u003cp\u003eAby zmontować PFLD-NBK-S120M40A, zdejmij dławnicę kablową M40 i wyjmij styk. Włóż styk do izolatora i wyrównaj otwór na zawleczkę. Zdejmij izolację zewnętrzną przewodu na długości około 33 mm, a następnie nasuń tuleję redukcyjną R120 (mosiężną, posrebrzaną, dla żył o średnicy do 16,50 mm) na odsłoniętą żyłę. Wbij zawleczkę od strony fazowanej, aby prawidłowo ją osadzić. Wsuń przewód z tuleją redukcyjną do styku, a następnie dokręć obie śruby dociskowe kluczem imbusowym 5 mm z momentem co najmniej 10,5 N·m. Na koniec nakręć z powrotem dławnicę kablową. Dławnica M40 przyjmuje przewody o średnicy Ø 14 do 33 mm z wkładką CG-M4015-32 lub Ø 12 do 18 mm z wkładką CG-M4015. Przy całkowitej długości 190 mm i średnicy korpusu 32,5 mm złącze nakablowe biorcze (Drain) jest najdłuższym złączem w rodzinie PowerFit, co zapewnia dużo miejsca na prowadzenie kabla i pewny uchwyt.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Komu jest potrzebne złącze PFLD-NBK-S120M40A i jaki problem rozwiązuje?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-NBK-S120M40A to złącze nakablowe biorcze (Drain) KUPO PowerFit 400A z czarną obudową, przeznaczone dla przewodu neutralnego (N) według konwencji australijskiej i starej brytyjskiej (sprzed 2004 r.). Jako strona biorcza połączenia kablowego przyjmuje styk dawczy (Source) i po połączeniu tworzy szczelne złącze o stopniu ochrony IP67. Czarna obudowa umożliwia natychmiastową wizualną identyfikację przewodu N na całej długości tras kablowych.\"}}, {\"@type\": \"Question\", \"name\": \"Jaki prąd może bezpiecznie przewodzić PFLD-NBK-S120M40A w pracy ciągłej?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-NBK-S120M40A ma prąd znamionowy ciągły 400 A przy przewodzie 120 mm². Maksymalne napięcie znamionowe wynosi 1000 V AC lub DC. Rezystancja izolacji przekracza 5000 MΩ przy 500 V AC, a napięcie probiercze 4500 V AC zapewnia duży margines bezpieczeństwa. Prąd znamionowy krótkotrwały wytrzymywany wynosi 16 kA przez 1 s.\"}}, {\"@type\": \"Question\", \"name\": \"Co czarna obudowa PFLD-NBK-S120M40A mówi o jego przeznaczeniu dla przewodu neutralnego?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Czarny jako przewód neutralny wynika z australijskiej konwencji instalacyjnej i dawnego brytyjskiego kodu barw (sprzed harmonizacji w 2004 r.). W Australii standardowy zestaw barw obejmuje czarny dla przewodu neutralnego obok czerwonego (L1), białego (L2), niebieskiego (L3) i zielonego (przewód ochronny). W złączu nakablowym biorczym (Drain) czarna obudowa jest widoczna na całej długości korpusu 190 mm, co ułatwia identyfikację N nawet w ciasno związanych wiązkach kabli. Kolor ma także ergonomiczny gumowy uchwyt, dzięki czemu technicy rozpoznają przewód, trzymając złącze w dłoni. Pomylenie czarnego przewodu neutralnego (Australia) z czarnym przewodem fazowym (L1 w NEC lub L2 w IEC) może spowodować niebezpieczne zwarcie między przewodem neutralnym a fazą. Złącza z kodowaniem faz temu zapobiegają.\"}}, {\"@type\": \"Question\", \"name\": \"Jakie certyfikaty do zastosowań profesjonalnych ma PFLD-NBK-S120M40A?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-NBK-S120M40A ma certyfikat TÜV Rheinland zgodnie z IEC 61984 (ID 1111322264) w kategoriach badania typu (Type Approval), bezpieczeństwa (Safety) i regularnego nadzoru produkcji (Regular Production Surveillance). Posiada także certyfikaty CB i UKCA, oznakowanie CE oraz zgodność z RoHS (ograniczenie stosowania substancji niebezpiecznych) i REACH. Materiał obudowy uzyskał klasę palności UL94-V0, najwyższą w serii pionowej próby palności UL94 (V), co oznacza, że materiał samoczynnie gaśnie w ciągu 10 sekund bez płonących kropli. Silikonowa uszczelka O-ring zapewnia stopień ochrony IP67 po połączeniu, co oznacza pełną ochronę przed wnikaniem pyłu i czasowym zanurzeniem w wodzie do 1 m na 30 minut.\"}}, {\"@type\": \"Question\", \"name\": \"Czy PFLD-NBK-S120M40A można włączyć do istniejącego systemu rozdziału energii?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Złącza PowerFit zaprojektowano tak, aby były kompatybilne ze złączami jednobiegunowymi wiodących producentów. Kołek zwalniający umożliwia rozłączenie bez narzędzi podczas demontażu, blokada bagnetowa (wciśnij i przekręć) zatrzaskuje się w kilka sekund, a ergonomiczny gumowy uchwyt zmniejsza zmęczenie dłoni podczas długich montaży obejmujących dziesiątki połączeń. W obwodach N stosujących konwencję barw australijską i starą brytyjską (sprzed 2004 r.) czarne złącze PFLD-NBK-S120M40A zapewnia spójną identyfikację przewodów przy łączeniu złączy PowerFit z posiadanym sprzętem.\"}}, {\"@type\": \"Question\", \"name\": \"Jakie narzędzia i czynności są potrzebne do zarobienia PFLD-NBK-S120M40A?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Aby zmontować PFLD-NBK-S120M40A, zdejmij dławnicę kablową M40 i wyjmij styk. Włóż styk do izolatora i wyrównaj otwór na zawleczkę. Zdejmij izolację zewnętrzną przewodu na długości około 33 mm, a następnie nasuń tuleję redukcyjną R120 (mosiężną, posrebrzaną, dla żył o średnicy do 16,50 mm) na odsłoniętą żyłę. Wbij zawleczkę od strony fazowanej, aby prawidłowo ją osadzić. Wsuń przewód z tuleją redukcyjną do styku, a następnie dokręć obie śruby dociskowe kluczem imbusowym 5 mm z momentem co najmniej 10,5 N·m. Na koniec nakręć z powrotem dławnicę kablową. Dławnica M40 przyjmuje przewody o średnicy Ø 14 do 33 mm z wkładką CG-M4015-32 lub Ø 12 do 18 mm z wkładką CG-M4015. Przy całkowitej długości 190 mm i średnicy korpusu 32,5 mm złącze nakablowe biorcze (Drain) jest najdłuższym złączem w rodzinie PowerFit, co zapewnia dużo miejsca na prowadzenie kabla i pewny uchwyt.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLD-NBK-S120M40A\"\u003e\n  \u003ch2\u003ePobierz\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLD-NBK-S120M40A.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Pobierz kartę katalogową PFLD-NBK-S120M40A (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit jednobiegunowe (IP67) \/ 400A \/ Złącze nakablowe","offer_id":50208843006172,"sku":"PFLD-NBK-S120M40A","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLD-NBK-S120M40A-b.jpg?v=1777364435","url":"https:\/\/kupopower.com\/pl\/products\/pfld-nbk","provider":"KUPO Power","version":"1.0","type":"link"}