{"product_id":"k3442","title":"K3442 - KUPO CEE Form 125A 4-Pole Industrial Receptacle, 400V, IP67","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for K3442 --\u003e \u003c!-- Source handle: kupo-k3442-panel-female-125a-6h-ip67-3p-e-380-415v --\u003e \u003c!-- Source status: draft --\u003e \u003c!-- Source tags: CEE Form; Panel Female; 125A; 6h; IP67; 3P+E; 380-415V; IEC 60309; Screw Terminal; Waterproof; Red; White; Rust Red --\u003e \u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e \u003cstyle\u003e .kupo-section-title { margin: 1.25rem 0 1rem 0; font-size: 22px !important; font-weight: 700; line-height: 1.3; color: #005F96 !important; letter-spacing: 0; } .product-description h3 { color: #005F96 !important; font-size: 18px !important; font-weight: bold; margin-top: 1.5rem; margin-bottom: 0.75rem; line-height: 1.35; letter-spacing: 0; } .product-description, .product-description p, .product-description li { color: #222222 !important; } .kupo-mating-check table { width: 100%; border-collapse: collapse; margin: 0.75rem 0 0 0; } .kupo-mating-check th, .kupo-mating-check td { padding: 0.65rem 0.75rem; border: 1px solid #d8e6ef; text-align: left; vertical-align: top; } .kupo-mating-check th { width: 34%; background: #eef5f9; color: #222222; font-weight: 700; } \u003c\/style\u003e \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e \u003cdiv class=\"product-description\" data-sku=\"K3442\" data-voltage=\"380-415V\" data-amperage=\"125A\" data-poles=\"4\" data-ip=\"IP67\"\u003e \u003cdiv class=\"product-overview\"\u003e \u003cp\u003eAcross workshops, site power panels, and industrial equipment where three-phase industrial power needs a secure fixed outlet, the KUPO K3442 provides a waterproof 125 A CEE form panel female socket for 380-415 V systems. Its hinged cover, 6h keyed earth position, screw terminal, and flame-retardant nylon (PA) + PC housing are built for wet, dusty, or washdown-prone work areas, while the IP67 rating and IEC 60309 dimensional format help crews connect compatible CEE plugs with confidence.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"product-features\"\u003e \u003ch3\u003eKey Features\u003c\/h3\u003e \u003cul\u003e \u003cli\u003e125 A panel-mounted female CEE socket with hinged cover for fixed outlets on panels, distribution boxes, and equipment enclosures\u003c\/li\u003e \u003cli\u003eBuilt for 380-415 V three-phase industrial power with 3P+E, 4-pole configuration and 6h earth contact position\u003c\/li\u003e \u003cli\u003eIP67 protection helps seal the socket against dust and water exposure in tougher outdoor or washdown-prone locations\u003c\/li\u003e \u003cli\u003eScrew terminal termination supports secure field wiring from the rear of the panel\u003c\/li\u003e \u003cli\u003eFlame-retardant nylon (PA) + PC housing and contact carrier support insulation, impact resistance, and self-extinguishing performance\u003c\/li\u003e \u003cli\u003eBrass contacts with natural copper finish provide durable, low-resistance power transfer at sustained 125 A loads\u003c\/li\u003e \u003cli\u003eRed + white housing with rust red insert keeps the voltage family easy to recognize during setup and maintenance\u003c\/li\u003e \u003cli\u003eRated operating temperature: -25 °C to 125 °C\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv class=\"product-certifications\"\u003e \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eDesigned and manufactured according to IEC 60309-1\/2:2021 and GB\/T11918.1\/2-2014\u003c\/li\u003e \u003cli\u003eProduct data lists TUV, CB, and CE certification; the PDF also shows TUV Rheinland Certified, CB, and CE marks\u003c\/li\u003e \u003cli\u003eRoHS compliant, with non-RoHS option available where required\u003c\/li\u003e \u003cli\u003eElectrical safety data includes AC 2500 V withstand voltage and insulation resistance of 500 V DC 1 min \u0026gt; 5 MΩ\u003c\/li\u003e \u003cli\u003eDurability data includes \u0026gt; 48 h salt spray resistance with no rust and low-temperature impact testing at -25 °C\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv class=\"product-applications\"\u003e \u003ch3\u003eApplications\u003c\/h3\u003e \u003cul\u003e \u003cli\u003eFactory power distribution and machinery connections\u003c\/li\u003e \u003cli\u003eConstruction-site and maintenance power panels\u003c\/li\u003e \u003cli\u003eHeavy-duty power distribution panels and high-current industrial equipment\u003c\/li\u003e \u003cli\u003eLarge machinery, shore-power style installations, and service panels\u003c\/li\u003e \u003cli\u003eChemical plants, ports, airports, drainage, and wastewater projects\u003c\/li\u003e \u003cli\u003ePermanent CEE outlets where matching IEC 60309 plugs need a secure panel-mounted socket\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003cdiv class=\"product-compatibility\"\u003e \u003ch3\u003eCompatibility\u003c\/h3\u003e \u003cp\u003eThe KUPO K3442 is manufactured to IEC 60309 dimensional standards and is compatible with KUPO K0442. For safe mating, the connected plug or device should match the same 125A, 380-415V, 3P+E, 4-pole, IP67, and 6h ratings.\u003c\/p\u003e \u003cdiv class=\"kupo-mating-check\"\u003e \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eUse with\u003c\/th\u003e \u003ctd\u003eCEE Form connectors or receptacles with the same amperage, voltage class, pole configuration, IP rating, and earth-contact clock position.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eVerify before ordering\u003c\/th\u003e \u003ctd\u003eAmperage, voltage color, pole count, clock position, IP rating, cable diameter, and terminal size.\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth\u003eDo not use with\u003c\/th\u003e \u003ctd\u003eCEE connectors with different current ratings, different voltage classes, non-matching pole configurations, or a different earth-contact clock position.\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv class=\"product-color-conventions\"\u003e \u003ch3\u003eVoltage Color Convention\u003c\/h3\u003e \u003cimg src=\"https:\/\/pub-575371843efc4b84863e8e2a0298e68b.r2.dev\/CEE-Form_page\/IEC60309_Color_Code_Clock_Position.jpg\" alt=\"IEC 60309 CEE clock position and voltage color code diagram\" style=\"max-width: 100%; margin: 1rem 0;\"\u003e \u003cp\u003eCEE form connectors use standardized housing colors to make voltage class easy to identify at a glance. Red identifies the IEC 60309 higher-voltage three-phase range for this product, while the 6h keyed earth position helps prevent mating with incompatible systems. Always match amperage, voltage, pole configuration, IP rating, and clock position before installation.\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- Product JSON-LD structured data --\u003e \u003cscript type=\"application\/ld+json\"\u003e { \"@context\": \"https:\/\/schema.org\", \"@type\": \"Product\", \"name\": \"KUPO K3442 Panel Female - 125A 6h IP67, 3P+E, 380-415V\", \"description\": \"KUPO K3442 is a waterproof 125A 6h IP67 3P+E panel-mounted female socket with screw terminals and flame-retardant housing for industrial power distribution.\", \"brand\": { \"@type\": \"Brand\", \"name\": \"KUPO\" }, \"manufacturer\": { \"@type\": \"Organization\", \"name\": \"KUPO CO. LTD\", \"url\": \"https:\/\/www.kupopower.com\" }, \"category\": \"Electrical Connectors \u003e Industrial Plugs \u0026 Sockets \u003e CEE Form (IEC 60309)\", \"sku\": \"K3442\", \"mpn\": \"K3442\", \"image\": \"https:\/\/pub-575371843efc4b84863e8e2a0298e68b.r2.dev\/CEE-Form_page\/IEC60309_Color_Code_Clock_Position.jpg\", \"additionalProperty\": [ { \"@type\": \"PropertyValue\", \"name\": \"Product Name\", \"value\": \"K3442 Panel Female\" }, { \"@type\": \"PropertyValue\", \"name\": \"Product type\", \"value\": \"CEE Form Panel Female\" }, { \"@type\": \"PropertyValue\", \"name\": \"Series \/ collection\", \"value\": \"CEE Form\" }, { \"@type\": \"PropertyValue\", \"name\": \"Connector style\", \"value\": \"Panel-mounted female socket with hinged cover\" }, { \"@type\": \"PropertyValue\", \"name\": \"Rated current\", \"value\": \"125 A\" }, { \"@type\": \"PropertyValue\", \"name\": \"Rated voltage\", \"value\": \"380-415 V\" }, { \"@type\": \"PropertyValue\", \"name\": \"Earth contact position\", \"value\": \"6h\" }, { \"@type\": \"PropertyValue\", \"name\": \"Protection grade\", \"value\": \"IP67\" }, { \"@type\": \"PropertyValue\", \"name\": \"Poles\", \"value\": \"3P+E, 4-pole\" }, { \"@type\": \"PropertyValue\", \"name\": \"Terminal type\", \"value\": \"Screw terminal\" }, { \"@type\": \"PropertyValue\", \"name\": \"Housing color\", \"value\": \"Red + white\" }, { \"@type\": \"PropertyValue\", \"name\": \"Insert color\", \"value\": \"Rust red\" }, { \"@type\": \"PropertyValue\", \"name\": \"Withstand voltage\", \"value\": \"AC 2500 V\" }, { \"@type\": \"PropertyValue\", \"name\": \"Insulation resistance\", \"value\": \"500 V DC 1 min \u003e 5 MΩ\" }, { \"@type\": \"PropertyValue\", \"name\": \"Certification\", \"value\": \"TUV, CB, CE\" }, { \"@type\": \"PropertyValue\", \"name\": \"Environmental compliance\", \"value\": \"RoHS; non-RoHS optional\" }, { \"@type\": \"PropertyValue\", \"name\": \"Mechanical life\", \"value\": \"\u003e= 50,000 mating cycles, no load\" }, { \"@type\": \"PropertyValue\", \"name\": \"Dimensions\", \"value\": \"Dimension drawing summary: Mounting face 131 × 131 mm; mounting centers 105 × 105 mm; circular panel opening Ø 95 mm; mounting holes Ø 6.5 mm; side-view overall depth 160 mm; rear projection segments 45 mm + 115 mm; front cover outside width 130 mm; cable nominal cross-section area 16 - 50 mm². Front-view contact layout: 3P+E, 4-pole female contact layout shown Cable nominal cross-section area: 16 - 50 mm²\" }, { \"@type\": \"PropertyValue\", \"name\": \"Salt spray resistance\", \"value\": \"\u003e 48 h, no rust\" }, { \"@type\": \"PropertyValue\", \"name\": \"Impact test\", \"value\": \"-25 °C, 16 h, \u003e 0.5 kg, 25°\" }, { \"@type\": \"PropertyValue\", \"name\": \"Operating temperature\", \"value\": \"-25 °C to 125 °C\" }, { \"@type\": \"PropertyValue\", \"name\": \"Humidity\", \"value\": \"93% at 40 °C\" }, { \"@type\": \"PropertyValue\", \"name\": \"Compatible products\", \"value\": \"K0442\" }, { \"@type\": \"PropertyValue\", \"name\": \"Packing\", \"value\": \"Inner: 1 pcs \/ box; Outer: 12 pcs \/ carton\" }, { \"@type\": \"PropertyValue\", \"name\": \"Materials and Construction\", \"value\": \"Contacts: Brass, natural copper finish; Contact process: Stamping + machining; Housing: Flame-retardant nylon (PA) + PC, glow-wire 650 °C; Housing color: Red + white; Insert \/ contact carrier: Flame-retardant nylon PA, glow-wire 850 °C; Insert color: Rust red; Screw accessories: Iron \/ stainless steel; Surface treatment: Zinc plating; Manufacturing: Injection molding for housing and insert; Terminal type: Screw terminal\" }, { \"@type\": \"PropertyValue\", \"name\": \"Product Image Notes\", \"value\": \"The PDF product photo shows a panel-mounted female socket with a white panel flange, rust red female contact insert, white waterproof cover with red top insert and red main socket body, and rear screw-terminal assembly. The photo matches the 3P+E \/ 4-pole configuration and the IP67 rating shown in the headline and product table.\" }, { \"@type\": \"PropertyValue\", \"name\": \"Product Label Markings\", \"value\": \"Product photo visible marking area: Small molded \/ printed marking area on the hinged cover; detailed SKU and rating text are not reliably readable from the product photo PDF product title SKU: K3442 Electrical rating from PDF heading: 125A 6h IP67 \\\\ | 3P+E \\\\ | 380-415V Poles from PDF heading and Product Data table: 3P+E \/ 3P+E, 4-pole Protection grade from PDF heading and Product Data table: IP67 Certification marks on PDF page: TÜV Rheinland Certified, CB, CE Compliance statement in PDF text: Designed and manufactured according to IEC 60309-1\/2:2021 and GB\/T11918.1\/2-2014\" } ], \"color\": \"Red + white\", \"additionalType\": \"CEE Form Connector\" } \u003c\/script\u003e \u003c!-- ====== BEGIN FAQ + JSON SCHEMA BLOCK: K3442 ====== --\u003e \u003cstyle\u003e .kupo-faq-seo-block { margin: 3rem 0 0 0; padding: 0; border: 0; background: transparent; box-sizing: border-box; } .kupo-faq-seo-block h2 { margin: 0 0 1.6rem 0; font-size: 22px !important; font-weight: 700; line-height: 1.4; color: #005F96 !important; } .kupo-faq-seo-item { border-top: 1px solid #ececec; padding: 0.8rem 0; } .kupo-faq-seo-item:first-of-type { border-top: 0; padding-top: 0; } .kupo-faq-seo-item h3 { margin: 0 0 0.35rem 0; font-size: 17px !important; font-weight: 600; line-height: 1.45; color: #005F96 !important; } .kupo-faq-seo-item p { margin: 0; line-height: 1.6; color: #222222 !important; } \u003c\/style\u003e \u003csection class=\"kupo-faq-seo-block\" data-product-id=\"K3442\" data-category=\"CEE Form (IEC 60309)\"\u003e \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e \u003cdiv class=\"kupo-faq-seo-item\"\u003e \u003ch3\u003eWhat is the KUPO K3442 and what are its primary specifications?\u003c\/h3\u003e \u003cp\u003eThe KUPO K3442 is a 125A CEE form panel-mounted female socket with hinged cover for 380-415V power distribution. Primary specifications: Product type: Panel Female, 125 A; Rated voltage: 380-415 V; Rated current: 125 A; Earth Contact Position: 6h; Poles: 3P+E, 4-pole; Protection grade: IP67; Withstand voltage: AC 2500 V; Insulation resistance: 500 V DC 1 min \u0026gt; 5 MΩ. For K3442, the important distinction is that it is a panel-mounted female socket with hinged cover in the 125A, 380-415V, 3P+E, 4-pole, IP67, 6h earth position configuration, so it should be selected for that exact CEE form arrangement rather than a nearby SKU with a different pole count, IP grade, or mounting style.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"kupo-faq-seo-item\"\u003e \u003ch3\u003eWhat safety and compliance standards does the K3442 support?\u003c\/h3\u003e \u003cp\u003eCertifications listed in product data table: TUV, CB, CE Certification marks shown on PDF: TÜV Rheinland Certified, CB, CE Environmental compliance: RoHS; non-RoHS optional Standards referenced: IEC 60309-1\/2:2021; GB\/T11918.1\/2-2014 Withstand voltage: AC 2500 V Insulation resistance: 500 V DC 1 min \u0026gt; 5 MΩ Certification: TUV, CB, CE Salt spray resistance: \u0026gt; 48 h, no rust Impact test: -25 °C, 16 h, \u0026gt; 0.5 kg, 25°. For K3442 documentation, keep the matching K3442 product data sheet with the job file because the certification, withstand-voltage, and insulation-resistance values apply to this specific 125A IP67 panel-mounted female socket with hinged cover variant.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"kupo-faq-seo-item\"\u003e \u003ch3\u003eWhat cable and termination details are listed for the K3442?\u003c\/h3\u003e \u003cp\u003eTerminal type: Screw terminal; Dimension drawing summary: Mounting face 131 × 131 mm; mounting centers 105 × 105 mm; circular panel opening Ø 95 mm; mounting holes Ø 6.5 mm; side-view overall depth 160 mm; rear projection segments 45 mm + 115 mm; front cover outside width 130 mm; cable nominal cross-section area 16 - 50 mm².; Cable nominal cross-section area: 16 - 50 mm²; Terminal type: Screw terminal. For K3442, size the cable and gland around the listed conductor cross-section 16 - 50 mm²; terminal type Screw terminal; using the cable assumptions from a larger or smaller KUPO CEE SKU can lead to poor strain relief or an incorrect termination.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"kupo-faq-seo-item\"\u003e \u003ch3\u003eWhich product is compatible with the K3442?\u003c\/h3\u003e \u003cp\u003eThe product data lists K0442 as compatible with K3442. For safe mating, the connected product should match the electrical rating, pole configuration, IP rating, and earth contact clock position. For K3442, compatibility with K0442 depends on the same 125A, 380-415V, 3P+E, 4-pole, IP67, 6h earth position; a connector with a different current rating, voltage color class, pole layout, IP grade, or clock position should not be treated as interchangeable.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"kupo-faq-seo-item\"\u003e \u003ch3\u003eWhere is the K3442 typically used?\u003c\/h3\u003e \u003cp\u003eDesigned and manufactured according to IEC 60309-1\/2:2021 and GB\/T11918.1\/2-2014 for factory power distribution, machinery, construction sites, chemical plants, ports, airports, drainage and wastewater projects. Because K3442 is a 125A IP67 panel-mounted female socket with hinged cover for 380-415V, it fits installations that need that exact current capacity, mounting style, and environmental protection level; choose a different KUPO CEE SKU when the site requires another pole layout or ingress rating.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"kupo-faq-seo-item\"\u003e \u003ch3\u003eWhat dimensions are listed for the K3442?\u003c\/h3\u003e \u003cp\u003eDimension drawing summary: Mounting face 131 × 131 mm; mounting centers 105 × 105 mm; circular panel opening Ø 95 mm; mounting holes Ø 6.5 mm; side-view overall depth 160 mm; rear projection segments 45 mm + 115 mm; front cover outside width 130 mm; cable nominal cross-section area 16 - 50 mm². Front-view contact layout: 3P+E, 4-pole female contact layout shown Cable nominal cross-section area: 16 - 50 mm². Use the K3442 dimensions for this exact body style when checking panel space, cable bend radius, cover swing, and service clearance; similar KUPO CEE products may not share the same envelope.\u003c\/p\u003e \u003c\/div\u003e \u003c\/section\u003e \u003cscript type=\"application\/ld+json\"\u003e { \"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [ { \"@type\": \"Question\", \"name\": \"What is the KUPO K3442 and what are its primary specifications?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"The KUPO K3442 is a 125A CEE form panel-mounted female socket with hinged cover for 380-415V power distribution. Primary specifications: Product type: Panel Female, 125 A; Rated voltage: 380-415 V; Rated current: 125 A; Earth Contact Position: 6h; Poles: 3P+E, 4-pole; Protection grade: IP67; Withstand voltage: AC 2500 V; Insulation resistance: 500 V DC 1 min \u003e 5 M\\u03a9. For K3442, the important distinction is that it is a panel-mounted female socket with hinged cover in the 125A, 380-415V, 3P+E, 4-pole, IP67, 6h earth position configuration, so it should be selected for that exact CEE form arrangement rather than a nearby SKU with a different pole count, IP grade, or mounting style.\" } }, { \"@type\": \"Question\", \"name\": \"What safety and compliance standards does the K3442 support?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"Certifications listed in product data table: TUV, CB, CE Certification marks shown on PDF: T\\u00dcV Rheinland Certified, CB, CE Environmental compliance: RoHS; non-RoHS optional Standards referenced: IEC 60309-1\/2:2021; GB\/T11918.1\/2-2014 Withstand voltage: AC 2500 V Insulation resistance: 500 V DC 1 min \u003e 5 M\\u03a9 Certification: TUV, CB, CE Salt spray resistance: \u003e 48 h, no rust Impact test: -25 \\u00b0C, 16 h, \u003e 0.5 kg, 25\\u00b0. For K3442 documentation, keep the matching K3442 product data sheet with the job file because the certification, withstand-voltage, and insulation-resistance values apply to this specific 125A IP67 panel-mounted female socket with hinged cover variant.\" } }, { \"@type\": \"Question\", \"name\": \"What cable and termination details are listed for the K3442?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"Terminal type: Screw terminal; Dimension drawing summary: Mounting face 131 \\u00d7 131 mm; mounting centers 105 \\u00d7 105 mm; circular panel opening \\u00d8 95 mm; mounting holes \\u00d8 6.5 mm; side-view overall depth 160 mm; rear projection segments 45 mm + 115 mm; front cover outside width 130 mm; cable nominal cross-section area 16 - 50 mm\\u00b2.; Cable nominal cross-section area: 16 - 50 mm\\u00b2; Terminal type: Screw terminal. For K3442, size the cable and gland around the listed conductor cross-section 16 - 50 mm\\u00b2; terminal type Screw terminal; using the cable assumptions from a larger or smaller KUPO CEE SKU can lead to poor strain relief or an incorrect termination.\" } }, { \"@type\": \"Question\", \"name\": \"Which product is compatible with the K3442?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"The product data lists K0442 as compatible with K3442. For safe mating, the connected product should match the electrical rating, pole configuration, IP rating, and earth contact clock position. For K3442, compatibility with K0442 depends on the same 125A, 380-415V, 3P+E, 4-pole, IP67, 6h earth position; a connector with a different current rating, voltage color class, pole layout, IP grade, or clock position should not be treated as interchangeable.\" } }, { \"@type\": \"Question\", \"name\": \"Where is the K3442 typically used?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"Designed and manufactured according to IEC 60309-1\/2:2021 and GB\/T11918.1\/2-2014 for factory power distribution, machinery, construction sites, chemical plants, ports, airports, drainage and wastewater projects. Because K3442 is a 125A IP67 panel-mounted female socket with hinged cover for 380-415V, it fits installations that need that exact current capacity, mounting style, and environmental protection level; choose a different KUPO CEE SKU when the site requires another pole layout or ingress rating.\" } }, { \"@type\": \"Question\", \"name\": \"What dimensions are listed for the K3442?\", \"acceptedAnswer\": { \"@type\": \"Answer\", \"text\": \"Dimension drawing summary: Mounting face 131 \\u00d7 131 mm; mounting centers 105 \\u00d7 105 mm; circular panel opening \\u00d8 95 mm; mounting holes \\u00d8 6.5 mm; side-view overall depth 160 mm; rear projection segments 45 mm + 115 mm; front cover outside width 130 mm; cable nominal cross-section area 16 - 50 mm\\u00b2. Front-view contact layout: 3P+E, 4-pole female contact layout shown Cable nominal cross-section area: 16 - 50 mm\\u00b2. Use the K3442 dimensions for this exact body style when checking panel space, cable bend radius, cover swing, and service clearance; similar KUPO CEE products may not share the same envelope.\" } } ] } \u003c\/script\u003e \u003c!-- ====== END FAQ + JSON SCHEMA BLOCK: K3442 ====== --\u003e \u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e \u003cstyle\u003e .kupo-download-section { margin: 2rem 0 0 0; padding: 0; border: 0; background: transparent; box-sizing: border-box; } .kupo-download-section h2 { margin: 0 0 1rem 0; font-size: 22px !important; font-weight: 700; line-height: 1.4; color: #005F96 !important; } .kupo-download-link { display: inline-flex; align-items: center; gap: 0.4rem; font-size: 16px !important; line-height: 1.5; color: #111111 !important; font-weight: 600; text-decoration: underline; } \u003c\/style\u003e \u003csection class=\"kupo-download-section\" data-product-id=\"K3442\"\u003e \u003ch2\u003eDownload\u003c\/h2\u003e \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/K3442%20Product%20Data.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e Download K3442 Spec Sheet (PDF) \u003c\/a\u003e \u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"CEE Industrial (IEC 60309) \/ 125A \/ Panel Mount Receptacle","offer_id":51906602467548,"sku":"K3442","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/K3442.jpg?v=1782877319","url":"https:\/\/kupopower.com\/products\/k3442","provider":"KUPO Power","version":"1.0","type":"link"}