{"product_id":"kl-150smbk","title":"KL-150SMBK - K-LOK 150A Male CAM-Type Panel Mount Receptacle, Threaded Stud, Black","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-150SMBK --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-150SMBK\" data-color=\"Black\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 150A Male Panel Mount Receptacle (Thread-Stud Type) is engineered for secure, permanent installation in power distribution enclosures, distro boxes, and panel assemblies. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a threaded stud connection with mounting holes for rigid enclosure attachment, this connector delivers the structural integrity and electrical performance required by professional entertainment and industrial power systems. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ePanel-mount design with threaded stud and mounting holes for secure, vibration-resistant enclosure installation\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding conditions in permanent installations\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 150A\u003c\/li\u003e\n      \u003cli\u003eThreaded stud connection provides strong, vibration-resistant termination for panel-through wiring\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing inline connectors from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 150A Male Panel Mount Receptacle intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-150SMBK | K-LOK 150A Single-Pole Panel Mount Receptacle, Male (Thread-Stud Type), Black, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 150A Male Panel Mount Receptacle (Thread-Stud Type) is engineered for secure, permanent installation in power distribution enclosures, distro boxes, and panel assemblies. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a threaded stud connection with mounting holes for rigid enclosure attachment, this connector delivers the structural integrity and electrical performance required by professional entertainment and industrial power systems. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-150SMBK\",\n  \"mpn\": \"KL-150SMBK\",\n  \"color\": \"Black\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"150A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Mount Receptacle\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Male\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#8 to #2 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Black\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Phase A \/ General\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"5\/16\\\"-18 threaded stud\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-150SMBK\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat kind of connector is KL-150SMBK?\u003c\/h3\u003e\n    \u003cp\u003eKL-150SMBK is a 150-ampere, 600V AC\/DC single-pole male panel mount receptacle (Thread-Stud Type) from the KUPO K-LOK series. Finished in black, it belongs to the CAM-type connector family widely used across live events, film production, and temporary industrial power systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current can KL-150SMBK safely carry?\u003c\/h3\u003e\n    \u003cp\u003eKL-150SMBK is designed for a maximum continuous load of 150 amperes at up to 600V AC\/DC. The brass contacts and Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius work together to maintain safe operating temperatures even under sustained full-load conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does the black color coding on KL-150SMBK help on a busy job site?\u003c\/h3\u003e\n    \u003cp\u003eOn a crowded set or event site, identifying conductors quickly is a safety essential. Under North American NEMA\/NEC conventions, black identifies Phase A (L1), making it the go-to choice for single-phase circuits and the default lead in three-phase systems. In IEC regions, black denotes Phase B (L2). The black KL-150SMBK connector lets technicians trace circuits visually without needing to check labels or test equipment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety certifications does KL-150SMBK hold?\u003c\/h3\u003e\n    \u003cp\u003eKL-150SMBK is cUL Listed under File Number E332947, certified to UL 1691 - the Standard for Safety for Cam-Type, Locking-Type Separable Connectors. It carries a UL Enclosure Types 3R environment rating, HB \/ UL94 flame classification, and full RoHS (Restriction of Hazardous Substances) compliance.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eCan KL-150SMBK work with connectors from other brands?\u003c\/h3\u003e\n    \u003cp\u003eAbsolutely. The K-LOK 150A series uses the industry-standard CAM-type interface, so KL-150SMBK mates directly with compatible single-pole connectors regardless of manufacturer. This makes it easy to expand or upgrade your connector stock incrementally.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is KL-150SMBK installed in a panel or enclosure?\u003c\/h3\u003e\n    \u003cp\u003eKL-150SMBK mounts directly to power distribution enclosures, distro boxes, and panel assemblies using its threaded stud connection and dedicated mounting holes. Once secured, the connector provides a permanent, vibration-resistant termination point that mates with standard CAM-type inline connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What kind of connector is KL-150SMBK?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-150SMBK is a 150-ampere, 600V AC\/DC single-pole male panel mount receptacle (Thread-Stud Type) from the KUPO K-LOK series. Finished in black, it belongs to the CAM-type connector family widely used across live events, film production, and temporary industrial power systems.\"}}, {\"@type\": \"Question\", \"name\": \"How much current can KL-150SMBK safely carry?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-150SMBK is designed for a maximum continuous load of 150 amperes at up to 600V AC\/DC. The brass contacts and Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius work together to maintain safe operating temperatures even under sustained full-load conditions.\"}}, {\"@type\": \"Question\", \"name\": \"How does the black color coding on KL-150SMBK help on a busy job site?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"On a crowded set or event site, identifying conductors quickly is a safety essential. Under North American NEMA\/NEC conventions, black identifies Phase A (L1), making it the go-to choice for single-phase circuits and the default lead in three-phase systems. In IEC regions, black denotes Phase B (L2). The black KL-150SMBK connector lets technicians trace circuits visually without needing to check labels or test equipment.\"}}, {\"@type\": \"Question\", \"name\": \"What safety certifications does KL-150SMBK hold?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-150SMBK is cUL Listed under File Number E332947, certified to UL 1691 - the Standard for Safety for Cam-Type, Locking-Type Separable Connectors. It carries a UL Enclosure Types 3R environment rating, HB \/ UL94 flame classification, and full RoHS (Restriction of Hazardous Substances) compliance.\"}}, {\"@type\": \"Question\", \"name\": \"Can KL-150SMBK work with connectors from other brands?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Absolutely. The K-LOK 150A series uses the industry-standard CAM-type interface, so KL-150SMBK mates directly with compatible single-pole connectors regardless of manufacturer. This makes it easy to expand or upgrade your connector stock incrementally.\"}}, {\"@type\": \"Question\", \"name\": \"How is KL-150SMBK installed in a panel or enclosure?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-150SMBK mounts directly to power distribution enclosures, distro boxes, and panel assemblies using its threaded stud connection and dedicated mounting holes. Once secured, the connector provides a permanent, vibration-resistant termination point that mates with standard CAM-type inline connectors.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-150SMBK\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/KL-150SMBK%20Data%20Sheet.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download KL-150SMBK Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 150A \/ Panel Mount Receptacle","offer_id":50208818430172,"sku":"KL-150SMBK","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-150SMBK.jpg?v=1777362798","url":"https:\/\/kupopower.com\/products\/kl-150smbk","provider":"KUPO Power","version":"1.0","type":"link"}