{"product_id":"kl-150smbn","title":"KL-150SMBN - K-LOK 150A Male CAM-Type Panel Mount Receptacle, Threaded Stud, Brown","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-150SMBN --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-150SMBN\" data-color=\"Brown\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 150A Male Panel Mount Receptacle (Thread-Stud Type) is engineered for secure, permanent installation in power distribution enclosures, distro boxes, and panel assemblies. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a threaded stud connection with mounting holes for rigid enclosure attachment, this connector delivers the structural integrity and electrical performance required by professional entertainment and industrial power systems. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ePanel-mount design with threaded stud and mounting holes for secure, vibration-resistant enclosure installation\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding conditions in permanent installations\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 150A\u003c\/li\u003e\n      \u003cli\u003eThreaded stud connection provides strong, vibration-resistant termination for panel-through wiring\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing inline connectors from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 150A Male Panel Mount Receptacle intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-150SMBN | K-LOK 150A Single-Pole Panel Mount Receptacle, Male (Thread-Stud Type), Brown, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 150A Male Panel Mount Receptacle (Thread-Stud Type) is engineered for secure, permanent installation in power distribution enclosures, distro boxes, and panel assemblies. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a threaded stud connection with mounting holes for rigid enclosure attachment, this connector delivers the structural integrity and electrical performance required by professional entertainment and industrial power systems. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-150SMBN\",\n  \"mpn\": \"KL-150SMBN\",\n  \"color\": \"Brown\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"150A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Mount Receptacle\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Male\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#8 to #2 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Brown\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Phase A (IEC)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"5\/16\\\"-18 threaded stud\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-150SMBN\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWho should use KL-150SMBN and why?\u003c\/h3\u003e\n    \u003cp\u003eLighting technicians, electricians, and power distribution professionals working with 150A temporary power systems will benefit from KL-150SMBN. Its brown housing provides instant visual phase identification, while the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius ensures durability in demanding field conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat voltage and amperage is KL-150SMBN rated for?\u003c\/h3\u003e\n    \u003cp\u003eKL-150SMBN carries a maximum rating of 150A and 600V AC\/DC. It accepts wire gauges from #8 to #2 AWG, making it suitable for the conductor sizes typically used in 150-amp power distribution circuits.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhy choose the brown version of the K-LOK 150A male panel mount receptacle?\u003c\/h3\u003e\n    \u003cp\u003eBrown designates Phase A (L1) under IEC 60446 conventions used across Europe, the UK, Asia, and Australia. For productions touring internationally or venues hosting global acts, brown connectors ensure IEC-standard phase identification is always available. Choosing KL-150SMBN in brown ensures your power distribution system follows established color conventions, speeding up setup and reducing wiring errors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs KL-150SMBN UL listed and what does that mean?\u003c\/h3\u003e\n    \u003cp\u003eYes. KL-150SMBN is cUL Listed under File Number E332947, meaning it has been independently tested and certified to UL 1691 safety standards by a Nationally Recognized Testing Laboratory. This certification is required for professional power distribution in most North American jurisdictions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat industries commonly use KL-150SMBN?\u003c\/h3\u003e\n    \u003cp\u003eKL-150SMBN is widely used in broadcast operations and outside broadcast (OB) van power distribution. Its 150A \/ 600V AC\/DC rating, combined with CAM-type universal compatibility and brown phase coding, makes it a versatile choice across the entertainment, construction, and industrial sectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat housing material is used in KL-150SMBN and why does it matter?\u003c\/h3\u003e\n    \u003cp\u003eKL-150SMBN uses a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius. Santoprene TPV delivers outstanding resistance to heat, chemicals, and UV exposure while maintaining flexibility across a wide temperature range - essential properties for connectors installed in enclosures that may face extreme operating environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Who should use KL-150SMBN and why?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Lighting technicians, electricians, and power distribution professionals working with 150A temporary power systems will benefit from KL-150SMBN. Its brown housing provides instant visual phase identification, while the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius ensures durability in demanding field conditions.\"}}, {\"@type\": \"Question\", \"name\": \"What voltage and amperage is KL-150SMBN rated for?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-150SMBN carries a maximum rating of 150A and 600V AC\/DC. It accepts wire gauges from #8 to #2 AWG, making it suitable for the conductor sizes typically used in 150-amp power distribution circuits.\"}}, {\"@type\": \"Question\", \"name\": \"Why choose the brown version of the K-LOK 150A male panel mount receptacle?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Brown designates Phase A (L1) under IEC 60446 conventions used across Europe, the UK, Asia, and Australia. For productions touring internationally or venues hosting global acts, brown connectors ensure IEC-standard phase identification is always available. Choosing KL-150SMBN in brown ensures your power distribution system follows established color conventions, speeding up setup and reducing wiring errors.\"}}, {\"@type\": \"Question\", \"name\": \"Is KL-150SMBN UL listed and what does that mean?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. KL-150SMBN is cUL Listed under File Number E332947, meaning it has been independently tested and certified to UL 1691 safety standards by a Nationally Recognized Testing Laboratory. This certification is required for professional power distribution in most North American jurisdictions.\"}}, {\"@type\": \"Question\", \"name\": \"What industries commonly use KL-150SMBN?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-150SMBN is widely used in broadcast operations and outside broadcast (OB) van power distribution. Its 150A \/ 600V AC\/DC rating, combined with CAM-type universal compatibility and brown phase coding, makes it a versatile choice across the entertainment, construction, and industrial sectors.\"}}, {\"@type\": \"Question\", \"name\": \"What housing material is used in KL-150SMBN and why does it matter?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-150SMBN uses a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius. Santoprene TPV delivers outstanding resistance to heat, chemicals, and UV exposure while maintaining flexibility across a wide temperature range - essential properties for connectors installed in enclosures that may face extreme operating environments.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-150SMBN\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/KL-150SMBN%20Data%20Sheet.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download KL-150SMBN Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 150A \/ Panel Mount Receptacle","offer_id":50208818462940,"sku":"KL-150SMBN","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-150SMBN.jpg?v=1777362799","url":"https:\/\/kupopower.com\/products\/kl-150smbn","provider":"KUPO Power","version":"1.0","type":"link"}