{"product_id":"kl-400lfgy","title":"KL-400LFGY - K-LOK 400A Female CAM-Type Line Connector, Grey","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400LFGY --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400LFGY\" data-color=\"Grey\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Female Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eNon-conductive POM (Polyoxymethylene) retaining screw locks the brass contact firmly in position, eliminating accidental current paths for safer operation\u003c\/li\u003e\n      \u003cli\u003ePOM insulation sleeve adds heat resistance and structural strength to the contact assembly\u003c\/li\u003e\n      \u003cli\u003eRibbed Santoprene TPV housing provides a secure, slip-free grip even when wearing work gloves\u003c\/li\u003e\n      \u003cli\u003eAlignment arrow ensures correct orientation for fast, error-free mating every time\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding site conditions and extreme temperatures\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors with redundant cable retention\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing power infrastructure from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Female In-Line Connector intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400LFGY | K-LOK 400A Single-Pole Line Connector, Female, Grey, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Female Line Connector is engineered for heavy-duty reliability and safety in high-current temporary power distribution. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a non-conductive POM (Polyoxymethylene) retaining screw that eliminates accidental current paths, this connector delivers the mechanical strength and electrical performance demanded by large-scale entertainment productions and industrial applications handling up to 400 amperes. The modular, tool-free design enables rapid field assembly and disassembly, while full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution systems.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400LFGY\",\n  \"mpn\": \"KL-400LFGY\",\n  \"color\": \"Grey\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Female\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Grey\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Neutral (IEC)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Retaining Screw Material\",\n      \"value\": \"POM (Polyoxymethylene), Non-conductive\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screws\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400LFGY\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWho should use KL-400LFGY and why?\u003c\/h3\u003e\n    \u003cp\u003eLighting technicians, electricians, and power distribution professionals working with 400A temporary power systems will benefit from KL-400LFGY. Its grey housing provides instant visual phase identification, while the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius ensures durability in demanding field conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat voltage and amperage is KL-400LFGY rated for?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFGY carries a maximum rating of 400A and 600V AC\/DC. It accepts wire gauges from #6 to 4\/0 AWG, making it suitable for the conductor sizes typically used in 400-amp power distribution circuits.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhy choose the grey version of the K-LOK 400A female line connector?\u003c\/h3\u003e\n    \u003cp\u003eGrey represents Phase C (L3) - and in some IEC applications, Neutral - under the international color code. Adding grey to the connector inventory ensures full IEC three-phase coverage alongside brown and black. Choosing KL-400LFGY in grey ensures your power distribution system follows established color conventions, speeding up setup and reducing wiring errors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs KL-400LFGY UL listed and what does that mean?\u003c\/h3\u003e\n    \u003cp\u003eYes. KL-400LFGY is cUL Listed under File Number E332947, meaning it has been independently tested and certified to UL 1691 safety standards by a Nationally Recognized Testing Laboratory. This certification is required for professional power distribution in most North American jurisdictions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat industries commonly use KL-400LFGY?\u003c\/h3\u003e\n    \u003cp\u003eKL-400LFGY is widely used in rental house and staging company inventories serving diverse entertainment clients. Its 400A \/ 600V AC\/DC rating, combined with CAM-type universal compatibility and grey phase coding, makes it a versatile choice across the entertainment, construction, and industrial sectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat makes KL-400LFGY easy to use during fast-paced setups?\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK tool-free design means KL-400LFGY can be assembled and disassembled without specialized equipment. The ribbed Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius provides a secure grip even with work gloves, and the alignment arrow guides correct mating orientation - cutting connection time on busy sets and stages.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Who should use KL-400LFGY and why?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Lighting technicians, electricians, and power distribution professionals working with 400A temporary power systems will benefit from KL-400LFGY. Its grey housing provides instant visual phase identification, while the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius ensures durability in demanding field conditions.\"}}, {\"@type\": \"Question\", \"name\": \"What voltage and amperage is KL-400LFGY rated for?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFGY carries a maximum rating of 400A and 600V AC\/DC. It accepts wire gauges from #6 to 4\/0 AWG, making it suitable for the conductor sizes typically used in 400-amp power distribution circuits.\"}}, {\"@type\": \"Question\", \"name\": \"Why choose the grey version of the K-LOK 400A female line connector?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Grey represents Phase C (L3) - and in some IEC applications, Neutral - under the international color code. Adding grey to the connector inventory ensures full IEC three-phase coverage alongside brown and black. Choosing KL-400LFGY in grey ensures your power distribution system follows established color conventions, speeding up setup and reducing wiring errors.\"}}, {\"@type\": \"Question\", \"name\": \"Is KL-400LFGY UL listed and what does that mean?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. KL-400LFGY is cUL Listed under File Number E332947, meaning it has been independently tested and certified to UL 1691 safety standards by a Nationally Recognized Testing Laboratory. This certification is required for professional power distribution in most North American jurisdictions.\"}}, {\"@type\": \"Question\", \"name\": \"What industries commonly use KL-400LFGY?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400LFGY is widely used in rental house and staging company inventories serving diverse entertainment clients. Its 400A \/ 600V AC\/DC rating, combined with CAM-type universal compatibility and grey phase coding, makes it a versatile choice across the entertainment, construction, and industrial sectors.\"}}, {\"@type\": \"Question\", \"name\": \"What makes KL-400LFGY easy to use during fast-paced setups?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The K-LOK tool-free design means KL-400LFGY can be assembled and disassembled without specialized equipment. The ribbed Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius provides a secure grip even with work gloves, and the alignment arrow guides correct mating orientation - cutting connection time on busy sets and stages.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400LFGY\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/KL-400LFGY%20Data%20Sheet.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download KL-400LFGY Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Inline Connector","offer_id":50208818790620,"sku":"KL-400LFGY","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400LFGY.jpg?v=1777362807","url":"https:\/\/kupopower.com\/products\/kl-400lfgy","provider":"KUPO Power","version":"1.0","type":"link"}