{"product_id":"kl-400ssfg","title":"KL-400SSFG - K-LOK 400A Female CAM-Type Panel Mount Receptacle, Double Set Screw, Green","description":"\u003c!-- KUPO Shopify paste-ready combined HTML for KL-400SSFG --\u003e\n\u003c!-- Includes product description, Product JSON-LD, FAQ, FAQ JSON-LD, and Download section. --\u003e\n\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\n\u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"product-description\" data-sku=\"KL-400SSFG\" data-color=\"Green\"\u003e\n\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe KUPO K-LOK 400A Female Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eDouble set screw panel-mount design provides redundant cable retention for maximum security in permanent installations\u003c\/li\u003e\n      \u003cli\u003eSantoprene TPV housing rated to 105 degrees Celsius withstands demanding conditions in fixed enclosure installations\u003c\/li\u003e\n      \u003cli\u003eBrass contacts deliver reliable, low-resistance electrical connections for sustained high-current loads up to 400A\u003c\/li\u003e\n      \u003cli\u003eDouble set screw termination accommodates #6 AWG (American Wire Gauge) to 4\/0 AWG conductors\u003c\/li\u003e\n      \u003cli\u003eMounting holes enable secure attachment to enclosures, distro boxes, and panel assemblies\u003c\/li\u003e\n      \u003cli\u003eUniversal CAM-type compatibility integrates seamlessly with existing inline connectors from multiple manufacturers\u003c\/li\u003e\n      \u003cli\u003ecUL Listed ensures compliance with North American safety standards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003ecUL Listed - File Number E332947\u003c\/li\u003e\n      \u003cli\u003eUL 1691 - Standard for Safety for Cam-Type, Locking-Type Separable Connectors\u003c\/li\u003e\n      \u003cli\u003eEnvironment Rating: UL Enclosure Types 3R\u003c\/li\u003e\n      \u003cli\u003eFlame Class: HB \/ UL94\u003c\/li\u003e\n      \u003cli\u003eRoHS (Restriction of Hazardous Substances) Compliant\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eConcert touring and live event production\u003c\/li\u003e\n      \u003cli\u003eFilm, television, and studio power distribution\u003c\/li\u003e\n      \u003cli\u003eTemporary construction site power\u003c\/li\u003e\n      \u003cli\u003eTheme park and entertainment venue installations\u003c\/li\u003e\n      \u003cli\u003eTrade shows and exhibition power systems\u003c\/li\u003e\n      \u003cli\u003eIndustrial temporary power connections\u003c\/li\u003e\n      \u003cli\u003eBroadcast and outside broadcast (OB) van power\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe K-LOK 400A Female Panel Mount Receptacle intermates with standard CAM-type single-pole connectors from all major manufacturers, enabling seamless integration into existing power distribution systems without requiring a full infrastructure change.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003c!-- Product JSON-LD structured data --\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"KL-400SSFG | K-LOK 400A Single-Pole Panel Mount Receptacle, Female (Double Set Screw Type), Green, 600V Maximum\",\n  \"description\": \"The KUPO K-LOK 400A Female Panel Mount Receptacle (Double Set Screw Type) is engineered for secure, permanent installation in high-current power distribution enclosures and panel assemblies where double set screw termination is preferred. Featuring a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius, brass contacts for superior conductivity, and a double set screw connection for robust cable retention, this connector delivers the structural integrity and electrical performance required by large-scale entertainment productions and industrial power systems handling up to 400 amperes. Full interoperability with standard CAM-type connectors ensures seamless integration into existing power distribution infrastructure.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e CAM-Type\",\n  \"sku\": \"KL-400SSFG\",\n  \"mpn\": \"KL-400SSFG\",\n  \"color\": \"Green\",\n  \"material\": \"Santoprene TPV\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"600V AC\/DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Mount Receptacle (Double Set Screw)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Gender\",\n      \"value\": \"Female\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Terminal Accommodation\",\n      \"value\": \"#6 to 4\/0 AWG\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Base Compound\",\n      \"value\": \"Santoprene TPV, rated to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL File Number\",\n      \"value\": \"E332947\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"HB \/ UL94\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Environment Rating\",\n      \"value\": \"UL Enclosure Types 3R\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"CAM-Type Compatible\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Color\",\n      \"value\": \"Green\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Ground \/ Earth\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Type\",\n      \"value\": \"Double set screw (2 x 7\/32\\\" socket head)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"Up to 105 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"RoHS Compliant\",\n      \"value\": \"Yes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"UL Standard\",\n      \"value\": \"UL 1691\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003cstyle\u003e\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item {\n  border-top: 1px solid #ececec;\n  padding: 0.8rem 0;\n}\n.kupo-faq-seo-item:first-of-type {\n  border-top: 0;\n  padding-top: 0;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"KL-400SSFG\" data-category=\"K-LOK Power Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat is KL-400SSFG and what is it designed for?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFG is a KUPO K-LOK 400A single-pole female panel mount receptacle (Double Set Screw Type) with a green housing, rated for 600V AC\/DC maximum. It is engineered for heavy-duty temporary power distribution in entertainment, industrial, and event production settings. The green color coding aids rapid phase identification on the job site.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat wire sizes does KL-400SSFG accept?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFG accommodates conductors ranging from #6 to 4\/0 AWG. The brass contact assembly ensures reliable electrical performance across this full conductor range, supporting up to 400A at 600V AC\/DC.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhich electrical phase does the green color represent on KL-400SSFG?\u003c\/h3\u003e\n    \u003cp\u003eGreen identifies the Ground (Earth \/ PE) conductor across North American and many international standards. Ground integrity is critical for personnel safety, and a distinct green connector ensures the safety earth is never confused with a current-carrying phase. Having a dedicated green connector in your inventory means phase assignments are physically enforced, minimizing the chance of cross-phase connection errors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does KL-400SSFG protect against electrical hazards?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFG incorporates multiple safety features: the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius resists heat and impact, brass contacts minimize resistive heating, and the design meets UL 1691 safety requirements under cUL Listed E332947. The UL Enclosure Types 3R rating also provides protection in wet or outdoor conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs KL-400SSFG compatible with other CAM-type connectors?\u003c\/h3\u003e\n    \u003cp\u003eYes. KL-400SSFG follows the universal CAM-type single-pole connector standard and intermates with CAM-type connectors from all major manufacturers. This cross-brand compatibility means you can integrate K-LOK connectors into existing power distribution systems without replacing your entire inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat housing material is used in KL-400SSFG and why does it matter?\u003c\/h3\u003e\n    \u003cp\u003eKL-400SSFG uses a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius. Santoprene TPV is chosen for its combination of rubber-like flexibility, heat resistance up to 105 degrees Celsius, and resistance to oils, chemicals, and weathering - ideal for panel mount receptacles that remain permanently installed in demanding environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is KL-400SSFG and what is it designed for?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFG is a KUPO K-LOK 400A single-pole female panel mount receptacle (Double Set Screw Type) with a green housing, rated for 600V AC\/DC maximum. It is engineered for heavy-duty temporary power distribution in entertainment, industrial, and event production settings. The green color coding aids rapid phase identification on the job site.\"}}, {\"@type\": \"Question\", \"name\": \"What wire sizes does KL-400SSFG accept?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFG accommodates conductors ranging from #6 to 4\/0 AWG. The brass contact assembly ensures reliable electrical performance across this full conductor range, supporting up to 400A at 600V AC\/DC.\"}}, {\"@type\": \"Question\", \"name\": \"Which electrical phase does the green color represent on KL-400SSFG?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Green identifies the Ground (Earth \/ PE) conductor across North American and many international standards. Ground integrity is critical for personnel safety, and a distinct green connector ensures the safety earth is never confused with a current-carrying phase. Having a dedicated green connector in your inventory means phase assignments are physically enforced, minimizing the chance of cross-phase connection errors.\"}}, {\"@type\": \"Question\", \"name\": \"How does KL-400SSFG protect against electrical hazards?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFG incorporates multiple safety features: the Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius resists heat and impact, brass contacts minimize resistive heating, and the design meets UL 1691 safety requirements under cUL Listed E332947. The UL Enclosure Types 3R rating also provides protection in wet or outdoor conditions.\"}}, {\"@type\": \"Question\", \"name\": \"Is KL-400SSFG compatible with other CAM-type connectors?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. KL-400SSFG follows the universal CAM-type single-pole connector standard and intermates with CAM-type connectors from all major manufacturers. This cross-brand compatibility means you can integrate K-LOK connectors into existing power distribution systems without replacing your entire inventory.\"}}, {\"@type\": \"Question\", \"name\": \"What housing material is used in KL-400SSFG and why does it matter?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"KL-400SSFG uses a Santoprene TPV (Thermoplastic Vulcanizate) housing rated to 105 degrees Celsius. Santoprene TPV is chosen for its combination of rubber-like flexibility, heat resistance up to 105 degrees Celsius, and resistance to oils, chemicals, and weathering - ideal for panel mount receptacles that remain permanently installed in demanding environments.\"}}]}\u003c\/script\u003e\n\u003c!-- ==================== DOWNLOAD SECTION ==================== --\u003e\n\u003cstyle\u003e\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"KL-400SSFG\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003c!-- No spec-sheet download link provided in source CSV. --\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"K-LOK Single Pole (CAM-Type) \/ 400A \/ Panel Mount Receptacle","offer_id":50208820658396,"sku":"KL-400SSFG","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/KL-400SSFG_b.jpg?v=1777362835","url":"https:\/\/kupopower.com\/products\/kl-400ssfg","provider":"KUPO Power","version":"1.0","type":"link"}