{"product_id":"pfld-1r","title":"PFLD-1R-S120M40A - PowerFit 400A Drain Line Connector, Red (L1)","description":"\u003c!-- Combined Shopify product HTML for PFLD-1R-S120M40A --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLD-1R-S120M40A\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Line Drain Connector (Red) | PFLD-1R-S120M40A | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLD-1R-S120M40A\" data-color=\"Red\"\u003e\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eWhen power systems traverse multiple electrical standards and jurisdictions, phase identification becomes critical to safe installation and operation. The PowerFit 400A Line Drain connector in red addresses the needs of international work sites, multi-standard equipment configurations, and legacy system upgrades where red designates the primary line conductor under both Australian (AS\/NZS 3000) and UK legacy (BS 7671) conventions. This connector combines the electrical robustness of 400A continuous rating with a color-coded housing that aligns with recognized international phase standards, delivering mechanical reliability and regulatory clarity across borders.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003e400A continuous current capacity (120mm² cable); 660A continuous (240mm² cable)\u003c\/li\u003e\n      \u003cli\u003eFemale contact design ensures positive mating with Line Source connector pin\u003c\/li\u003e\n      \u003cli\u003ePush-and-twist connection mechanism with mechanical positive lock\u003c\/li\u003e\n      \u003cli\u003eSilver-plated brass contact maintains 0.1m Ohms contact resistance under continuous load\u003c\/li\u003e\n      \u003cli\u003eThermoplastic body with UL94-V0 flame retardancy for industrial safety requirements\u003c\/li\u003e\n      \u003cli\u003eM40 x 1.5 cable gland with rubber sealing bushing delivers IP67 protection when mated\u003c\/li\u003e\n      \u003cli\u003eSilicone O-ring creates reliable water and dust barrier after connection closure\u003c\/li\u003e\n      \u003cli\u003eErgonomic rubber grip provides safe handling and confident connector engagement in field conditions\u003c\/li\u003e\n      \u003cli\u003ePOM cotter pin (longer variant for Line Drain) provides mechanical safety lock; not reusable after removal\u003c\/li\u003e\n      \u003cli\u003eR120 brass reduction sleeve accepts cable diameters up to 16.50mm\u003c\/li\u003e\n      \u003cli\u003eSet screw torque specification: 10.5 N\/meter minimum ensures repeatable electrical contact\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eTÜV Rheinland certified (ID 1111303479) for international market compliance\u003c\/li\u003e\n      \u003cli\u003eCE and RoHS compliant for European regulatory requirements\u003c\/li\u003e\n      \u003cli\u003eREACH compliant for controlled substance compliance\u003c\/li\u003e\n      \u003cli\u003eUL94-V0 flame retardancy rating\u003c\/li\u003e\n      \u003cli\u003eIP67 rated while mated (complete dust protection, temporary submersion to 1 meter depth)\u003c\/li\u003e\n      \u003cli\u003e1000V AC \/ 1500V DC maximum operating voltage; 4500V AC test voltage\u003c\/li\u003e\n      \u003cli\u003eShort circuit rating: Up to 35.5kA with insulation resistance exceeding 5000 megohms at 500V AC\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eInternational touring operations requiring multi-standard electrical compliance\u003c\/li\u003e\n      \u003cli\u003eMulti-national industrial equipment installations with phase color variation\u003c\/li\u003e\n      \u003cli\u003eDual-standard or legacy system upgrades (UK old BS 7671 to modern IEC transitions)\u003c\/li\u003e\n      \u003cli\u003eAustralian and New Zealand power distribution systems with AS\/NZS 3000 phase coding\u003c\/li\u003e\n      \u003cli\u003eRental equipment pools serving diverse geographic markets and electrical jurisdictions\u003c\/li\u003e\n      \u003cli\u003eTemporary power distribution where clear color identification prevents misconnection hazards\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe PowerFit 400A Line Drain connector maintains compatibility with major brands of single-pole power connectors through its standardized M40 x 1.5 cable gland interface and push-and-twist mating geometry. Cable and connector impedance matching across brand boundaries requires verification of electrical specifications and mechanical tolerances with your source connector supplier to ensure safe operating performance and regulatory compliance.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLD-1R-S120M40A | PowerFit 400A Line Drain, L1 (Phase A) Red (Alternate L1 \/ Australian)\",\n  \"description\": \"KUPO PowerFit 400A Line Drain single-pole connector with red housing for Alternate L1 \/ Australian power distribution systems. Female Contact, M40 cable gland with sealing bushing, IP67 rated when mated, silver-plated brass contacts, dual-rated 400A\/660A, 1000V AC \/ 1500V DC maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLD-1R-S120M40A\",\n  \"mpn\": \"PFLD-1R-S120M40A\",\n  \"color\": \"Red\",\n  \"material\": \"Non-conductive thermoplastic housing; Brass silver-plated contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC \/ 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A continuous (120mm\u0026sup2; cable) \/ 660A continuous (240mm\u0026sup2; cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5 kiloamperes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Drain (Female Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-Twist Lock\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing (Inner Diameter: 22mm and 33mm)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Set Screw Torque\",\n      \"value\": \"10.5 N\/meter minimum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"TUV Certification ID\",\n      \"value\": \"1111303479\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV Rheinland, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L1 (Phase A) (Alternate L1 \/ Australian)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Red\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLD-1R-S120M40A\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat kind of connector is PFLD-1R-S120M40A and where does it fit in the power chain?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-1R-S120M40A is a KUPO PowerFit 400A line drain connector with a red housing, identifying Line 1 (L1) under Australia conventions. As the drain side of an inline cable connection, it receives the mating source contact and provides a sealed, IP67-rated junction when coupled. The red housing enables instant visual identification of the L1 conductor across cable runs. It is commonly deployed in film location shoot applications. On-location film production often runs power through variable terrain and weather conditions that studio stages never face.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow much current can PFLD-1R-S120M40A safely handle in continuous operation?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-1R-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The insulation resistance exceeds 5000 megaohms at 500V AC, and the test voltage rating of 4500V AC provides substantial safety margin. The short circuit rating of up to 35.5 kiloamperes means the connector can withstand fault conditions without catastrophic failure.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the red housing on PFLD-1R-S120M40A represent under Australia standards?\u003c\/h3\u003e\n    \u003cp\u003eAustralian wiring standards designate red as the Line 1 (L1) conductor. The Australian three-phase color set is red (L1), white (L2), and blue (L3). Red L1 is also used in parts of New Zealand and some Asia-Pacific regions that follow Australian electrical practices. On the Line Drain connector, the red housing is visible along the full 190mm body length, making L1 identification easy even when cables are bundled tightly. The ergonomic rubber grip section also carries the color, so technicians can identify the phase while handling the connector. Using the correct L1 color prevents phase rotation errors that can damage three-phase motors and sensitive equipment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFLD-1R-S120M40A certified for professional use?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-1R-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The silicone O-ring seal contributes to the IP67 rating when mated, meaning the connection is fully protected against dust ingress and temporary immersion in water up to 1 meter for 30 minutes.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat tools and steps are needed to terminate PFLD-1R-S120M40A?\u003c\/h3\u003e\n    \u003cp\u003eTo assemble PFLD-1R-S120M40A, remove the M40 cable gland and extract the contact. Insert the contact into the insulator and align the cotter pin hole. Strip back the cable jacket by approximately 33mm, then slide the R120 reduction sleeve (brass with silver plating, up to 16.50mm wire diameter) over the exposed conductor. Hammer the cotter pin in from its chamfered side for proper seating. Slide the cable with reduction sleeve into the contact, then tighten both set screws using a 5mm hex key to a minimum of 10.5 N\/m. Finally, thread the cable gland back on. The M40 gland includes two rubber bushings (inner diameter 23mm and 33mm) for flexibility with different cable sizes. At 190mm total length with a 32.5mm body diameter, the Line Drain is the longest connector in the PowerFit family, providing ample space for cable management and a secure grip surface.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat advantages does PFLD-1R-S120M40A offer over conventional CAM-type connectors?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-1R-S120M40A offers several meaningful improvements over conventional single-pole power connectors: the 1000V AC \/ 1500V DC voltage rating exceeds the typical 600V maximum of traditional alternatives; silver-plated brass contacts deliver lower contact resistance (0.1 milliohms) than plain brass; the integrated M40 cable gland with sealing bushing provides cable strain relief and environmental protection in a single assembly; IP67 protection when mated provides dust-tight and waterproof sealing that most single-pole connectors lack. These features, combined with TUV Rheinland certification and the phase-encoded red housing for L1 identification, make PowerFit a generation ahead of traditional designs.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What kind of connector is PFLD-1R-S120M40A and where does it fit in the power chain?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-1R-S120M40A is a KUPO PowerFit 400A line drain connector with a red housing, identifying Line 1 (L1) under Australia conventions. As the drain side of an inline cable connection, it receives the mating source contact and provides a sealed, IP67-rated junction when coupled. The red housing enables instant visual identification of the L1 conductor across cable runs. It is commonly deployed in film location shoot applications. On-location film production often runs power through variable terrain and weather conditions that studio stages never face.\"}}, {\"@type\": \"Question\", \"name\": \"How much current can PFLD-1R-S120M40A safely handle in continuous operation?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-1R-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The insulation resistance exceeds 5000 megaohms at 500V AC, and the test voltage rating of 4500V AC provides substantial safety margin. The short circuit rating of up to 35.5 kiloamperes means the connector can withstand fault conditions without catastrophic failure.\"}}, {\"@type\": \"Question\", \"name\": \"What does the red housing on PFLD-1R-S120M40A represent under Australia standards?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Australian wiring standards designate red as the Line 1 (L1) conductor. The Australian three-phase color set is red (L1), white (L2), and blue (L3). Red L1 is also used in parts of New Zealand and some Asia-Pacific regions that follow Australian electrical practices. On the Line Drain connector, the red housing is visible along the full 190mm body length, making L1 identification easy even when cables are bundled tightly. The ergonomic rubber grip section also carries the color, so technicians can identify the phase while handling the connector. Using the correct L1 color prevents phase rotation errors that can damage three-phase motors and sensitive equipment.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFLD-1R-S120M40A certified for professional use?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-1R-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The silicone O-ring seal contributes to the IP67 rating when mated, meaning the connection is fully protected against dust ingress and temporary immersion in water up to 1 meter for 30 minutes.\"}}, {\"@type\": \"Question\", \"name\": \"What tools and steps are needed to terminate PFLD-1R-S120M40A?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"To assemble PFLD-1R-S120M40A, remove the M40 cable gland and extract the contact. Insert the contact into the insulator and align the cotter pin hole. Strip back the cable jacket by approximately 33mm, then slide the R120 reduction sleeve (brass with silver plating, up to 16.50mm wire diameter) over the exposed conductor. Hammer the cotter pin in from its chamfered side for proper seating. Slide the cable with reduction sleeve into the contact, then tighten both set screws using a 5mm hex key to a minimum of 10.5 N\/m. Finally, thread the cable gland back on. The M40 gland includes two rubber bushings (inner diameter 23mm and 33mm) for flexibility with different cable sizes. At 190mm total length with a 32.5mm body diameter, the Line Drain is the longest connector in the PowerFit family, providing ample space for cable management and a secure grip surface.\"}}, {\"@type\": \"Question\", \"name\": \"What advantages does PFLD-1R-S120M40A offer over conventional CAM-type connectors?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-1R-S120M40A offers several meaningful improvements over conventional single-pole power connectors: the 1000V AC \/ 1500V DC voltage rating exceeds the typical 600V maximum of traditional alternatives; silver-plated brass contacts deliver lower contact resistance (0.1 milliohms) than plain brass; the integrated M40 cable gland with sealing bushing provides cable strain relief and environmental protection in a single assembly; IP67 protection when mated provides dust-tight and waterproof sealing that most single-pole connectors lack. These features, combined with TUV Rheinland certification and the phase-encoded red housing for L1 identification, make PowerFit a generation ahead of traditional designs.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLD-1R-S120M40A\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLD-1R-S120M40A.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLD-1R-S120M40A Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 400A \/ Inline Connector","offer_id":50208842547420,"sku":"PFLD-1R-S120M40A","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLD-1R-S120M40A-b.jpg?v=1777364426","url":"https:\/\/kupopower.com\/products\/pfld-1r","provider":"KUPO Power","version":"1.0","type":"link"}