{"product_id":"pfld-nw-c300m40","title":"PFLD-NW-C300M40 - PowerFit 750A Drain Line Connector, White (N)","description":"\u003c!-- Combined Shopify product HTML for PFLD-NW-C300M40 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLD-NW-C300M40\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 750A Line Drain Connector (White) | PFLD-NW-C300M40 | 2026-05-07 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLD-NW-C300M40\" data-color=\"White\"\u003e\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eHigh-current power distribution demands connectors that stay reliable under repeated load-in, load-out, and field-service cycles. The PowerFit 750A Line Drain connector in white is built for N circuits, combining female contact, silver-plated copper contact construction, and a secure push-and-twist locking mechanism. For installation, it uses an M40 x 1.5 cable gland with rubber bushing for sealed 300mm² cable assemblies. IP67 protection when mated and a UL94-V0 thermoplastic body help maintain safe performance in demanding touring, event, and industrial environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003e750A High-Current Rating:\u003c\/strong\u003e 750A Maximum for heavy-duty single-pole power distribution\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eFemale Contact Design:\u003c\/strong\u003e Line Drain (Female Contact) for mating with compatible PowerFit Line Source or Panel Source connectors\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003ePositive Push-and-Twist Lock:\u003c\/strong\u003e Maintains secure mechanical engagement after mating\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eCopper Silver-Plated Contact:\u003c\/strong\u003e Excellent conductivity with 0.1m Ohms contact resistance for reduced voltage drop\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eErgonomic Rubber Grip:\u003c\/strong\u003e Enhances handling comfort and control during cable connection work\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eIP67-Rated Cable Sealing:\u003c\/strong\u003e M40 x 1.5 with sealing bushing (Inner Diameter: 22 mm and 33 mm)\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eSilicone O-Ring:\u003c\/strong\u003e Provides protection against water and dust ingress after mating\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eDurable Thermoplastic Housing:\u003c\/strong\u003e Non-conductive high impact-resistant body with UL94-V0 flame rating\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eVoltage Capacity:\u003c\/strong\u003e 1000V AC, 1500V DC Maximum with 4500V AC test voltage\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eCertified Safety:\u003c\/strong\u003e TUV, CE, RoHS and REACH compliant for professional power distribution systems\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eTÜV certified for professional power connector applications\u003c\/li\u003e\n      \u003cli\u003eCE Marking\u003c\/li\u003e\n      \u003cli\u003eRoHS Compliant\u003c\/li\u003e\n      \u003cli\u003eREACH Compliant\u003c\/li\u003e\n      \u003cli\u003eUL94-V0 Flame Rating\u003c\/li\u003e\n      \u003cli\u003eIP67 rating while mated\u003c\/li\u003e\n      \u003cli\u003e1000V AC, 1500V DC maximum voltage rating; 4500V AC test voltage\u003c\/li\u003e\n      \u003cli\u003eShort circuit rating: Up to 35.5kA; insulation resistance \u0026gt; 5000M Ohms at 500V AC\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eLive Event Audio \u0026amp; Video Production\u003c\/li\u003e\n      \u003cli\u003eTouring Sound Systems\u003c\/li\u003e\n      \u003cli\u003eStage \u0026amp; Lighting Power Distribution\u003c\/li\u003e\n      \u003cli\u003eConcert \u0026amp; Festival Infrastructure\u003c\/li\u003e\n      \u003cli\u003eMobile Production Trucks\u003c\/li\u003e\n      \u003cli\u003eRental \u0026amp; House Power Management\u003c\/li\u003e\n      \u003cli\u003eIndustrial High-Current Power Distribution\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003eRated Amperage:\u003c\/strong\u003e 750A Maximum\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 1000V AC, 1500V DC Maximum\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eCable Compatibility:\u003c\/strong\u003e M40 x 1.5 with sealing bushing (Inner Diameter: 22 mm and 33 mm); crimp termination for 300mm² cable\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eMating Standard:\u003c\/strong\u003e Push-and-twist\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eMating Role:\u003c\/strong\u003e Line Drain (Female Contact) mates with compatible Line Source or Panel Source connectors\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003ePhase Marking:\u003c\/strong\u003e Neutral (NEC - North American)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"@id\": \"urn:sku:PFLD-NW-C300M40\",\n  \"name\": \"PFLD-NW-C300M40 | PowerFit 750A Line Drain, Neutral (NEC - North American) White\",\n  \"description\": \"KUPO PowerFit 750A Line Drain single-pole connector with white housing for Neutral (NEC - North American) power distribution systems. Female Contact, Push-and-twist, IP67 rated when mated, silver-plated copper contacts, 750A Maximum, 1000V AC, 1500V DC Maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLD-NW-C300M40\",\n  \"mpn\": \"PFLD-NW-C300M40\",\n  \"productID\": \"PFLD-NW-C300M40\",\n  \"model\": \"PFLD-NW-C300M40\",\n  \"identifier\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"propertyID\": \"SKU\",\n      \"value\": \"PFLD-NW-C300M40\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"propertyID\": \"MPN\",\n      \"value\": \"PFLD-NW-C300M40\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"propertyID\": \"PowerFit Series\",\n      \"value\": \"750A\"\n    }\n  ],\n  \"color\": \"White\",\n  \"material\": \"Non-conductive thermoplastic housing; Copper silver-plated contacts\",\n  \"itemCondition\": \"https:\/\/schema.org\/NewCondition\",\n  \"audience\": {\n    \"@type\": \"Audience\",\n    \"audienceType\": \"Professional power distribution, live event production, touring, rental-house, generator, and industrial electrical users\"\n  },\n  \"keywords\": [\n    \"PowerFit 750A\",\n    \"single-pole power connector\",\n    \"Line Drain\",\n    \"Line Drain (Female Contact)\",\n    \"N\",\n    \"Neutral (NEC - North American)\",\n    \"IP67 power connector\",\n    \"TUV certified connector\",\n    \"high-current power distribution\"\n  ],\n  \"subjectOf\": {\n    \"@type\": \"DigitalDocument\",\n    \"name\": \"PFLD-NW-C300M40 PowerFit 750A Spec Sheet\",\n    \"encodingFormat\": \"application\/pdf\",\n    \"url\": \"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/Powerfit%20750A%20Spec%20Sheet\/PFLD-NW-C300M40.pdf\"\n  },\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Product Family\",\n      \"value\": \"PowerFit 750A\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Role\",\n      \"value\": \"Line Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Source \/ Drain Orientation\",\n      \"value\": \"Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mounting Format\",\n      \"value\": \"Line \/ cable mount\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC, 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"750A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5kA\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"\u003e 5000M Ohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1m Ohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Drain (Female Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing (Inner Diameter: 22 mm and 33 mm)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Type\",\n      \"value\": \"Crimp termination for 300mm2 cable\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Size\",\n      \"value\": \"300mm2\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 Celsius Degree\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Neutral (NEC - North American)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"White\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLD-NW-C300M40\" data-category=\"PowerFit 750A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhy use PFLD-NW-C300M40 as the drain side of a 750A PowerFit connection?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-NW-C300M40 is the receiving side of the PowerFit 750A connection, built to accept the mating source contact and hold the circuit mechanically stable after the push-and-twist engagement. The drain-side design is especially important on feeder runs and panel outputs because it keeps the energized source geometry on the correct side of the system while maintaining IP67 sealing when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does PFLD-NW-C300M40 manage heat and voltage drop at 750A loads?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-NW-C300M40 uses a silver-plated copper contact with 0.1m Ohms contact resistance, which helps limit resistive heating at sustained current. It is rated for 750A Maximum with a maximum voltage rating of 1000V AC, 1500V DC, a 4500V AC dielectric test voltage, and short circuit capacity of up to 35.5kA. For real installations, the connector should still be paired with correctly sized cable, proper termination practice, and load calculations for the full distribution run.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the white housing on PFLD-NW-C300M40 tell the crew before power is applied?\u003c\/h3\u003e\n    \u003cp\u003eThe white housing identifies Neutral (NEC - North American). On the Line Drain connector, the color remains visible on the 190mm body, so a technician can trace the intended conductor before coupling or energizing the system. This is more than cosmetic: the SKU code and housing color work together to reduce cross-phase mistakes when different regional color conventions appear in the same rental inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat should installers notice about the cable end of PFLD-NW-C300M40?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-NW-C300M40 is a crimp-style line connector for 300mm2 cable using an M40 x 1.5 cable gland with sealing bushing. The bushing supports 22mm and 33mm inner diameters, giving the assembly the compression needed for a sealed cable entry. In field terms, the gland is part of the electrical system, not just a strain relief: poor cable fit can compromise both handling and environmental protection.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does PFLD-NW-C300M40 hold up in outdoor event or rental-house service?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-NW-C300M40 is IP67 rated while mated, uses a non-conductive high impact-resistant thermoplastic body, and carries a UL94-V0 body material rating. The 500-cycle mating rating suits rental and production environments where connectors are repeatedly assembled, inspected, packed, and redeployed. In wet grass, dusty stages, and temporary generator yards, the sealed mated interface is the detail that keeps a power run from becoming the weak point of the show.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat source connector should be matched with PFLD-NW-C300M40?\u003c\/h3\u003e\n    \u003cp\u003ePFLD-NW-C300M40 should be matched with the corresponding PowerFit 750A source connector for the same phase or conductor color. The drain connector receives the source contact and completes the sealed push-and-twist interface, so the safest layout is one where SKU, housing color, and conductor assignment all agree. Before energizing, confirm that the mating source is rated for the same current, voltage, and environmental conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhy does the rubber grip matter on PFLD-NW-C300M40?\u003c\/h3\u003e\n    \u003cp\u003eThe ergonomic rubber grip is useful because 750A feeder connectors are often handled with gloves, in low light, or while cables are under awkward mechanical tension. A better grip helps the technician align the connector, complete the push-and-twist motion cleanly, and avoid using the cable jacket as a handle. That small handling detail becomes important when a crew is building multiple feeder runs under schedule pressure.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Why use PFLD-NW-C300M40 as the drain side of a 750A PowerFit connection?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-NW-C300M40 is the receiving side of the PowerFit 750A connection, built to accept the mating source contact and hold the circuit mechanically stable after the push-and-twist engagement. The drain-side design is especially important on feeder runs and panel outputs because it keeps the energized source geometry on the correct side of the system while maintaining IP67 sealing when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How does PFLD-NW-C300M40 manage heat and voltage drop at 750A loads?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-NW-C300M40 uses a silver-plated copper contact with 0.1m Ohms contact resistance, which helps limit resistive heating at sustained current. It is rated for 750A Maximum with a maximum voltage rating of 1000V AC, 1500V DC, a 4500V AC dielectric test voltage, and short circuit capacity of up to 35.5kA. For real installations, the connector should still be paired with correctly sized cable, proper termination practice, and load calculations for the full distribution run.\"}}, {\"@type\": \"Question\", \"name\": \"What does the white housing on PFLD-NW-C300M40 tell the crew before power is applied?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The white housing identifies Neutral (NEC - North American). On the Line Drain connector, the color remains visible on the 190mm body, so a technician can trace the intended conductor before coupling or energizing the system. This is more than cosmetic: the SKU code and housing color work together to reduce cross-phase mistakes when different regional color conventions appear in the same rental inventory.\"}}, {\"@type\": \"Question\", \"name\": \"What should installers notice about the cable end of PFLD-NW-C300M40?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-NW-C300M40 is a crimp-style line connector for 300mm2 cable using an M40 x 1.5 cable gland with sealing bushing. The bushing supports 22mm and 33mm inner diameters, giving the assembly the compression needed for a sealed cable entry. In field terms, the gland is part of the electrical system, not just a strain relief: poor cable fit can compromise both handling and environmental protection.\"}}, {\"@type\": \"Question\", \"name\": \"How does PFLD-NW-C300M40 hold up in outdoor event or rental-house service?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-NW-C300M40 is IP67 rated while mated, uses a non-conductive high impact-resistant thermoplastic body, and carries a UL94-V0 body material rating. The 500-cycle mating rating suits rental and production environments where connectors are repeatedly assembled, inspected, packed, and redeployed. In wet grass, dusty stages, and temporary generator yards, the sealed mated interface is the detail that keeps a power run from becoming the weak point of the show.\"}}, {\"@type\": \"Question\", \"name\": \"What source connector should be matched with PFLD-NW-C300M40?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLD-NW-C300M40 should be matched with the corresponding PowerFit 750A source connector for the same phase or conductor color. The drain connector receives the source contact and completes the sealed push-and-twist interface, so the safest layout is one where SKU, housing color, and conductor assignment all agree. Before energizing, confirm that the mating source is rated for the same current, voltage, and environmental conditions.\"}}, {\"@type\": \"Question\", \"name\": \"Why does the rubber grip matter on PFLD-NW-C300M40?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The ergonomic rubber grip is useful because 750A feeder connectors are often handled with gloves, in low light, or while cables are under awkward mechanical tension. A better grip helps the technician align the connector, complete the push-and-twist motion cleanly, and avoid using the cable jacket as a handle. That small handling detail becomes important when a crew is building multiple feeder runs under schedule pressure.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLD-NW-C300M40\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/Powerfit%20750A%20Spec%20Sheet\/PFLD-NW-C300M40.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLD-NW-C300M40 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e\n","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 750A \/ Inline Connector","offer_id":50313058058460,"sku":"PFLD-NW-C300M40","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLD-NW-C300M40.jpg?v=1779329784","url":"https:\/\/kupopower.com\/products\/pfld-nw-c300m40","provider":"KUPO Power","version":"1.0","type":"link"}