{"product_id":"pfls-2bk","title":"PFLS-2BK-S120M40A - PowerFit 400A Source Line Connector, Black (L2)","description":"\u003c!-- Combined Shopify product HTML for PFLS-2BK-S120M40A --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLS-2BK-S120M40A\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Line Source Connector (Black) | PFLS-2BK-S120M40A | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLS-2BK-S120M40A\" data-color=\"Black\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLS-2BK-S120M40A brings industrial-grade power distribution to European and IEC-standard installations. As a Line Source connector with male contact and patent key-release pin, this inline solution enables seamless mating to Drain connectors while supporting 400A continuous current. The black phase conductor aligns with IEC conventions for L2 applications across industrial facilities, temporary power systems, and event staging where reliable European power standards are required.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMale Contact with Key-Release Pin:\u003c\/strong\u003e Innovative push-and-twist design with tool-free disconnection via patent key-release mechanism for user safety and rapid reconnection workflows.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePush-and-Twist Connection:\u003c\/strong\u003e Intuitive mating procedure - no CAM tools or complex alignment steps required in high-pressure event environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact POM Cotter Pin:\u003c\/strong\u003e Shorter polyoxymethylene pin optimizes connector footprint while maintaining reliable locking; removable with small slotted screwdriver if field adjustment is needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e400A Continuous Capacity:\u003c\/strong\u003e Rated for 400A with 120mm² cable; upgradeable to 660A with 240mm² cable configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP67 Sealed Mating:\u003c\/strong\u003e Protects against dust, water spray, and temporary submersion when connectors are fully mated and locked.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eM40 Cable Gland with Dual Bushings:\u003c\/strong\u003e Nylon and rubber sealing system with 22mm and 33mm ID options ensures strain relief across cable diameter ranges.\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTÜV Rheinland:\u003c\/strong\u003e Certified (ID 1111303479)  -  Type Approval, Safety, Regular Production Surveillance\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCE Marked\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS \u0026amp; REACH:\u003c\/strong\u003e Fully compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-2BK-S120M40A excels in European and IEC-compliant installations:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial facilities with three-phase power distribution\u003c\/li\u003e\n\u003cli\u003eTemporary power systems for construction, theater, and event production\u003c\/li\u003e\n\u003cli\u003eData centers and critical infrastructure requiring 400A L2 branch circuits\u003c\/li\u003e\n\u003cli\u003eBroadcasting and live entertainment setups where rapid power deployment is essential\u003c\/li\u003e\n\u003cli\u003eRenewable energy installations (solar farms, wind systems) with European grid compliance\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-2BK-S120M40A (Source) mates directly with PFLD-2BK-S120M40A (Line Drain) and PFPD-2BK (Panel Drain) connectors, completing power chains from source through distribution to branch circuits. This connector is compatible with major brands of single-pole power connector systems. Ensure matching phase conductors (L2 Black\/IEC) throughout the circuit to prevent cross-phasing.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLS-2BK-S120M40A | PowerFit 400A Line Source, L2 (Phase B) Black (IEC - European)\",\n  \"description\": \"KUPO PowerFit 400A Line Source single-pole connector with black housing for IEC - European power distribution systems. Male Contact, patent key-release pin for safe disconnection, M40 cable gland with sealing bushing, IP67 rated when mated, silver-plated brass contacts, dual-rated 400A\/660A, 1000V AC \/ 1500V DC maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLS-2BK-S120M40A\",\n  \"mpn\": \"PFLS-2BK-S120M40A\",\n  \"color\": \"Black\",\n  \"material\": \"Non-conductive thermoplastic housing; Brass silver-plated contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC \/ 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A continuous (120mm\u0026sup2; cable) \/ 660A continuous (240mm\u0026sup2; cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5 kiloamperes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Source (Male Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-Twist with Key-Release Mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cotter Pin Material\",\n      \"value\": \"POM (Polyoxymethylene)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing (Inner Diameter: 22mm and 33mm)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Set Screw Torque\",\n      \"value\": \"10.5 N\/meter minimum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"TUV Certification ID\",\n      \"value\": \"1111303479\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV Rheinland, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 (Phase B) (IEC - European)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Black\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLS-2BK-S120M40A\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhy was PFLS-2BK-S120M40A designed with a key-release mechanism?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2BK-S120M40A is a KUPO PowerFit 400A line source connector with a black housing, identifying Line 2 (L2) under Europe and UK (IEC 60446) conventions. As the source side of an inline cable connection, it features the innovative patent key-release pin that enables tool-free disconnection. The push-and-twist mechanism secures the connection during operation while allowing rapid uncoupling when needed. It is commonly deployed in industrial manufacturing plant applications. Temporary power in manufacturing environments faces vibration from heavy machinery, exposure to oils and cutting fluids, and the need for high current capacity to feed welders, presses, and large motors.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat electrical performance does PFLS-2BK-S120M40A deliver?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2BK-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for L2 circuits carrying continuous phase current.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhy choose the black L2 variant (PFLS-2BK-S120M40A) for your installation?\u003c\/h3\u003e\n    \u003cp\u003eUnder IEC 60446, black identifies Line 2 (L2). This is the second phase conductor in the European three-phase system of brown (L1), black (L2), grey (L3). For international crews, this is a critical distinction: the same black housing that means L1 in North America means L2 in Europe. On the Line Source connector, the black housing wraps the 170mm body including the area around the key-release mechanism. This means the phase is identifiable even during the push-and-twist connection process, reducing the chance of connecting to the wrong L2 circuit. Cross-convention errors between NEC-L1-black and IEC-L2-black are among the most common phase identification mistakes on international projects.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety certifications apply to PFLS-2BK-S120M40A?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-2BK-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The key-release pin mechanism has been certified as part of the TUV evaluation, ensuring that the disconnect feature meets the same safety standards as the connection itself.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs PFLS-2BK-S120M40A compatible with single-pole connectors from other manufacturers?\u003c\/h3\u003e\n    \u003cp\u003ePowerFit connectors are designed to be compatible with major brands of single-pole power connector. The 400A continuous rating (660A with 240mm2 cable) handles industrial loads, the flame-retardant UL94-V0 housing resists chemical exposure, and the push-and-twist lock prevents vibration-induced disconnection. For L2 circuits using Europe and UK (IEC 60446) color conventions, the black PFLS-2BK-S120M40A ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Why was PFLS-2BK-S120M40A designed with a key-release mechanism?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2BK-S120M40A is a KUPO PowerFit 400A line source connector with a black housing, identifying Line 2 (L2) under Europe and UK (IEC 60446) conventions. As the source side of an inline cable connection, it features the innovative patent key-release pin that enables tool-free disconnection. The push-and-twist mechanism secures the connection during operation while allowing rapid uncoupling when needed. It is commonly deployed in industrial manufacturing plant applications. Temporary power in manufacturing environments faces vibration from heavy machinery, exposure to oils and cutting fluids, and the need for high current capacity to feed welders, presses, and large motors.\"}}, {\"@type\": \"Question\", \"name\": \"What electrical performance does PFLS-2BK-S120M40A deliver?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2BK-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for L2 circuits carrying continuous phase current.\"}}, {\"@type\": \"Question\", \"name\": \"Why choose the black L2 variant (PFLS-2BK-S120M40A) for your installation?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Under IEC 60446, black identifies Line 2 (L2). This is the second phase conductor in the European three-phase system of brown (L1), black (L2), grey (L3). For international crews, this is a critical distinction: the same black housing that means L1 in North America means L2 in Europe. On the Line Source connector, the black housing wraps the 170mm body including the area around the key-release mechanism. This means the phase is identifiable even during the push-and-twist connection process, reducing the chance of connecting to the wrong L2 circuit. Cross-convention errors between NEC-L1-black and IEC-L2-black are among the most common phase identification mistakes on international projects.\"}}, {\"@type\": \"Question\", \"name\": \"What safety certifications apply to PFLS-2BK-S120M40A?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-2BK-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The key-release pin mechanism has been certified as part of the TUV evaluation, ensuring that the disconnect feature meets the same safety standards as the connection itself.\"}}, {\"@type\": \"Question\", \"name\": \"Is PFLS-2BK-S120M40A compatible with single-pole connectors from other manufacturers?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PowerFit connectors are designed to be compatible with major brands of single-pole power connector. The 400A continuous rating (660A with 240mm2 cable) handles industrial loads, the flame-retardant UL94-V0 housing resists chemical exposure, and the push-and-twist lock prevents vibration-induced disconnection. For L2 circuits using Europe and UK (IEC 60446) color conventions, the black PFLS-2BK-S120M40A ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLS-2BK-S120M40A\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLS-2BK-S120M40A.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLS-2BK-S120M40A Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 400A \/ Inline Connector","offer_id":50208843563228,"sku":"PFLS-2BK-S120M40A","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLS-2BK-S120M40A-b.jpg?v=1777364443","url":"https:\/\/kupopower.com\/products\/pfls-2bk","provider":"KUPO Power","version":"1.0","type":"link"}