{"product_id":"pfls-egn","title":"PFLS-EGN-S120M40A - PowerFit 400A Source Line Connector, Green (PE)","description":"\u003c!-- Combined Shopify product HTML for PFLS-EGN-S120M40A --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFLS-EGN-S120M40A\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Line Source Connector (Green) | PFLS-EGN-S120M40A | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFLS-EGN-S120M40A\" data-color=\"Green\"\u003e\n\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eThe PFLS-EGN-S120M40A is a 400A inline cable connector for protective earth (PE \/ ground) distribution, delivering the unambiguous safety-critical function that universal green coloring guarantees across all electrical standards. This Line Source connector houses the male contact and patent key-release pin, enabling tool-free disconnection while maintaining a reliable, low-resistance ground path. Earth is a life-safety function - this connector ensures it is installed, mated, and maintained with confidence.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eGreen (or green-with-yellow stripe) denotes protective earth across every major electrical convention: IEC, NEC, UK, Australia, and beyond. This universal convention eliminates any possibility of earth-phase confusion, ensuring that every technician worldwide recognizes this connector's critical safety function.\u003c\/li\u003e\n      \u003cli\u003eThe earth connector completes the fault-current path that protects personnel and equipment. Low contact resistance (0.1 milliohms) and high insulation integrity (\u0026gt;5000M Ohms) ensure that the ground path remains reliable under fault conditions, allowing protective devices to operate instantaneously.\u003c\/li\u003e\n      \u003cli\u003eThe male contact and key-release mechanism enable deliberate, controlled disconnection without tools. When performing maintenance or equipment shutdown, the earth connection is released only when explicitly commanded, preventing inadvertent loss of ground protection.\u003c\/li\u003e\n      \u003cli\u003eThe source variant uses a shorter polyoxymethylene (POM) cotter pin optimized for cable-mounted operation. Field disassembly with a small slotted screwdriver allows inspection and maintenance of the earth contact without specialized tools, ensuring the ground path integrity during commissioning and troubleshooting.\u003c\/li\u003e\n      \u003cli\u003eRated for 400A continuous with 120mm² cable, scaling to 660A with 240mm² cable. Fault-current capacity (35.5kA short circuit) ensures the earth contact can safely dissipate fault energy without melting or disconnecting.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eTÜV Rheinland certified (ID 1111303479), CE marked, RoHS, and REACH compliant. Meets all international requirements for protective earth circuits in machinery, industrial control, and power distribution systems.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePersonnel Protection:\u003c\/strong\u003e Industrial distribution centers, renewable energy systems, and heavy machinery requiring fault-current paths\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEquipment Safety:\u003c\/strong\u003e UPS systems, power conditioning, and critical load centers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor Installation:\u003c\/strong\u003e IP67 sealing protects ground circuits in weather-exposed environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Cycle Environments:\u003c\/strong\u003e 500-cycle rated for frequent maintenance and reconfigurations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmergency Shutdown Systems:\u003c\/strong\u003e Reliable earth disconnection during controlled power-down procedures\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRenewable Energy:\u003c\/strong\u003e Solar and wind installations requiring robust ground paths to earth rods or grids\u003c\/li\u003e\n\u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-EGN-S120M40A mates with corresponding PFLD (Line Drain) connectors and PFPS\/PFPD panel-mount variants. Compatible with major brands of single-pole power connectors. R120 reduction sleeve (brass, silver-plated) accommodates up to 16.50mm diameter wire for large-gauge earth conductors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFLS-EGN-S120M40A | PowerFit 400A Line Source, Earth (PE) Green (Universal protective earth\/ground)\",\n  \"description\": \"KUPO PowerFit 400A Line Source single-pole connector with green housing for Universal protective earth\/ground power distribution systems. Male Contact, patent key-release pin for safe disconnection, M40 cable gland with sealing bushing, IP67 rated when mated, silver-plated brass contacts, dual-rated 400A\/660A, 1000V AC \/ 1500V DC maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Single-Pole Connectors \u003e PowerFit\",\n  \"sku\": \"PFLS-EGN-S120M40A\",\n  \"mpn\": \"PFLS-EGN-S120M40A\",\n  \"color\": \"Green\",\n  \"material\": \"Non-conductive thermoplastic housing; Brass silver-plated contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC \/ 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A continuous (120mm\u0026sup2; cable) \/ 660A continuous (240mm\u0026sup2; cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5 kiloamperes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Line Source (Male Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-Twist with Key-Release Mechanism\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cotter Pin Material\",\n      \"value\": \"POM (Polyoxymethylene)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Cable Gland\",\n      \"value\": \"M40 x 1.5 with sealing bushing (Inner Diameter: 22mm and 33mm)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Set Screw Torque\",\n      \"value\": \"10.5 N\/meter minimum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"TUV Certification ID\",\n      \"value\": \"1111303479\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV Rheinland, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Earth (PE) (Universal protective earth\/ground)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Green\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFLS-EGN-S120M40A\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does PFLS-EGN-S120M40A improve on traditional single-pole power connectors?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-EGN-S120M40A is a KUPO PowerFit 400A line source connector with a green housing, designated for the Protective Earth (PE) conductor. As the source side of an inline cable connection, it features the innovative patent key-release pin that enables tool-free disconnection. The push-and-twist mechanism secures the connection during operation while allowing rapid uncoupling when needed. It is commonly deployed in mining and tunneling applications. Underground mining and tunnel construction require power distribution in confined, humid, dusty environments where safety standards are especially stringent and equipment must withstand harsh mechanical treatment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat electrical performance does PFLS-EGN-S120M40A deliver?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-EGN-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for PE circuits carrying continuous earth current.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the green housing on PFLS-EGN-S120M40A signify and why does it matter?\u003c\/h3\u003e\n    \u003cp\u003eGreen identifies the Protective Earth (PE) conductor across virtually every international standard: NEC, IEC, Australian, old UK, and Chinese GB. Some regions specify green\/yellow striped, but solid green is universally recognized as earth ground. Ground conductor integrity is the most critical safety element in any power distribution system. On the Line Source connector, the green housing wraps the 170mm body including the area around the key-release mechanism. This means the phase is identifiable even during the push-and-twist connection process, reducing the chance of connecting to the wrong PE circuit. A distinct green connector ensures the safety earth is never confused with a current-carrying phase or neutral conductor. This is non-negotiable for personnel safety and equipment protection.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat safety certifications apply to PFLS-EGN-S120M40A?\u003c\/h3\u003e\n    \u003cp\u003ePFLS-EGN-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The key-release pin mechanism has been certified as part of the TUV evaluation, ensuring that the disconnect feature meets the same safety standards as the connection itself.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eIs PFLS-EGN-S120M40A compatible with single-pole connectors from other manufacturers?\u003c\/h3\u003e\n    \u003cp\u003ePowerFit connectors are designed to be compatible with major brands of single-pole power connector. IP67 dust-tight and waterproof protection is critical underground, the 35.5 kA short circuit rating provides safety margin in high-fault-current mining distribution, and the non-conductive housing eliminates accidental current paths. For PE circuits using Universal (all regions) color conventions, the green PFLS-EGN-S120M40A ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does the key-release mechanism work on PFLS-EGN-S120M40A?\u003c\/h3\u003e\n    \u003cp\u003eThe PFLS-EGN-S120M40A features the innovative PowerFit push-and-twist connection. To connect, align the connector and push while twisting until it locks. To disconnect, the patent key-release pin enables tool-free uncoupling. Simply press the release and twist to separate. If needed, a small slotted screwdriver can assist with the release. For cable termination, the process follows the same steps as other PowerFit line connectors: strip 33mm of cable jacket, apply the reduction sleeve, tighten set screws to 10.5 N\/m minimum, and secure the M40 cable gland. Uses the shorter cotter pin variant (vs the longer pin in Line Drain). The shorter pin accommodates the key-release mechanism. Never reuse cotter pins.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"How does PFLS-EGN-S120M40A improve on traditional single-pole power connectors?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-EGN-S120M40A is a KUPO PowerFit 400A line source connector with a green housing, designated for the Protective Earth (PE) conductor. As the source side of an inline cable connection, it features the innovative patent key-release pin that enables tool-free disconnection. The push-and-twist mechanism secures the connection during operation while allowing rapid uncoupling when needed. It is commonly deployed in mining and tunneling applications. Underground mining and tunnel construction require power distribution in confined, humid, dusty environments where safety standards are especially stringent and equipment must withstand harsh mechanical treatment.\"}}, {\"@type\": \"Question\", \"name\": \"What electrical performance does PFLS-EGN-S120M40A deliver?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-EGN-S120M40A is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for PE circuits carrying continuous earth current.\"}}, {\"@type\": \"Question\", \"name\": \"What does the green housing on PFLS-EGN-S120M40A signify and why does it matter?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Green identifies the Protective Earth (PE) conductor across virtually every international standard: NEC, IEC, Australian, old UK, and Chinese GB. Some regions specify green\/yellow striped, but solid green is universally recognized as earth ground. Ground conductor integrity is the most critical safety element in any power distribution system. On the Line Source connector, the green housing wraps the 170mm body including the area around the key-release mechanism. This means the phase is identifiable even during the push-and-twist connection process, reducing the chance of connecting to the wrong PE circuit. A distinct green connector ensures the safety earth is never confused with a current-carrying phase or neutral conductor. This is non-negotiable for personnel safety and equipment protection.\"}}, {\"@type\": \"Question\", \"name\": \"What safety certifications apply to PFLS-EGN-S120M40A?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFLS-EGN-S120M40A is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. The key-release pin mechanism has been certified as part of the TUV evaluation, ensuring that the disconnect feature meets the same safety standards as the connection itself.\"}}, {\"@type\": \"Question\", \"name\": \"Is PFLS-EGN-S120M40A compatible with single-pole connectors from other manufacturers?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PowerFit connectors are designed to be compatible with major brands of single-pole power connector. IP67 dust-tight and waterproof protection is critical underground, the 35.5 kA short circuit rating provides safety margin in high-fault-current mining distribution, and the non-conductive housing eliminates accidental current paths. For PE circuits using Universal (all regions) color conventions, the green PFLS-EGN-S120M40A ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\"}}, {\"@type\": \"Question\", \"name\": \"How does the key-release mechanism work on PFLS-EGN-S120M40A?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The PFLS-EGN-S120M40A features the innovative PowerFit push-and-twist connection. To connect, align the connector and push while twisting until it locks. To disconnect, the patent key-release pin enables tool-free uncoupling. Simply press the release and twist to separate. If needed, a small slotted screwdriver can assist with the release. For cable termination, the process follows the same steps as other PowerFit line connectors: strip 33mm of cable jacket, apply the reduction sleeve, tighten set screws to 10.5 N\/m minimum, and secure the M40 cable gland. Uses the shorter cotter pin variant (vs the longer pin in Line Drain). The shorter pin accommodates the key-release mechanism. Never reuse cotter pins.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFLS-EGN-S120M40A\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFLS-EGN-S120M40A.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFLS-EGN-S120M40A Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 400A \/ Inline Connector","offer_id":50208843759836,"sku":"PFLS-EGN-S120M40A","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFLS-EGN-S120M40A-b.jpg?v=1777364453","url":"https:\/\/kupopower.com\/products\/pfls-egn","provider":"KUPO Power","version":"1.0","type":"link"}