{"product_id":"pfpd-2r-t7","title":"PFPD-2R-T7 - PowerFit 750A Drain Panel Connector, Red (L2)","description":"\u003c!-- Combined Shopify product HTML for PFPD-2R-T7 --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPD-2R-T7\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 750A Panel Drain Connector (Red) | PFPD-2R-T7 | 2026-05-07 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPD-2R-T7\" data-color=\"Red\"\u003e\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eHigh-current power distribution demands connectors that stay reliable under repeated load-in, load-out, and field-service cycles. The PowerFit 750A Panel Drain connector in red is built for L2 circuits, combining female contact, silver-plated copper contact construction, and a secure push-and-twist locking mechanism. For installation, it uses an M12 threaded post mount with brass nut and phosphor bronze washer for permanent panel installation. IP67 protection when mated and a UL94-V0 thermoplastic body help maintain safe performance in demanding touring, event, and industrial environments.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003e750A High-Current Rating:\u003c\/strong\u003e 750A Maximum for heavy-duty single-pole power distribution\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eFemale Contact Design:\u003c\/strong\u003e Panel Drain (Female Contact) for mating with compatible PowerFit Line Source or Panel Source connectors\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003ePositive Push-and-Twist Lock:\u003c\/strong\u003e Maintains secure mechanical engagement after mating\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eCopper Silver-Plated Contact:\u003c\/strong\u003e Excellent conductivity with 0.1m Ohms contact resistance for reduced voltage drop\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003ePanel-Mount Construction:\u003c\/strong\u003e M12 threaded post with brass nut and phosphor bronze washer for fixed installations\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eFour-Point Flange Mounting:\u003c\/strong\u003e 42mm x 42mm cut-out with four diameter 5.5mm fixing holes\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eSilicone O-Ring:\u003c\/strong\u003e Provides protection against water and dust ingress after mating\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eDurable Thermoplastic Housing:\u003c\/strong\u003e Non-conductive high impact-resistant body with UL94-V0 flame rating\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eVoltage Capacity:\u003c\/strong\u003e 1000V AC, 1500V DC Maximum with 4500V AC test voltage\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eCertified Safety:\u003c\/strong\u003e TUV, CE, RoHS and REACH compliant for professional power distribution systems\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eTÜV certified for professional power connector applications\u003c\/li\u003e\n      \u003cli\u003eCE Marking\u003c\/li\u003e\n      \u003cli\u003eRoHS Compliant\u003c\/li\u003e\n      \u003cli\u003eREACH Compliant\u003c\/li\u003e\n      \u003cli\u003eUL94-V0 Flame Rating\u003c\/li\u003e\n      \u003cli\u003eIP67 rating while mated\u003c\/li\u003e\n      \u003cli\u003e1000V AC, 1500V DC maximum voltage rating; 4500V AC test voltage\u003c\/li\u003e\n      \u003cli\u003eShort circuit rating: Up to 35.5kA; insulation resistance \u0026gt; 5000M Ohms at 500V AC\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eLive Event Audio \u0026amp; Video Production\u003c\/li\u003e\n      \u003cli\u003eGenerator Panels, Distro Boxes \u0026amp; Power Supply Enclosures\u003c\/li\u003e\n      \u003cli\u003eTouring Sound Systems\u003c\/li\u003e\n      \u003cli\u003eStage \u0026amp; Lighting Power Distribution\u003c\/li\u003e\n      \u003cli\u003eConcert \u0026amp; Festival Infrastructure\u003c\/li\u003e\n      \u003cli\u003eMobile Production Trucks\u003c\/li\u003e\n      \u003cli\u003eRental \u0026amp; House Power Management\u003c\/li\u003e\n      \u003cli\u003eIndustrial High-Current Power Distribution\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003e\n\u003cstrong\u003eRated Amperage:\u003c\/strong\u003e 750A Maximum\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 1000V AC, 1500V DC Maximum\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003ePanel Mount:\u003c\/strong\u003e M12 threaded post; 42mm x 42mm cut-out with four diameter 5.5mm fixing holes\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eMating Standard:\u003c\/strong\u003e Push-and-twist\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eMating Role:\u003c\/strong\u003e Panel Drain (Female Contact) mates with compatible Line Source or Panel Source connectors\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003ePhase Marking:\u003c\/strong\u003e L2 (Phase B) (NEC - North American)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"@id\": \"urn:sku:PFPD-2R-T7\",\n  \"name\": \"PFPD-2R-T7 | PowerFit 750A Panel Drain, L2 (Phase B) (NEC - North American) Red\",\n  \"description\": \"KUPO PowerFit 750A Panel Drain single-pole connector with red housing for L2 (Phase B) (NEC - North American) power distribution systems. Female Contact, Push-and-twist, IP67 rated when mated, silver-plated copper contacts, 750A Maximum, 1000V AC, 1500V DC Maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Panel-Mount Connectors \u003e PowerFit\",\n  \"sku\": \"PFPD-2R-T7\",\n  \"mpn\": \"PFPD-2R-T7\",\n  \"productID\": \"PFPD-2R-T7\",\n  \"model\": \"PFPD-2R-T7\",\n  \"identifier\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"propertyID\": \"SKU\",\n      \"value\": \"PFPD-2R-T7\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"propertyID\": \"MPN\",\n      \"value\": \"PFPD-2R-T7\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"propertyID\": \"PowerFit Series\",\n      \"value\": \"750A\"\n    }\n  ],\n  \"color\": \"Red\",\n  \"material\": \"Non-conductive thermoplastic housing; Copper silver-plated contacts\",\n  \"itemCondition\": \"https:\/\/schema.org\/NewCondition\",\n  \"audience\": {\n    \"@type\": \"Audience\",\n    \"audienceType\": \"Professional power distribution, live event production, touring, rental-house, generator, and industrial electrical users\"\n  },\n  \"keywords\": [\n    \"PowerFit 750A\",\n    \"single-pole power connector\",\n    \"Panel Drain\",\n    \"Panel Drain (Female Contact)\",\n    \"L2\",\n    \"L2 (Phase B) (NEC - North American)\",\n    \"IP67 power connector\",\n    \"TUV certified connector\",\n    \"high-current power distribution\"\n  ],\n  \"subjectOf\": {\n    \"@type\": \"DigitalDocument\",\n    \"name\": \"PFPD-2R-T7 PowerFit 750A Spec Sheet\",\n    \"encodingFormat\": \"application\/pdf\",\n    \"url\": \"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/Powerfit%20750A%20Spec%20Sheet\/PFPD-2R-T7.pdf\"\n  },\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Product Family\",\n      \"value\": \"PowerFit 750A\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Role\",\n      \"value\": \"Panel Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Source \/ Drain Orientation\",\n      \"value\": \"Drain\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mounting Format\",\n      \"value\": \"Panel mount\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC, 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"750A Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5kA\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"\u003e 5000M Ohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1m Ohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Drain (Female Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-twist\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Copper (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mounting Type\",\n      \"value\": \"Panel Mount with M12 Threaded Post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fixing Holes\",\n      \"value\": \"Four diameter 5.5mm holes; 42mm x 42mm cut-out dimension\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Maximum Nut Torque\",\n      \"value\": \"Maximum 12-14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 Celsius Degree\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 (Phase B) (NEC - North American)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Red\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPD-2R-T7\" data-category=\"PowerFit 750A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhy use PFPD-2R-T7 as the drain side of a 750A PowerFit connection?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2R-T7 is the receiving side of the PowerFit 750A connection, built to accept the mating source contact and hold the circuit mechanically stable after the push-and-twist engagement. The drain-side design is especially important on feeder runs and panel outputs because it keeps the energized source geometry on the correct side of the system while maintaining IP67 sealing when mated.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does PFPD-2R-T7 manage heat and voltage drop at 750A loads?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2R-T7 uses a silver-plated copper contact with 0.1m Ohms contact resistance, which helps limit resistive heating at sustained current. It is rated for 750A Maximum with a maximum voltage rating of 1000V AC, 1500V DC, a 4500V AC dielectric test voltage, and short circuit capacity of up to 35.5kA. For real installations, the connector should still be paired with correctly sized cable, proper termination practice, and load calculations for the full distribution run.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat does the red housing on PFPD-2R-T7 tell the crew before power is applied?\u003c\/h3\u003e\n    \u003cp\u003eThe red housing identifies L2 (Phase B) (NEC - North American). On the Panel Drain connector, the color remains visible on the panel-mounted face, so a technician can trace the intended conductor before coupling or energizing the system. This is more than cosmetic: the SKU code and housing color work together to reduce cross-phase mistakes when different regional color conventions appear in the same rental inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat panel detail matters most when mounting PFPD-2R-T7?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2R-T7 uses an M12 threaded post and mounts through a 42mm x 42mm cut-out with four diameter 5.5mm fixing holes. The brass nut and phosphor bronze washer should be tightened within the specified 12-14 N\/meter maximum torque range. That mounting geometry is what keeps the connector stable when heavy feeder cables are repeatedly connected, disconnected, or pulled at an angle near a distro panel.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does PFPD-2R-T7 hold up in outdoor event or rental-house service?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2R-T7 is IP67 rated while mated, uses a non-conductive high impact-resistant thermoplastic body, and carries a UL94-V0 body material rating. The 500-cycle mating rating suits rental and production environments where connectors are repeatedly assembled, inspected, packed, and redeployed. In wet grass, dusty stages, and temporary generator yards, the sealed mated interface is the detail that keeps a power run from becoming the weak point of the show.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat source connector should be matched with PFPD-2R-T7?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2R-T7 should be matched with the corresponding PowerFit 750A source connector for the same phase or conductor color. The drain connector receives the source contact and completes the sealed push-and-twist interface, so the safest layout is one where SKU, housing color, and conductor assignment all agree. Before energizing, confirm that the mating source is rated for the same current, voltage, and environmental conditions.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhere does PFPD-2R-T7 make the most sense in a power distribution build?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2R-T7 is best suited to fixed equipment faces such as generator output panels, portable distro boxes, switchgear doors, or custom power racks. It gives the panel builder a repeatable interface for high-current single-pole connections while preserving the same PowerFit phase-color logic used on the cable-mounted line connectors.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Why use PFPD-2R-T7 as the drain side of a 750A PowerFit connection?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2R-T7 is the receiving side of the PowerFit 750A connection, built to accept the mating source contact and hold the circuit mechanically stable after the push-and-twist engagement. The drain-side design is especially important on feeder runs and panel outputs because it keeps the energized source geometry on the correct side of the system while maintaining IP67 sealing when mated.\"}}, {\"@type\": \"Question\", \"name\": \"How does PFPD-2R-T7 manage heat and voltage drop at 750A loads?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2R-T7 uses a silver-plated copper contact with 0.1m Ohms contact resistance, which helps limit resistive heating at sustained current. It is rated for 750A Maximum with a maximum voltage rating of 1000V AC, 1500V DC, a 4500V AC dielectric test voltage, and short circuit capacity of up to 35.5kA. For real installations, the connector should still be paired with correctly sized cable, proper termination practice, and load calculations for the full distribution run.\"}}, {\"@type\": \"Question\", \"name\": \"What does the red housing on PFPD-2R-T7 tell the crew before power is applied?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The red housing identifies L2 (Phase B) (NEC - North American). On the Panel Drain connector, the color remains visible on the panel-mounted face, so a technician can trace the intended conductor before coupling or energizing the system. This is more than cosmetic: the SKU code and housing color work together to reduce cross-phase mistakes when different regional color conventions appear in the same rental inventory.\"}}, {\"@type\": \"Question\", \"name\": \"What panel detail matters most when mounting PFPD-2R-T7?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2R-T7 uses an M12 threaded post and mounts through a 42mm x 42mm cut-out with four diameter 5.5mm fixing holes. The brass nut and phosphor bronze washer should be tightened within the specified 12-14 N\/meter maximum torque range. That mounting geometry is what keeps the connector stable when heavy feeder cables are repeatedly connected, disconnected, or pulled at an angle near a distro panel.\"}}, {\"@type\": \"Question\", \"name\": \"How does PFPD-2R-T7 hold up in outdoor event or rental-house service?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2R-T7 is IP67 rated while mated, uses a non-conductive high impact-resistant thermoplastic body, and carries a UL94-V0 body material rating. The 500-cycle mating rating suits rental and production environments where connectors are repeatedly assembled, inspected, packed, and redeployed. In wet grass, dusty stages, and temporary generator yards, the sealed mated interface is the detail that keeps a power run from becoming the weak point of the show.\"}}, {\"@type\": \"Question\", \"name\": \"What source connector should be matched with PFPD-2R-T7?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2R-T7 should be matched with the corresponding PowerFit 750A source connector for the same phase or conductor color. The drain connector receives the source contact and completes the sealed push-and-twist interface, so the safest layout is one where SKU, housing color, and conductor assignment all agree. Before energizing, confirm that the mating source is rated for the same current, voltage, and environmental conditions.\"}}, {\"@type\": \"Question\", \"name\": \"Where does PFPD-2R-T7 make the most sense in a power distribution build?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2R-T7 is best suited to fixed equipment faces such as generator output panels, portable distro boxes, switchgear doors, or custom power racks. It gives the panel builder a repeatable interface for high-current single-pole connections while preserving the same PowerFit phase-color logic used on the cable-mounted line connectors.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPD-2R-T7\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/Powerfit%20750A%20Spec%20Sheet\/PFPD-2R-T7.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPD-2R-T7 Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e\n","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 750A \/ Panel Mount Receptacle","offer_id":50313058681052,"sku":"PFPD-2R-T7","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPD-2R-T7.jpg?v=1779329799","url":"https:\/\/kupopower.com\/products\/pfpd-2r-t7","provider":"KUPO Power","version":"1.0","type":"link"}