{"product_id":"pfpd-2w","title":"PFPD-2W - PowerFit 400A Drain Panel Connector, White (L2)","description":"\u003c!-- Combined Shopify product HTML for PFPD-2W --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPD-2W\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Panel Drain Connector (White) | PFPD-2W | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPD-2W\" data-color=\"White\"\u003e\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eAustralian renewable energy installations delivering wind power from remote coastal turbine farms to mainland grid distribution centers depend on permanent electrical interconnection infrastructure that maintains 400A continuous current under extreme environmental stress. The PowerFit 400A Panel Drain connector in white (Phase 2 \/ L2 Australia) provides the enclosure-mount architecture for secondary phase distribution in wind farm metering cabinets, substation switchboards, and point-of-common-coupling (PCC) control rooms, ensuring color-coded compliance with Australian electrical standards (AS\/NZS 3000). The innovative plastic end cap protects live electrical surfaces from accidental contact in wind farm control rooms, while the patent key-release pin simplifies tool-free disconnection during equipment maintenance windows.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003e400A continuous current rating at 120mm² cable; 660A at 240mm² cable for large-scale renewable energy delivery\u003c\/li\u003e\n      \u003cli\u003eFemale contact design ensures reliable mating with Panel Source connectors in wind farm electrical infrastructure\u003c\/li\u003e\n      \u003cli\u003eM12 threaded post with brass nut and spring washer provides secure fastening in coastal salt-air environments\u003c\/li\u003e\n      \u003cli\u003eFour diameter 5.5mm fixing holes (42mm  x  42mm cut-out) accommodate Australian electrical cabinet frame standards\u003c\/li\u003e\n      \u003cli\u003ePatent key-release pin enables renewable energy technicians to safely disconnect feeds without mechanical tools\u003c\/li\u003e\n      \u003cli\u003ePlastic end cap over female contact provides IP 2X finger protection in high-altitude wind farm installation conditions\u003c\/li\u003e\n      \u003cli\u003ePush-and-twist locking mechanism resists vibration from wind turbine and generator equipment operation\u003c\/li\u003e\n      \u003cli\u003eSilver-plated brass contact delivers 0.1 milliohms contact resistance across megawatt-scale power transmission\u003c\/li\u003e\n      \u003cli\u003eNon-conductive UL94-V0 thermoplastic housing meets Australian electrical safety standards for renewable installations\u003c\/li\u003e\n      \u003cli\u003eIP67 rating while mated protects against salt spray and moisture ingress from coastal wind farm locations\u003c\/li\u003e\n      \u003cli\u003eMaximum nut torque: 12 to 14 N\/meter ensures secure mounting in harsh coastal weather conditions\u003c\/li\u003e\n      \u003cli\u003eWhite color codes as Phase 2 (L2) under Australian electrical standards (AS\/NZS 3000)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eTÜV Rheinland certified (ID 1111303479) for global renewable energy infrastructure compliance\u003c\/li\u003e\n      \u003cli\u003eCE marking for international renewable energy equipment certification\u003c\/li\u003e\n      \u003cli\u003eRoHS and REACH compliant for environmental sustainability in renewable installations\u003c\/li\u003e\n      \u003cli\u003eUL94-V0 flame retardancy rating for wind farm electrical safety\u003c\/li\u003e\n      \u003cli\u003eIP67 rating (dust-tight, submersion-resistant) suitable for coastal wind farm installations\u003c\/li\u003e\n      \u003cli\u003e1000V AC \/ 1500V DC maximum operating voltage; 4500V AC dielectric test\u003c\/li\u003e\n      \u003cli\u003eShort circuit rating: Up to 35.5kA; insulation resistance greater than 5000 megohms at 500V AC\u003c\/li\u003e\n      \u003cli\u003eWorking temperature range: 45 to 85 degrees Celsius - stable across Australian tropical and temperate zones\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eOffshore and onshore wind farm metering and protection cabinet installations\u003c\/li\u003e\n      \u003cli\u003eSolar array inverter distribution panels for utility-scale photovoltaic installations\u003c\/li\u003e\n      \u003cli\u003eBattery energy storage system (BESS) interconnection for grid stabilization services\u003c\/li\u003e\n      \u003cli\u003ePoint-of-common-coupling (PCC) switchboards at renewable generation facilities\u003c\/li\u003e\n      \u003cli\u003eSubstation step-up transformer secondary distribution for renewable power export\u003c\/li\u003e\n      \u003cli\u003eMicrogrid and virtual power plant electrical infrastructure in rural and remote regions\u003c\/li\u003e\n      \u003cli\u003eRenewable energy hybrid systems combining wind, solar, and hydroelectric generation\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe PowerFit 400A Panel Drain connector is compatible with major brands of single-pole power connector systems used in Australian renewable energy installations. Its M12 threaded post interface and push-and-twist mating mechanism follow standardized connection geometry across certified suppliers. Verify that your Panel Source connector carries renewable-grade certifications (salt-spray testing, UV resistance) and matches your facility voltage and amperage specifications. The color-coded white housing complies with AS\/NZS 3000 phase identification standards used throughout Australian renewable energy infrastructure.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPD-2W | PowerFit 400A Panel Drain, L2 (Phase B) White (Australian)\",\n  \"description\": \"KUPO PowerFit 400A Panel Drain single-pole connector with white housing for Australian power distribution systems. Female Contact, M12 threaded post mount, IP67 rated when mated, silver-plated brass contacts, dual-rated 400A\/660A, 1000V AC \/ 1500V DC maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Panel-Mount Connectors \u003e PowerFit\",\n  \"sku\": \"PFPD-2W\",\n  \"mpn\": \"PFPD-2W\",\n  \"color\": \"White\",\n  \"material\": \"Non-conductive thermoplastic housing; Brass silver-plated contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC \/ 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A continuous (120mm\u0026sup2; cable) \/ 660A continuous (240mm\u0026sup2; cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5 kiloamperes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Drain (Female Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-Twist Lock\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mounting Type\",\n      \"value\": \"Panel Mount with M12 Threaded Post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fixing Holes\",\n      \"value\": \"Four diameter 5.5mm holes; 42mm x 42mm cut-out dimension\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fastener Material\",\n      \"value\": \"Brass nut and spring washer\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Maximum Nut Torque\",\n      \"value\": \"12 to 14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated; IP 2X finger protection\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"TUV Certification ID\",\n      \"value\": \"1111303479\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV Rheinland, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"L2 (Phase B) (Australian)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"White\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPD-2W\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat role does PFPD-2W serve in a power distribution enclosure?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2W is a KUPO PowerFit 400A panel drain connector with a white housing, identifying Line 2 (L2) under Australia conventions. Mounted permanently in enclosures and distribution boxes, it serves as the final destination in the PowerFit electric direction flow, where incoming power from Line Source connectors enters the downstream equipment. The four-point flange mount and M12 threaded post ensure vibration-resistant installation. It is commonly deployed in marine and shipyard applications. Shipyard and dockside power connections face salt spray, high humidity, and the corrosive marine environment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does PFPD-2W handle the electrical demands of fixed power distribution?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2W is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The M12 threaded post termination accepts conductors through a brass nut and washer assembly, tightened to a maximum of 12 to 14 N\/m. The four-point flange mount with 5.5mm fixing holes distributes mechanical load across the panel surface.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does the white color coding on PFPD-2W help identify L2 on the jobsite?\u003c\/h3\u003e\n    \u003cp\u003eWhite as L2 follows Australian wiring conventions, where the three-phase set is red (L1), white (L2), blue (L3). This variant specifically serves Australian, New Zealand, and related Asia-Pacific markets. On the Panel Drain, the white color is visible on the connector face that protrudes from the enclosure panel. When multiple PowerFit connectors are mounted side by side in a distribution box, the color-coded faces create a clear visual map of the phase layout for incoming connections. The stark visual contrast between white L2 and the darker L1\/L3 conductors makes phase tracing straightforward in Australian installations.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat regulatory approvals does PFPD-2W hold for fixed installations?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-2W is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. For permanent installations, the IP 2X finger protection prevents accidental contact with live parts when the connector face is exposed, and the four-point flange mount exceeds mechanical retention requirements.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat panel preparation does PFPD-2W require for permanent installation?\u003c\/h3\u003e\n    \u003cp\u003eInstalling PFPD-2W requires a 42 x 42mm cutout in the enclosure panel. The connector mounts through four 5.5mm fixing holes on its flange, distributing clamping force evenly for vibration resistance. The M12 threaded post accepts the brass nut and washer, tightened to a maximum of 12 to 14 N\/m. IP 2X finger protection is built into the connector face, preventing accidental contact with live parts when no mating connector is inserted. A plastic end cap protects the contacts during storage and transport. The Panel Drain has a 55.0mm flange width and 72.2mm total depth, with a 37.0mm body diameter. The flange provides a generous mounting surface for secure enclosure attachment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does PFPD-2W integrate with existing power infrastructure in marine and shipyard settings?\u003c\/h3\u003e\n    \u003cp\u003ePowerFit connectors are designed to be compatible with major brands of single-pole power connector. Silver-plated brass contacts resist corrosion far better than plain brass, the silicone O-ring maintains IP67 sealing in high-humidity conditions, and the non-conductive thermoplastic housing is impervious to salt corrosion. For L2 circuits using Australia color conventions, the white PFPD-2W ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What role does PFPD-2W serve in a power distribution enclosure?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2W is a KUPO PowerFit 400A panel drain connector with a white housing, identifying Line 2 (L2) under Australia conventions. Mounted permanently in enclosures and distribution boxes, it serves as the final destination in the PowerFit electric direction flow, where incoming power from Line Source connectors enters the downstream equipment. The four-point flange mount and M12 threaded post ensure vibration-resistant installation. It is commonly deployed in marine and shipyard applications. Shipyard and dockside power connections face salt spray, high humidity, and the corrosive marine environment.\"}}, {\"@type\": \"Question\", \"name\": \"How does PFPD-2W handle the electrical demands of fixed power distribution?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2W is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The M12 threaded post termination accepts conductors through a brass nut and washer assembly, tightened to a maximum of 12 to 14 N\/m. The four-point flange mount with 5.5mm fixing holes distributes mechanical load across the panel surface.\"}}, {\"@type\": \"Question\", \"name\": \"How does the white color coding on PFPD-2W help identify L2 on the jobsite?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"White as L2 follows Australian wiring conventions, where the three-phase set is red (L1), white (L2), blue (L3). This variant specifically serves Australian, New Zealand, and related Asia-Pacific markets. On the Panel Drain, the white color is visible on the connector face that protrudes from the enclosure panel. When multiple PowerFit connectors are mounted side by side in a distribution box, the color-coded faces create a clear visual map of the phase layout for incoming connections. The stark visual contrast between white L2 and the darker L1\/L3 conductors makes phase tracing straightforward in Australian installations.\"}}, {\"@type\": \"Question\", \"name\": \"What regulatory approvals does PFPD-2W hold for fixed installations?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-2W is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. For permanent installations, the IP 2X finger protection prevents accidental contact with live parts when the connector face is exposed, and the four-point flange mount exceeds mechanical retention requirements.\"}}, {\"@type\": \"Question\", \"name\": \"What panel preparation does PFPD-2W require for permanent installation?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Installing PFPD-2W requires a 42 x 42mm cutout in the enclosure panel. The connector mounts through four 5.5mm fixing holes on its flange, distributing clamping force evenly for vibration resistance. The M12 threaded post accepts the brass nut and washer, tightened to a maximum of 12 to 14 N\/m. IP 2X finger protection is built into the connector face, preventing accidental contact with live parts when no mating connector is inserted. A plastic end cap protects the contacts during storage and transport. The Panel Drain has a 55.0mm flange width and 72.2mm total depth, with a 37.0mm body diameter. The flange provides a generous mounting surface for secure enclosure attachment.\"}}, {\"@type\": \"Question\", \"name\": \"How does PFPD-2W integrate with existing power infrastructure in marine and shipyard settings?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PowerFit connectors are designed to be compatible with major brands of single-pole power connector. Silver-plated brass contacts resist corrosion far better than plain brass, the silicone O-ring maintains IP67 sealing in high-humidity conditions, and the non-conductive thermoplastic housing is impervious to salt corrosion. For L2 circuits using Australia color conventions, the white PFPD-2W ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPD-2W\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPD-2W.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPD-2W Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 400A \/ Panel Mount Receptacle","offer_id":50208844120284,"sku":"PFPD-2W","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPD-2W-b.jpg?v=1777364461","url":"https:\/\/kupopower.com\/products\/pfpd-2w","provider":"KUPO Power","version":"1.0","type":"link"}