{"product_id":"pfpd-egn","title":"PFPD-EGN - PowerFit 400A Drain Panel Connector, Green (PE)","description":"\u003c!-- Combined Shopify product HTML for PFPD-EGN --\u003e\n\u003cstyle\u003e\n.kupo-section-title {\n  margin: 1.25rem 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.3;\n  color: #005F96 !important;\n  letter-spacing: 0;\n}\n.product-description h3 {\n  color: #005F96 !important;\n  font-size: 18px !important;\n  font-weight: bold;\n  margin-top: 1.5rem;\n  margin-bottom: 0.75rem;\n  line-height: 1.35;\n  letter-spacing: 0;\n}\n.product-description,\n.product-description p,\n.product-description li {\n  color: #222222 !important;\n}\n.kupo-faq-seo-block {\n  margin: 3rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-faq-seo-block h2 {\n  margin: 0 0 1.6rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item h3 {\n  margin: 0 0 0.35rem 0;\n  font-size: 17px !important;\n  font-weight: 600;\n  line-height: 1.45;\n  color: #005F96 !important;\n}\n.kupo-faq-seo-item p {\n  margin: 0;\n  line-height: 1.6;\n  color: #222222 !important;\n}\n.kupo-download-section {\n  margin: 2rem 0 0 0;\n  padding: 0;\n  border: 0;\n  background: transparent;\n  box-sizing: border-box;\n}\n.kupo-download-section h2 {\n  margin: 0 0 1rem 0;\n  font-size: 22px !important;\n  font-weight: 700;\n  line-height: 1.4;\n  color: #005F96 !important;\n}\n.kupo-download-link {\n  display: inline-flex;\n  align-items: center;\n  gap: 0.4rem;\n  font-size: 16px !important;\n  line-height: 1.5;\n  color: #111111 !important;\n  font-weight: 600;\n  text-decoration: underline;\n}\n\u003c\/style\u003e\n\u003csection class=\"product-description\" data-sku=\"PFPD-EGN\"\u003e\n  \u003ch2 class=\"kupo-section-title\"\u003eProduct Description\u003c\/h2\u003e\n\u003c!-- PowerFit 400A Panel Drain Connector (Green) - Earth | PFPD-EGN | 2026-03-23 --\u003e\n\n\u003cdiv class=\"product-description\" data-sku=\"PFPD-EGN\" data-color=\"Green\"\u003e\n  \u003cdiv class=\"product-overview\"\u003e\n    \u003cp\u003eLife-safety electrical grounding infrastructure protecting personnel and equipment from fault currents demands permanent earth\/ground connections that maintain absolute reliability across decades of operation without maintenance. The PowerFit 400A Panel Drain connector in green (Earth \/ PE universal) provides the enclosure-mount architecture for protective ground distribution in industrial facility main switchboards, renewable energy infrastructure, and data center grounding systems where equipment fault protection directly impacts personnel safety and regulatory compliance. Operating at 400A continuous current with silver-plated brass contacts rated for 500 mating cycles, this connector delivers the patent key-release pin for safe maintenance disconnection and plastic end cap protection, serving as the final electrical barrier between live power circuits and earth ground return paths.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-features\"\u003e\n    \u003ch3\u003eKey Features\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003e400A continuous current rating at 120mm² cable; 660A at 240mm² cable for robust earth\/ground infrastructure\u003c\/li\u003e\n      \u003cli\u003eFemale contact design ensures secure mating with Panel Source grounding connectors in equipment cabinets\u003c\/li\u003e\n      \u003cli\u003eM12 threaded post with brass nut and spring washer provides reliable fastening for permanent ground connections\u003c\/li\u003e\n      \u003cli\u003eFour diameter 5.5mm fixing holes (42mm  x  42mm cut-out) accommodate standard grounding cabinet installations\u003c\/li\u003e\n      \u003cli\u003ePatent key-release pin enables safe disconnection of earth\/ground feeds during equipment maintenance without tools\u003c\/li\u003e\n      \u003cli\u003ePlastic end cap over female contact provides IP 2X finger protection - critical for life-safety grounding connections\u003c\/li\u003e\n      \u003cli\u003ePush-and-twist locking mechanism prevents vibration-induced separation of critical ground return paths\u003c\/li\u003e\n      \u003cli\u003eSilver-plated brass contact delivers 0.1 milliohms contact resistance, minimizing ground impedance and fault response time\u003c\/li\u003e\n      \u003cli\u003eNon-conductive UL94-V0 thermoplastic housing meets international electrical safety standards for grounding systems\u003c\/li\u003e\n      \u003cli\u003eIP67 rating while mated protects ground connections against moisture and dust ingress in harsh environments\u003c\/li\u003e\n      \u003cli\u003eMaximum nut torque: 12 to 14 N\/meter ensures secure mounting without damaging flange threads critical to grounding\u003c\/li\u003e\n      \u003cli\u003eGreen color coding provides universal earth\/protective ground (PE) identification across all major electrical standards globally\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-certifications\"\u003e\n    \u003ch3\u003eCertifications \u0026amp; Standards\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eTÜV Rheinland certified (ID 1111303479) for global safety-critical grounding infrastructure\u003c\/li\u003e\n      \u003cli\u003eCE marking for international electrical safety equipment certification\u003c\/li\u003e\n      \u003cli\u003eRoHS and REACH compliant for environmental responsibility in safety-critical systems\u003c\/li\u003e\n      \u003cli\u003eUL94-V0 flame retardancy rating for grounding system safety\u003c\/li\u003e\n      \u003cli\u003eIP67 rating (dust-tight, temporary submersion protection) suitable for permanent ground installations\u003c\/li\u003e\n      \u003cli\u003e1000V AC \/ 1500V DC maximum operating voltage; 4500V AC dielectric test for high-energy fault conditions\u003c\/li\u003e\n      \u003cli\u003eShort circuit rating: Up to 35.5kA for rapid fault clearance in protective grounding circuits\u003c\/li\u003e\n      \u003cli\u003eInsulation resistance greater than 5000 megohms at 500V AC ensuring integrity of earth connection\u003c\/li\u003e\n      \u003cli\u003eWorking temperature range: 45 to 85 degrees Celsius - stable across environmental extremes for continuous operation\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-applications\"\u003e\n    \u003ch3\u003eApplications\u003c\/h3\u003e\n    \u003cul\u003e\n      \u003cli\u003eIndustrial facility main switchboard earth\/protective ground (PE) distribution infrastructure\u003c\/li\u003e\n      \u003cli\u003eData center grounding bus and redundant ground topology implementation\u003c\/li\u003e\n      \u003cli\u003eRenewable energy facility (wind, solar, hydro) protective ground return systems\u003c\/li\u003e\n      \u003cli\u003eHospital and medical facility life-safety grounding systems for patient and staff protection\u003c\/li\u003e\n      \u003cli\u003eTelecommunications tower and broadcast facility lightning protection grounding networks\u003c\/li\u003e\n      \u003cli\u003eOil and gas facility hazardous area electrical system grounding compliance\u003c\/li\u003e\n      \u003cli\u003eAviation and spacecraft ground support equipment electrical safety grounding\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-compatibility\"\u003e\n    \u003ch3\u003eCompatibility\u003c\/h3\u003e\n    \u003cp\u003eThe PowerFit 400A Panel Drain connector is compatible with major brands of single-pole power connector systems used in safety-critical grounding applications. Its M12 threaded post interface and push-and-twist mating mechanism follow standardized connection geometry across certified suppliers. Verify that your Panel Source grounding connector carries life-safety certifications and is rated for your specific ground current requirements and fault protection specifications. The green color housing provides universal protective ground (PE) identification recognized across all major electrical standards, ensuring unambiguous grounding circuit identification.\u003c\/p\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"product-color-conventions\"\u003e\n    \u003ch3\u003ePhase \/ Wire Color Convention\u003c\/h3\u003e\n    \u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 540px; border-collapse: collapse; margin: 12px 0; border: 2px solid #999999;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: left; padding-left: 14px; border: 1px solid #cccccc; border-top: 2px solid #999999; border-left: 2px solid #999999; font-size: 14px; width: 22%;\"\u003eRegion\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL1\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL2\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eL3\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; font-size: 14px; width: 13%;\"\u003eN\u003c\/th\u003e\n  \u003cth style=\"background-color: #e0e0e0; color: #333333; font-weight: bold; padding: 10px 8px; text-align: center; border: 1px solid #cccccc; border-top: 2px solid #999999; border-right: 2px solid #999999; font-size: 14px; width: 26%;\"\u003eGround\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 120\/208V \u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eNA 277\/480V \u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC6600; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen \/ G-Y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eIEC 60446 \u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #8B4513; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #888888; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999;\"\u003eAU\/NZ Legacy \u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; height: 38px; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #ffffff; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #003399; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #222222; border: 1px solid #cccccc;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n  \u003ctd style=\"background-color: #f0f0f0; color: #333333; font-weight: bold; font-size: 13px; padding: 6px 8px 6px 14px; text-align: left; border: 1px solid #cccccc; border-left: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eChina \u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n  \u003ctd style=\"background-color: #DAA520; height: 38px; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #CC0000; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #4682B4; border: 1px solid #cccccc; border-bottom: 2px solid #999999;\"\u003e\u003c\/td\u003e\n  \u003ctd style=\"background-color: #228B22; color: #ffffff; font-weight: bold; font-size: 12px; text-align: center; border: 1px solid #cccccc; border-right: 2px solid #999999; border-bottom: 2px solid #999999;\"\u003eGreen-Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n    \u003cp style=\"font-size: 12px; color: #555555; line-height: 1.6; margin-top: 6px;\"\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e1\u003c\/sup\u003e North America 120\/208V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e2\u003c\/sup\u003e North America 277\/480V (NEMA \/ NEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e3\u003c\/sup\u003e Europe, UK, Australia (current IEC 60446)\u003cbr\u003e\u003csup style=\"color: #555; font-weight: bold;\"\u003e4\u003c\/sup\u003e Australia \/ New Zealand legacy (pre-IEC)   \u003csup style=\"color: #555; font-weight: bold;\"\u003e5\u003c\/sup\u003e China (GB 50303)   \u003cstrong\u003eG-Y\u003c\/strong\u003e = Green-Yellow (earth\/ground)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"PFPD-EGN | PowerFit 400A Panel Drain, Earth (PE) Green (Universal protective earth\/ground)\",\n  \"description\": \"KUPO PowerFit 400A Panel Drain single-pole connector with green housing for Universal protective earth\/ground power distribution systems. Female Contact, M12 threaded post mount, IP67 rated when mated, silver-plated brass contacts, dual-rated 400A\/660A, 1000V AC \/ 1500V DC maximum, TUV certified.\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"KUPO\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"KUPO CO. LTD\",\n    \"url\": \"https:\/\/www.kupopower.com\"\n  },\n  \"category\": \"Electrical Connectors \u003e Panel-Mount Connectors \u003e PowerFit\",\n  \"sku\": \"PFPD-EGN\",\n  \"mpn\": \"PFPD-EGN\",\n  \"color\": \"Green\",\n  \"material\": \"Non-conductive thermoplastic housing; Brass silver-plated contacts\",\n  \"additionalProperty\": [\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Voltage Rating\",\n      \"value\": \"1000V AC \/ 1500V DC Maximum\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Amperage Rating\",\n      \"value\": \"400A continuous (120mm\u0026sup2; cable) \/ 660A continuous (240mm\u0026sup2; cable)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Test Voltage\",\n      \"value\": \"4500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Short Circuit Rating\",\n      \"value\": \"Up to 35.5 kiloamperes\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Insulation Resistance\",\n      \"value\": \"Greater than 5000 megohms at 500V AC\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Resistance\",\n      \"value\": \"0.1 milliohms\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connector Type\",\n      \"value\": \"Panel Drain (Female Contact)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Connection Mechanism\",\n      \"value\": \"Push-and-Twist Lock\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Contact Material\",\n      \"value\": \"Brass (Silver-Plated)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Material\",\n      \"value\": \"Non-conductive high impact-resistant thermoplastic (UL94-V0 flame retardant)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"O-Ring Material\",\n      \"value\": \"Silicone\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mounting Type\",\n      \"value\": \"Panel Mount with M12 Threaded Post\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fixing Holes\",\n      \"value\": \"Four diameter 5.5mm holes; 42mm x 42mm cut-out dimension\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Fastener Material\",\n      \"value\": \"Brass nut and spring washer\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Maximum Nut Torque\",\n      \"value\": \"12 to 14 N\/meter\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"IP Rating\",\n      \"value\": \"IP67 when mated; IP 2X finger protection\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Flame Class\",\n      \"value\": \"UL94-V0\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Working Temperature Range\",\n      \"value\": \"45 to 85 degrees Celsius\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Mating Cycles\",\n      \"value\": \"500\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"TUV Certification ID\",\n      \"value\": \"1111303479\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Certifications\",\n      \"value\": \"TUV Rheinland, CE, RoHS, REACH\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Phase Convention\",\n      \"value\": \"Earth (PE) (Universal protective earth\/ground)\"\n    },\n    {\n      \"@type\": \"PropertyValue\",\n      \"name\": \"Housing Color\",\n      \"value\": \"Green\"\n    }\n  ]\n}\n\u003c\/script\u003e\n\u003c\/section\u003e\n\n\u003csection class=\"kupo-faq-seo-block\" data-product-id=\"PFPD-EGN\" data-category=\"PowerFit 400A Connectors\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat role does PFPD-EGN serve in a power distribution enclosure?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-EGN is a KUPO PowerFit 400A panel drain connector with a green housing, designated for the Protective Earth (PE) conductor. Mounted permanently in enclosures and distribution boxes, it serves as the final destination in the PowerFit electric direction flow, where incoming power from Line Source connectors enters the downstream equipment. The four-point flange mount and M12 threaded post ensure vibration-resistant installation. It is commonly deployed in mining and tunneling applications. Underground mining and tunnel construction require power distribution in confined, humid, dusty environments where safety standards are especially stringent and equipment must withstand harsh mechanical treatment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat are the electrical specifications of PFPD-EGN for panel installations?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-EGN is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for PE circuits carrying continuous earth current.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow does PFPD-EGN ensure proper earth conductor identification?\u003c\/h3\u003e\n    \u003cp\u003eGreen identifies the Protective Earth (PE) conductor across virtually every international standard: NEC, IEC, Australian, old UK, and Chinese GB. Some regions specify green\/yellow striped, but solid green is universally recognized as earth ground. Ground conductor integrity is the most critical safety element in any power distribution system. On the Panel Drain, the green color is visible on the connector face that protrudes from the enclosure panel. When multiple PowerFit connectors are mounted side by side in a distribution box, the color-coded faces create a clear visual map of the phase layout for incoming connections. A distinct green connector ensures the safety earth is never confused with a current-carrying phase or neutral conductor. This is non-negotiable for personnel safety and equipment protection.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat certifications make PFPD-EGN suitable for permanent installation?\u003c\/h3\u003e\n    \u003cp\u003ePFPD-EGN is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. For permanent installations, the IP 2X finger protection prevents accidental contact with live parts when the connector face is exposed, and the four-point flange mount exceeds mechanical retention requirements.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eHow is PFPD-EGN installed in a power distribution enclosure?\u003c\/h3\u003e\n    \u003cp\u003eInstalling PFPD-EGN requires a 42 x 42mm cutout in the enclosure panel. The connector mounts through four 5.5mm fixing holes on its flange, distributing clamping force evenly for vibration resistance. The M12 threaded post accepts the brass nut and washer, tightened to a maximum of 12 to 14 N\/m. IP 2X finger protection is built into the connector face, preventing accidental contact with live parts when no mating connector is inserted. A plastic end cap protects the contacts during storage and transport. The Panel Drain has a 55.0mm flange width and 72.2mm total depth, with a 37.0mm body diameter. The flange provides a generous mounting surface for secure enclosure attachment.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"kupo-faq-seo-item\"\u003e\n    \u003ch3\u003eWhat equipment and enclosures is PFPD-EGN designed to mount in?\u003c\/h3\u003e\n    \u003cp\u003ePowerFit connectors are designed to be compatible with major brands of single-pole power connector. IP67 dust-tight and waterproof protection is critical underground, the 35.5 kA short circuit rating provides safety margin in high-fault-current mining distribution, and the non-conductive housing eliminates accidental current paths. For PE circuits using Universal (all regions) color conventions, the green PFPD-EGN ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What role does PFPD-EGN serve in a power distribution enclosure?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-EGN is a KUPO PowerFit 400A panel drain connector with a green housing, designated for the Protective Earth (PE) conductor. Mounted permanently in enclosures and distribution boxes, it serves as the final destination in the PowerFit electric direction flow, where incoming power from Line Source connectors enters the downstream equipment. The four-point flange mount and M12 threaded post ensure vibration-resistant installation. It is commonly deployed in mining and tunneling applications. Underground mining and tunnel construction require power distribution in confined, humid, dusty environments where safety standards are especially stringent and equipment must withstand harsh mechanical treatment.\"}}, {\"@type\": \"Question\", \"name\": \"What are the electrical specifications of PFPD-EGN for panel installations?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-EGN is rated for 400 amperes continuous with 120mm2 cable, scaling to 660 amperes with 240mm2 cable. The maximum voltage rating is 1000V AC or 1500V DC. The silver-plated brass contact achieves a contact resistance of just 0.1 milliohms, significantly reducing resistive heating compared to plain brass contacts at sustained high-current loads. This low resistance is particularly important for PE circuits carrying continuous earth current.\"}}, {\"@type\": \"Question\", \"name\": \"How does PFPD-EGN ensure proper earth conductor identification?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Green identifies the Protective Earth (PE) conductor across virtually every international standard: NEC, IEC, Australian, old UK, and Chinese GB. Some regions specify green\/yellow striped, but solid green is universally recognized as earth ground. Ground conductor integrity is the most critical safety element in any power distribution system. On the Panel Drain, the green color is visible on the connector face that protrudes from the enclosure panel. When multiple PowerFit connectors are mounted side by side in a distribution box, the color-coded faces create a clear visual map of the phase layout for incoming connections. A distinct green connector ensures the safety earth is never confused with a current-carrying phase or neutral conductor. This is non-negotiable for personnel safety and equipment protection.\"}}, {\"@type\": \"Question\", \"name\": \"What certifications make PFPD-EGN suitable for permanent installation?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PFPD-EGN is TUV Rheinland certified (ID 1111303479) under Type Approval, Safety, and Regular Production Surveillance categories. It also carries CE marking, RoHS compliance (Restriction of Hazardous Substances), and REACH compliance. The housing material achieves a UL94-V0 flammability rating, which is the highest classification for vertical flame resistance in plastics, meaning the material self-extinguishes within 10 seconds with no flaming drips. For permanent installations, the IP 2X finger protection prevents accidental contact with live parts when the connector face is exposed, and the four-point flange mount exceeds mechanical retention requirements.\"}}, {\"@type\": \"Question\", \"name\": \"How is PFPD-EGN installed in a power distribution enclosure?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Installing PFPD-EGN requires a 42 x 42mm cutout in the enclosure panel. The connector mounts through four 5.5mm fixing holes on its flange, distributing clamping force evenly for vibration resistance. The M12 threaded post accepts the brass nut and washer, tightened to a maximum of 12 to 14 N\/m. IP 2X finger protection is built into the connector face, preventing accidental contact with live parts when no mating connector is inserted. A plastic end cap protects the contacts during storage and transport. The Panel Drain has a 55.0mm flange width and 72.2mm total depth, with a 37.0mm body diameter. The flange provides a generous mounting surface for secure enclosure attachment.\"}}, {\"@type\": \"Question\", \"name\": \"What equipment and enclosures is PFPD-EGN designed to mount in?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"PowerFit connectors are designed to be compatible with major brands of single-pole power connector. IP67 dust-tight and waterproof protection is critical underground, the 35.5 kA short circuit rating provides safety margin in high-fault-current mining distribution, and the non-conductive housing eliminates accidental current paths. For PE circuits using Universal (all regions) color conventions, the green PFPD-EGN ensures that phase identification remains consistent when mixing PowerFit connectors with existing inventory.\"}}]}\u003c\/script\u003e\n\u003csection class=\"kupo-download-section\" data-product-id=\"PFPD-EGN\"\u003e\n  \u003ch2\u003eDownload\u003c\/h2\u003e\n  \u003ca class=\"kupo-download-link\" href=\"https:\/\/pub-87314d729f334121b80f91e16c4e7f60.r2.dev\/PFPD-EGN.pdf\" target=\"_blank\" rel=\"noopener\" download\u003e\n    Download PFPD-EGN Spec Sheet (PDF)\n  \u003c\/a\u003e\n\u003c\/section\u003e","brand":"KUPO Power","offers":[{"title":"PowerFit Single Pole (IP67) \/ 400A \/ Panel Mount Receptacle","offer_id":50208844284124,"sku":"PFPD-EGN","price":0.0,"currency_code":"TWD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0828\/3491\/5548\/files\/PFPD-EGN.jpg?v=1777364465","url":"https:\/\/kupopower.com\/products\/pfpd-egn","provider":"KUPO Power","version":"1.0","type":"link"}