Product Description

POWERFIT 400A release-key locking line source connector, Black (N). The locking mechanism retains the mated connection; the PF-LOCK release key enables intentional separation and helps prevent accidental disconnection during use.

A separate release key provides controlled disconnection for power connections that require protection against accidental separation. Designed for cable-end connections; see the specifications for termination and cable requirements. The black housing identifies N in the Australian, UK colour-code configurations listed in the catalogue.

Key Features

  • Source-side locking design with PF-LOCK key release
  • Single-pole keyed interface with colour-coded conductor identification
  • IP67 protection while mated
  • Impact-resistant insulating housing; UL94-V0 material rating
  • Silver-plated brass contacts

Technical Specifications

Model PFLS-NBK-S120M40A-L
Current rating 400A maximum (120mm² cable)
Voltage rating 1000V AC/DC maximum
Cable accommodation 95 to 150 mm² (conductor Ø under 16.5 mm); M40 x 1.5; gland insert CG-M4015-32 for cable Ø14 to 33 mm, or CG-M4015 for cable Ø12 to 18 mm
Terminal type Double set screws, 10.5 N·m min.
Connection type Push-and-twist locking; PF-LOCK release key for separation
Connector type Single-pole, inline, source (male contact)
Housing material High impact-resistant thermoplastic, UL94-V0
Contact material Brass (silver-plated)
Protection rating IP67 while mated
Certifications TÜV Rheinland
Color coding Black (N)

Locking Operation

  1. Verify matching models, keying and conductor identification. Insert and rotate the connectors in the direction indicated on the label to lock.
  2. Isolate the supply and verify the circuit is de-energized before separation. Insert the PF-LOCK release key, then rotate as indicated and separate the connectors.
  3. Wear gloves when handling silver-plated components. Do not reuse the white locking pin.

Frequently Asked Questions

How is the locking connector separated?

After isolating the supply and verifying the circuit is de-energized, use the PF-LOCK release key and follow the direction indicated on the connector label.

Can the connector be disconnected under load?

No. Isolate the supply and verify that the circuit is de-energized before separating the connector.

How should the colour and L1, L2 or L3 be selected?

Select the housing colour and keying for the project's regional colour convention and conductor function. Also verify current rating, cable requirements and the mating connector.