Collection: POWERFIT 500A

KUPO POWERFIT 500A single-pole power connector family showing line source, line drain, panel source, and panel drain configurations
500A Maximum • 1000V AC/DC Maximum • IP67 While Mated • Brass Contacts with Silver Plating • 16 kA (1 s) Short-Time Withstand

POWERFIT 500A is a single-pole connector family rated to 500A maximum and 1000V AC or DC maximum. The range includes line and panel Source and Drain configurations, double set-screw termination for 150mm² cable on line connectors, M12 threaded-post termination for panel connectors, brass contacts with silver plating, and IP67 protection while mated.

Connector compatibility: POWERFIT 500A connectors are designed to intermate with corresponding Phase 3 (P3) PowerSafe and ITT Cannon Powerlock connectors with matching ratings and keying configurations.

Not for current interruption: de-energize the circuit before mating or unmating. POWERFIT connectors are not intended for load-break disconnection.

Understanding Source and Drain

POWERFIT uses Source and Drain names for the mating connector roles. Source connectors use a push-and-twist connection with a key release mechanism. Drain connectors use a push-and-twist connection and a silicone O-ring. A Source always mates with a Drain.

POWERFIT Source and Drain connection diagram showing Panel Source, Line Drain, Line Source, and Panel Drain
Role Configurations Connection detail
Source PFLS and PFPS Push-and-twist with key release mechanism
Drain PFLD and PFPD Push-and-twist with silicone O-ring

Find Your Configuration

All four configurations are offered in 16 phase and color codes. Line connectors use double set screws for 150mm² cable. Panel connectors use M12 threaded posts. Browse the complete range below, or use the configuration and phase collections for a more focused selection.

Line Source (PFLS)
Termination
Double set screws for 150mm² cable
Connection
Push-and-twist with key release mechanism
Mounting or cable entry
M40 x 1.5 cable gland; inserts for cable Ø14 to 33 mm or Ø12 to 18 mm
Line Drain (PFLD)
Termination
Double set screws for 150mm² cable
Connection
Push-and-twist
Mounting or cable entry
M40 x 1.5 cable gland; inserts for cable Ø14 to 33 mm or Ø12 to 18 mm
Panel Source (PFPS)
Termination
M12 threaded post
Connection
Push-and-twist with key release mechanism
Mounting or cable entry
47.5 mm diameter cutout with four 5.5 mm fixing holes on a 42 x 42 mm square
Panel Drain (PFPD)
Termination
M12 threaded post
Connection
Push-and-twist
Mounting or cable entry
47.5 mm diameter cutout with four 5.5 mm fixing holes on a 42 x 42 mm square

Line connectors carry the suffix -S150M40A and panel connectors the suffix -T5. For detailed dimensions, open the SKU datasheet below: page 1 is the datasheet and page 2 is the matching dimensional drawing.

Phase and Wire Color Convention

KUPO Power phase and wire color convention table

Browse by Phase

SKU Datasheets and Drawings

Line Source (PFLS)

Line Drain (PFLD)

Panel Source (PFPS)

Panel Drain (PFPD)

Technical Specifications

Electrical

Amperage rating 500A Maximum
Voltage rating 1000V AC/DC Maximum
Test voltage 4500V AC
Short-time withstand current 16 kA for 1 s (short-time withstand)
Insulation resistance > 5000 MΩ at 500V AC
Contact resistance 0.1 mΩ

Mechanical and Environmental

Line contact type Double set screws for 150mm² cable
Set screw torque (Line) 10.5 N·m minimum
Panel contact type M12 threaded post
Panel nut torque Maximum 12 to 14 N·m
Panel cutout 47.5 mm diameter cutout with four 5.5 mm fixing holes on a 42 x 42 mm square
Line cable gland M40 x 1.5; gland insert CG-M4015-32 for cable Ø14 to 33 mm, or CG-M4015 for cable Ø12 to 18 mm
Mating cycle 500
Ingress protection IP67 rating while mated
Working temperature -25 to 125 °C
Flammability UL94-V0 (body material rating)

Materials

Connector body Non-conductive high impact-resistant thermoplastic
Contact material Brass (silver-plated)
O-ring Silicone (Drain configurations)
Cable gland and bushing Nylon and rubber (Line configurations)
Nut and washer Brass (Panel configurations)

Line Cable Entry

POWERFIT 500A line connectors use an M40 x 1.5 cable gland. Choose the gland insert that matches the overall diameter of your cable.

Single-core copper conductor. Check two sizes before you order: the bare conductor must fit the contact, and the overall cable must fit the gland insert.
Single-core copper cable cut open. The orange arrow marks the overall cable diameter; the blue arrows mark the bare conductor diameter.
Overall cable diameter
Measured over the insulation and outer sheath. Decides the cable gland insert.
Conductor diameter
Bare copper only, without insulation or sheath. Decides whether the conductor fits the contact.
POWERFIT 400A / 500A
Line source & drain
Conductor cross-section
95 to 150 mm²
Conductor diameter
Ø < 16.5 mm
Overall cable diameter by gland insert
Ø 14 to 33 mm
CG-M4015-32
Ø 12 to 18 mm
CG-M4015
Panel source and panel drain connectors use an M12 threaded post and have no cable gland. Not sure your cable fits? Send us the cable datasheet and we will confirm.

Certifications and Compliance

Certification Detail
TÜV Rheinland Certified to IEC 61984 under ID 1111322264
Certifications and compliance TÜV, CB, UKCA, CE, RoHS and REACH compliant
Ingress protection IP67 rating while mated
Body flammability rating UL94-V0

Assembly Guide (English PDF)

Frequently Asked Questions

What terminations are available for POWERFIT 500A?

Line connectors use double set screws for 150mm² cable, tightened to 10.5 N·m minimum. Panel connectors use M12 threaded posts with a maximum nut torque of 12 to 14 N·m.

When does the IP67 rating apply?

Only while mated: POWERFIT 500A is rated IP67 when a Source and Drain are connected.

What is the difference between Source and Drain?

Source connectors have the key release mechanism. Drain connectors have the silicone O-ring. Both use a push-and-twist connection.

Can POWERFIT 500A mate with P3 or ITT connectors?

Yes. POWERFIT 500A connectors are designed to intermate with corresponding Phase 3 (P3) PowerSafe and ITT Cannon Powerlock connectors with matching ratings and keying configurations.

Can I connect or disconnect under load?

No. POWERFIT connectors are not for current interruption. De-energize the circuit before mating or unmating.

Where can I download a specific datasheet?

Each item number in the datasheet lists above links to its two-page PDF. The first page is the exact SKU datasheet and the second page is the matching dimensional drawing.

Choosing between 500A and 800A? Read the POWERFIT 500A vs 800A selection guide, or see POWERFIT 800A for 185 to 400 mm² cable and 800A loads.

Need help choosing POWERFIT 500A?

KUPO can help confirm Source and Drain configurations, phase-coded item numbers, cable and panel termination, and documentation.